Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser-induced fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Airborne laser induced fluorescence system for measuring OH and other trace gases in the parts-per-quadrillion to parts-per-trillion range

Described in detail is a laser induced fluorescence system which has been successfully interfaced with two aircraft sampling platforms (i.e., Sabreliner jet and an L-188C Electra). This system, which has been under development for four years, presently consists of the following major components: (1) a Nd-Yag laser driven oscillator-amplifier dye laser; (2) a sampling manifold with associated fluorescence detection optics; (3) an OH calibration chamber; (4) a laser beam steering assembly; and (5) sampling electronics and data processing hardware. During the last three years, this system has been flown some 50,000 air miles making tropospheric OH radical measurements over the latitude range of 70 N to 57 S. OH concentrations measured during these flights have ranged from 30 parts-per-quadrillion (3.7 x 10 to the 5th molecules/sq cm) at altitudes of 6 km to 0.8 parts-per-trillion (2.0 x 10 to the 7th molecules/sq cm) at 0.5 km. Computations have been completed which indicate that the existing aircraft system with modest modifications should also be capable of detecting natural tropospheric levels of NO, SO2, CH2O, NO2, HNO2, NO3, H2O2 and CS2 by using both conventional laser-induced fluorescence methodology and multiphoton techniques.

Davis, D. D.↗

Production of OH from photolysis of HOCl at 307-309 nm

Laser-induced fluorescence has been used to measure the amount of OH produced in the laser photolysis of HOCl at 310 nm. The HOCl was generated by the Cl2O + H2O and by the HCl + Cl2O reactions. The laser technique samples OH on a microsecond time scale so that secondary radical reactions cannot contribute significantly to the observed signals. The fluorescence signals were calibrated with O3-H2O mixtures, the reactions O3 + h(nu) yields O(1D) + O2 and O(1D) + H2O yields 2OH yielding known amounts of OH. The value for the absorption cross section of HOCl at 310 nm has been determined to be 6 x 10 to the -20th sq cm, assuming K(eq) = 0.082 for the Cl2O + H2O yields 2HOCl system and assuming unit quantum yield for the production of OH. The present investigation further supports earlier experimental work concluding that HOCl will photodissociate rapidly and will not be an important holding tank for chlorine in the stratosphere. These results are in disagreement with theoretical calculations of the UV absorption spectrum of HOCl in the 300-350-nm wavelength region.

Molina, M. J.↗

Kinetics of the reaction OH + HO2 yields H2O + O2 at 296 K

The rate constant of the title reaction was measured in a discharge-flow reactor by addition of excess HO2 from a movable double injector to a gas stream containing small concentrations of OH. The concentration of OH was measured by laser-induced fluorescence, HO2 by conversion to OH, and H and O by vacuum-UV resonance fluorescence. Five sets of experiments, each with different excess concentration of HO2, gave an average rate constant of (7.5 + or - 1.2) x 10 to the -11th cu cm/s where the error limits (single sigma) include uncertainties of all experimental parameters. This result is compared with other findings and is discussed in terms of its importance in stratospheric chemistry and in rate theory.

Sridharan, U. C.↗

Radiative lifetimes and quenching rate coefficients for directly excited rotational levels of OH/A 2Sigma +, v-prime = 0/

A narrow-bandwidth pulsed dye laser was used to excite OH X 2Pi i radicals to the A 2Sigma(+) state by pumping in the (0, 0) vibrational band around 308 nm. The radiative lifetimes of specific (K-prime, J-prime) rotational levels in v-prime = 0 were measured at low pressures (not greater than 1 mtorr), which yielded a mean lifetime of 0.71 + or - 0.009 microsec (2 sigma). Electronic quenching rate constants for N2, O2, H2O, and H2 were measured for a range of initially excited rotational levels. A strong dependence of this rate constant on the initially excited rotational level was found for N2, and less markedly for O2, with the rate constant tending to increase for the lowest rotational levels K-prime not greater than 3. The implications of these results for the laser-induced fluorescence detection of atmospheric OH are discussed.

Mcdermid, I. S.↗

Rate constant and possible pressure dependence of the reaction OH + HO2

The technique of laser-induced fluorescence is used to measure steady-state OH concentrations in the photolysis of water vapor at 184.9 nm and 298 K, with O2 added in trace amounts. He or Ar is present at total pressures in the range 75-730 torr. The results are used in deriving the rate-constant ratio of k1 to k5 to the 1/2 power, where k1 and k5 are the rate constants for the reactions OH + HO2 = H2O + O2 and HO2 + HO2 = O2, respectively. When available values of k5 are used, the results give k1 = (1.2 + or - 0.4) x 10 to the -10 cu cm/s at 1-atm pressure, with evidence of a decline of k1 at lower pressures. No water-vapor effect on k1 is observed.

