Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion trap mass spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

It's a Trap! A Review of MOMA and Other Ion Traps in Space or Under Development

Since the Viking Program, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, including (from the inner to outer reaches): Venus (Pioneer); our moon (LADEE); Mars (Viking, Phoenix, and Mars Science Laboratory); and, Saturns largest moon Titan (Cassini-Huygens). More recently, however, ion trap mass spectrometer (ITMS) instruments have found a niche as smaller, versatile alternatives to traditional quadrupole mass analyzers, capable of in situ characterization of planetary environments and the search for organic matter. For example, whereas typical QMS systems are limited to a mass range up to 500 Da and normally require multiple RF frequencies and pressures of less than 10(exp -6) mbar for optimal operation, ITMS instruments commonly reach upwards of 1000 Da or more on a single RF frequency, and function in higher pressure environments up to 10(exp -3) mbar.

ion trap↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

Evaluating Linear Ion Trap for MS3-Based Multiplexed Single-Cell Proteomics

There is a growing demand to develop high-throughput and high-sensitivity mass spectrometry methods for single-cell proteomics. The commonly used isobaric labeling-based multiplexed single-cell proteomics approach suffers from distorted protein quantification due to co-isolated interfering ions during MS/MS fragmentation, also known as ratio compression. We reasoned that the use of MS3-based quantification could mitigate ratio compression and provide better quantification. However, previous studies indicated reduced proteome coverages in the MS3 method, likely due to long duty cycle time and ion losses during multilevel ion selection and fragmentation. Here, in this paper, we described an improved MS acquisition method for MS3-based single-cell proteomics by employing a linear ion trap to measure reporter ions. We demonstrated that linear ion trap can increase the proteome coverages for single-cell-level peptides with even higher gain obtained via the MS3 method. The optimized real-time search MS3 method was further applied to study the immune activation of single macrophages. Among a total of 126 single cells studied, over 1200 and 1000 proteins were quantifiable when at least 50 and 75% nonmissing data were required, respectively. Our evaluation also revealed several limitations of the low-resolution ion trap detector for multiplexed single-cell proteomics and suggested experimental solutions to minimize their impacts on single-cell analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature Mass Spectrometers on Space and Planetary Missions

Space flight mass spectrometers contribute our understanding of the origin and evolution of our solar system and even of life itself. This fundamental role has motivated increasing interest in miniature mass spectrometry for planetary missions. Several remarkable new instruments are en route or under development to investigate the composition of planetary bodies such as Mars and comets. For instance, the Sample Analysis at Mars (SAM) suite on the 2009 Mars Science Laboratory (MSL) mission includes a quadrupole mass spectrometer with a sophisticated gas processing system as well as pyrolysis and chemical derivatization protocols for solid samples. Future missions will require even lighter, lower power, and yet more capable mass spectrometers, particularly to analyze samples in situ on planetary surfaces. We have been developing laser-based mass spectrometers for elemental and organic/molecular analysis of rock, ice, or fine particle samples. These typically use time-of-flight (TOF) mass analyzers, which are readily miniaturized and can detect both atomic species and complex organics that occur in a variety of planetary materials. For example, nonvolatile polycyclic aromatic hydrocarbons and kerogen-like macromolecular carbon are found in some carbonaceous meteorites, which derived from asteroid parent bodies. A single focused laser pulse is able to volatilize and ionize some of these compounds for direct TOF analysis. While this is possible without any sample preparation or contact, sensitivity and quantitative performance can improve significantly with some sample handling. As such we have also been examining robotic mechanisms and protocols to accompany space flight mass spectrometers. In addition, sensors in early development may significantly improve these capabilities, via use of techniques such as switchable polarity, ambient pressure, or resonant ionization; tandem mass spectrometry (TOF or ion trap); and chemical imaging.

Brinckerhoff, William↗

Monitoring of space station life support systems with miniature mass spectrometry and artificial intelligence

The combination of quadrupole ion trap tandem mass spectroscopy with artificial intelligence is a promising approach for monitoring the performance of the life support systems in the space station. Such an analytical system can provide the selectivity, sensitivity, speed, small size, and decision making intelligence to detect, identify, and quantify trace toxic compounds which may accumulate in the space station habitat.

Yost, Richard A.↗

Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer

Miniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro-GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow-rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one-twentieth of those of commercial off-the-shelf systems. Potential applications are to spacecraft cabin-air monitoring, robotic planetary exploration and trace-species detection for residual gas analysis and environmental monitoring.

