At least 37 records · Page 2

Effect of Oil Viscosity and Impact of Ionic Liquid Additive on Electrically Induced Pitting in Rolling Contact

Electrically induced bearing damage (EIBD) is a growing concern in electric drivetrains, where electrical discharge currents generate localized pitting that accelerates wear and premature failure. While ionic liquids (ILs) have shown promise as lubricant additives due to their natural physical adsorption, strong capabilities of tribofilm formation, and high molecular tunability, their role in mitigating EIBD is little known. This gap is especially evident because lubricant viscosity and film thickness affect discharge behavior, and additive performance in these regimes has not been well explored. In this study, tribological tests were performed using a ball-on-disk pure rolling-contact system under an applied voltage on polyalphaolefin oils of three viscosities (4, 10, and 150 cSt measured at 100 °C), with and without the addition of a phosphonium-phosphate IL. Surface damage was analyzed using scanning electron microscopy (SEM) and stylus profilometry. Damage quantification was based on pit morphology analysis of SEM images. The results provide new insights into how oil viscosity governs the discharge behavior and how an IL additive could influence the pit formation. While viscosity seems to play a significant role, an IL additive shows potential to reduce EIBD and deserves further study.

electrically induced bearing damage (EIBD)↗

An Interfacial Engineering Approach toward Operation of a Porous Solid Electrolyte CO 2 Electrolyzer

Waste CO 2 can be repurposed as a carbon feedstock for synthesizing valuable chemicals via CO 2 electrolysis. Porous solid electrolyte (PSE) CO 2 electrolysis has been demonstrated as an economically viable method to produce high purity products. This work applies an interfacial engineering approach to determine key factors to improve performance in PSE CO 2 electrolyzers. We standardize the assembly by binding the ionic resin into an ionomer wafer and utilize Computational Fluid Dynamics (CFD) to design gaskets for uniform fluid flow. Here, we employ the distribution of relaxation times (DRT) method to determine that anionic-conducting interfaces are the primary contributor to energy losses. To address this, we demonstrate that enhancing the contact between the cathode and the anion exchange membrane (AEM) and the AEM-ionic resin interface allows for low overpotential in deionized water operation.

09 BIOMASS FUELS↗

Self-generated electrokinetic flows from active-charged boundary patterns

We develop a hydrodynamic description of self-generated electrolyte flow in capillaries whose bounding walls feature nonuniform distributions of charge nonuniform active ionic fluxes. The hydrodynamic velocity arising in such a system has components that are forbidden by symmetry in the absence of charge and fluxes. However, when these two boundary mechanisms are simultaneously present, they can lead to a symmetry broken state where steady flows with both unidirectional and circulatory components emerge. We show that these flow states arise when modulated boundary patterns of charge and fluxes are offset by a flux-charge phase difference, which is associated with the separation between sites of their peak densities on the wall. Mismatch in diffusivity of cationic and anionic species can modify the flow states and becomes an enhancing factor when fluxes of both ion species are being produced together at the same site. We demonstrate that this mechanism can be realized with a microfluidic generator that is powered by enzyme-coated patches that catalyze reactants in the solution to produce fluxes of ions. The local ionic elevation or depletion, which disrupts a nonuniform double layer, promotes self-induced gradients yielding persistent body forces to generate bulk fluid motion. Our work quantifies a boundary-driven mechanism behind self-sustained electrolyte flow in confined environments that exists without any external bulk-imposed fields or gradients. It provides a theoretical framework for understanding the combined effect of active and charged boundaries that are relevant in biological or soft matter systems, and can be utilized in electrofluidic and iontronic applications.

active matter↗

Minimizing Toxicity and Optimizing Lubricity of Ionic Liquids for Eco-Friendly Lubrication

As much as 60 million liters of lubricating fluids end up in the environment annually, and thus, the environmental impact of lubricants is increasingly recognized in addition to meeting the rheological and tribological requirements. Although US Environmental Protection Agency-approved environmentally acceptable base fluids are available, there is a lack of additives that are both nontoxic and effective in wear protection. Here, this study reports the successful development of a new class of ionic liquids (ILs) with demonstrated significantly lower aquatic toxicity and superior friction reduction and wear protection capabilities compared with a commercial lubricant additive and some ILs reported in the literature. Specifically, ammonium phosphate and phosphonium phosphate ILs with four-carbon alkyls have been identified with balanced oil solubility, thermal stability, toxicity, and lubricity, which provide fundamental insights for future development of eco-friendly ILs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rheology characterization of ionic liquids under high pressure and high temperature

