Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser-induced fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dynamics of argon metastables in Ar–CH 4 radio frequency capacitively-coupled plasma: real-time monitoring with neural network-augmented broadband optical emission spectroscopy

In moderate-pressure radio frequency (RF) capacitively coupled plasmas generated in argon–methane mixtures, the density of argon metastable atoms (Ar 1 s 5 ) exhibits a non-monotonic dependence on methane (CH 4 ) concentration. Laser-induced fluorescence (LIF) was used to measure and compare local Ar 1 s 5 densities in Ar and Ar–CH 4 plasmas at 2.6 Torr and RF powers of 17–117 W. The addition of 1% CH 4 increases the metastable density, and 2% CH 4 triggers a strong depletion by an order of magnitude, compared to 1% CH 4 case. This non-monotonic behavior demonstrates the sensitivity of metastable populations to small gas admixtures, which is critical for processes where metastables drive precursor dissociation. For real-time monitoring of metastable population, broadband optical emission spectroscopy (OES) is augmented with a feedforward neural network (NN) to predict Ar s1 5 densities from spectral features. When trained on LIF data, the NN replicates the absolute densities and the dynamic trends of Ar 1 s 5 density variation. The NN-augmented broadband OES approach can be used as a simple and cost-effective tool for tracking Ar metastables in Ar-rich plasmas, facilitating industrial-scale optimization.

Yatom, Shurik [Princeton Plasma Physics Laboratory↗

Generative Physics-Informed Neural Network Solving Multi-Scale and Multi-Phase Plasma Chemical Flow Field

Low-temperature plasmas (LTPs) are non-equilibrium systems with near-room-temperature gas and highly energetic electrons. This makes them ideal for delicate applications in biomedicine and semiconductor manufacturing, enabling processes like wound healing, sterilization, etching, and plasma-enhanced chemical vapor deposition without thermal damage. However, LTPs involve complex chemistries, with hundreds of species and thousands of reactions, complicating their diagnosis, prediction, and control. Conventional diagnostics, such as Fourier-transform infrared spectroscopy (FTIR), laser-induced fluorescence (LIF), and optical emission spectroscopy (OES), offer limited species detection, while mass spectrometry (MS) struggles with low-sensitivity species. Additionally, LTP simulations face multi-scale challenges, as macroscopic fluid dynamics and microscopic particle collisions operate on vastly different timescales. To address these issues, we developed an artificial intelligence (AI) based diagnostic system: a generative physics-informed neural network (PINN-Gen) that can predict spatially resolved species concentrations and temperatures in LTPs by integrating experimental data from planar LIF with microscopic plasma chemical kinetics and macroscopic fluid mechanics, including plasma-liquid interactions at the interface between two phases. PINN-Gen solves no equations but checks the errors of physical laws by substituting the output from neural network, and the comparison with the experimental results. Thus, it naturally avoids the multi-scale difficulty of numerical simulations and predicts the results of conventionally unsolvable multi-scale and multi-phase problems. The real-time prediction will be robust due to the physical information used in the training of such a neural network, and only very limited input of condition required due to its generative feature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of trace contaminants released from rapidly heated pulsed power electrodes by laser diagnostics

Development of a capability to measure trace gas contaminants released from pulsed power electrodes would immediately impact Sandia pulsed power research. These releases occur during ultra-fast heating of metal electrodes during pulsed power discharges and can lead to substantial power losses through plasma formation. Detection of contaminants is a formidable challenge due to the need for in-situ spatially and temporally resolved measurements of trace gases in the extreme environment of ultra-fast heated metal surfaces. We investigate the feasibility of laser diagnostics for detecting contaminants, including H-atom, OH, and H 2 O. Laser-induced fluorescence and photofragmentation fluorescence showed significant plasma emission interferences and did not yield any detectable H-atom, OH, or H 2 O. Our newly developed H-atom detection using femtosecond degenerate four-wave mixing suppressed interferences and enabled detection of H-atoms. A few shots showed large signals in the near-surface region of metal foils, suggesting the formation of a wave of H-atoms from the metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions of a Microdischarge with a Premixed Flame (Final Technical Report)

