Search NASA⌕ Search

SEARCH · Search NASA

Results for “isolate pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of Orthogonal Efflux and Permeation Properties of Compounds Leads to the Discovery of New Efflux Pump Inhibitors

Optimization of compound permeation into Gram-negative bacteria is one of the most challenging tasks in the development of antibacterial agents. Two permeability barriers–the passive diffusion barrier of the outer membrane (OM) and active drug efflux–act synergistically to protect cells from the antibacterial action of compounds. In Escherichia coli (E. coli) and relatives, these two barriers sieve compounds based on different physicochemical properties that are defined by their interactions with OM porins and efflux pumps, respectively. In this study, we critically tested the hypothesis that the best substrates and inhibitors of efflux pumps are compounds that can effectively permeate the OM and are available at relatively high concentrations in the periplasm. For this purpose, we filtered a large subset of the ZINC15 database of commercially available compounds for compounds containing a primary amine, a chemical feature known to facilitate the uptake through E. coli general porins. The assembled library was screened by ensemble docking to AcrA, the periplasmic component of the AcrAB-TolC efflux pump, followed by experimental testing of the top predicted binders for antibacterial activities, efflux recognition, and inhibition. In this work, we found that the filtered primary amine library is a rich source of compounds with efflux-inhibiting activities and identified efflux pump inhibitors with novel chemical scaffolds effective against E. coli AcrAB-TolC and efflux pumps of multidrug-resistant clinical isolates of Acinetobacter baumannii. However, primary amines are not required for the recognition of compounds by efflux pumps and their efflux-inhibitory activities.

60 APPLIED LIFE SCIENCES↗

Widely tunable terahertz source based on intra-cavity frequency mixing in quantum cascade laser arrays

We demonstrate a compact monolithic terahertz source continuously tunable from 1.9 THz to 3.9 THz with the maximum peak power output of 106 μW at 3.46 THz at room temperature. The source consists of an array of 10 electrically tunable quantum cascade lasers with intra-cavity terahertz difference-frequency generation. To increase fabrication yield and achieve high THz peak power output in our devices, a dual-section current pumping scheme is implemented using two electrically isolated grating sections to independently control gain for the two mid-IR pumps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remediation of Irradiated Graphite Using Microorganisms Isolated from Oil Contaminated Soil - 19643

The deployment of nuclear energy globally is hindered by the fear cleared by nuclear reactor disasters such as the Chernobyl and Fukushima reactor meltdowns. Additionally, accumulation of radioactive waste globally will, in the near future, present a significant threat to humans and the environment. Notably, the majority of nuclear waste from the energy generation industry is generated as Low Level Waste (LLW) in which the small radioactive component renders the bulk of the waste unsuitable for conventional treatment and disposal. In the case of radioactive graphite, the small radioactive component comprising radiocarbon-14 (C-14) and metallic pollutants can be removed to allow safe disposal or reuse as of the graphite. In the current study, mixed-cultures of organisms isolated from oil contaminated sites showed potential of selective bioaccumulation of C-14 from a powdered C-12/C-14 graphite matrix. The study was conducted in a continuously mixed reactor (growth vessel) constructed from Pyrex panels (30 cm x 20 cm x 15 cm) with finely ground graphite as the principal carbon source (1500-2000 mg.L{sup -1}) and spikes of glucose (500 mg.L{sup -1} every 48 hours). The growth vessel was connected to a biofilter unit by submersible pump where particulate matter was isolated for further analysis. Results showed that approximately 68% more C-14 was released from ignited dry cells than from respiration product. C-14 accumulated in cells corrected using a trap filter system, with a marked decrease of C-14 in carbon dioxide than vegetative suspended cells in the main tank. The only mechanism that could account for the differential C-14 distribution between the liquid medium and cells was possible fractionation during uptake of carbon compounds. The discriminating factor suggested in this study is the kinetic isotope effect (KIE) which allows heavier atoms to have different affinities for reaction sites on catalysis and biocatalysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gating attosecond pulse train generation using multicolor laser fields

The process of high-order harmonic generation leads to the production of a train of attosecond-duration extreme ultraviolet (XUV) pulses, with one pulse emitted per optical half-cycle. For attosecond pump-probe experiments, a single, isolated attosecond pulse is preferable, requiring an almost continuous spectrum. We show experimentally and numerically that the addition of a second laser field, and later a third, at a noncommensurate frequency relative to the driving field can modify the subcycle shape of the electric field, leading to the appearance of additional spectral components between the usual odd harmonics and in some cases a quasicontinuum. We perform a parametric study of the frequency ratio between the two first laser fields, the result of which is in good agreement with theoretical selection rules. We also show numerically that using three laser frequencies from an optical parametric amplifier can achieve a single attosecond pulse from a 24-fs laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM 8

