Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-17: Comparison of Two Novel Algorithms for the Modulation Transfer Function of CT Using a Simple Cylindrical Phantom

Purpose: To compare and analyze two novel algorithms for the assessment of modulation transfer functions (MTFs) of computed tomography (CT) systems using a simple acrylic cylindrical phantom Method and Materials: Images of the acrylic cylindrical phantom were acquired by a GE LightSpeed 16 RT (GE Healthcare, Milwaukee, WI) using 120 kVp, 330 mA, 2.5 mm slice thickness, 10 cm field-of view (FOV), four reconstruction kernels (e.g. standard, soft, detail, bone, and lung). Two different algorithms were used to analyze images for MTF assessment. First, Richard et al. suggested a task-based MTF assessment method through an edge spread function (ESF) which described pixel intensities as a function of distance from the center. The MTF was obtained as the absolute value of Fourier transform of the differentiated ESF. Second, Ohkubo et al. devised an effective method to determine the point spread function (PSF) of CT system accompanied with verification. The line spread function (LSF), which was the one-dimensional integration of the PSF, was used to obtain the MTF. We validated the reliability of two above-mentioned methods through the comparison with a conventional method using a thin tungsten wire phantom. Results: The measured MTFs by two methods were mostly similar each other for standard, soft, and detail kernels. In 0.6 lp/mm, the MTF difference between two methods were 0.012(standard), 0.004(soft), and 0.037(detail). They also coincided with the MTF by the conventional method well. However, there were considerable distinctions for bone and lung kernels containing edge enhancement that might cause undershoots near the peak of the LSF. Conclusions: We compared two novel methods to assess task-based MTFs for clinical CT systems especially using a simple acrylic cylindrical phantom with high-convenience and low-cost, and validated them against a conventional method. This work can provide a practical solution to users for the quality assurance of CT.

60 APPLIED LIFE SCIENCES↗

SU-D-207B-07: Development of a CT-Radiomics Based Early Response Prediction Model During Delivery of Chemoradiation Therapy for Pancreatic Cancer

Purpose: Pilot study developing a CT-texture based model for early assessment of treatment response during the delivery of chemoradiation therapy (CRT) for pancreatic cancer. Methods: Daily CT data acquired for 24 pancreatic head cancer patients using CT-on-rails, during the routine CT-guided CRT delivery with a radiation dose of 50.4 Gy in 28 fractions, were analyzed. The pancreas head was contoured on each daily CT. Texture analysis was performed within the pancreas head contour using a research tool (IBEX). Over 1300 texture metrics including: grey level co-occurrence, run-length, histogram, neighborhood intensity difference, and geometrical shape features were calculated for each daily CT. Metric-trend information was established by finding the best fit of either a linear, quadratic, or exponential function for each metric value verses accumulated dose. Thus all the daily CT texture information was consolidated into a best-fit trend type for a given patient and texture metric. Linear correlation was performed between the patient histological response vector (good, medium, poor) and all combinations of 23 patient subgroups (statistical jackknife) determining which metrics were most correlated to response and repeatedly reliable across most patients. Control correlations against CT scanner, reconstruction kernel, and gated/nongated CT images were also calculated. Euclidean distance measure was used to group/sort patient vectors based on the data of these trend-response metrics. Results: We found four specific trend-metrics (Gray Level Coocurence Matrix311-1InverseDiffMomentNorm, Gray Level Coocurence Matrix311-1InverseDiffNorm, Gray Level Coocurence Matrix311-1 Homogeneity2, and Intensity Direct Local StdMean) that were highly correlated with patient response and repeatedly reliable. Our four trend-metric model successfully ordered our pilot response dataset (p=0.00070). We found no significant correlation to our control parameters: gating (p=0.7717), scanner (p=0.9741), and kernel (p=0.8586). Conclusion: We have successfully created a CT-texture based early treatment response prediction model using the CTs acquired during the delivery of chemoradiation therapy for pancreatic cancer. Future testing is required to validate the model with more patient data.

60 APPLIED LIFE SCIENCES↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the discretization error of the discrete generalized quantum master equation

The transfer tensor method (TTM) [Cerrillo and Cao, Phys. Rev. Lett. 112 , 110401 (2014)] can be considered a discrete-time formulation of the Nakajima–Zwanzig quantum master equation (NZ-QME) for modeling non-Markovian quantum dynamics. A recent paper [Makri, J. Chem. Theory Comput. 21 , 5037 (2025)] raised concerns regarding the consistency of the TTM discretization, particularly a spurious term at the initial time t = 0. Here, this work presents a detailed analysis of the discretization structure of the TTM, clarifying the origin of the initial-time correction and establishing a consistent relationship between the TTM discrete-time memory kernel K N and the continuous-time NZ-QME kernel $\mathscr{K}$( N Δ t ). This relationship is validated numerically using the spin-boson model, demonstrating convergence of reconstructed memory kernels and accurate dynamical evolution as Δ t → 0. While the TTM provides a consistent discretization, we note that alternative schemes are also viable, such as the midpoint derivative/midpoint integral scheme proposed in Makri’s work. The relative performance of various schemes for either computing accurate $\mathscr{K}$( N Δ t ) from exact dynamics or obtaining accurate dynamics from exact $\mathscr{K}$( N Δ t ) warrants further investigation.

