Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electric Field’s Dueling Effects through Dehydration and Ion Separation in Driving NaCl Nucleation at Charged Nanoconfined Interfaces

Investigating nucleation in charged nanoconfined environments under electric fields is crucial for many scientific and engineering applications. Here we study the nucleation of NaCl from aqueous solution near charged surfaces using machine-learning-augmented enhanced sampling molecular dynamics simulations. Our simulations successfully drive phase transitions between the liquid and solid phases of NaCl. The solid phase is stabilized under electric fields, particularly at an intermediate surface charge density. We examine which physical characteristics drive the nucleation of NaCl from aqueous solutions and find that the removal of solvent water from Cl– at the solid precursor surface plays a more critical role than the accumulation of ions. Our simulations reveal the competing effects of electric fields on nucleation processes: they facilitate the removal of water, promoting nucleation, but also promote the separation of ion pairs, thereby hindering nucleation. Here, this work provides a framework for studying nucleation processes in nanoconfined environments under electric fields and provides physical insights for the design of electrochemistry materials.

Electric fields↗

Development of Extraction Chromatography Resins for Metal Ion Separations in Analytical Radiochemistry

Extraction chromatography resins are widely used in pretreatment for such as the analysis of radionuclides and metal ions, as well as the quantification of isotopes. These resins have been developed for the purpose of improving selectivity, reducing the generation amount of waste liquid, and performing simpler and faster separation compared with other separation methods such as solvent extraction, ion exchange, and coprecipitation. This paper explains, in an easy-to-understand manner, this extraction chromatography, including extractants, diluents, solid supports, etc. (A.O.)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Continuous Ion Separations by Insertion Processes

Humanity is reliant on many important chemical separations which are performed daily at the industrial scale. With a historical dependence on thermal distillation techniques, which require large amounts of energy, chemical separations account for 10-15% of energy consumption worldwide. Membrane-based alternatives mitigate separation energy demand, yet prove challenging to scale-up and possess intrinsic limitations. Membranes usually separate species based on size and charge exclusion mechanisms. Importantly, however, improvements in the selectivity of membranes almost always leads to lower permeability. Much of the fundamental research in the field of membrane separations is focused on breaking the scaling relationship between selectivity and permeance, and improving membrane lifetime and stability. As discussed next, our group is developing electrochemically active membranes that can be actuated by application of an electric field. The long-term goal is to control selectivity and permeance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass separator for low velocity ions

Separator provides broad beam of protons free of other charged species to simulate the solar wind in experiments designed to determine effect on materials.

King, H. J.↗

Wastewater Brine Purification and Recovery through Electrodialysis Ion Exchange

Reutilizing resources onboard the International Space Station (ISS) and for future deep space missions are critical for mission longevity and sustainability. Wastewater brine produced from water recovery systems contain chemical species that could be processed into a potential fertilizer for future plant systems. This can be achieved through a process called electrodialysis ion exchange. Wastewater containing inorganic salt components are fed through a series of ion exchange membranes to produce fertilizer (a phosphate rich stream), electrolysis-grade water, and other useful commodities. Electrodialysis cells consisting of anion and cation exchange membranes, monovalent anion exchange membranes, and bipolar membranes were utilized to achieve selective ion exchange. The use of the electrodialysis cells were effective for both water extraction and ion separation. Ions successfully diffused across their respective membranes into the concentrate, acid, and base streams. This resulted in pure water, a phosphate rich stream, and a separate anion/hydrogen and cation/hydroxide stream. However, sulfate and some phosphate ions were able to diffuse through the monovalent anion exchange membrane into the acid stream. This resulted in predominantly phosphate ions remaining in the concentrate. Optimization of the process was accomplished by altering flowrates of each stream and initial volumes, adjusting the power input and resulting current through each cell, and varying the starting parameters by splitting the inorganic waste input into the diluate and the concentrate. As expected, increasing the flowrate and the power input to each cell reduced the overall time of the process. However, mission constraints may require a longer duration process in order to reduce the power consumption. Further analysis will be required to determine the power input necessary to achieve ion diffusion effectively and in a timely manner.

Ion Exchange Membranes↗

One-step fabrication of robust lithium ion battery separators by polymerization-induced phase separation

Conventional lithium ion battery separators are microporous polyolefin membranes that play a passive role in the electrochemical cell. Next generation separators should offer significant performance enhancements, while being fabricated through facile, low cost approaches with the ability to readily tune physicochemical properties. This study presents a single-step manufacturing technique based on UV-initiated polymerization-induced phase separation (PIPS), wherein microporous separators are fabricated from multifunctional monomers and ethylene carbonate (EC), which functions as both the pore-forming agent (porogen) and electrolyte component in the electrochemical cell. By controlling the ratio of the 1,4-butanediol diacrylate (BDDA) monomer to ethylene carbonate, monolithic microporous membranes are readily prepared with 25 μm thickness and pore sizes and porosities ranging from 6.8 to 22 nm and 15.4% to 38.5%, respectively. With 38.5% apparent porosity and an average pore size of 22 nm, the poly(1,4-butanediol diacrylate) (pBDDA) separator takes up 127% liquid electrolyte, resulting in an ionic conductivity of 1.98 mS cm –1 , which is greater than in conventional Celgard 2500. Lithium ion battery half cells consisting of LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathodes and pBDDA separators were shown to undergo reversible charge/discharge cycling with an average discharge capacity of 142 mA h g –1 and a capacity retention of 98.4% over 100 cycles – comparable to cells using state-of-the-art separators. Moreover, similar discharge capacities were achieved in rate performance tests due to the high ionic conductivity and electrolyte uptake of the film. Finally, the pBDDA separators were shown to be thermally stable to 374 °C, lack low temperature thermal transitions that can compromise cell safety, and exhibit no thermal shrinkage up to 150 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations

