Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Low leakage current in heteroepitaxial Al 0.7 Sc 0.3 N ferroelectric films on Ga N

Wurtzite ( Al , Sc ) N ferroelectrics are attractive for microelectronics applications due to their chemical and structural compatibility with wurtzite semiconductors, such as Ga N and ( Al , Ga ) N . However, the leakage current in epitaxial stacks reported to date should be reduced for reliable device operation. Here, we demonstrate low leakage current in epitaxial Al 0.7 Sc 0.3 N films on Ga N with well-saturated ferroelectric hysteresis loops that are orders of magnitude lower (i.e., 0.07 A cm − 2 ) than previously reported films (1–19 A cm − 2 ) having similar or better structural characteristics. We also show that, for these high-quality epitaxial ( Al , Sc ) N films, structural quality (edge and screw dislocations), as measured by diffraction techniques, is not the dominant contributor to leakage. Instead, the small leakage in our films is limited by thermionic emission across the interfaces, which is distinct from the large leakage due to trap-mediated bulk transport in the previously reported ( Al , Sc ) N films. To support this conclusion, we show that Al 0.7 Sc 0.3 N on lattice-matched In 0.18 Ga 0.82 N buffers with improved structural characteristics but higher interface roughness exhibit increased leakage characteristics. This demonstration of low leakage current in heteroepitaxial ( Al , Sc ) N films and understanding of the importance of interface barrier and surface roughness can guide further efforts toward improving the reliability of wurtzite ferroelectric devices. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

Leakage detection using smart field technology

Various examples are provided for gas leakage detection from geologic storage sites. In one example, a system for detection of gas leakage from a geologic storage site includes permanent down-hole gauges (PDGs) disposed at different depths within a well and an evaluation system that can determine a three-dimensional (3D) location of the gas leakage from the geologic storage site and a leakage indicator. The 3D location and leakage indicator can be determined using pressure data provided by the PDGs. The geologic storage site can store, e.g., CO2, natural gas or other type of gas. In another example, a method for detecting gas leakage from a geologic storage site includes receiving pressure data provided by PDGs disposed within one or more wells associated with the geologic storage site, determining key performance indicators using the pressure data and determining a 3D location and a leakage indicator using the key performance indicators.

47 OTHER INSTRUMENTATION↗

LEAKAGE CHARACTERISTICS OF A STEPPED BALANCE PISTON LABYRINTH SEAL IN SUPERCRITICAL CO2

In an integrally geared compressor, there is a net thrust load on the pinion shaft from gear loads and aerodynamic forces. The net thrust on the pinion is resolved with either a thrust bearing or a thrust collar (rider ring). As the pressure increases, this increases the aerodynamic force proportionally. In highpressure systems this can overwhelm the thrust bearing or thrust collar if thrust is mismanaged. In a recent test program for an sCO2 integrally geared compander (compressor/turbine), a balance piston was created on the opposite end of the turbine to provide an equalizing thrust; while this is not novel, the balance piston provided a test apparatus for measuring the leakage on a 20 tooth stepped labyrinth seal operating at pressures in excess of 250 bar (3600 psi). The stepped balance piston seal is a 20 tooth tooth-onrotor balance piston seal. This type of seal was selected since it was predicted to have substantially less leakage than a comparably sized straight through labyrinth seal. Comparisons between the two designs will be made, showing that the leakage of the stepped balance piston seal is considerably lower. The tooth clearance on the seal was selected to be 30 mils radial. While this seems large, a stack-up tolerance assessment showed that this magnitude of clearance was appropriate to prevent rotor stator contact. During the testing campaign, data was recorded showing the leakage across this stepped balance piston seal at pressures in excess of 250 bar (3600 psi) with a pressure ratio of 2. This leakage data was measured, and will be compared to leakage data predicted with CFD. Two measurement methods are presented for the stepped balance piston seal: an orifice plate and valve. The predicted seal leakage from a straight through seal was four times that of the predicted stepped labyrinth seal. The measured flow from the stepped seal was on the same order as the CFD prediction and offered adequate rotordynamic performance

wilkes, jason↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RAMM-TM for detection of gas leakage from canisters containing spent nuclear fuel

