Search NASA⌕ Search

SEARCH · Search NASA

Results for “large pilot plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fast ion confinement in quasi-axisymmetric stellarator equilibria

This report presents an initial analysis of the fast ion confinement and losses within quasi-axisymmetric stellarator equilibria in consideration by Thea Energy. The equilibria have not yet been explicitly optimized for fast particle confinement and require validation. Modeling with the ASCOT5 code is used to directly examine the fast ion transport. The particle tracking simulations are purely (neo)classical in nature and simply contain the supplied equilibrium and collisions (pitch-angle, energy slowing, and velocity diffusion) from supplied thermal profiles. Uniform marker deposition is used to probe the general confinement properties of the equilibria while a realistic beam-born population is provided from the BEAMS3D code and an alpha particle population is calculated from a fusion source integrator. A first wall is included and defines the loss boundary. Analysis for NBI ions within Thea Energy’s conceptual Eos neutron source are presented along with alpha particles in an enlarged DT-plasma. The fast ions are assessed in regards to their confinement time, pitch, energy, and spatial coordinates. For each population, the impact of collisions and orbit drifts are discussed. It is found that NBI born ions in Eos are strongly confined until slowing-down, owing largely to the tangential injection geometry, while 22% of DT-born alpha energy is lost in the scaled device, indicating that any fusion pilot plant design optimization should include metrics for fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of radiated-power for low aspect ratio fusion plasmas

Investigating radiated power in fusion plasmas is of utmost importance to understand the effect of undesired impurities, such as metals, in present devices, or also desired impurities, such as noble gasses, to purposefully radiate a large fraction of power in future devices. These studies are especially important for high Z impurities which will play a crucial role in future generation fusion pilot plants. In this work, we have developed a power radiation analysis module, which is used to investigate 2D distributions of impurity densities and radiated power asymmetries caused due to both plasma rotation and the cooling rate dependence on temperature profile for the cases of experimental NSTX plasmas and designed scenarios for the spherical tokamak advanced reactor (STAR), both being low aspect ratio tokamaks. Two different atomic databases have been tested during this work to study their impact on the radiated power distribution, especially for high Z impurities. Also in PRAM, self-consistent calculations of two-dimensional electron, main ion, and impurity ion densities are carried out using one-dimensional input density, temperature, and rotation profiles. In the case of NSTX, discharges with high rotation of ∼ 170 km s, measured with charge exchange recombination spectroscopy, have been investigated. Rotation-induced charge separation, leading to an electrostatic potential, is calculated iteratively to a self-consistent solution while testing high Z impurities to observe any 2D asymmetry in the core radiated power due to centrifugal forces. The STAR design, being much larger (R = 4 m), is projected to have a much lower rotation, and is shown to have low rotation-induced asymmetries, on the order of ten percent or less, between the low field and high field sides. However, another effect not due to rotation but to the dependence of impurity cooling rates on temperature can lead to radiation peaking off-axis, near the plasma edge. This effect is noticeable for argon in NSTX, for example, but can also be enhanced for certain impurities at much higher temperatures projected for STAR (T e0 ~ 32 keV), for example for undesired tungsten or possibly desired xenon.

NSTX↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

BETO 2021 Peer Review - 3.4.2.302 - Process Scale Up for Production Environments

This project supports the Department of Energy's Bioenergy Technology Office mission of transitioning bioenergy technologies to market by de-risking integration, developing scaling relations and modeling that de-risks scale up, and providing a feedback loop with lower TRL projects to understand process and technology fundamentals. Two objectives were pursued during this merit cycle. First, the Thermal and Catalytic Process Development Unit (TCPDU), a 0.5 ton/day pilot plant, was used to validate kinetic models developed by the Consortium for Computational Physics and Chemistry (CCPC). Validating the models accurately predict product yields and composition is a first step toward de-risking a common industry failure - taking too large of steps between scales. In addition, these models help with design and troubleshooting of new unit operations for the TCPDU. The second objective was to conduct the FY22 verification campaign around ex situ CFP. The primary challenge of this effort was the coordination of multiple national labs and projects. This was overcome by a dedicated leadership role and effective communication strategy between the projects. Currently the project is undergoing a pivot based on a stagegate decision to not conduct the verification campaign in the TCPDU and it is focused on closing out the CFP technology at a smaller scale by the end of the current fiscal year.