Groundwater beneath the M-Area HWMF is contaminated with chlorinated ethenes including trichloroethylene (TCE) and tetrachloroethylene (PCE). SRS operates a network of recovery wells designed to hydraulically contain and capture the high concentration VOC plume in the Lost Lake Aquifer Zone (LLAZ) (Figure 1). The recovery wells are connected to the M-1 Air Stripper and the system is permitted by the South Carolina Department of Environmental Control (SCDHEC) to operate at a total flow of 610 gpm. RWM 8, which is one of ten operational recovery wells, has historically operated at a flow rate of approximately 40 gpm. RWM 8 was installed with four separate 10-ft screens that spanned the LLAZ with a continuous gravel pack spaced as shown in Figure 2. The three uppermost screens are located within the LLAZ whereas the deepest screen is located within the middle sand of the Crouch Branch Confining Unit (CBCU). Area Closure Projects (ACP) installed a permanent packer in May 2019 to isolate the lowest screen from the pump with the goal being to target the zone of highest concentration in the LLAZ. ACP expressed concern that a substantial portion of the flow from RWM 8 comes from the lower screen. With this screen isolated from service, flow from the well may be below the desired operational envelope for the well. The reconfiguration of RWM 8 presented an opportunity to re-evaluate the performance characteristics of the well. Following placement of the packer and relocation of the pump, the well was redeveloped. To assess the effects of eliminating the lower screen, a step-drawdown test was planned. The purpose of this test was to establish new baseline well performance properties including specific capacity, well efficiency, and well loss coefficients. Data from the step-drawdown testing was also used to estimate a maximum pumping rate for RWM 8 under the new configuration. The setup for the step-drawdown test facilitated a subsequent constant rate aquifer pumping test aimed at determining aquifer hydraulic properties. Properties estimated for the LLAZ included transmissivity and storativity. Following shutdown of RWM 8, recovery data were also collected and analyzed to estimate aquifer properties. This report discusses the hydrologic tests conducted following the reconfiguration of RWM 8. The information provided in this report may serve as input to subsequent updates to the groundwater flow and contaminant transport model for A/M Area.

42 ENGINEERING↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Spin pumping from antiferromagnetic insulator spin-orbit-proximitized by adjacent heavy metal: a first-principles Floquet-nonequilibrium Green function study

Motivated by the recent experiment on spin pumping from sub-THz radiation-driven uniaxial antiferromagnetic insulator (AFI) MnF 2 into heavy metal (HM) Pt hosting strong spin-orbit (SO) coupling, we compute and compare pumped spin currents in Cu/MnF 2 /Cu and Pt/MnF 2 /Cu heterostructures. Recent theories of spin pumping by AFI have relied on simplistic Hamiltonians (such as tight-binding) and the scattering approach to quantum transport yielding the so-called interfacial spin mixing conductance (SMC), but the concept of SMC ceases to be applicable when SO coupling is present directly at the interface. In contrast, we use a more general first-principles quantum transport approach which combines noncollinear density functional theory with Floquet-nonequilibrium Green's functions in order to take into account: SO-proximitized AFI as a new type of quantum material, different from isolated AFI and brought about by AFI hybridization with adjacent HM layer; strong SO coupling at the interface; and evanescent wavefunctions penetrating from Pt or Cu into AFI layer to make its interfacial region conducting rather than insulating as in the isolated AFI. The DC component of pumped spin current $I_\mathrm{DC}^{S_z}$ vs. precession cone angle $\theta_{\boldsymbol{l}}$ of the Néel vector l of AFI does not follow putative $I^{S_z}_\mathrm{DC} \propto \sin^2 \theta_{\boldsymbol{l}}$, except for very small angles $\theta_{\boldsymbol{l}} \lesssim 10^\circ$ for which we define an effective SMC from the prefactor and find that it doubles from MnF2/Cu to MnF2/Pt interface. In addition, the angular dependence $I^{S_z}_\mathrm{DC}(\theta_{\boldsymbol{l}})$ differs for opposite directions of precession of the Néel vector, leading to twice as large SMC for the right-handed than for the left-handed chirality of the precession mode.

