Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionic resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Methods and systems for operating a redox flow battery system

A method of operating a redox flow battery, may include maintaining a positive electrode compartment pressure greater than a negative electrode compartment pressure, and maintaining a cross-over pressure less than a membrane break-through pressure, wherein the cross-over pressure equals the negative electrode compartment pressure subtracted from the positive electrode compartment pressure. In this way, ionic resistance across the separator can be maintained at a lower level by reducing gas bubbles trapped therein while reducing separator break-through, thereby increasing performance of the redox flow battery system.

25 ENERGY STORAGE↗

Bacterial Resistance Toward Antimicrobial Ionic Liquids Mediated by Multidrug Efflux Pumps

The effective elimination of foodborne pathogens through cleaning and disinfection measures is of great importance to the food processing industry. As food producers rely heavily on disinfectants to control pathogenic bacteria in their facilities, the increasing spread of tolerant, often even multidrug resistant, strains is of particular concern. In addition to efforts to prevent or at least reduce development and spread of strains resistant to disinfectants and sanitizers, there is an urgent need for new and effective antimicrobials. One new class of promising antimicrobials is ionic liquids (ILs), which have been reported to be effective against resistant strains as they interact with bacterial cells in multiple ways, but investigations of their effectivity against MDR bacteria or specific defense mechanisms are still limited. This study investigates the role of multidrug efflux pumps of the Resistance Nodulation-Division family (RND) on the resistance of bacterial pathogens Escherichia coli and Salmonella enterica serovar Typhimurium toward 10 antimicrobial active ILs. Results reveal that, while known structure–activity relationships (SARs), such as the side-chain effect, were found for all strains, antimicrobial ILs with one elongated alkyl side chain were significantly affected by the RND efflux pump, highlighting the importance of efflux pumps for future IL toxicity studies. In case of antimicrobial ILs with multiple side chains and different cationic head groups, two ILs were identified that were highly active against all investigated strains with little to no effect of the efflux pump. The results obtained in this study for RND efflux pumps can serve as a starting point for identifying and designing antimicrobial ILs as effective biocides against MDR bacteria.

59 BASIC BIOLOGICAL SCIENCES↗

Draft Genome Assemblies of Ionic Liquid-Resistant Yarrowia lipolytica PO1f and Its Superior Evolved Strain, YlCW001

Adaptive laboratory evolution of Yarrowia lipolytica PO1f in the benchmark ionic liquid (IL; 1-ethyl-3-methylimidazolium acetate) produced a superior IL-tolerant microorganism, strain YlCW001. In this work, we report the genome sequences of PO1f and YlCW001 to explore the robustness of Y. lipolytica and its potential use as a microbial platform for producing fuels and chemicals.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding resistances in capacitive deionization devices

The desalination characteristics of capacitive deionization (CDI) are significantly impacted by the cell resistance. Here we apply electrochemical impedance spectroscopy (EIS) to analyze the resistive properties of a CDI device, which include EIS measurements on a complete assembled cell (in two wire mode) and EIS measurements with additional contacts to decouple electrode/electrolyte and contact impedances (four wire mode). These measurements shed light on the interface between current collector and electrode as well as the internal capacitive and resistive elements of the cell. With two-wire and four-wire EIS measurements, we find that the often observed high-frequency arc(s) in the impedance spectra can be due to contact effects and/or an internal ionic-transfer resistance that is locally in parallel with macropore wall capacitance. In some cases, the two associated arcs in the Nyquist plot are overlapping and present simultaneously, making their identification in the EIS spectra difficult unless both two-wire and four-wire measurements are made. Despite causing a large high-frequency arc in the Nyquist plot, we find that the apparent internal ionic-transfer resistance is negligible compared to the resistances of the electrode, separator, and external electronic components. Here, an investigation of the contact impedance between the electrode and current collector reveals a parallel RC arc that can grow over time if an improper material is used (e.g., titanium). In our system, the electrode ionic resistance dominates the total Ohmic power dissipation, which has implications for scale-up of CDI systems and future improvements of cell design.

36 MATERIALS SCIENCE↗

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

Phosphorus replenishment to improve the contact resistivity of light-induced Al contacts on Si solar cells

A method to repair laser-induced phosphorus loss from the n-type emitter of Si solar cells during light-induced Al plating is demonstrated. The ability to add a water-reactive phosphorus compound, PCl 5 , into the Al plating bath gives a unique advantage to Al over Cu for front contacts on Si solar cells. The contact resistivity between light-induced Al and Si emitter is reduced to as low as 0.1 mΩ-cm 2 . Cyclic voltammetry performed on a plating bath composed of 81 wt% 1-ethyl-3-methylimidazolium tetrachloroaluminate, 19 wt% AlCl 3 , and 0.2 wt% PCl 5 reveals multiple reduction reactions of PCl 5 , although incomplete decomposition of PCl 5 is possible. A decrease in nucleation loop size during cyclic voltammetry is also observed suggesting that PCl 5 , while being consumed, modifies the growth mechanism during Al plating. Structural analysis confirms that the addition of PCl 5 produces an Al film which is levelized and compact. Here, a pulsed voltage profile coupled with chemical analysis verifies that phosphorus incorporation is electrolytically activated and is likely the cause for the low contact resistivity.

