Search NASA⌕ Search

SEARCH · Search NASA

Results for “kits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mass and Volume Optimization of Space Flight Medical Kits

Resource allocation is a critical aspect of space mission planning. All resources, including medical resources, are subject to a number of mission constraints such a maximum mass and volume. However, unlike many resources, there is often limited understanding in how to optimize medical resources for a mission. The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulates outcomes and describes the impact of medical events in terms of lost crew time, medical resource usage, and the potential for medically required evacuation. Previously published work describes an approach that uses the IMM to generate optimized medical kits that maximize benefit to the crew subject to mass and volume constraints. We improve upon the results obtained previously and extend our approach to minimize mass and volume while meeting some benefit threshold. METHODS We frame the medical kit optimization problem as a modified knapsack problem and implement an algorithm utilizing dynamic programming. Using this algorithm, optimized medical kits were generated for 3 mission scenarios with the goal of minimizing the medical kit mass and volume for a specified likelihood of evacuation or Crew Health Index (CHI) threshold. The algorithm was expanded to generate medical kits that maximize likelihood of evacuation or CHI subject to mass and volume constraints. RESULTS AND CONCLUSIONS In maximizing benefit to crew health subject to certain constraints, our algorithm generates medical kits that more closely resemble the unlimited-resource scenario than previous approaches which leverage medical risk information generated by the IMM. Our work here demonstrates that this algorithm provides an efficient and effective means to objectively allocate medical resources for spaceflight missions and provides an effective means of addressing tradeoffs in medical resource allocations and crew mission success parameters.

Monte Carlo Method↗

Studies on KIT-6 Supported Cobalt Catalyst for Fischer–Tropsch Synthesis

KIT-6 molecular sieve was used as a support to prepare cobalt catalyst for Fischer-Tropsch synthesis (FTS) using an incipient wetness impregnation method to produce cobalt loadings of 15 and 25 wt%. The catalysts were characterized by BET surface area, X-ray diffraction, scanning transmission election microscopy (STEM), extended X-ray absorption fine spectroscopy and X-ray absorption near edge spectroscopy. The catalytic properties for FTS were evaluated using a 1L CSTR reactor. XRD, pore size distribution, and STEM analysis indicate that the KIT-6 mesostructure remains stable during and after cobalt impregnation and tends to form smaller cobalt particles, probably located inside the mesopores. The mesoporous KIT-6 exhibited a slightly higher cobalt dispersion compared to amorphous SiO{sub 2} supported catalyst. With the higher Co loading (25 wt%) on KIT-6, partial structural collapse was observed after the FTS reaction. Compared to an amorphous SiO{sub 2} supported cobalt catalyst, KIT-6 supported cobalt catalyst displayed higher methane selectivity at a similar Co loading, likely due to diffusion effects.

01 COAL, LIGNITE, AND PEAT↗

Discovery of amido-benzisoxazoles as potent c-Kit inhibitors

Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.

59 BASIC BIOLOGICAL SCIENCES↗

Scat Detection Dog Surveys for the San Joaquin Kit Fox on the Lawrence Livermore National Laboratory's Experimental Test Site (Site 300) and the Corral Hollow Ecological Reserve, Alameda and San Joaquin Counties, California

The San Joaquin kit fox (Vulpes macrotis mutica) historically occupied a large range in the San Joaquin Valley, California; however, their populations and habitat have since been significantly reduced by human impacts. More than 95% of the potential habitat for kit foxes on the San Joaquin Valley floor has been converted to irrigated agriculture, urbanized, or industrialized. The San Joaquin kit fox was listed as endangered by the USFWS in 1967 and as threatened by the State of California in 1971. In 2018, Working Dogs for Conservation (WD4C) was contracted by LLNS to provide professional conservation detection dog teams to survey for scats of San Joaquin kit fox on Site 300 and the neighboring California Department of Fish and Wildlife's Corral Hollow Ecological Reserve. The purpose of the surveys was to obtain updated information on kit fox presence on these properties.

54 ENVIRONMENTAL SCIENCES↗

Scat Detection Dog Surveys for the San Joaquin Kit Fox on the Lawrence Livermore National Laboratory's Experimental Test Site (Site 300) and the Corral Hollow Ecological Reserve: 2020 Deployment

