Search NASA⌕ Search

SEARCH · Search NASA

Results for “latent heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗

Real-time latent heat emission during dynamic-compression freezing of water

Abstract Dynamic compression studies have been used to study the nucleation kinetics of water to ice VII for decades. Diagnostics such as photon Doppler velocimetry, transmission loss, and imaging have been used to measure pressure/density, and phase fraction, while temperature has remained the difficult thermodynamic property to quantify. In this work, we measured pressure/density and implemented a diagnostic to measure the temperature. In doing so the temperature shows quasi-isentropically compressed liquid water forms ice at pressures below the previously defined metastable limit, and the liquid phase is not hypercoooled as previously thought above that limit. Instead, the latent heat raises the temperature to the liquid-ice-VII melt line, where it remains with increasing pressure. We propose a hypothesis to corroborate these results with previous work on dynamic compression freezing. These results provide constraints for nucleation models, and suggest this technique be used to investigate phase transitions in other materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Dynamic Modeling of Latent Heat Thermal Battery

A dynamic thermodynamic model is constructed in Modelica for the thermal battery portion of a heat pipe integrated thermal battery and is demonstrated using a shakedown test. The model is also leveraged to inform aspects of an experiment configuration. The theory section discusses modeling assumptions of the thermal battery system, establishes how melting and fusing is calculated, and how internal convection is modeled within the thermal battery. The shakedown test uses three charge-standby-discharge-standby cycles in which the charging cycles are 10 hours in length and the discharge cycles are 8 hours. System behavior including heat loss, temperature distributions and divergences, and internal convection behavior are presented. The model is then leveraged to show how experiment design can be informed through testing the model for insulation thickness impact on heat loss, round trip efficiency calculation, and heat tracing control.

25 ENERGY STORAGE↗

Intercomparison of sensible and latent heat flux measurements from combined eddy covariance, energy balance, and Bowen ratio methods above a grassland prairie

We present a comparison of four different methods of measuring sensible (H) and latent (LE) heat fluxes for a year over a mixed grass prairie ecosystem in the Nebraska SandHills [eddy covariance (EC), energy balance/Bowen ratio (EBBR), residual energy (RES), modified Bowen ratio (MBR) methods]. Additionally, we developed a set of quality control criteria for each method and present a simplification to the traditional EBBR setup. Using EC as reference, all methods yielded similar estimates of yearly H (regression slopes (m) ~ 2% from unity; H EC > H EBBR , H RES , and H MBR ). For yearly LE, EBBR and RES yielded similar estimates with EC (m ~ 2% from unity; LE EC < LE EBBR and LE RES ), while a larger bias was found from MBR (m ~ 8% from unity; LE EC > LE MBR ). At shorter time scales (~ hourly), moderate scatter was found about linear regression fits for H between EBBR and EC (R 2 = 0.81), with smaller scatter between RES and MBR, and EC (R 2 = 0.91). For LE, smaller scatter was also measured between EC, and EBBR and RES (R 2 = 0.89 and 0.87, respectively), with the larger scatter between EC and MBR (R 2 = 0.65). This suggests methods other than EC may be well suited to longer-term applications (≥ yearly), but have larger uncertainty on individual measurements.

54 ENVIRONMENTAL SCIENCES↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human‐Skin‐Inspired Adaptive Smart Textiles Capable of Amplified Latent Heat Transfer for Thermal Comfort

Thermally adaptive textiles (TATs) enable human subjects to attain thermal comfort without energy consumption, which can lead to enormous energy savings on heating, ventilation, and air conditioning (HVAC) in buildings. Herein, TAT structures which respond to the sweat and generate pores by opening an array of flap‐shaped pores patterned on the fabric surface are proposed. A moisture‐driven self‐actuator for flap opening by constructing a bilayer consisting of a hygroscopic layer using polyethylene glycol and cellulose acetate, and a hydrophobic polymer using a polyester type polymer, is used and successfully demonstrated an essentially instant 4 °C apparent temperature cooling performance within one minute of sweat–humidity‐initiated actuation while wearing TAT using a sweating skin simulated device.

Kim, Gunwoo↗