Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Photonics Breakthroughs 2024: Narrow-Linewidth Lasers in the Visible and Near-Infrared

Narrow-linewidth lasers enable a variety of high-precision applications, such as sensing, optical clocks, and microwave frequency generation. Advances in photonic integration in the last decade led to the development of ultra-low-noise integrated semiconductor lasers, mostly in the telecom wavelength range. In recent years, the demand for high-performance lasers at shorter wavelengths skyrocketed, driven by applications in sensing and atom trapping. Low-noise lasers are of particular importance in this spectral range, as they are essential for optical clocks. Here, we will review recent progress in narrow-linewidth lasers at shorter wavelengths, present results on a hybrid-integrated low-noise laser at 780 nm and discuss the perspectives and challenges of high-performance semiconductor lasers in the visible and near-infrared.

Prokoshin, Artem [King Abdullah University of Scie↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Backscatter-Immune Injection-Locked Brillouin Laser in Silicon

As self-sustained oscillators, lasers possess the unusual ability to spontaneously synchronize. These nonlinear dynamics are the basis for a simple yet powerful stabilization technique known as injection locking, in which a laser’s frequency and phase can be controlled by an injected signal. Because of its inherent simplicity and favorable noise characteristics, injection locking has become a workhorse for coherent amplification and high-fidelity signal synthesis in applications ranging from precision atomic spectroscopy to distributed sensing. Within integrated photonics, however, these injection-locking dynamics remain relatively untapped—despite significant potential for technological and scientific impact. In this work, we demonstrate injection locking in a silicon photonic Brillouin laser. Injection locking of this monolithic device is remarkably robust, allowing us to tune the laser emission by a significant fraction of the Brillouin gain bandwidth. Harnessing these dynamics, we demonstrate amplification of small signals by more than 23 dB. Moreover, we demonstrate that the injection-locking dynamics of this system are inherently nonreciprocal, yielding unidirectional control and backscatter immunity in an all-silicon system. This device physics opens the door to strategies for phase-noise reduction, low-noise amplification, and backscatter immunity in silicon photonics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated photonic molecule Brillouin laser with a high-power sub-100-mHz fundamental linewidth

Photonic integrated lasers with an ultra-low fundamental linewidth and a high output power are important for precision atomic and quantum applications, high-capacity communications, and fiber sensing, yet wafer-scale solutions have remained elusive. Here we report an integrated stimulated Brillouin laser (SBL), based on a photonic molecule coupled resonator design, that achieves a sub-100-mHz fundamental linewidth with greater than 10-mW output power in the C band, fabricated on a 200-mm silicon nitride (Si 3 N 4 ) CMOS-foundry compatible wafer-scale platform. The photonic molecule design is used to suppress the second-order Stokes (S2) emission, allowing the primary lasing mode to increase with the pump power without phase noise feedback from higher Stokes orders. The nested waveguide resonators have a 184 million intrinsic and 92 million loaded Q, over an order of magnitude improvement over prior photonic molecules, enabling precision resonance splitting of 198 MHz at the S2 frequency. We demonstrate S2-suppressed single-mode SBL with a minimum fundamental linewidth of 71±18 mHz, corresponding to a 23±6-mHz 2 /Hz white-frequency-noise floor, over an order of magnitude lower than prior integrated SBLs, with an ∼11-mW output power and 2.3-mW threshold power. The frequency noise reaches the resonator-intrinsic thermo-refractive noise from 2-kHz to 1-MHz offset. The laser phase noise reaches −155 dBc/Hz at 10-MHz offset. The performance of this chip-scale SBL shows promise not only to improve the reliability and reduce size and cost but also to enable new precision experiments that require the high-speed manipulation, control, and interrogation of atoms and qubits. Realization in the silicon nitride ultra-low loss platform is adaptable to a wide range of wavelengths from the visible to infrared and enables integration with other components for systems-on-chip solutions for a wide range of precision scientific and engineering applications including quantum sensing, gravitometers, atom interferometers, precision metrology, optical atomic clocks, and ultra-low noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Continuous recoil-driven lasing and cavity frequency pinning with laser-cooled atoms