Density-matrix↗

3D and 4D magnetic susceptibility tomography based on complex MR images

Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

47 OTHER INSTRUMENTATION↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

InversionNet3D: Efficient and Scalable Learning for 3-D Full-Waveform Inversion

Seismic full-waveform inversion (FWI) techniques aim to find a high-resolution subsurface geophysical model provided with waveform data. Some recent effort in data-driven FWI has shown some encouraging results in obtaining 2-D velocity maps. However, due to high computational complexity and large memory consumption, the reconstruction of 3-D high-resolution velocity maps via deep networks is still a great challenge. Here, in this article, we present InversionNet3D (InvNet3D), an efficient and scalable encoder–decoder network for 3-D FWI. The proposed method employs group convolution in the encoder to establish an effective hierarchy for learning information from multiple sources while cutting down unnecessary parameters and operations at the same time. The introduction of invertible layers further reduces the memory consumption of intermediate features during training and, thus, enables the development of deeper networks with more layers and higher capacity as required by different application scenarios. Experiments on the 3-D Kimberlina dataset demonstrate that InvNet3D achieves state-of-the-art reconstruction performance with lower computational cost and lower memory footprint compared to the baseline.

58 GEOSCIENCES↗

Informative Path Planning for Mapping Radiation

This project involves making measurements of contaminated areas using portable radiation detectors and small robots. Tasks involve operating detectors and small robots, combining data acquisition for the two systems, and automating the systems. The end result is a radiation map of contamination areas. Localization of radioactive sources and mapping of contamination distribution is essential when responding to emergencies, or when dealing with cleanup efforts. Radiation maps are used for situational awareness and for establishing a safe perimeter. However, it may be hazardous or impossible for humans to safely enter the site and survey the area. Informative Path Planning (IPP) is used to design a path for a robotic sensor platform to gather the most information about the radiation distribution while operating under the set of constraints given by the dynamics of the robot and other requirements such as minimizing the overall mission time. The key challenge for IPP is the tight coupling in multiple layers of decisions: Selection of locations to visit; Allocation of sensors to those locations; Processing of information gathered. Given a robot equipped with a basic gamma detector and Lidar sensor, how can we efficiently explore an unknown environment in such a way that we can satisfy the robot's constraints while simultaneously maximizing the accuracy of the map and minimizing the total runtime? This work presents a systematic procedure for IPP and environmental mapping that: Selects the best locations at which to sample; Finds the best path for robots; Estimates the measurement value at unknown locations using a Gaussian Process regression framework. Given a set of points where radiation measurements were taken, we are utilizing a Gaussian Process Regression with a Matern kernel to reconstruct the shape of the underlying ground truth. Mapping is done via the Robot Operating System's OpenSlam Gmapping package, which creates a 2D occupancy grid map. Simulated trials were run with a radiation source placed at random locations, and allowing the robot to select and move towards 20 samples at separate locations, as well as sampling along the path while moving. The simulated sensor model assumed an efficiency of 0.3, collection time of 1 second. Various weighting schemes were tested and compared. Quantitative evaluations often favored exploitation-heavy weighting schemes where μ was emphasized, with the Root Mean Squared Error (RMSE) quickly tending towards 2, whereas qualitative comparisons would favor exploration-biased schemes with greater weight on σ. The difference comes from operators often favoring knowing the general location of a source, rather than the exact properties of a source. Weighting of the path-length π often reduced the quality of the regression as less exploration occurred, however this may be deemed a worthwhile trade-off under certain circumstances, such as with sensitive robots. Successfully developed a methodology for informative path-planning for a robot to efficiently gather information and create a map of radiation. In the future, we would like to focus on: Hardware trials with integration of the robot platform and the IPP software; More refined sensor and environmental modeling; Multiple robot platforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing the adiabatic exchange-correlation kernel of time-dependent density-functional theory

The interacting and the Kohn-Sham static density-density response functions for different one-dimensional two-electron singlet systems are reconstructed numerically. From their inverse we obtain the exact static exchange-correlation kernel. This quantity represents the adiabatically exact approximation of the frequency-dependent exchange-correlation kernel that is crucial for time-dependent linear density-response theory. We investigate its performance for nonlocal perturbations and analyze its sum rule properties. We also compute the adiabatically exact transition energies that follow from the static kernel within linear-response theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining the memory kernel from a fixed point measurement data for a parabolic equation with memory effect