Demore, W. B.↗

Stratospheric ozone and hydroxyl radical measurements by balloon-borne lidar

An experiment is reported in which a balloon-borne lidar system was used to measure ozone and the hydroxyl radical in the stratosphere by two lidar techniques. Ozone was measured in the 20-37 km altitude range using differential absorption lidar, and the hydroxyl radical was measured in the 34-37 km range using remote laser-induced fluorescence. Ozone concentrations were determined with a vertical resolution of 0.5 km, and in addition, horizontally resolved ozone measurements with 0.15-km resolution were obtained over a 2-km range. The temporal variation of the hydroxyl radical concentration ranged from 40 parts/trillion shortly after noon to about 5 parts/trillion two hours after sunset. Possible modifications to the system are discussed which can yield an improvement in the sensitivity of between one and two orders of magnitude, thus permitting measurements of the hydroxyl radical in the 20-30-km altitude range.

Heaps, W. S.↗

Density measurement in compressible flows using off-resonant laser-induced fluoresence

Measurement of molecular number density in compressible flows using laser-induced fluorescence is complicated by collisional quenching of the exicited state. It is shown that by exciting the fluorescence off-resonance the signal becomes proportional to number density and independent of collisional effects. Quantitative measurement of density in an underexpanded jet of nitrogen is demonstrated using off-resonant fluoresence from iodine seed molecules irradiated with the 514.5 nm line of the argon-ion laser.

Mcdaniel, J. C.↗

Determination of accurate dissociation limits and interatomic interactions at large internuclear distances

This paper illustrates (using the molecules LiH, Li2 and Na2) how laser-induced fluorescence can be used to greatly expand the range of observed vibrational levels in ground electronic states. This expanded vibrational range leads to the determination of virtually the full well of the potential energy curve. This also leads to improved determination of the dissociation limit and serves as a severe test for highly accurate ab initio calculations now available for many small molecules.

Stwalley, W. C.↗

Development of compact excimer lasers for remote sensing

The capabilities of excimer lasers for remote sensing applications are illustrated in a discussion of the development of a compact tunable XeCl excimer laser for the detection of atmospheric OH radicals. Following a brief review of the operating principles and advantages of excimer lasers, measurements of the wavelength dependence of the net small signal gain coefficient of a discharge excited XeCl laser are presented which demonstrate the overlap of several absorption lines of the A-X(0,0) transition of OH near 308 nm with the wavelengths of the XeCl laser. A range of continuous narrow bandwidth tunability of from 307.6 to 308.4 nm with only a 30 percent variation in output is reported for an XeCl laser used as a double-pass amplifier for a frequency-doubled dye laser, and measurements demonstrating the detection of laser-induced fluorescence from OH in a methane-oxygen flame are also noted. The design of an oscillator-amplifier excimer system comprising a corona-preionized, transverse-discharge oscillator and amplifier is then presented. Output energies of 12-15 mJ have been achieved in the regions where injection locking was established, with energies of 8-10 mJ elsewhere.

Laudenslager, J. B.↗

Evaluation of non-intrusive flow measurement techniques for a re-entry flight experiment

This study evaluates various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle orbiter or a similar reentry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser-Induced Fluorescence) light scattering, electron-beam fluorescence, thermal emission, and mass spectroscopy. Flow-field properties were taken from a nonequilibrium flow model by Shinn, Moss, and Simmonds at the NASA Langley Research Center. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.↗

Production of NO2 from Photolysis of Peroxyacetyl Nitrate

Peroxyacetyl nitrate (PAN) vapor was photolyzed at 248 nm, and the NO2 photoproduct was detected by laser-induced fluorescence. The quantum yield for the production of NO2 from PAN photolysis was determined by comparison to HNO3 photolysis data taken under identical experimental conditions. The average of data collected over a range of total pressures, precursor concentrations, and buffer gases was 0.83 +/- 0.09 for the NO2 quantum yield, where the statistical uncertainty is 2 standard deviations.

Mazely, Troy L.↗

Nonintrusive Diagnostic Strategies for Arcjet Stream Characterization

In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.

Fletcher, Douglas G.↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Delineation of estuarine fronts in the German Bight using airborne laser-induced water Raman backscatter and fluorescence of water column constituents

The acquisition and application of airborne laser induced emission spectra from German Bight water during the 1979 MARSEN experiment is detailed for the synoptic location of estuarine fronts. The NASA Airborne Oceanographic Lidar (AOL) was operated in the fluorosensing mode. A nitrogen laser transmitter at 337.1 nm was used to stimulate the water column to obtain Gelbstoff or organic material fluorescence spectra together with water Raman backscatter. Maps showing the location and relative strength of estuarine fronts are presented. The distribution of the fronts indicates that mixing within the German Bight takes place across a relatively large area. Reasonable agreement between the patterns observed by the AOL and published results are obtained. The limitations and constraints of this technique are indicated and improvements to the AOL fluorosensor are discussed with respect to future ocean mapping applications.

Hoge, F. E.↗

Pulsewidth dependence of ozone interference in the laser fluorescence measurement of OH in the atmosphere

By varying the pulsewidth of the output from two dye lasers, it is verified experimentally that the steady-state interference level of OH due to laser-induced dissociation of ozone decreases linearly with decreasing pulsewidth of the exciting radiation. At low pressures, further reduction in the interference level due to the transient nature of OH formation processes was also observed. These results should greatly facilitate measurements of OH concentrations in the atmosphere.

Hanabusa, M.↗