Search NASA⌕ Search

SEARCH · Search NASA

Results for “kinetic inductance detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer

Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films

We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.

Superconducting↗

An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

semi-empirical model↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Low-Loss Thin-Film Al-On-Si Microwave Resonators for Astronomy Applications Designing and Characterizing the Next Generation of Microwave Detectors

We present measurements of prototype thin film Al microwave kinetic inductance detectors (MKIDs) intended for application in the sub-mm astronomy balloon experiment EXCLAIM. The device we show is dark, or non-optically coupled, and contains 16 coplanar waveguide (CPW) resonators etched into a 261 nm sputter deposited Al layer on a Si wafer. The resonators span the f0 = 3.5 - 4 GHz range, and include both lambda=2 and lambda=4 resonators. Each resonator is coupled to the feedline using one of three alternating coupling designs. We performed transmission line measurements of the device for a series of excitation powers ranging from -90 dBm to -30 dBm, and at a series of base temperatures ranging from 73 mK to 400 mK. We observed quality factors of up to Qi  107 at a base temperature of 73 mK. The lambda=2 and lambda=4 resonators performed similarly, achieving comparable Qi values. The results of these measurements are actively informing the fi nal design of the EXCLAIM instrument. EXCLAIM will incorporate six spectrometers, each containing an array of over 300 resonators in the 420-540 GHz range.

Carrie Volpert↗

Fabrication of Compact Superconducting Lowpass Filters for Ultrasensitive Detectors

It is extremely important for current and future far-infrared and sub-millimeter ultrasensitive detectors, which include transition edge sensors (TES) and microwave kinetic inductance detectors, to be adequately filtered from stray electromagnetic radiation in order to achieve their optimal performance. One means of filtering stray radiation is to block leakage associated with electrical connections in the detector environment. Here we discuss a fabrication methodology for realizing non-dissipative planar filters imbedded in the wall of the detector enclosure to limit wave propagation modes up to far-infrared frequencies. Our methodology consists of fabricating a boxed stripline transmission line, in which a superconducting (Nb, Mo, or Al) transmission line is encased in a silicon dioxide dielectric insulator coated with a metallic shell. We report on achieved attenuation and return loss and find that it replicates the simulated data to a high degree.

Brown, Ari↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and far-infrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5 micrometer thick silicon membrane, and 380 micrometer thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

Brown, Ari-David↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and farinfrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5μm thick silicon membrane, and 380μm thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

far-infrared↗

Superconducting Films for Absorber-coupled MKID Detectors for Sub-millimeter and Far-infrared Astronomy

We describe measurements of the properties, at dc, gigahertz, and terahertz frequencies, of thin superconducting films with relatively high normal state sheet resistance. Such films can be applied to construct microwave kinetic inductance detector sensor arrays for submillimeter and far-infrared astronomical applications in which the incident power excites quasiparticles directly in a superconducting resonator that is configured to present a matched-impedance to the high frequency radiation being detected. For several materials, and a range of thicknesses down to 10 nm, we present measurements of normal state sheet resistance, resistance-temperature curves for the superconducting transition, quality factor and kinetic inductance fraction for microwave resonators made from patterned films, and terahertz measurements of the sheet impedance measured with a Fourier Transform Spectrometer.

Stevenson, T. R.↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a high-altitude balloon telescope designed to deepen our understanding of star formation in a cosmological context, shedding light on why the star formation rate declines and breaks away from the cosmological evolution of dark matter for redshifts z>2 [1]. EXCLAIM will operate at 420–540 GHz with a spectral resolution of R=512 to measure the integrated line emission from galaxies and the intergalactic medium (IGM), in particular CO and [CII] line emissions from the nearby universe out to redshifts of z~3.5. This approach is known as Intensity Mapping (IM), which provides efficient access to large cosmological volumes and redshifts with sensitivity limited by detector noise or photon background, while requiring modest apertures. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) with superconducting microwave kinetic inductance detectors (KIDs) in an all-cryogenic telescope (1.7 K) to achieve near background-limited sensitivity. Here, we present an overview of the EXCLAIM instrument and status, with emphasis on the Attitude Determination & Control System (ADCS) and the thermal system.

Giuseppe Cataldo↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

Recent Results of a New Microwave SQUID Multiplexer

We are developing a proof-of-concept microwave SQUID multiplexer containing four SQUIDs coupled to GHz frequency resonant circuits and fed with a single microwave readout line. The resonators are half-wave coplanar waveguide sections and are similar to the structures used for the microwave kinetic inductance detectors developed in our group. Optimal values for the interdigital gap capacitors were determined to maximize the sensitivity of the transmitted and reflected microwave signal with respect to changes in the dynamic resistance of the SQUID. The dc current-bias line for the SQUID has an in-line inductive high frequency filter to minimize coupling between the bias line and resonator. A high frequency modulation scheme is proposed to eliminate the need for individual flux biasing of the SQUIDs, which extends the dynamic range of the readout. In this scheme a common modulation signal is imposed on each SQUID and the received signal is demodulated at one and two times the modulation frequency to maintain sensitivity at any flux state. We present the recent results of the microwave SQUID multiplexer system operating at a readout frequency range of 10 - 11GHz.

superconducting quantum interference device (SQUID↗

Mu-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the Mu-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Micro-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the micro-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the micro strip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

NASA Tech Briefs, December 2013

Topics include: Microwave Kinetic Inductance Detector With; Selective Polarization Coupling; Flexible Microstrip Circuits for; Superconducting Electronics; CFD Extraction Tool for TecPlot From DPLR Solutions; RECOVIR Software for Identifying Viruses; Enhanced Contact Graph Routing (ECGR) MACHETE Simulation Model; Orbital Debris Engineering Model (ORDEM) v.3; Scatter-Reducing Sounding Filtration Using a Genetic Algorithm and Mean Monthly Standard Deviation; Thermo-Mechanical Methodology for Stabilizing Shape Memory Alloy Response; Hermetic Seal Designs for Sample Return Sample Tubes; Silicon Alignment Pins: An Easy Way To Realize a Wafer-to-Wafer Alignment; Positive-Buoyancy Rover for Under Ice Mobility; Electric Machine With Boosted Inductance to Stabilize Current Control; International Space Station-Based Electromagnetic Launcher for Space Science Payloads; Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems; Data Quality Screening Service.

Source record↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