The San Joaquin kit fox (Vulpes macrotis mutica) historically occupied an extensive range in the San Joaquin Valley, California; however, their populations and habitat have since been significantly reduced by human impacts (United States Fish and Wildlife Service [USFWS] 1998). More than 95% of the potential habitat for kit foxes on the San Joaquin Valley floor has been converted to irrigated agriculture, urbanized, or industrialized lands. The San Joaquin kit fox was listed as endangered by the USFWS in 1967 and as threatened by the State of California in 1971. Records from local surveys, research projects, and incidental sightings indicate the present distribution of kit foxes extends from 1) southern Kern County north to Contra Costa, Alameda, and San Joaquin counties on the west side of the valley and to Stanislaus County on the east side; 2) into some of the larger, uncultivated valley-floor land parcels in Kern, Tulare, Kings, Fresno, Madera, and Merced counties; and 3) westward within 5 counties in the interior coastal range (USFWS 1998). Kit foxes have been denoted to occur in 3 geographically distinct core and several satellite populations in a heavily fragmented landscape, with the largest extant populations concentrated in the southern part of the range and smaller populations and isolated sightings in the central and northern portions (USFWS 1998, 2010).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Three RNA Extraction Kits with a 2019-nCoV Assay

The following characteristics of three RNA extraction kits (Norgen Biotek Total RNA Purification Kit, #17200; Bioneer AccuPrep Viral RNA Extraction Kit, #K-3033; and Promega Maxwell HT Viral TNA Kit, #AX2340) were evaluated: Limits of detection for quantitative synthetic RNA using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Limits of detection for positive clinical specimen using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Ability of the lysis buffers in each kit to inactivate the virus as measured by a cell-based infectivity assay.

60 APPLIED LIFE SCIENCES↗

Development of Experiment Kits for Processing Biological Samples In-Flight on SLS-2

The design of the hematology experiment kits for SLS-2 has resulted in a modular, flexible configuration which maximizes crew efficiency and minimizes error and confusion when dealing with over 1200 different components over the course of the mission. The kit layouts proved to be very easy to use and their packaging design provided for positive, secure containment of the many small components. The secondary Zero(Tm) box enclosure also provided an effective means for transport of the kits within the Spacelab and for grouping individual kits by flight day usage. The kits are readily adaptable to use on future flights by simply replacing the inner components as required and changing the labelling scheme to match new mission requirements.

Jaquez, R.↗

Evaluating the Medical Kit System for the International Space Station(ISS) - A Paradigm Revisited

Medical capabilities aboard the International Space Station (ISS) have been packaged to help astronaut crew medical officers (CMO) mitigate both urgent and non-urgent medical issues during their 6-month expeditions. Two ISS crewmembers are designated as CMOs for each 3-crewmember mission and are typically not physicians. In addition, the ISS may have communication gaps of up to 45 minutes during each orbit, necessitating medical equipment that can be reliably operated autonomously during flight. The retirement of the space shuttle combined with ten years of manned ISS expeditions led the Space Medicine Division at the NASA Johnson Space Center to reassess the current ISS Medical Kit System. This reassessment led to the system being streamlined to meet future logistical considerations with current Russian space vehicles and future NASA/commercial space vehicle systems. Methods The JSC Space Medicine Division coordinated the development of requirements, fabrication of prototypes, and conducted usability testing for the new ISS Medical Kit System in concert with implementing updated versions of the ISS Medical Check List and associated in-flight software applications. The teams constructed a medical kit system with the flexibility for use on the ISS, and resupply on the Russian Progress space vehicle and future NASA/commercial space vehicles. Results Prototype systems were developed, reviewed, and tested for implementation. Completion of Preliminary and Critical Design Reviews resulted in a streamlined ISS Medical Kit System that is being used for training by ISS crews starting with Expedition 27 (June 2011). Conclusions The team will present the process for designing, developing, , implementing, and training with this new ISS Medical Kit System.

Hailey, Melinda J.↗

CG-Kit: Code Generation Toolkit for performant and maintainable variants of source code applied to Flash-X hydrodynamics simulations

CG-Kit is a new Code Generation tool-Kit that we have developed as a part of the solution for portability and maintainability for multiphysics computing applications. The development of CG-Kit is rooted in the urgent need created by the shifting landscape of high-performance computing platforms and the algorithmic complexities of a particular large-scale multiphysics application: Flash-X. To efficiently use computing resources on a heterogeneous node, an application must have a map of computation to resources and a mechanism to move the data and computation to the resources according to the map. Most existing performance portability solutions are focussed on abstracting the expression of computations so that a unified source code can be specialized to run on different resources. However, such an approach is insufficient for a code like Flash-X, which has a multitude of code components that can be assembled in various permutations and combinations to form different instances of applications. Similar challenges apply to any code that has composability, where a single specified way of apportioning work among devices may not be optimal. Additionally, use cases arise where the optimal control flow of computation may differ for different devices while the underlying numerics remain identical. This combination leads to unique challenges including handling an existing large code base in Fortran and/or C/C++, subdivision of code into a great variety of units supporting a wide range of physics and numerical methods, different parallelization techniques for distributed and shared memory systems and accelerator devices, and heterogeneity of computing platforms requiring coexisting variants of parallel algorithms. All of these challenges demand that scientific software developers apply existing knowledge about domain applications, algorithms, and computing platforms to determine custom abstractions and granularity for code generation. There is a critical lack of tools to tackle those problems. CG-Kit is designed to fill this gap by providing a user with the ability to express their desired control flow and computation-to-resource map in the form a pseudocode-like recipe. It consists of standalone tools that can be combined into highly specific and, we argue, highly effective portability and maintainability toolchains. Here we present the design of our new tools: parametrized source trees, control flow graphs, and recipes. The tools are implemented in Python. They are agnostic to the programming language of the source code targeted for code generation. In conclusion, we demonstrate the capabilities of the toolkit with two examples, first, multithreaded variants of the basic AXPY operation, and second, variants of parallel algorithms within a hydrodynamics solver, called Spark, from Flash-X that operates on block-structured adaptive meshes.