Ionic liquids (ILs) are liquid salts that exist at or below ambient temperatures and are composed of ion pairs. They offer promising alternatives to toxic, hazardous, highly flammable, and volatile solvents in various applications such as solution preparation, dispersion, gel formation, composites, and polymer melts. ILs possess unique and interesting characteristics, including excellent chemical and thermal stability and low vapor pressures. Understanding the rheological properties of ILs is essential to optimizing IL performance. This paper presents a comparative analysis of the rheological properties of two ionic liquids, Nsingle bondHexylpyridinium tetrafluoroborate (HPyBF4) and Nsingle bondHexylpyridinium bromide (HPyBr), under different shear rates, temperatures, and pressures. Rheological measurements were performed under varying controlled pressure and temperature conditions. The experimental investigation covered a pressure range of 689–12,411 kPa [100–1800 psi] and a temperature range from room temperature up to 522 kelvin (K) [480°F]. The primary objective is to explore and compare the flow behavior and viscoelastic characteristics of HPyBF4 and HPyBr under high-pressure and high-temperature conditions. The experimental data showed that HPyBF4 and HPyBr exhibited shear-thinning behavior, and pressure had an insignificant effect on rheology compared to the temperature effect. Under the same testing conditions, HPyBr showed higher shear stress and viscosity than HPyBF4. This research significantly contributes to the improved understanding of the rheological behavior of these specific ionic liquids and their suitability for diverse industrial and scientific applications, particularly in high-pressure and high-temperature environments.

15 GEOTHERMAL ENERGY↗

Tuning the dynamics of imidazolium-based ionic liquids via hydrogen bonding. I. The viscous regime

Combining results from impedance spectroscopy and oscillatory shear rheology, this study focuses on the relation between the mass and charge flows and on how these are affected by the H-bonding in viscous ionic liquids (ILs). In particular, we compare the relaxational behaviors of the paradigmatic IL 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMIM-TFSI) and its OH-functionalized counterpart 1-(2-hydroxyethyl)-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (OHEMIM-TFSI). Our results and their analysis demonstrate that the presence of cationic OH-groups bears a strong impact on the overall dynamics of OHEMIM-TFSI, although no signatures of suprastructural relaxation modes could be identified in their dielectric and mechanical responses. To check whether at the origin of this strong variation is the H-bonding or merely the difference between the corresponding cation sizes (controlling both the hydrodynamic volume and the inter-charge distance), the present study includes 1-propyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (PMIM-TFSI), mixtures of EMIM-TFSI and PMIM-TFSI with lithium bis(trifluoromethylsulfonyl)imide (Li-TFSI), and mixtures of OHEMIM-TFSI with PMIM-TFSI. Their investigation clearly reveals that the dynamical changes induced by H-bonding are significantly larger than those that can be attributed to the change in the ion size. Moreover, in the mixtures of OHEMIM-TFSI with PMIM-TFSI, a dilution of the OH-groups leads to strong deviations from ideal mixing behavior, thus highlighting the common phenomenological ground of hydroxy-functionalized ILs and other H-bonded liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimessenger measurements of the static structure of shock-compressed liquid silicon at 100 GPa

The ionic structure of high-pressure, high-temperature fluids is a challenging theoretical problem with applications to planetary interiors and fusion capsules. Here we report a multimessenger platform using velocimetry and angularly and spectrally resolved x-ray scattering to measure the thermodynamic conditions and ion structure factor of materials at extreme pressures. We document the pressure, density, and temperature of shocked silicon near 100 GPa with uncertainties of 6%, 2%, and 20%, respectively. The measurements are sufficient to distinguish between and rule out some ion screening models. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Ab-initio molecular dynamics study of eutectic chloride salt: MgCl2–NaCl–KCl

Ionic liquid materials are viable candidates as a heat transfer fluid (HTF) in a wide range of applications, notably within concentrated solar power (CSP) technology and molten salt reactors (MSRs). For next-generation CSP and MSR technologies that strive for higher power generation efficiency, a HTF with wide liquid phase range and energy storage capabilities is crucial. Studies have shown that eutectic chloride salts exhibit thermal stability at high temperatures, high heat storage capacity, and are less expensive than nitrate and carbonate salts. However, the experimental data needed to fully evaluate the potential of eutectic chloride salts as a HTF contender are scarce and entail large uncertainties. Considering the high cost and potential hazards associated with the experimental methods used to determine the properties of ionic liquids, molecular modeling can be used as a viable alternative resource. In this study, the eutectic ternary chloride salt MgCl 2 –NaCl–KCl is modeled using ab-initio molecular dynamics simulations (AIMDs) in the liquid phase. Using the simulated data, the thermophysical and transport properties of eutectic chloride salt can be calculated: density, viscosity, heat capacity, diffusion coefficient, and ionic conductivity. For an initial model validation, experimental pair-distribution function data were obtained from X-ray total scattering techniques and compared to the theoretical pair-distribution function. Additionally, theoretical viscosity values are compared to experimental viscosity values for a similar system. The results provide a starting foundation for a MgCl 2 –NaCl–KCl model that can be extended to predict other fundamental properties.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating the Impact of Redox Potential on the Corrosion of Q125, 316L, and C276 Steel in Low-Temperature Geothermal Systems