Remote Area Modular Monitoring (RAMM) for canister surface temperature measurement (TM), or RAMM-TM, is a novel remote monitoring device for detection of gas leakage based on surface temperature measurements of canisters containing spent nuclear fuel. Here we describe the development of RAMM-TM, as is the demonstration of its performance in detecting canister gas leakage from a small, simulated chloride-induced stress corrosion crack in experiments using a 1/4.5-scale model cask. Both helium and air gas leakage from a canister were detected within hours after the start of the leakage. The change in surface temperatures at the top and bottom of the canister (ΔTBT) during gas leakage (depressurization) triggered automatic alarms, providing a sound basis for early detection of gas leakage from the canister. This methodology would allow consequence management through the implementation of mitigatory actions to continue effective aging management and to reduce risks to public safety, health, and the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid model to evaluate the frequency-dependent leakage inductance of partially-filled transformers

The leakage inductance of a transformer designed for a power electronic converter can drop significantly as the switching frequency is increased due to skin and proximity effects. Although the magnetic image method-based double-2-D model can predict the low-frequency leakage inductance of a partially-filled transformer with sufficient accuracy, it is inherently a frequency-independent model. While Dowell’s 1-D model uses frequency-dependent relations to account for both skin and proximity effects, its accuracy is severely affected by the assumed winding geometry. In this paper, a semianalytical hybrid model is proposed that uses superposition to combine a modified Dowell’s model with the double-2-D model to predict the true leakage inductance of partially-filled transformers at any given frequency. All three conductor types—round, foil, and litz wire—are modeled and analyzed. The quasi-2-D model is further investigated on a variable inductance transformer (VIT) whose winding geometry can be modified mechanically to vary its leakage inductance. With less than 5 % error throughout, the semi-analytically evaluated leakage inductances are in excellent agreement with the finite element method (FEM) simulated and experimentally measured leakage inductances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Node Monitoring as a Fault Detection Countermeasure against Information Leakage within a RISC-V Microprocessor

Advanced, superscalar microprocessors (μP) are highly susceptible to wear-out failures because of their highly complex, densely packed circuit structure and extreme operational frequencies. Although many types of fault detection and mitigation strategies have been proposed, none have addressed the specific problem of detecting faults that lead to information leakage events on I/O channels of the μP. Information leakage can be defined very generally as any type of output that the executing program did not intend to produce. In this work, we restrict this definition to output that represents a security concern, and in particular, to the leakage of plaintext or encryption keys, and propose a counter-based countermeasure to detect faults that cause this type of leakage event. Fault injection (FI) experiments are carried out on two RISC-V microprocessors emulated as soft cores on a Xilinx multi-processor System-on-chip (MPSoC) FPGA. The μP designs are instrumented with a set of counters that records the number of transitions that occur on internal nodes. The transition counts are collected from all internal nodes under both fault-free and faulty conditions, and are analyzed to determine which counters provide the highest fault coverage and lowest latency for detecting leakage faults. We show that complete coverage of all leakage faults is possible using only a single counter strategically placed within the branch compare logic of the μPs.

42 ENGINEERING↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

NRAP Recommended Practices for Containment Assurance and Leakage Risk Quantification

This report presents recommendations for quantitatively assessing and managing leakage risk and effective containment assurance at geologic carbon storage (GCS) sites, amidst uncertainty in site characteristics and performance. These recommended practices are a product of the U.S. Department of Energy’s (DOE) Office of Fossil Energy and Carbon Management’s National Risk Assessment Partnership (NRAP)—a multi-year collaborative research effort of Lawrence Berkeley National Laboratory, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, National Energy Technology Laboratory, and Pacific Northwest National Laboratory. These recommended practices are organized as a set of conceptual workflows that correspond with the stages of the GCS project lifecycle. They consider aspects of site characterization, quantification of potential leakage, assessing the spatial extent of potential environmental impacts, optimizing monitoring design for detection of potential leakage, evaluation of concordance between monitored and forecasted reservoir response, assessing conformance with expected/accepted performance, and determination of the timeline over which risk of impactful leakage can be expected to abate. These conceptual workflows are intended to aid stakeholders in making risk management decisions at GCS sites and to support development of sound, risk-based justifications for characterizing the subsurface, defining area of potential leakage impact, designing site monitoring plans, selecting leakage risk management/mitigation alternatives, and estimating site closure timelines.

