Search NASA⌕ Search

SEARCH · Search NASA

Results for “kinetic inductance detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic Inductance Phonon-Mediated Detectors for Dark Matter: R&D at NEXUS

Superconducting thin films have long been used as phonon sensors, particularly in the field of dark matter (DM) direct detection, due to the meV-scale Cooper-pair binding energy. A novel class of these detectors based on microwave kinetic inductance detectors, dubbed Kinetic Inductance Phonon-Mediated Detectors (KIPMDs), offers an attractive architecture for microcalorimeters to probe DM down to the fermionic thermal relic mass limit of a few keV. Such a device featuring an aluminum resonator patterned onto a silicon substrate was operated at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. With this device we have demonstrated a resolution on the energy absorbed by the superconductor of 2.5 eV, a factor of two better than current state-of-the-art. In this talk, I will present our measurement of the energy resolution and phonon collection efficiency performed by exposing the bare substrate to a pulsed source of 470 nm photons. I will also discuss the path forward to obtaining in these devices the sub-eV resolution required to test the “Freeze-in” class of DM models. Finally, I will review other complementary efforts in our group to develop a superconducting qubit-based low-threshold detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MKID Structures for Sub-millimeter Astronomy

Of the high performance detector technologies currently being developed, Microwave Kinetic Inductance Detectors (MKIDs) have the greatest promise for scaling to very large arrays (approx.10(exp 5) detectors). Such arrays can provide high quantum efficiency, and can be designed to provide background limited performance over a wide range of incident powers, making them candidates for a wide range of instruments, ranging from suborbital imagers to spaceborne spectrometers. We are extending Microwave Kinetic Inductance Detectors (MKIDs) technology to the 40 - 400 microns spectral regions via a novel detector concept. In this approach thin film superconducting microstrip lines are used to simultaneously absorb and readout the incident signal with high inter-pixel isolation. Progress on these fabrication and test efforts will be presented.

Wollack, Edward↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

Noise Optimization for MKIDs with Different Design Geometries and Material Selections

The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.

generation-recombination noise↗

Germanium Lift-Off Masks for Thin Metal Film Patterning

A technique has been developed for patterning thin metallic films that are, in turn, used to fabricate microelectronics circuitry and thin-film sensors. The technique uses germanium thin films as lift-off masks. This requires development of a technique to strip or undercut the germanium chemically without affecting the deposited metal. Unlike in the case of conventional polymeric lift-off masks, the substrate can be exposed to very high temperatures during processing (sputter deposition). The reason why polymeric liftoff masks cannot be exposed to very high temperatures (greater than 100 C) is because (a) they can become cross linked, making lift-off very difficult if not impossible, and (b) they can outgas nitrogen and oxygen, which then can react with the metal being deposited. Consequently, this innovation is expected to find use in the fabrication of transition edge sensors and microwave kinetic inductance detectors, which use thin superconducting films deposited at high temperature as their sensing elements. Transition edge sensors, microwave kinetic inductance detectors, and their circuitry are comprised of superconducting thin films, for example Nb and TiN. Reactive ion etching can be used to pattern these films; however, reactive ion etching also damages the underlying substrate, which is unwanted in many instances. Polymeric lift-off techniques permit thin-film patterning without any substrate damage, but they are difficult to remove and the polymer can outgas during thin-film deposition. The outgassed material can then react with the film with the consequence of altered and non-reproducible materials properties, which, in turn, is deleterious for sensors and their circuitry. The purpose of this innovation was to fabricate a germanium lift-off mask to be used for patterning thin metal films.

Brown, Ari↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

The KIPM Detector Consortium

Kinetic Inductance Phonon-Mediated (KIPM) Detectors, microcalorimeters that leverage kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate, are an attractive architecture for low-threshold rare-event searches due to their large response to small changes in quasiparticle density and native multiplexability, enabling scalability. We have established a consortium comprising university and national lab groups dedicated to advancing the state-of-the-art in these detectors, with the ultimate goal of designing a detector with a kg-scale target mass and sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasiparticle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a sensor resolution (i.e., resolution in the quasiparticle channel) of 2.1 eV, the current record for such devices. The current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-Tc superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors. In this talk, I will provide an overview of the consortium and its capabilities, highlight some recent results from its member groups, and discuss near term plans toward reaching the ultimate goal.

Temples, Dylan J. [Fermilab]↗

Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer

Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