Miniaturization/instrumentation/methods↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold ion beam in a storage ring as a platform for large-scale quantum computers and simulators: Challenges and directions for research and development

The purpose of this paper is to evaluate the possibility of constructing a large-scale storage-ring-type ion-trap system capable of storing, cooling, and controlling a large number of ions as a platform for scalable quantum computing (QC) and quantum simulations. In such a trap, the ions form a crystalline beam moving along a circular path with a constant velocity determined by the frequency and intensity of the cooling lasers. In this paper, we consider a large leap forward in terms of the number of ions that serve as qubits in QC, from fewer than 100 available in state of the art linear ion-trap devices today to an order of 10 5 crystallized ions in the storage-ring setup. This new trap design unifies two different concepts: the storage rings of charged particles and the linear ion traps used for QC and mass spectrometry. In this paper, we use the language of particle accelerators to discuss the ion state and dynamics. We outline the differences between the above concepts, analyze challenges of the large ring with a revolving chain of ions, and propose goals for the research and development required to enable future quantum computers with 1000 times more qubits than available today. The challenge of creating such a large-scale quantum system while maintaining the necessary coherence of the qubits and the high fidelity of quantum logic operations is significant. Performing analog quantum simulations may be an achievable initial goal for such a device. Quantum calculations and simulations of complex quantum systems will move forward both the fundamental science and the applied research. Nuclear and particle physics, many-body quantum systems, lattice gauge theories, and nuclear structure calculations are just a few examples in which a large-scale quantum simulation system will become a very powerful tool to move forward our understanding of nature.

36 MATERIALS SCIENCE↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D-printed micro ion trap technology for quantum information applications

Trapped-ion applications, such as in quantum information processing1, precision measurements, optical clocks and mass spectrometry, rely on specialized high-performance ion traps. The last three of these applications typically use traditional machining to customize macroscopic 3D Paul traps, whereas quantum information processing experiments usually rely on photolithographic techniques to miniaturize the traps and meet scalability requirements. Using photolithography, however, it is challenging to fabricate the complex 3D electrode structures required for optimal confinement. Here, in this work, we demonstrate a high-resolution 3D printing technology based on two-photon polymerization (2PP) that is capable of fabricating large arrays of high-performance miniaturized 3D traps. We show that 3D-printed ion traps combine the advantages, such as strong radial confinement, of traditionally machined 3D traps with on-chip miniaturization. We trap calcium ions in 3D-printed ion traps with radial trap frequencies ranging from 2 MHz to 24 MHz. The tight confinement eases ion cooling requirements and allows us to implement high-quality Rabi oscillations with Doppler cooling only. Also, we demonstrate a two-qubit gate with a Bell-state fidelity of 0.978 ± 0.012. With 3D printing technology, the design freedom is greatly expanded without sacrificing scalability and precision, so that ion trap geometries can be optimized for higher performance and better functionality.

quantum information↗

Collision-Induced Dissociation at TRIUMF's Ion Trap for Atomic and Nuclear science

The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. Furthermore, this is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Mass measurement of 27 P to constrain type-I x-ray burst models and validate the isobaric multiplet mass equation for the $A = 27, T = \frac{3}{2}$ isospin quartet

Background: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in rp process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the rp process path. Purpose: Perform a precise atomic mass measurement of 27 P. Use this new measurement to calculate rp process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. Use the mass measurement of 27 P to validate the isobaric multiplet mass equation (IMME) for the A = 27 T = 3/2 isospin quartet which 27 P belongs to. Method: High-precision Penning trap mass spectrometry utilizing the time-of-flight ion cyclotron resonance technique was used to determine the atomic mass of 27 P. The MESA code (Modules for Experiments in Stellar Astrophysics) was then used to simulate x-ray bursts using a one-dimensional multizone model to produce updated light curves. Results: The mass excess of 27 P was measured to be –670.7(6) keV, a 14-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). The 26 Si(p, $γ$) 27 P– 27 P($γ$, p) 26 Si rate equilibrium has been determined to a higher precision based on the precision mass measurement of 27 P. x-ray burst light curves were produced with the MESA code using the new reaction rates. Changes in the mass of 27 P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. Conclusion: The mass of 27 P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the IMME has been validated for the A = 27, T = 3/2 quartet. The normal quadratic form of the IMME using the latest data yields a reduced $χ$ 2 of 2.9. Finally, the cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Source Design and Performance Characterization

The Mars Organic Molecule Analyzer (MOMA), a dual-source, ion trap-based instrument capable of both pyrolysis-gas chromatography mass spectrometry (pyr/GC-MS) and laser desorption/ionization mass spectrometry (LDI-MS), is the core astrobiology investigation on the ExoMars rover. The MOMA instrument will be the first spaceflight mass analyzer to exploit the LDI technique to detect refractory organic compounds and characterize host mineralogy; this mode of analysis will be conducted at Mars ambient conditions. In order to achieve high performance in the Martian environment while keeping the instrument compact and low power, a number of innovative designs and components have been implemented for MOMA. These include a miniaturized linear ion trap (LIT), a fast actuating aperture valve with ion inlet tube, and a Microelectromechanical System (MEMS) Pirani sensor. Advanced analytical capabilities like Stored Waveform Inverse Fourier Transform (SWIFT) for selected ion ejection and tandem mass spectrometry (MS/MS) are realized in LDI-MS mode, and enable the isolation and enhancement of specific mass ranges and structural analysis, respectively. We report here the technical details of these instrument components as well as system-level analytical capabilities, and we review the applications of this technology to Mars and other high-priority targets of planetary exploration.

Xiang Li↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