BIOMASS FUELS↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Summary of the Brine Availability Test in Salt (BATS), Including Extended Plan for Experiments at the Waste Isolation Pilot Plant (WIPP)

This document lays out a set of near-future investigations in salt, the third phase of BATS (BATS 3). This phase is planned to answer the few remaining issues from the first two phases of BATS (BATS 1 and BATS 2), and to prepare for a subsequent large-scale demonstration phase. The BATS experiments are the first part of a larger plan to conduct field experiments to answer specific technical questions, improve the technical basis for disposal of heat-generating radioactive waste in salt (Stauffer et al., 2015; SNL et al., 2020), and demonstrate readiness for disposal of radioactive waste in salt, including large, hot waste packages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy use of piperazine with the advanced stripper from pilot plant testing

Here, piperazine with the Advanced Stripper (PZAS™) was tested at the National Carbon Capture Center (NCCC) at coal and NGCC conditions. Energy performance was measured with accounting for heat loss. The net heat duty was found to be identical at 2.45 GJ/tonne for both 4 and 12% CO 2 at 90% CO 2 removal. The average measured heat loss was 0.38 GJ/tonne and represented 30% of the gross heat rate. For PZAS, the warm rich piping before the control valve is the largest in surface area. Heat loss at this location increased heat duty by 80% of the heat loss value. Therefore, the total heat duty was decreased by 80% of the heat loss. The Independence™ model was validated using 112 steady-state pilot plant runs and predicted average net heat duty with an error of 9% and lean loading with an error of 10%. The model was used to simulate process impacts of heat loss for the PZAS and simple stripper configurations. For both strippers, heat loss was found to impact heat duty at locations other than just the steam heater. While heat loss in the steam heater was the most important for PZAS, heat loss in the column was the most important for the simple stripper due to a large top-side pinch and CO 2 reabsorption at the same location. CO 2 reabsorption in PZAS occurred only at high heat loss values (~0.14 GJ/hr), compared to low heat loss values (~ 0.03 GJ/hr) in the PZ-simple stripper. Excessive packing in the PZ-simple stripper caused a large top-side pinch at 0.23 mol/mol lean loading, making the column very sensitive to heat loss. Heat loss in the PZ-simple stripper increased heat duty by 120–150% at typical heat loss values and lean loading of 0.23 mol/mol. Heat loss in the MEA-simple stripper only increased heat duty by 1–13% in a typical lean loading range of 0.1–0.2 mol/mol. A large bottom side pinch at low lean loading for 7 m MEA made the effect of heat loss less pronounced.

42 ENGINEERING↗

The Novel Charfuel® Coal Refining Process 18 TPD Pilot Plant Project for Co- Producing an Upgraded Coal Product, and Commercially Valuable Co- Products: Area of Interest #3 – Coal Beneficiation Pilot Plant Testing (Final Report)

Operation of Carbon Fuels, LLC’s (“CF”) existing, permitted 18 TPD pilot plant located in Golden, Colorado using two individually ranked (ASTM D 388) coal types (two campaigns), employing the novel Charfuel® coal refining process to produce an upgraded coal product and a number of high-valued organic and inorganic coproducts (for which there presently exists large commercial markets) in order to produce engineering and product data which will then be utilized toward the design of a commercial scale integrated facility (pre-feed document). Carbon Fuels, LLC has developed the Charfuel® Coal Refining Process which refines domestically abundant, raw coal (in the same manner as crude oil is refined) to produce the identical, high value co-products that are refined from crude oil. Thus, gasoline, jet fuel, “green diesel”, fuel oil, and marine fuels, as well as petrochemicals such as benzene, toluene, xylene, and methanol are refined from raw coal using this process. The Charfuel® Coal Refining Process is not a coal conversion process, like pyrolysis, or indirect liquefaction. Nor is it an alternative energy system. Rather it is a coal refining process that has the ability to economically produce products traditionally associated with the refining of crude oil but using only abundant, raw coal as the refinery feed stock. The Charfuel® Coal Refining Process is more economical than crude oil refining and is environmentally benign. Therefore, this value added process yields a return on investment well above 50% for a commercial facility. Furthermore, the Charfuel® process, unlike alternatives such as ethanol and hydrogen, can utilize the existing transportation, delivery, and other petroleum based systems. Hence, there is no need for new engines, pipelines, tankers, or product acceptance. As a result, the profitability of the process is increased. Objectives: (1) Operation of the integrated 18 tpd pilot plant, using two coal types (ranks); (2) Demonstration of process flexibility in being able to produce different products (gas, liquid, and char), as well as determination of operating parameters for identifying scale up criteria for two coal types (ranks); (3) Generation of engineering and design information (process specifications) for use in designing a commercial scale plant (scale-up); (4) Determination of important environmental issues surrounding the process and the products such as fate of trace elements (mercury and other heavy metals) and distributions of SO2, NOx, and CO 2 by analysis of effluent streams; (5) Production of sufficient product to allow reliable commercial economic evaluation of both the refined coal product and the coproducts; and, (6) Assessment of longer-term reliability of unit operations. Period 1: reconfiguration of the 18 TPD plant to meet specific FOA requirements and to qualify the facility for operation; and, Period 2: operation of the 18 TPD plant for two campaigns using two coals types (ranks) which are widely commercially used and abundant - the first being a subbituminous (Powder River Basin (“PRB”)) coal, and the second a bituminous (Illinois #6) coal.