Abstract Laser-cooled gases of atoms interacting with the field of an optical cavity are a versatile tool for quantum sensing and the simulation of quantum systems. These systems can exhibit phenomena such as self-organization phase transitions, lasing mechanisms, squeezed states and protection of quantum coherence. However, investigations of these phenomena typically occur in a discontinuous manner due to the need to reload atomic ensembles. Here we demonstrate hours-long continuous lasing from laser-cooled 88 Sr atoms loaded into a ring cavity. The required inversion to produce lasing arises from inversion in the atomic-momentum degrees of freedom, which is linked to the self-organization phase transitions and collective atomic recoil lasing observed previously only in a cyclic fashion. We find that over a broad parameter range, the sensitivity of the lasing frequency to changes in cavity frequency is significantly reduced due to an atomic loss mechanism, suggesting a potential approach for mitigating low-frequency cavity noise. Our findings open opportunities for continuous cavity quantum electrodynamics experiments and robust and continuous super-radiant lasers.

Schäfer, Vera M. (ORCID:0000000210003737)↗

Thin film lithium niobate electric field sensors

We present our results for using thin film lithium niobate devices for electric field sensing applications. Micro-ring modulator and Mach–Zehnder modulator-based electric field sensors are demonstrated. Micro-ring resonator sensors can be used for low frequency (up to several GHz) electric field sensing applications and achieve a high sensitivity of 80 mV/(m Hz 1/2 ) with a very compact size of 300 μm, as limited by the intensity and phase noise of the used distributed feedback laser. A measurement bandwidth of 2.5 GHz is measured for these sensors and is limited by the detector bandwidth. Alternatively, Mach–Zehnder modulators allow for perfect phase matching between the radio frequency signals and optical signals, and they can be used for electric field sensing up to several THz. A sensitivity of 2.2 V/(m Hz 1/2 ) was obtained using our Mach–Zehnder electric field sensor with an interaction length of 600 μm. The Mach–Zehnder sensor can sense electric fields with frequencies reaching 0.6 THz based on the calculated results.

47 OTHER INSTRUMENTATION↗

EXPRES. I. HD 3651 as an Ideal RV Benchmark

The next generation of exoplanet-hunting spectrographs should deliver up to an order of magnitude improvement in radial velocity (RV) precision over the standard 1 m s{sup −1} state-of-the-art spectrographs. This advance is critical for enabling the detection of Earth-mass planets around Sun-like stars. New calibration techniques such as laser frequency combs and stabilized etalons ensure that the instrumental stability is well characterized. However, additional sources of error include stellar noise, undetected short-period planets, and telluric contamination. To understand and ultimately mitigate error sources, the contributing terms in the error budget must be isolated to the greatest extent possible. Here, we introduce a new high-cadence RV program, the Extreme Precision Spectrograph (EXPRES) 100 Earths Survey, which aims to identify rocky planets around bright, nearby G and K dwarfs. We also present a benchmark case: the 62 day orbit of a Saturn-mass planet orbiting the chromospherically quiet star, HD 3651. The combination of high eccentricity (0.6) and a moderately long orbital period ensures significant dynamical clearing of any inner planets. Our Keplerian model for this planetary orbit has a residual rms of 58 cm s{sup −1} over a ∼6 month time baseline. By eliminating significant contributors to the RV error budget, HD 3651 serves as a standard for evaluating the long-term precision of extreme precision RV programs.

79 ASTRONOMY AND ASTROPHYSICS↗

A characterization of quantum Kerr optical frequency combs

Quantum Kerr optical frequency combs are generated by pumping a high-Q microresonator with a continuous wave resonant laser. Below threshold, two pump photons are symmetrically up- and down-converted as twin photons via spontaneous four-wave mixing, thereby generating up to a hundred paired channels. Furthermore, these chipscale, high-dimensional and room-temperature systems are expected to play a major role in quantum engineering. However, their theoretical description is still unclear. Here, we present an explicit description of this quantum system via a frequency-bin state and its density operator, and explore the properties of the eigenkets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Pipeline Monitoring Using Highly Sensitive Vibration Sensor Based on Fiber Ring Cavity Laser

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18” diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.