14 SOLAR ENERGY↗

A Direct Ammonia Fuel Cell with a KOH-Free Anode Feed Generating 180 mW cm −2 at 120 °C

The motivations to operate the direct ammonia fuel cell (DAFC) with no addition of aqueous base, include facilitated fuel management and prevention of corrosion and shunt currents in the DAFC stack. We describe here a polymer electrolyte DAFC, operating at a cell temperature (T cell ) of 120 °C on ammonia and water alone as anode feed, that demonstrated peak power of 180 mW cm −2 —a record for this type of fuel cell. We offer a detailed analysis of polarization curves recorded for PE-DAFCs in the T cell range of 60 °C–120 °C, allowing to estimate the effects of KOH-free operation on the ionic and faradaic resistances, R i and R F , that determine together the value of R app , CL – an , the apparent resistance of the anode catalyst layer. The latter resistance drops ten times between 60 °C and 120 °C as result mainly of the drop in R F . Consequently, DAFC performance at T cell > 100 °C improves substantially, including the cell performance on a KOH-free anode feed. The demsontrated performance levels reported here for KOH-free DAFCs support further development of this type of ammonia/air fuel cells.

Achrai, Ben↗

Effects of Strain Rate and Temperature on the Mechanical Properties of Simulated Silica Ionogels

Ionogels are hybrid materials formed by impregnating the pore space of a solid matrix with a conducting ionic liquid. By combining the properties of both component materials, ionogels can act as self-supporting electrolytes in Li batteries. In this study, molecular dynamics simulations are used to investigate the dependence of mechanical properties of silica ionogels on solid fraction, temperature, and pore width. Comparisons are made with corresponding aerogels. We find that the solid matrix fraction increases the moduli and strength of the ionogel. This varies nonlinearly with temperature and strain rate, according to the contribution of the viscous ionic liquid to resisting deformation. Additionally, owing to the temperature and strain sensitivity of the ionic liquid viscosity, the mechanical properties approach a linear mixing law at high temperature and low strain rates. The median pore width of the solid matrix plays a complex role, with its influence varying qualitatively with deformation mode. Narrower pores increase the relevant elastic modulus under shear and uniaxial compression but reduce the modulus obtained under uniaxial tension. Conversely, shear and tensile strength are increased by narrowing the pore width. All of these pore size effects become more pronounced as the silica fraction increases. Pore size effects, similar to the effects of temperature and strain rate, are linked to the ease of fluid redistribution within the pore space during deformation-induced changes in the geometry of the pores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Addressing Spacer Channel Resistances in MCDI Using Porous and Pliable Ionic Conductors

Membrane capacitive deionization (MCDI) is a unique electrochemical separations platform that allows for energy recovery during electrode regeneration. Similar to other electrochemical separation technologies producing deionized water (e.g. electrodialysis), ohmic resistances in the spacer channel significantly hampers the performance and energy efficiency of the process. This work devised a series of ionomer coated nylon mesh nets to address spacer channel resistances in MCDI. Under constant current operation, the ionomer coated nylon meshes displayed a 300 mV lower cell voltage rise during deionization while sustaining the same deionization rate. Furthermore, energy recovery was improved by 1.4x to 5.5x depending on the saline feed concentration. The lower cell voltage rise during deionization combined with the greater energy recovery with ionomer coated meshes resulted in energy normalized adsorbed salt (ENAS) values that were 2x to 3x greater. Addressing the spacer channel resistances in MCDI allowed for 8% to 19% increase in current density without the cell voltage exceeding 1.6 V—the upper bound set for mitigating parasitic reactions. Operating at higher current density leads to smaller MCDI units for a given deionization requirement and has implications for reducing the capital costs of the MCDI unit.