Algorithmic portability↗

Neutron Measurement Instrumentation Development at KIT for the European ITER TBM

Fusion power reactors will rely on the internal production of the fuel tritium from lithium in the tritium breeding blanket. Test Blanket Modules (TBM) will be installed in ITER with the aim to investigate the nuclear performance of different breeding blanket designs. Currently there is no fully qualified nuclear instrumentation available for the measurement of neutron fluxes and tritium production rates which would be able to withstand the harsh environment conditions in the TBM such as high temperature (>400 deg. C) and, depending on the operation scenario, intense radiation levels. As partner of the European Consortium on Nuclear Data and Measurement Techniques in the framework of several F4E specific grants and contracts, KIT and ENEA have jointly studied the possibility to develop and test detectors suitable to operate in ITER-TBMs. Here we present an overview of ongoing work on three types of neutron flux monitors under development for the TBMs with focus on the KIT activities. A neutron activation system (NAS) with pneumatic sample transport could provide absolute neutron flux measurements in selected positions. A test system for investigating activation materials with short half-lives was constructed at the DT neutron generator laboratory of Technical University of Dresden to investigate the neutronics aspects. Several irradiations have been performed with focus on the simultaneous measurement of the extracted activated probes. An engineering assessment of a TBM NAS in the conceptual design phase has been done which considered issues of design requirements and integration. Last but not least, a mechanical test bench is under construction at KIT which will address issues of driving the activation probes, solutions for loading the system etc. experimentally. Self-powered neutron detectors (SPND) are widely applied in fission reactor monitoring, and the commercially available SPNDs are sensitive to thermal neutrons. We are investigating novel materials for SPND which would be sensitive also to the fast neutron flux expected in the TBMs. To this end simulations were done with the European Activation System EASY and neutron flux spectra which were calculated with MCNP for the HCPB TBM. Preliminary tests with commercial SPND in a fast reactor were performed. As a result of these activities, several materials have been found which may be suitable for the measurement of fast neutron fluxes in the TBM. Test detectors are under preparation for testing with DT neutron generators. Within the I{sub S}MART project, funded by KIC InnoEnergy, KIT is developing an online detector based on silicon carbide electronics for the TBMs. The operation of such detectors at TBM relevant temperatures is expected to incur lower accumulated radiation damage to them than at room temperature due to annealing effects. Detectors of several designs have been already irradiated with DT neutrons. Irradiation tests at elevated temperatures have been done and further tests are currently underway. This paper summarizes the status of the work for these three neutron flux monitor systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit

The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPA certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NO X ) emissions exceeded the Tier 2/Bin 5 intermediate life NO X standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NO X standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO X emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.

02 PETROLEUM↗

Low-cost Retrofit Kit for Integral Reciprocating Compressors (IRCs) to Reduce Emissions and Enhance Efficiency

Methane emissions from natural gas engines within the oil and gas industry pose a significant environmental challenge, contributing approximately 34.1 MMTCO2 eq to the total of 239 MMTCO2 eq of methane emissions in 2021, according to the EPA report. In response to this pressing issue, a collaborative effort involving the University of Oklahoma and key industry partners—WAGO Automation, Mid Continental Rental, Elipsa, and Perscient—has resulted in the development of a retrofit kit designed to reduce emissions from integral reciprocating compressors (IRCs), which are integrated compressors and engines. The retrofit kit developed comprises an Air Management System (AMS), Integrated Sensors, and a Cloud-Connected Control Unit with Graphical User Interface (GUI)/Human-Machine Interface (HMI). This solution enhances operational efficiency, reduces emissions, and expands the operational envelope of IRCs in the natural gas industry. The project successfully completed all tasks, including the installation of a full-size IRC at a designated site in Oklahoma, the development of an optimized AMS, integration of sensors, and implementation of a data acquisition system. Significant achievements include a notable reduction in CH 4 emissions, up to 84% at specific loads, and the successful deployment of the retrofit kit in diverse field conditions. The system's capabilities were enhanced through the creation of a feedback control algorithm for the AMS using a correlation matrix illustrating relationships between engine parameters, and the design of a predictive and preventive maintenance platform. The project concluded with the deployment of the entire retrofit kit to another location, confirming its effectiveness in reducing emissions and enhancing IRC performance. The comprehensive solution offers valuable benefits for IRCs, making them invaluable assets in the natural gas industry.