01 COAL, LIGNITE, AND PEAT↗

Linear and Nonlinear Solvers for Simulating Multiphase Flow within Large-Scale Engineered Subsurface Systems

Simulation of multiphase flow in the subsurface is well-known to be computationally challenging. While there have been many studies that have explored approaches to overcoming these challenges, they often utilize relatively simple case studies. In this paper, we focus on the unique numerical challenges posed by modeling large-scale engineered subsurface systems, characterized by discrete features embedded in a heterogeneous natural subsurface setting. The man-made features such as shafts, tunnels, and barriers often cause multiple challenges in modeling the domain for multiphase porous media flow. This flow scenario can have a wide range of applications such as nuclear waste repositories, enhanced recovery of a petroleum reservoir, geothermal engineering, and carbon sequestration. An example of these severe numerical challenges is the case of performance assessment (PA) for Waste Isolation Pilot Plant (WIPP), the only operating deep geological repository in the US, which simulates extreme material properties of bedded salt rock formation and extreme contrast due to open excavation next to the formation. The models have extremes not only of permeability and porosity but also of the constitutive models needed for multiphase flow; additionally, they have process models like salt creep closure reducing porosity over time, fracturing in clay and anhydrite interbeds of the bedded salt, gas generation from the waste materials, and unintentional human borehole intrusions in some scenarios. Numerical simulations require the solution of coupled systems of nonlinear PDEs; in our work, we use the open-source simulator PFLOTRAN which is based on Finite Volume discretization. The solution of the nonlinear equations requires use of the Newton-Raphson iteration at each time step, which entails the solution of the linearized Jacobian system at each iteration. The effects of all the processes (i.e., large number of unknowns, highly nonlinear constitutive relations, large contrasts in material properties in short distances) lead to an ill-conditioned Jacobian matrix that severely challenges traditional linear solver, i.e., stabilized biconjugate gradient with block Jacobi incomplete LU preconditioner (BCGS-ILU) leading to non-convergence for traditional Newton-Raphson nonlinear solver causing unacceptably long computation time for each model. This paper presents linear solvers such as constrained pressure residual (CPR) two-stage preconditioner with alternate-block-factorization (ABF) and quasi- implicit pressure and explicit saturation (QIMPES) decouplers and flexible generalized residual solver (FGMRES). The new general-purpose nonlinear solver, Newton trust-region dogleg Cauchy (NTRDC), is also introduced to resolve extreme nonlinearities in the models. We demonstrate the effectiveness of each method relative to the default BCGS-Newton solver. The two best cases had nearly 50 times speed-up and achieved completion of a simulation in 14 hours that never completed due to non-convergence with the default solver. We also investigate the strong scalability of each method and discuss some of the deficiencies found for Block Jacobi preconditioner using parallel domain decomposition, and node packing effects of modern processor architecture.

Preconditioner, Nonlinear, Porous media, Multiphas↗

Tar Formation and Mitigation in Pressurized Biomass and Cofired Gasification

Biomass gasification with CO2 capture has the potential to provide carbon-negative heat, power, and feedstock for sustainable hydrocarbon fuels. In a pressurized gasifier, precombustion solvent systems can capture CO2 with less energy than needed for amine-based postcombustion CO2 capture, and pressurized syngas is generally more suitable for fuel synthesis. Although precombustion capture has been used for many decades in large-scale fossil-based plants, it has not been well-demonstrated in smaller-scale biomass gasification. Precombustion solvents and product streams could be particularly impacted by tar and other organic compounds that tend to form in high concentrations during low-temperature biomass gasification. A pressurized pilot-scale gasifier was used to examine tar formation and fate when using CO2 capture with various blends of biomass and coal. The syngas was fully conditioned to remove particulate matter; capture sulfur; adjust syngas chemistry using water-gas shift; quench out moisture and condensable organics; and capture CO2. Tar concentrations were measured in the raw syngas, the product gas, and in the liquid streams over the course of several weeks. The gasifier was operated both as a high-pressure oxygen-blown system to mimic large-scale centralized gasification and at lower pressures under air-blown conditions to mimic a more likely small-scale system. A second high-temperature stage with oxidant injection was used to crack tars. The overall results showed how gasifier and CO2 capture performance change as fuel is blended between coal to biomass and what the fate of tar is through a precombustion CO2 capture system.