36 MATERIALS SCIENCE↗

Logical approach to tritium vacuum pump selection for fusion applications

Vacuum pumps have been used for tritium processing since the 1940s following the isolation of pure tritium. The largest problem facing tritium vacuum pumps is the tritium radioactive decay. The beta particles, recoil energy, and subsequent radical formations are detrimental to most carbon-based materials. Carbon materials, such as plastics, elastomers, carbon fiber, activated carbon, etc., react with tritium to form methane and in the process strip material from the carbonbased material. Other reactions can be self-catalyzing, as is the case with nitrogen and tritium forming tritiated ammonia at room temperature and pressure. Tritium also readily isotopically exchanges with surface -OH groups, increasing the amount of protium in the gas stream while creating a tritium holdup on the surface. Metals are the preferred material when working with tritium, but tritium will permeate into and through almost all metals at some point. The entrapped tritium can decay inside the metal, creating local helium distortions that can impact the structural properties above and beyond the hydrogen embrittlement issue tritium can cause.

Angelette, Lucas M. [Savannah River National Labor↗

Submersible pumping system with heat transfer mechanism

A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.

42 ENGINEERING↗

Modeling of the Reactor Core Isolation Cooling Response to Beyond Design Basis Operations - Interim Report

Efforts are being pursued to develop and qualify a system-level model of a reactor core isolation (RCIC) steam-turbine-driven pump. The model is being developed with the intent of employing it to inform the design of experimental configurations for full-scale RCIC testing. The model is expected to be especially valuable in sizing equipment needed in the testing. An additional intent is to use the model in understanding more fully how RCIC apparently managed to operate far removed from its design envelope in the Fukushima Daiichi Unit 2 accident. RCIC modeling is proceeding along two avenues that are expected to complement each other well. The first avenue is the continued development of the system-level RCIC model that will serve in simulating a full reactor system or full experimental configuration of which a RCIC system is part. The model reasonably represents a RCIC system today, especially given design operating conditions, but lacks specifics that are likely important in representing the off-design conditions a RCIC system might experience in an emergency situation such as a loss of all electrical power. A known specific lacking in the system model, for example, is the efficiency at which a flashing slug of water (as opposed to a concentrated jet of steam) could propel the rotating drive wheel of a RCIC turbine. To address this specific, the second avenue is being pursued wherein computational fluid dynamics (CFD) analyses of such a jet are being carried out. The results of the CFD analyses will thus complement and inform the system modeling. The system modeling will, in turn, complement the CFD analysis by providing the system information needed to impose appropriate boundary conditions on the CFD simulations. The system model will be used to inform the selection of configurations and equipment best suitable of supporting planned RCIC experimental testing. Preliminary investigations with the RCIC model indicate that liquid water ingestion by the turbine decreases the developed turbine torque; the RCIC speed then slows, and thus the pump flow rate to the RPV decreases. Subsequently, RPV water level decreases due to continued boiling and the liquid fraction flowing to the RCIC decreases, thereby accelerating the RCIC and refilling the RPV. The feedback cycle then repeats itself and/or reaches a quasi-steady equilibrium condition. In other words, the water carry-over is limited by cyclic RCIC performance degradation, and hence the system becomes self-regulating. The indications achieved to date with the system model are more qualitative than quantitative. The avenues being pursued to increase the fidelity of the model are expected to add quantitative realism. The end product will be generic in the sense that the RCIC model will be incorporable within the larger reactor coolant system model of any nuclear power plant or experimental configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

LOCA Analysis for the NIST Research Reactor

The research reactor (aka NBSR) at the National Institute of Standards and Technology (NIST) is a heavy water cooled, moderated, and reflected tank-type research reactor that operates at atmospheric pressure and a design power of 20 MW. Core power is generated in 30 fuel elements, each with 17 fuel plates in an upper section and a separate lower section. Power is removed using forced convection and heat exchangers in the cooling loop. The licensing analysis of the loss-of-coolant accident (LOCA) in the NBSR was addressed in the current Safety Analysis Report (SAR). The SAR discusses the low probability of a significant pipe break: 'the main piping is located in protected areas, system pressures are low, and flow rates are small so that wear is not an issue.' Therefore, the probability of a large break, including a double-ended guillotine break, is extremely low. For smaller breaks where the operator has time to take action, procedures are in place to 1) mitigate a loss of water by tripping pumps and closing control valves to isolate the reactor vessel after the falling water level in the vessel is detected by instrumentation, and 2) ensure that emergency cooling water continues to flow for as long as needed. The SAR also refers to an analysis of why there is sufficient water without forced cooling to cool the fuel elements (FEs) in a LOCA if the flow channels between two fuel plates (or a fuel plate and an outside plate) remain filled with water. That analysis was based on a flooding-limited critical power but assumed that reactor trip had taken place. A more recent study showed that some scenarios may lead to the draining of water from the coolant channels. In these cases, the cooling on the inside of the fuel element is from emergency cooling water that falls only along the inner surface of one of the side plates in the fuel elements; the remaining surfaces within the fuel element being exposed to gas. The analysis therein was done for both the present high-enriched uranium fuel (HEU) and the proposed low-enriched uranium fuel (LEU). The LOCA analyses done previously assumed that there is sufficient cooling during the short-term, i.e., before the water level reaches the top of the fuel plates and begins to drain from the coolant channels or before decay heat becomes low enough such that the flooding-limited critical power shows that there is no problem. The present study is to determine if that assumption is correct, i.e., to consider the situation immediately after the break, before and after reactor trip when the power is still relatively high.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