We consider an inverse problem for a parabolic equation with memory effect. This inverse problem aims to identify the memory kernel function from a fixed point measurement data. Based on the fixed point arguments, we derive the global in time existence and uniqueness of our inverse problem. Moreover, we present a numerical algorithm to reconstruct the memory kernel function. Numerical simulations show the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

SU-F-J-75: Accuracy and Stability of Electron Density Measurements Across Patient Size Using Dual Energy CT

Purpose: Dual energy (DE) CT can be used to characterize tissue composition. One application of DE CT is to measure electron density (ED, rho) and atomic number (Z) for use in radiation therapy treatment planning. This work evaluated the accuracy and stability of ED estimation as patient size varied for both single-energy (SE) and DE CT. Methods: An ED phantom (CIRS) and four torso-shaped water tanks (lateral widths 15, 25, 35 and 45 cm) containing 8 tissue-simulating cylinders of known ED were scanned on a dual-source CT system (Siemens Somatom Force) in SE (120 kV) and DE (90/150Sn) modes. Additional scans were performed on the 15 and 25 cm water tanks using DE techniques of 70/150Sn and 80/150Sn, respectively. CTDIvol was matched for all SE and DE scans for a given phantom size. Images were reconstructed using quantitative kernels to preserve CT number accuracy. ED was estimated in each test cylinder and in solid and liquid water using calibration measurements acquired in the CIRS phantom (SE) and a Rho-Z algorithm (DE). Results: ED estimates showed good agreement with the nominal ED values when using Rho-Z (slope = 1.0051, R2 = 0.9982). Mean percent error was similar between SE (1.21%) and DE (1.28%). Mean deviation across patient size decreased 34% (1.43% with SE, 0.95% with DE). When compared to 90/150Sn, DE techniques of 70/150Sn and 80/150Sn showed mean differences in ED of 0.43% and 0.15%, respectively. Conclusion: While both DE Rho-Z and SE CT number calibration methods are both accurate for estimating ED, Rho-Z offers the advantages of having less variability across patient size, not requiring a phantom calibration, and being able to distinguish between materials of similar attenuation, but different chemical composition. Low kV DE pairs are an option in small patients due to lack of effect on ED accuracy. This research was supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Microstructural and Micro-Chemical Evolutions in the Irradiated UCO Fuel Kernels of AGR-1 and AGR-2 TRISO Fuel Particles

AGR-1 and AGR-2 TRISO fuel particles were fabricated with slightly different fuel kernel chemical compositions, modified fabrication processes, different fuel kernel diameters, and changed 235U enrichments. To correlate those differences with the fuel kernel responses to neutron irradiations in terms of irradiated fuel microstructure, fission products chemical and physical states, and fission gas bubble evolutions, extensive microstructural and analytical characterizations were conducted. The studies used a state of art transmission electron microscopy (TEM) equipped with Energy-dispersive X-ray spectroscopy (EDS) of four silicon solid-state detectors which have super sensitivity and fast speed. The TEM specimens were prepared from selected AGR-1 and AGR-2 irradiated fuel kernels exposed to safety testing after irradiation. The particles were chosen to represent a representative irradiation conditions with a fuel burnup within the range from 10.8 to 18.6% FIMA, and the time-average volume-average temperatures vary from 1070 to 1287°C. The 235U enrichment was 19.74 wt.% for the AGR1 fuel kernels and 14.03 wt.% for the AGR-2 fuel kernels. The TEM results show that there were significant microstructural reconstructions in the irradiated fuel kernels for both the AGR-1 and AGR-2 fuels. There are four major phases including fuel matrix of UO2 and UC, U2RuC2, and UMoC2 in the irradiated AGR2 fuel kernel. Zr and Nb form solid solution in the UC phase. UMoC2 phase often shows a detectable concentration of Tc. Pd was found to mainly locate in the buffer layer or to be associated with fission gas bubble within the UMoC2 phase. The EDS maps qualitatively show that the rare-earth fission products (Nb, et al.) preferentially reside in the UO2 phase. In contrast, in the irradiated AGR1 fuel kernel, no U2RuC2 or UMoC2 precipitates were positively identified. Instead, there is a high number of rod-shape precipitates enriched with Ru, Tc, Rh, and Pd observed in the fuel kernel center and edge zone. The difference of microstructural and micro-chemical evolutions in irradiated fuel kernels between the AGR-1 and AGR-2 TRISO fuel particle may result from a combined factor of irradiation temperature, fuel geometry and chemical composition. However, the irradiation temperature probably play a more deterministic role. Limited electron energy loss spectroscopy (EELS) characterizations on the AGR2 fuel kernel show that there is nearly no carbon in the UO2 phase while a small fraction of oxygen was detected in the UC/UMoC2 phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