47 OTHER INSTRUMENTATION↗

Quantum limits of superconducting-photonic links and their extension to millimeter waves

Photonic addressing of superconducting circuits has been proposed to overcome wiring complexity and heat-load challenges. However, such superconducting-photonic links suffer from an efficiency-noise trade-off that limits scalability. This trade-off arises because increasing power conversion efficiency entails reducing optical power, which makes the converted signal susceptible to shot noise. We analyze this trade-off and find that the laser-driven qubit gate infidelity scales inversely with the number of photons used. While methods such as nonlinear detection or squeezed light could mitigate this effect, we consider generating higher-frequency electrical signals, such as millimeter waves (100 GHz), using laser light. At these higher frequencies, circuits have higher operating temperatures and cooling power budgets and alleviate constraints posed by the trade-off. Therefore, we demonstrate an optically driven cryogenic millimeter-wave source with a maximum power efficiency of 8 ×10 −5 that can generate a maximum of 0.7 μ⁢W of 80 GHz power, with a 1200-thermal-photon equivalent of added noise at 4K. Using this source, we perform frequency-domain spectroscopy of superconducting NbTiN resonators at 80–90 GHz. Our results show a promising approach to lessen the efficiency-noise constraints on superconducting-photonic links, while leveraging the benefits of photonic signal delivery. Further optimization of power efficiency and noise at high frequencies could make scalable photonic control of superconducting qubits viable at temperatures exceeding 1K.

Optoelectronics↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

New Fracture Diagnostic Tool for Unconventionals: High-Resolution Distributed Strain Sensing via Rayleigh Frequency Shift during Production in Hydraulic Fracture Test 2

Fiber Optic monitoring in unconventional reservoirs has proven to be an invaluable diagnostic tool for assessing both near-wellbore stimulation effectiveness and to help describe the far-field frac geometries created by hydraulic fracture stimulation. Unfortunately, gaining any detailed qualitative and quantitative understanding of the near-wellbore frac geometry or cluster/stage productivity during production via Fiber Optic (FO) has proven to be more difficult, particularly in wells producing liquids. A new FO diagnostic method, Distributed Strain Sensing based on Rayleigh Frequency Shift (DSS-RFS), first demonstrated for oil and gas applications in the Hydraulic Test Site 2 (HFTS2) provides new insights about the characteristics of near-wellbore-region (NWR) during production. DSS-RFS is different from other FO strain measurements because it relies on accurate measurement of frequency shifts of Rayleigh backscattered spectrum obtained by scanning the fiber with a coherent optical time-domain reflectometer with a range of laser frequencies using a tunable-wavelength laser system. Changes in strain are measured with an extremely high spatial resolution of 20 cm and with high signal-to-noise ratios over long distances. In HFTS2, strain changes for the entire wellbore have been measured twice during scheduled shut-in and reopening operations (February 2020 and September 2020). After removing temperature effects, consistent strain changes have been observed at the location of most perforation clusters. These are caused by near wellbore fracture aperture changes due to pressure increases during shut-in within the near-wellbore fracture network. The strain-change patterns from the DSS-RFS during shut-in correlate very well with the location of clusters and allow for the definition of extending intervals with positive strain signals at each cluster and slightly compressing intervals with negative strain signals between the clusters and in the non stimulated intervals. The locations of the measured positive strain peaks also show good correspondence to DAS acoustic intensity measurements acquired during the stimulation. The geometry and magnitude of the strain changes differ significantly between the two tested completion designs in the same well. During shut in and reopening each cluster exhibit its own strain-change / pressure path. In addition, the September 2020 dataset also revealed the existence of small but measurable strain changes as consequence of pressure decline during production. These strain changes also correlate well with the presence of producing clusters, but the strain-rate signals are opposite to that obtained during shut-in and reopening operations. Although Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R002/2477551/urtec-2021-5408-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5408 2 we are still in the early stages of exploring the potential of this novel FO technique, we believe that the highly detailed information contained in the measurement of strain changes using DSS-RFS during production can significantly improve our understanding of near-wellbore hydraulic fracture characteristics and the relationships between stimulation and production from unconventional oil and gas wells.

04 OIL SHALES AND TAR SANDS↗