All-optical switching of an epsilon-near-zero plasmon resonance in indium tin oxide

Abstract Nonlinear optical devices and their implementation into modern nanophotonic architectures are constrained by their usually moderate nonlinear response. Recently, epsilon-near-zero (ENZ) materials have been found to have a strong optical nonlinearity, which can be enhanced through the use of cavities or nano-structuring. Here, we study the pump dependent properties of the plasmon resonance in the ENZ region in a thin layer of indium tin oxide (ITO). Exciting this mode using the Kretschmann-Raether configuration, we study reflection switching properties of a 60 nm layer close to the resonant plasmon frequency. We demonstrate a thermal switching mechanism, which results in a shift in the plasmon resonance frequency of 20 THz for a TM pump intensity of 70 GW cm −2 . For degenerate pump and probe frequencies, we highlight an additional two-beam coupling contribution, not previously isolated in ENZ nonlinear optics studies, which leads to an overall pump induced change in reflection from 1% to 45%.

36 MATERIALS SCIENCE↗

Probing Non-Equilibrium Pair-Breaking and Quasiparticle Dynamics in Nb Superconducting Resonators Under Magnetic Fields

We conducted a comprehensive study of the non-equilibrium dynamics of Cooper pair breaking, quasiparticle (QP) generation, and relaxation in niobium (Nb) cut from superconducting radio-frequency (SRF) cavities, as well as various Nb resonator films from transmon qubits. Using ultrafast pump–probe spectroscopy, we were able to isolate the superconducting coherence and pair-breaking responses. Our results reveal both similarities and notable differences in the temperature- and magnetic-field-dependent dynamics of the SRF cavity and thin-film resonator samples. Moreover, femtosecond-resolved QP generation and relaxation under an applied magnetic field reveals a clear correlation between non-equilibrium QPs and the quality factor of resonators fabricated by using different deposition methods, such as DC sputtering and high-power impulse magnetron sputtering. These findings highlight the pivotal influence of fabrication techniques on the coherence and performance of Nb-based quantum devices, which are vital for applications in superconducting qubits and high-energy superconducting radio-frequency applications.

43 PARTICLE ACCELERATORS↗

Refrigerant charge management in a heat pump water heater

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

42 ENGINEERING↗

Two-zone stratified wetwell model development and implementation for RELAP-7

The Reactor Core Isolation Cooling (RCIC) system consists of a turbine, pump and wetwell and is used in many US Boiling Water Reactors (BWRs) as an important heat removal system. The wetwell is a major heat sink within containment. Experimental investigations have shown that thermal stratification may occur in the wetwell during RCIC operation. Current systems-level analysis codes lack stratified wetwell models. Here, this paper describes the development of a stratified wetwell model for the RELAP-7 code. This paper uses a simple two-zone model for the wetwell water that can capture thermal stratification. This model assumes that a buoyant plume transports heat and mass from the steam injection site to the upper water zone. The buoyant plume assumption requires that steam is injected at a low enough rate so it adds negligible momentum. Model validation against experimental data shows similar trends of temperature field development in the suppression pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Filamentation of dispersive Alfven waves in density channels: Hall magnetohydrodynamics description

Filamentation of dispersive Alfven waves initiated by low or high density channels (depending on the plasma beta) is simulated numerically in the framework of ideal Hall magnetohydrodynamics, and asymptotically modeled with a two-dimensional nonlinear Schroedinger equation including a linear attracting potential. Compared with the dynamics in a homogeneous plasma, the phenomenon is accelerated and occurs for a broader range of parameters. In the case of an isolated channel with a width comparable to the pump wavelength, the transverse wave collapse can be replaced by a moderate amplification. In many cases, a relatively complex dynamics takes place, characterized by an oscillation between magnetic filaments and magnetic ribbons, leading to the formation of small scales at which dissipative effects could become relevant. Alfven vortices, governed by the equations of the reduced magnetohydrodynamics, are also identified in the simulations, in spite of their small amplitude relative to the wave. The formation of structures under the effect of periodic or random distributions of low and high density channels is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