Strege, Josh [University of North Dakota EERC] (OR↗

Scale-up Testing of Advanced Polaris Membrane in CO2 Capture Technology

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the U.S. Department of Energy (DOE), National Energy Technology Lab (NETL) on the scale-up and testing of advanced Polaris™ membrane CO2 capture technology at the Technology Centre Mongstad (TCM) under award number DE-FE0031591. The work was performed from August 1, 2018 through January 31, 2023. The overall goal of this project was to design, build and operate an advanced Polaris membrane CO2 capture system at TCM. MTR was assisted in this project by Trimeric Corporation (Trimeric), an engineering design services company, the Carbon Capture Simulation for Industry Impact (CCSI2), a partnership among national laboratories, industry, and academic institutions, and the Technology Centre Mongstad (TCM), who provided the host site for the slipstream field test. This report details the work conducted to scale-up MTR’s second-generation (Gen-2) Polaris membrane and advanced planar membrane modules to a final form factor optimized for commercial use; validate their performance in an engineering-scale field test at TCM; and to show the potential of the MTR process to meet DOE CO2 capture targets from large source point emitters. Work for this project included membrane optimization and scale-up, advanced planar module design and fabrication, design and fabrication of an engineering-scale field test membrane skid, operation of the field test skid processing Residue Fluid Catalytic Cracker (RFCC) industrial flue gas at TCM, and a detailed techno-economic analysis (TEA) of the MTR membrane post-combustion process for CO2 capture. This project validated recent membrane technology advancements at the engineering-scale, moves the MTR advanced post-combustion capture technology to TRL-6, and mitigates risk in future Large Pilot or Demonstration scale-up activities.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot-Scale Continuous Plug-Flow Hydrothermal Liquefaction of Food Waste for Biocrude Production

Pilot-scale hydrothermal liquefaction (HTL) of biowaste is a critical step toward commercialization of the HTL technology. Despite many HTL studies conducted with wet biomass, including food waste, few were performed with a pilot-scale continuous plug-flow reactor (PFR), with the biocrude yield and quality analysis based on dewatering (ASTM D2892 Annex X1). This paper describes the development and performance evaluation of a mobile pilot-scale HTL continuous PFR, with a processing capacity of 60 L/h of wet feedstock and 6 L/h of biocrude production. The reactor system was designed for reaction conditions of up to 325 °C and 17.25 MPa. The reactor has a volume of 28.88 L with an additional counterflow heat exchanger volume of 18.07 L. Two types of food wastes, from a food processing plant and grocery store, were processed at 280 °C for 30 min, producing biocrude oil yields of 52.19 and 47.06 wt %, energy recoveries of 68.17 and 70.77%, and carbon recoveries of 66.91 and 64.78%, respectively. Furthermore, due to its high feedstock capacity and reaction volume, large amounts of biocrude oil and post-HTL wastewater (PHW) were obtained from this pilot-scale reactor to allow downstream research on upgrading biocrude oil for transportation fuel as well as PHW treatment and nutrient recovery.

09 BIOMASS FUELS↗

Developing solid-surface plasma facing components for pilot plants and reactors with replenishable wall claddings and continuous surface conditioning. Part B: required research in present tokamaks