Palakkal, Varada Menon (ORCID:0000000317038323)↗

Catalyst Layer Resistance and Utilization in PEM Electrolysis

Improving utilization, performance, and stability of low iridium (Ir)-loaded anodes is a key goal to enable widespread adoption of polymer electrolyte membrane water electrolysis (PEMWE) for clean hydrogen production. A potential limitation is high ionic or electronic resistance of the anode catalyst layer, which leads to poor catalyst utilization, increased voltage losses, and high local overpotentials that can accelerate degradation. While catalyst layer resistance is relatively well-understood in fuel cells and other porous electrode systems, characterization of these effects is not as well established in PEMWE research. Here we present in-situ methods for measuring catalyst layer resistance in electrolysis cells using a non-faradaic H 2 /H 2 O condition as well as methods for calculating the associated voltage losses. These methods are applied to anode catalyst layers based on IrO 2 nanoparticles as well as dispersed nano-structured thin film (NSTF) Ir catalysts. Trends with anode catalyst loading and interactions between the porous transport layer and catalyst layer are investigated for IrO 2 anodes. Post-mortem microscopic analysis of durability-tested anodes is also presented, showing uneven degradation of the catalyst layer caused by catalyst layer resistance.

08 HYDROGEN↗

A systematic study of lanthanide titanates (A 2 Ti 2 O 7 ) chemical durability: corrosion mechanisms and control parameters

Dense lanthanide titanates ranging from La 2 Ti 2 O 7 to Yb 2 Ti 2 O 7 were synthesized by spark plasma sintering with similar micro-sized microstructure, and their chemical durability and degradation mechanisms were investigated by semi-dynamic leaching tests. Different corrosion mechanisms from incongruent to congruent dissolution were observed with preferential elemental releases of lanthanides in A 2 Ti 2 O 7 (A = La to Gd) and Ti in Er 2 Ti 2 O 7 and Yb 2 Ti 2 O 7 . Initial leaching was controlled by surface dissolution and long-term dissolution shifted to a diffusion-controlled mechanism for titanate pyrochlores from Sm 2 Ti 2 O 7 to Yb 2 Ti 2 O 7 . Both short-term and long-term leaching rates decreased from La 2 Ti 2 O 7 to Yb 2 Ti 2 O 7 , and materials became more corrosion resistant with decreasing ionic radius ratios of the rare-earth elements and titanium. Amorphous passivation films of several nm-thick enriched with Ti formed on the surfaces of the corroded materials, and the formation mechanisms were governed either by surface reorganization with preferential release of lanthanides or dissolution-precipitation from saturated bulk solutions with preferential release of titanium. Finally, these results demonstrate that the ionic size plays a dominant role in determining chemical durability of lanthanide titanates and a strong correlation is established among chemical composition/structural variation, passivation film formation and corrosion mechanisms, and materials chemical durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simply Fabricatable Reference Electrode for Studying Li Metal Interfaces Operando

Reference electrodes are essential for studying Li metal interfaces, yet their integration into coin cells remains challenging due to geometric constraints and assembly complexity. Here, we present a simple three-electrode coin cell design in which a thin Cu film is evaporated directly onto a trilayer PP/PE/PP separator, forming a conductive and flexible in situ current collector. The microporous Cu preserves separator porosity and pressure uniformity, avoiding artifacts introduced by wire- or mesh-type references. It is easily activated by Li plating and provides stable potentials for over 10 days in ether-based electrolytes without affecting Coulombic efficiency (>99%) or Li deposition morphology. Operando measurements using this design reveal electrode-specific impedance evolution and voltage responses otherwise obscured in two-electrode setups, uncovering a correlation between the SEI resistance and electrolyte ionic conductivity. This microporous Cu reference electrode offers a robust and accessible platform for characterizing reactive interfaces under realistic cycling conditions.

Sacci, Robert [ORNL] (ORCID:0000000200735221)↗

Theoretical Analysis of Critical Conditions for Crack Formation and Propagation, and Optimal Operation of SOECs

A theoretical analysis on crack formation and propagation was performed based on the coupling between the electrochemical process, classical elasticity, and fracture mechanics. The chemical potential of oxygen, thus oxygen partial pressure, at the oxygen electrode-electrolyte interface ( μ O 2 OE∣El ) was investigated as a function of transport properties, electrolyte thickness and operating conditions (e.g., steam concentration, constant current, and constant voltage). Our analysis shows that: a lower ionic area specific resistance (ASR), r i O E , and a higher electronic ASR ( r e O E ) of the oxygen electrode/electrolyte interface are in favor of suppressing crack formation. The μ O 2 O E ∣ E l , thus local pO 2 , are sensitive towards the operating parameters under galvanostatic or potentiostatic electrolysis. Constant current density electrolysis provides better robustness, especially at a high current density with a high steam content. While constant voltage electrolysis leads to greater variations of μ O 2 O E ∣ E l . Constant current electrolysis, however, is not suitable for an unstable oxygen electrode because μ O 2 O E ∣ E l can reach a very high value with a gradually increased r i O E . A crack may only occur under certain conditions when p O 2 T P B > p c r .