The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling waves ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively-charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20 V0-p, 25 V0-p, and 30 V 0-p ). The calibration errors for the three calibrant sets Agilent tuning mixture and polyalanine, and one assembled in-house showed negligible differences using a sine-shaped TW waveform. Furthermore, calibration errors were all within 1-2 % of the DTIMS measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh resolution multi-pass (long path length) SLIM TWIMS demonstrated improved CCS calibration for phospholipid and bile acid isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Waveform Profiles for Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) have recently enabled a powerful implementation of traveling wave ion mobility spectrometry (TWIMS) for ultra-high resolution separations. However, optimization of experimental parameters remains challenging. Most TWIMS separations have utilized square-shaped waveforms applied by time-dependent voltage stepping across a repeating sets of electrodes; however, alternative waveforms may provide further improvements to resolution. In this work, we characterize five waveforms (including square and sine) in terms of their transmission efficiency, IMS resolution, and resolving power, and explore the effects of TW amplitude and speed on the performance of each. We found, consistent with previous work, separations were generally improved with higher TW amplitudes, moderately improved by lower speeds (limited by ion ‘surfing’ with the waves), and found decreases in signal intensity at the extremes of operating conditions. The triangle and asymmetric ‘ramp forward’ shaped profiles were found to provide modestly greater resolution and resolving power, an observation we tentatively attribute to their relatively uniform fields and minimal low-field regions.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

On electrolyte wetting through lithium-ion battery separators

The wettability by electrolyte is a critical characteristic of lithium-ion battery separators since electrolyte absorption is essential for ionic transport. Most importantly, fast absorption of electrolyte facilitates the electrolyte filling and wetting processes during the battery assembly. However, theoretical or experimental investigation of separator wettability has rarely been reported, and thus very little quantitative data can be found in the existing literature. Here, innovative experimental techniques and associated analytical models have been developed to fully characterize the electrolyte wetting behavior through battery separators. Both in-plane and through-plane imbibition processes are investigated. The results show that, electrolyte needs significantly longer time to wet separators than it does for commercial electrodes. The wetting rate depends significantly on the pore size, porosity, and micro-structure of the separators. Electrolyte in-plane wetting is only observed in the separators manufactured by the wet process. Increasing separator porosity and pore size is shown to be substantially increasing through-plane wetting rate. In addition, ceramic coating is shown to increase in-plane wetting but retard through-plane wetting.

25 ENERGY STORAGE↗

Method and apparatus for ion mobility separations utilizing alternating current waveforms

Methods and apparatuses for ion manipulations, including ion trapping, transfer, and mobility separations, using traveling waves (TW) formed by continuous alternating current (AC) are disclosed. An apparatus for ion manipulation includes a surface to which are coupled a first plurality of continuous electrodes and a second plurality of segmented electrodes. The second plurality of segmented electrodes is arranged in longitudinal sets between or adjacent to the first plurality of electrodes. An RF voltage applied to adjacent electrodes of the first plurality of electrodes is phase shifted by approximately 180° to confine ions within the apparatus. An AC voltage waveform applied to adjacent electrodes within a longitudinal set of the second plurality of segmented electrodes is phase shifted on the adjacent electrodes by 1°-359° to move ions longitudinally through the apparatus for separation.

Garimella, Venkata B. S.↗

Method and apparatus for ion mobility separations utilizing alternating current waveforms

Methods and apparatuses for ion manipulations, including ion trapping, transfer, and mobility separations, using traveling waves (TW) formed by continuous alternating current (AC) are disclosed. An apparatus for ion manipulation includes a surface to which are coupled a first plurality of continuous electrodes and a second plurality of segmented electrodes. The second plurality of segmented electrodes is arranged in longitudinal sets between or adjacent to the first plurality of electrodes. An RF voltage applied to adjacent electrodes of the first plurality of electrodes is phase shifted by approximately 180° to confine ions within the apparatus. An AC voltage waveform applied to adjacent electrodes within a longitudinal set of the second plurality of segmented electrodes is phase shifted on the adjacent electrodes by 1°-359° to move ions longitudinally through the apparatus for separation.

Garimella, Venkata B. S.↗

Understanding Cation Selectivity in Carbon Nanopores with Hybrid First-Principles/Continuum Simulations: Implications for Water Desalination and Separation Technologies

Understanding ion adsorption in porous carbons is crucial for a range of technologies, including water desalination and energy storage. In this work, we combined density functional theory with a continuum solvation model to investigate thermodynamics and kinetics of the adsorption process of alkali metal ions from aqueous solutions into carbon nanopores with different sizes and geometries. We found that cations with a larger ionic radius are more favorable to enter the nanopores because of a lower energy penalty of dehydration. In addition, the pore size and geometry were found to have a significant impact on the ion–pore interaction under confinement and cation selectivity. Our study highlights a complex interplay among nanopore geometry, ion size, and hydration on the cation adsorption selectivity, suggesting that tuning the porosity could represent a general strategy for improving ion separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Multiple-Species Cyclotron Ion Source

Use of pure isotope 86Kr instead of natural krypton in multiple-species ion source enables source to produce krypton ions separated from argon ions by tuning cylcotron with which source used. Addition of capability to produce and separate krypton ions at kinetic energies of 150 to 400 MeV necessary for simulation of worst-case ions occurring in outer space.

Soli, George A.↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