Abstract The companion part A paper (Stangeby et al 2022) reports a number of independent estimates indicating that high-duty-cycle DT tokamaks starting with pilot plants will likely experience rates of net erosion and deposition of solid PFC, plasma facing component, material in the range of 10 3 to 10 4 kg yr −1 , regardless of the material used. The subsequent redeposition of such large quantities of material has the potential for major interference with tokamak operation. Similar levels and issues will be involved if ∼continuous low-Z powder dropping is used for surface conditioning of DT tokamaks, independent of the material used for the PFC armor. In Stangeby et al (2022) (part A) it is proposed that for high-duty-cycle DT tokamaks, non-metallic low-Z refractory materials such as ceramics (graphite, SiC, etc) used as in situ replenishable, relatively thin—of order mm—claddings on a substrate which is resistant to neutron damage could provide a potential solution for protecting the main walls, while reducing the risk of degrading the confined plasma. Assessment of whether such an approach is viable will require information, much of which is not available today. Section 6 of part A identifies a partial list of major physics questions that will need to be answered in order to make an informed assessment. This part B report describes R&D needed to be done in present tokamaks in order to answer many of these questions. Most of the required R&D is to establish better understanding of low-Z slag generation and to identify means to safely manage it. Powder droppers provide a unique opportunity to carry out controlled studies on the management of low-Z slag in current tokamaks, independent of whether their protection tiles use low-Z or high-Z material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scale-up of Next Generation Nano-Enhanced Composite Materials for Longer Lasting Consumer Goods

The objective for this project was to create an industrial-scale manufacturing operation for Vertically Aligned Carbon Nanotube Forests (VACNTs), which make up N12 Technologies’ (N12) NanoStitch® product, a prepreg additive that makes advanced composites tougher, lighter, and more durable. This was achieved using University of Dayton Research Institute’s (UDRI) 60-inch Nano Adaptive Hybrid Fabric (NAHF-X) reactor system. N12 had a unique and effective nanomaterial-based product that they were manufacturing on small-scale 1-inch wide substrate machines in Boston, MA. UDRI had a large-scale 60-inch wide nanomaterial growth reactor available for scaling up 2nd party products in Dayton, OH. Thanks to the successful cooperation between both parties, this project resulted in the world’s first industrial-scale continuous VACNT film pilot plant in Dayton, OH with an increase in VACNT supply production rate of >10X. This scale up enabled market validation via testing programs and pilot manufacturing operations with a number of customers.

36 MATERIALS SCIENCE↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stellarator fusion systems enabled by arrays of planar coils

We present an overview of a novel electromagnetic coil configuration for stellarators and its application to two near-term fusion systems. The novel coil configuration is the planar coil stellarator, able to implement precisely-quasisymmetric 3D magnetic fields using a set of planar, plasma-encircling coils and a set of planar, field-shaping coils situated on a surface surrounding the plasma. This configuration combines the stellarator’s advantages of steady-state operation, stability, low recirculating power fraction, and a mature physics basis, with the benefits of using simpler, planar coils which allow for a maintenance scheme leveraging large ports, and the ability to control magnets individually. The initial near-term use case considered is a steady state deuterium–deuterium stellarator neutron source, called Eos. The second near-term use case considered is a deuterium–tritium stellarator fusion pilot plant, called Helios, that would be approximately twice the linear dimension of the Eos design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbon Capture Pilot at Dry Fork Power Station (Final Technical Report)

The objective of this project was to design, seek necessary approvals, build and operate a large-scale pilot sorbent-based post combustion carbon capture system (CCS) at a coal fired power generation facility. TDA’s CCS uses a highly stable, low-cost, high-capacity physical adsorbent to effectively remove CO 2 via a combination vacuum and concentration swing adsorption (VCSA) process. The CCS is integrated with the power plant flue gas exhaust, which is rich in CO 2 (~13% vol. CO 2 ) and removes more than 90% of the plant’s overall carbon emissions.

01 COAL, LIGNITE, AND PEAT↗

Development of Magnesium Oxysulfate Formulation for SRPPF Aqueous Recovery Liquid Solidification

The liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery Processes will be solidified into a stable form that is acceptable by Waste Isolation Pilot Plant (WIPP) for disposal. The current Aqueous Recovery flow sheet proposes to solidify the liquid effluent using a grout formula that was developed and tested for the former Waste Solidification Building process. This Portland cement based mixture results in a high pH (~13) leachate from the solidified waste form which is not acceptable to WIPP in the large quantities expected from production at SRPPF. Various cementitious materials were previously evaluated as alternative grout formulations to Portland cement and a MgO-based mix was identified as a promising alternative. A magnesium oxysulfate (MOS) cement formulation comprised of reactive magnesium oxide (MgO), anhydrous magnesium sulfate (MgSO 4 ), and sand, as a non-reactive heat sink provided good mixability, similar density to the original Portland-cement based mix, and a leachate pH of 9.4, within the assumed WIPP brine pH range. However, the MOS formulation exhibited an appreciable amount of heat generation, which resulted in premature setting of a large-scale test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