Time series experiments were used to explore the fluid redox impact on the corrosion of Q125, 316L, and C276 steels in low-ionic-strength and neutral water at temperature and pressure conditions associated with low-temperature geothermal systems. After exposing polished samples of each steel grade to an oxidizing (H2O2) and a reducing (Zn-doped) fluid for intervals of 24 h, 1 week, and 6 weeks, the atomic force microscopy results revealed general corrosion for Q125, while 316L and C276 exhibited pitting, crevice expansion, and edge attack corrosion. Secondary depositional features are frequently found as topographic highs, adjacent to pitting corrosion. These features may be identified as there is a very strong spatial correlation between the height retrace and phase retrace surface maps. All steels became progressively rougher over time after exposure to both fluids, while the corrosion rates were more complex. Samples exposed to the reducing fluid experienced an increase in the corrosion rate over time, while C276 and 316L experienced a decrease in the corrosion rate. Finally, a novel data validation technique was developed to address the intrinsic scalability of corrosion. The results indicate that the AFM scan area does not affect the measured surface roughness over nearly three orders of magnitude.

Bowman, Samuel (ORCID:000000021510174X)↗

Tube-in-tube ionic liquid heat exchanger employing a selectively permeable tube

A tube-in-tube heat exchanger utilizes a selectively permeable tube having a selective permeable layer to allow the refrigerant to transfer into an ionic liquid to generate heating or cooling. The ionic liquid then provides heating or cooling to a heat transfer fluid through a non-permeable layer or tube. The system may be configured as a shell and tube design, with the third fluid free to flow on the outside of the shell, or as a shell and tube-in-tube, with a central tube containing a first liquid, a second tube containing a second liquid, and an outer shell containing the third liquid. The selectively permeable tube may include an anion or cation selectively permeable layer and this layer may be supported by a support layer or tube.

Bahar, Bamdad↗

Tube-in-tube ionic liquid heat exchanger employing a selectively permeable tube

A tube-in-tube heat exchanger utilizes a selectively permeable tube having a selective permeable layer to allow the refrigerant to transfer into an ionic liquid to generate heating or cooling. The ionic liquid then provides heating or cooling to a heat transfer fluid through a non-permeable layer or tube. The system may be configured as a shell and tube design, with the third fluid free to flow on the outside of the shell, or as a shell and tube-in-tube, with a central tube containing a first liquid, a second tube containing a second liquid, and an outer shell containing the third liquid. The selectively permeable tube may include an anion or cation selectively permeable layer and this layer may be supported by a support layer or tube.

Bahar, Bamdad↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative mercury treatment technology options for the liquid waste system at the Savannah River Site: scoping studies

The Savannah River Site (SRS) Liquid Waste System (LWS) contains liquids, salts and sludges that are currently being processed into final wasteforms for disposition, specifically, waste glass for sludges, solids and liquids containing high levels of radioactivity, and saltstone grout for low activity decontaminated liquid solutions. The LWS also contains approximately 60,000 kg of mercury present in the following physical and chemical forms, specifically: a) ionic inorganic mercury, organomercury (e.g., methylmercury), and other minor components found in LWS fluids b) mercury solids such as oxides, hydroxides, amalgams sulfides and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury found in tank headspace gas and in evaporators. An effective and proactive management strategy of the mercury present in the LWS is needed to support processing of LWS wastes into glass and saltstone. Sustainable processing of the LAWS to completion requires mercury removal from the LWS at a rate of approximately 2,900 kg/yr. This removal can be accomplished through existing mercury treatment systems or newly implemented LWS “purge points”. The chemical speciation of mercury has emerged as the key factor that controls mercury behavior in the LWS. For example, past studies demonstrated that mercury speciation is adversely impacting the performance of existing removal systems so that significant levels of mercury are recycled from the Defense Waste Processing Facility (DWPF) back to the tank farm. Consequently, mercury concentrations have slowly increased in the LWS tank fluids over time. The presence of organo-mercury has also been identified as the cause of increased mercury leaching from saltstone. In response to these challenges, the Department of Energy (DOE) Office of Environmental Management (EM-TD) Technology Development Program has supported a series of scoping studies predicated on manipulating or controlling mercury speciation and mercury behaviors within the constraints of LWS waste chemistry and safety conditions. The intent of these studies was to rapidly triage potential technology options and develop a technically based go / no go recommendation for further work. This composite report presents the results of three scoping studies: 1) advanced photooxidation processes, 2) chemical reduction, and 3) mercury getters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large deviations of ionic currents in dilute electrolytes

Here, we evaluate the exponentially rare fluctuations of the ionic current for a dilute electrolyte by means of macroscopic fluctuation theory. We consider the fluctuating hydrodynamics of a fluid electrolyte described by a stochastic Poisson–Nernst–Planck equation. We derive the Euler–Lagrange equations that dictate the optimal concentration profiles of ions conditioned on exhibiting a given current, whose form determines the likelihood of that current in the long-time limit. For a symmetric electrolyte under small applied voltages, number density fluctuations are small, and ionic current fluctuations are Gaussian with a variance determined by the Nernst–Einstein conductivity. Under large applied potentials, the ionic current distribution is generically non-Gaussian. Its structure is constrained thermodynamically by Gallavotti–Cohen symmetry and the thermodynamic uncertainty principle.

Farhadi, Jafar [University of California, Berkeley↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