In this project we introduced an experimental platform that facilitates the study of the two-way interaction of plasma and flame, and the exploration of the impact of the spatial location of the discharge on its kinetics, in a controlled environment. The experimental platform is a mesoscale CH4/air premixed flame burner that also acts as a dielectric barrier discharge (DBD) operated by nanosecond pulsed voltage. A unique feature of this setup is that the DBD utilizes transparent electrodes, made of Indium Tin Oxide (ITO), to unlock optical access along the line-of-sight parallel to the dominant electric field. This platform is suitable to study both the forward problem (impact of plasma-on-flame), which manifests itself as a modified flame speed as well as flame wrinkling; and the backward problem (impact of flame-on-plasma), which includes plasma regime transitions, between microdischarges and uniform modes, driven by the flame passage. Prior work at MIT has focused on electrical measurements and direct imaging studies of the plasma-flame interaction through the ITO electrode. This project, which was awarded experimental runtime at the Low-temperature Plasma Research Facility (PRF) at Sandia National Laboratories, quantifies the flame-plasma interaction through temporally resolved measurement of key radicals (oxygen atom, O) produced by the nanosecond repetitively pused discharge (NRPD) in an individual microdischarge, using two-photon absorption laser-induced fluorescence (TALIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

100 kHz OH PLIF of High-Pressure H2/NH3 and H2/CH4 Flames

The reaction zones in a multi-element, multi-stage, micromix injector are investigated using planar laser-induced fluorescence (PLIF) imaging of the hydroxyl (OH) radical at a 100 kHz repetition rate. The combustor is operated at a pressure of ∼10 bar. Multiple fuel blends of hydrogen, methane, and ammonia are considered to study the effect of changing fuel composition on the flame structure. Compact regions of high OH signal are observed in each flame for fuel mixtures with high hydrogen content, indicating rapid reactant consumption in the shear layers. Instantaneous images exhibit wrinkled flame fronts and the formation of unreacted pockets due to highly turbulent burning. The addition of methane is observed to reduce the reactivity and flame speed, resulting in more diffuse regions of OH between each flame. The shape of the reactant core is altered, and the length scale of the flame surface wrinkling is increased. Ammonia addition has a more severe effect on the distribution of OH and the local flame structure than methane addition. A time series of images shows the presence of OH vortical structures and significant turbulent fluctuations in the flames near the wall, suggesting the presence of a recirculation zone that could drive the observed disparity in flame lengths.

Hodge, Alexander J. [Purdue University]↗

OH density and water vapor concentration gradients during plasma-droplet interactions

Plasma-droplet interactions significantly promote the reactivity transfer of gas phase species from the plasma to the liquid phase. Nonetheless, experimental studies on the impact of droplet evaporation on reactive species generation in such systems remain scarce. We report the spatial distribution of water vapor and OH radical densities around a droplet (∼41 μm in diameter) in He and He-Ar plasma using laser-induced fluorescence. The results reveal a significant gradient in both water vapor and OH radical concentrations near the droplets. Mutiple droplets present in the plasma can lead to a significant accumulation of water vapor and even local quenching of the discharge. The findings are critical for developing a quantitative understanding of plasma-liquid interactions for a broad range of plasma-enabled applications in the liquid phase often involving OH radicals.

42 ENGINEERING↗

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration with Methane-Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible pre-mixing tube allowing the optical diagnostics. The testing was conducted for varied pre-mixer velocities (V) and equivalence ratio (ϕ) for 90%-100% (H2, by mole) H2/CH4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to the lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A Large Eddy Simulation (LES) with detailed chemistry combustion modeling approach was implemented along an OH* sub-mechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

flame holding↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Characterization of Flashback and Flame-Holding in a Jet-In-Crossflow Mixing Configuration with Methane-Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence (CL) diagnostics techniques. The JICF burner has an optically accessible pre-mixing tube allowing the optical diagnostics. The testing was conducted for varied pre-mixer velocities (V) and equivalence ratio (ϕ) for 90%-100% (H2, by mole) H2/CH4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashbacks were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower flux ratio which bends the jet sharply, closer toward the injection plane. The flashback was found to occur along the boundary layer, assisted by the inner wall of the pre-mixer tube. The mean OH-PLIF images characterized the flame-holding behavior where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port.

flame holding↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform-dependent air fluorescence from neutral and ionic nitrogen molecules

Laser-induced air fluorescence in the ultraviolet regime is primarily attributed to transitions between the C and B states in excited neutral N 2 molecules and between the B and X states in N$^+_2$ ions. However, the mechanism underlying the former remains contentious, as direct population to the C state by light fields is forbidden by electron spin constraints. In this work, we investigate the mechanism of air fluorescence from excited neutral N 2 molecules by carrier-envelope phase–stabilized sub–4 femtosecond pulses. Our results show that fluorescence from N$^+_2$ ions reaches a maximum with cosine-like pulses, while fluorescence from excited neutral N 2 molecules peaks with sine-like pulses. In addition, by scanning the chirp of the driving pulse, we find that ionic fluorescence is maximized with chirp-free pulses, whereas neutral fluorescence favors negatively chirped pulses. These observations, supported by classical trajectory Monte Carlo simulations, support the mechanism of intersystem crossing from excited spin-singlet states, which are populated via recollision-induced strong-field excitation.