42 ENGINEERING↗

A novel equivalent circuit for GDC-based solid oxide cells considering the variations of cell resistances under load

Regarding the mixed ionic-electronic conductive electrolytes, there are several constant assumptions about cell resistances and transference numbers. In this work, the charge transport frameworks of mixed conductive SOCs are comprehensively illustrated. And the independent external current density is introduced into the equivalent circuit for considering the variations of cell resistances under load. The updated expressions of cell resistances together with transference numbers are deduced rigorously based on the equivalent circuit. Electrolyte-supported NiO-GDC/GDC/LSCF cells are tested, and the experimental results validate the variations of cell resistances, especially for the polarization resistance. The comparisons show that electron hole resistances together with transference number calculated by the updated expressions are larger than those obtained by Liu’s method. More accurate transference number and cell resistances under load can be achieved by using the proposed method in this study.

25 ENERGY STORAGE↗

Direct Measurement of Crossover and Interfacial Resistance of Ion-Exchange Membranes in All-Vanadium Redox Flow Batteries

Among various components commonly used in redox flow batteries (RFBs), the separator plays a significant role, influencing resistance to current as well as capacity decay via unintended crossover. It is well-established that the ohmic overpotential is dominated by the membrane and interfacial resistance in most aqueous RFBs. The ultimate goal of engineering membranes is to improve the ionic conductivity while keeping crossover at a minimum. One of the major issues yet to be addressed is the contribution of interfacial phenomena in the influence of ionic and water transport through the membrane. In this work, we have utilized a novel experimental system capable of measuring the ionic crossover in real-time to quantify the permeability of ionic species. Specifically, we have focused on quantifying the contributions from the interfacial resistance to ionic crossover. The trade-off between the mass and ionic transport impedance caused by the interface of the membranes has been addressed. The MacMullin number has been quantified for a series of electrolyte configurations and a correlation between the ionic conductivity of the contacting electrolyte and the Nafion® membrane has been established. The performance of individual ion-exchange membranes along with a stack of various separators have been explored. We have found that utilizing a stack of membranes is significantly beneficial in reducing the electroactive species crossover in redox flow batteries compared to a single membrane of the same fold thickness. For example, we have demonstrated that the utilization of five layers of Nafion ® 211 membrane reduces the crossover by 37% while only increasing the area-specific resistance (ASR) by 15% compared to a single layer Nafion ® 115 membrane. Therefore, the influence of interfacial impedance in reducing the vanadium ion crossover is substantially higher compared to a corresponding increase in ASR, indicating that mass and ohmic interfacial resistances are dissimilar. We have expanded our analysis to a combination of commercially available ion-exchange membranes and provided a design chart for membrane selection based on the application of interest (short duration/high-performance vs. long-term durability). The results of this study provide a deeper insight into the optimization of all-vanadium redox flow batteries (VRFBs).

UV/Vis spectroscopy↗

Recent Developments and Challenges in Hybrid Solid Electrolytes for Lithium-Ion Batteries

Lithium-ion batteries (LIBs) have attracted worldwide research interest due to their high energy density and long cycle life. Solid-state LIBs improve the safety of conventional liquid-based LIBs by replacing the flammable organic electrolytes with a solid electrolyte. Among the various types of solid electrolytes, hybrid solid electrolytes (HSEs) demonstrate great promise to achieve high ionic conductivity, reduced interfacial resistance between the electrolyte and electrodes, mechanical robustness, and excellent processability due to the combined advantages of both polymer and inorganic electrolyte. This article summarizes recent developments in HSEs for LIBs. Approaches for the preparation of hybrid electrolytes and current understanding of ion-transport mechanisms are discussed. The main challenges including unsatisfactory ionic conductivity and perspectives of HSEs for LIBs are highlighted for future development. The present review provides insights into HSE development to allow a more efficient and target-oriented future endeavor on achieving high-performance solid-state LIBs.

25 ENERGY STORAGE↗

Mitigating Electronic Conduction in Ceria‐Based Electrolytes via External Structure Design

Doped ceria electrolytes are the state of the art low‐temperature solid oxide electrolytes because of their high ionic conductivity and good material compatibility. However, cerium tends to reduce once exposed to reducing environments, leading to an increase in electronic conduction and a decrease in efficiency. Here, the leakage current is mitigated in ceria‐based electrolytes by controlling the defect chemistry through an engineered cathode side microstructure. This functional layer effectively addresses the problematic electronic conduction issue in ceria‐based electrolytes without adding significant ohmic resistance and increases the ionic transference number to over 0.93 in a thin 20 µm ceria‐based electrolyte at 500 °C, compared to a of 0.8 for an unmodified one. Based on this design, solid oxide fuel cells (SOFCs) are further demonstrated with the remarkable peak power density of 550 mW at 500 °C and excellent stability for over 2000 h. This approach enables a potential breakthrough in the development of ceria‐based low‐temperature solid oxide electrolytes.

36 MATERIALS SCIENCE↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