03 NATURAL GAS↗

Final Technical Report of a Feasibility Investigation of a Hydropower Flexibility Upgrade Kit

The project studied the feasibility of a concept for a flexibility upgrade kit called h-Dynamyk to improve the flexibility of U.S. hydropower plants and assessed its potential impact on the U.S. hydropower industry. This concept addresses the growing need for grid flexibility amid rising renewable energy adoption, such as wind and solar, which often introduce intermittency. The upgrade kit is intended to address challenges posed by aging turbine designs in meeting modern grid demands for flexibility services like frequency response, voltage control, spinning reserve, and black-start capabilities. Key features of the h-Dynamyk kit include siphon turbine assemblies, medium-voltage variable frequency drives (VFDs), and smart controls integrated with plant systems to optimize operations and extend equipment life. This nine-month discovery project successfully achieved its objectives by defining a baseline design and performance metrics for the h-Dynamyk flexibility upgrade kit, analyzing this baseline, and incorporating lessons learned from this analysis into a modified set of metrics and recommendations for future design and testing, which were further guided by field site studies.

13 HYDRO ENERGY↗

Creation of learning kits

A learning kit is an essential part of any remote sensing workshop, course, or in-house training program to provide the "hands-on" experience of working with remotely sensed imagery. This is the objective of laboratory and field exercises as well as the reason behind the production of imagery/map kits. The way in which these learning kits (containing conventional remotely sensed and collateral data products) are put together is described and some concerns that influence the creation of learning kits are discussed. These include budgetary constraints, number of imagery types, and number of collateral data types.

Stow, D. A.↗

Experiment kits for processing biological samples inflight on SLS-2

This paper describes development of an innovative, modular approach to packaging the instruments used to obtain and preserve the inflight rodent tissue and blood samples associated with hematology experiments on the Spacelab Life Sciences-2 (SLS-2) mission. The design approach organized the multitude of instruments into twelve 5- x 6- x l-in. kits which were each used for a particular experiment. Each kit contained the syringes, vials, microscope slides, etc., necessary for processing and storing blood and tissue samples for one rat on a particular day. A total of 1245 components, packaged into 128 kits and stowed in 17 Zero(registered trademark) boxes, were required. Crewmembers found the design easy to use and laid out in a logical, simple configuration which minimized chances for error during the complex procedures in flight. This paper also summarizes inflight performance of the kits on SLS-2.

Savage, P. D.↗

Telescience Resource Kit

This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.

Schneider, Michelle↗

Optimization Routine for Generating Medical Kits for Spaceflight Using the Integrated Medical Model

The Integrated Medical Model (IMM) is a MATLAB model that provides probabilistic assessment of the medical risk associated with human spaceflight missions.Different simulations or profiles can be run in which input conditions regarding both mission characteristics and crew characteristics may vary. For each simulation, the IMM records the total medical events that occur and “treats” each event with resources drawn from import scripts. IMM outputs include Total Medical Events (TME), Crew Health Index (CHI), probability of Evacuation (pEVAC), and probability of Loss of Crew Life (pLOCL).The Crew Health Index is determined by the amount of quality time lost (QTL). Previously, an optimization code was implemented in order to efficiently generate medical kits. The kits were optimized to have the greatest benefit possible, given amass and/or volume constraint. A 6-crew, 14-day lunar mission was chosen for the simulation and run through the IMM for 100,000 trials. A built-in MATLAB solver, mixed-integer linear programming, was used for the optimization routine. Kits were generated in 10% increments ranging from 10%-100% of the benefit constraints. Conditions wheremass alone was minimized, volume alone was minimized, and where mass and volume were minimizedjointly were tested.

Medical Kit↗

Data Center Energy Efficiency Measurement Assessment Kit Guide and Specification

A portable and temporary wireless mesh assessment kit can be used to speed up and reduce the costs of a data center energy use assessment and overcome the issues with respect to shutdowns. The assessment kit is comprised of temperature, relative humidity, and pressure sensors. Also included are power meters that can be installed on computer room air conditioners (CRACs) without intrusive interruption of data center operations. The assessment kit produces data required for a detailed energy assessment of the data center.

Data, Center, Energy, Efficiency, Measurement, Ass↗