Science & Technology - Other Topics↗

Insights into Sustainable Nitrogen Fixation by Gas-phase Spectroscopic Measurements and Global Modeling of Reaction Intermediates in Humid Nitrogen Plasma

In this article, there is growing interest in reacting molecular nitrogen and water to sustainably synthesize fixed forms of nitrogen such as ammonia. In particular, low-temperature plasmas can activate these relatively inert feedstocks at or near room temperature without a catalyst. However, because of the enhanced reactivity and nonequilibrium chemistry, a diverse range of products is formed, and the underlying reaction mechanisms are exceedingly complex. In this work, we studied a simplified reactor consisting of a gaseous plasma containing controlled mixtures of nitrogen gas and water vapor. Densities of key chemical species such as N, H, OH, NH, and NO were measured by emission and laser-based spectroscopy as a function of the relative humidity. A global model was constructed and the reaction network was validated by comparing calculated species densities with experiments. We discover that N, a key initial intermediate for ammonia, strongly decreases in the presence of water vapor, and as a result, ammonia formation becomes limited at high relative humidity. This decrease is surprisingly not because N itself reacts, but because one of its main sources, an excited molecular nitrogen state, is reacted away. In addition, oxidation pathways for nitrogen, which lead to NO and related products, are found to be favored over reduction pathways because the corresponding reverse reactions are less significant. Together, this understanding helps explain previously reported observations of selectivity toward nitrogen oxides over ammonia, particularly at higher relative humidities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid-to-gas transfer of sodium in a liquid anode glow discharge

Solute transfer from the liquid to the gas phase in plasmas has been widely used in analytical chemistry often focused on liquid cathode discharges. In this study, we report on time-resolved absolute density measurements of sodium in a glow discharge plasma with a NaCl solution anode using two-photon absorption laser induced fluorescence. The averaged maximum sodium density is found to be similar to the electron density in the discharge consistent with plasma-induced vapor generation. Random sodium flashes were also observed extending into the plasma afterglow and are attributed to sodium particles falling back on the liquid surface. Cataphoresis can explain the location of the maximum sodium density near the cathode side of the electrode gap rather than near the liquid anode region.

chemical vapor generation↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

Flame Characterization of a Hydrogen Micromix Burner using Experimental and Numerical Methods - Extended Abstract

Micromix combustion presents a promising solution for integrating hydrogen into gas turbine combustors, offering rapid and compact air-fuel mixing that effectively shortens the combustion zone and significantly reduces nitrogen oxides (NOX) emissions. A major challenge in hydrogen combustion systems is flashback, which is mitigated through short mixing lengths and high flow velocities. This study investigates three fuel injector designs – zero swirl, low swirl, and high swirl – for a 6-mm inner diameter nozzle, where hydrogen is injected through six 0.3 mm diameter holes in a jet-in-crossflow configuration relative to the airstream. Numerical simulations indicate stable flame formation, moderate peak flame temperatures, and subsequent low NOx potential for all designs. These injectors have been fabricated using additive manufacturing, and upcoming experiments will explore flame structure and NOx behavior across varying fuel injection angles, equivalence ratios and pre-mixer velocities. These efforts aim to advance the development of low-emission hydrogen micromix combustion.

hydrogen↗

Photoionization of seeded combustion products as a method of enhancing the efficiency of magnetohydrodynamic power generators

Here, in this study, we performed an experimental and computational investigation into the feasibility of utilizing photoionization to enhance the electrical conductivity of seeded oxy-fuel combustion products and improve the performance of magnetohydrodynamic (MHD) power generators. We applied a variety of optical and microwave diagnostics to study the ionization and recombination processes of potassium excited by an excimer laser in a high-velocity oxy-fuel free jet. Computational fluid dynamic (CFD) simulations were performed to model the thermophysical properties and species densities of the free jet. The CFD results were validated with position-dependent potassium concentration measurements. Electron recombination exponential lifetimes were measured through time-resolved microwave transmission. The experimental electron lifetimes were compared with lifetimes calculated from CFD-predicted species densities and literature recombination rates. It was determined that K + or O 2 are the most likely recombination partners for photoionized electrons. Time-resolved fluorescence measurements provided evidence of an ionization pathway involving a two-photon ionization of KOH . Finally, a zero-dimensional chemical kinetic model was developed to assess the fundamental viability of inducing a non-equilibrium electron population to provide a net energy return in combustion-driven MHD power generators. We determined that a high energy return is feasible for targeting electrode boundary layers with ultraviolet photoionization. We also found that photoionization could potentially lower the required temperature of the bulk gas flow.

20 FOSSIL-FUELED POWER PLANTS↗

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