54 ENVIRONMENTAL SCIENCES↗

Testing Rod Seal Leakage of a 700 HP Reciprocating Compressor

Methane emissions from reciprocating compressors in the U.S. natural gas industry account for over 72.4 Bcf per year according to a 2006 statement by the United States Environmental Protection Agency. Methane also has a global warming potential 50 times greater than carbon monoxide. Reciprocating compressors are the machinery type with the highest contribution to methane emissions at natural gas transmissions stations. The largest contributing factor comes from the sealing components in the packing components around the piston rod. SwRI, therefore, designed and setup a test loop to perform baseline packing leakage measurements on a four stage 700 HP JGT/4 compressor. The goal was to improve upon current packing leakage models and to compare new seals vs. used seals. The test loop design is described including the limits of operation. The Data Acquisition System (DAQ), including data measurements, is also fully described. The project shows the results of the commissioning process that verified the operation of all the components. Once the loop was commissioned, SwRI performed baseline packing leakage for multiple pressure ratios on each of the four stages of the compressor. The data was collected to develop an analytical model of the packing leakage. Finally, similar testing was performed after replacing the typical rod seal packing with used packing. The used packing leakage was compared to the baseline packing leakage.

03 NATURAL GAS↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Toward extreme high-temperature supercritical CO 2 power cycles: Leakage characterization of ceramic 3D-printed heat exchangers

We report future supercritical carbon dioxide (sCO 2 ) Brayton power cycles demand high-performance gas-to-gas heat exchangers (HXs) operating under extreme temperature and pressure conditions at which most existing superalloy materials fail to function safely. Ceramic HXs are deemed excellent candidates for advanced sCO 2 power plants as they can withstand high-temperature working environments. Particularly, ceramic 3D printing enables compact HX topologies employing complex and efficient heat transfer features. However, ceramic 3D-printed walls separating hot and cold flow streams are susceptible to a through-plane leakage inherent to a powder-based manufacturing process, including ceramic 3D printing. A potential leakage through ceramic separating walls poses a significant challenge in developing reliable ceramic 3D-printed HXs and could deteriorate thermal performance. In this study, various parameters, including feedstock slurry, 3D-printing direction, and post-processing conditions, are considered, for the first time, to characterize the argon gas leakage rate associated with alumina 3D-printed parts. Three 3D-printed ceramic structures of flat plates, curved tubes, and small-scale plate-and-frame HXs with various thicknesses are systematically studied to determine powder and ceramic 3D-printing conditions to eliminate the through-plane leakage. The results showed that an alumina 3D-printed plate with a thickness of 0.75 mm demonstrates a permeability of 6 x 10 -4 milli-darcy. An alumina 3D-printed tube with a wall thickness of 0.9 mm revealed a permeability of 9.6 x 10 -7 milli-darcy. Furthermore, leakage test results of functional 3D-printed modules showed a dependency on the 3D-printing direction. Particularly, alumina cell-scale HXs employing 1.5-mm-thick horizontal and vertical 3D-printed separating walls demonstrated impermeability and gas permeability of 7.2 x 10 -5 millidarcy, respectively. Insights gained from the present study facilitate the development of complex ceramic 3D-printed HXs and other balance of plant components for next-generation high-temperature high-pressure sCO 2 power cycles.

36 MATERIALS SCIENCE↗

Using temperature and flow fields to detect gas leakage from canisters containing spent nuclear fuel: Applications to RAMM-TM

The multi-physics STAR-CCM+ code has been used to simulate the temperature and flow fields in canister gas leakage experiments conducted by using a 1/4.5-scale model storage cask. The simulations were conducted at Argonne National Laboratory’s Laboratory Computing Resource Center, utilizing high-performance computing resources. Development of STAR-CCM+ simulation models for the 1/4.5-scale model cask is described herein, followed by validation of the simulation results against experimental data. Canister depressurization and thermal response during gas leakage are discussed, along with analyses of the leakage path and allowable leakage rate. The insights gained from the STAR-CCM+ simulations and leakage analyses will help guide future experiments and actual industry applications of Argonne’s Remote Area Modular Monitoring system for canister surface temperature measurement (RAMM-TM) to enable effective aging management of spent fuel during extended dry storage, as well as help reduce risks to public safety and health and protect the environment.

Canister gas leakage↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Quantifying the Potential Atmospheric Leakage Risks Associated With the Geologic Storage of CO 2 in Saline Aquifers for Use in Voluntary Carbon Market Buffer Account Determination

Conference paper presented at 17th International Conference on Greenhouse Gas Control Technologies (GHGT-17), Calgary, Alberta, Canada, October 20–24, 2024. This paper presents the results of a detailed study into the potential atmospheric leakage risks associated with the geologic storage of CO 2 in saline aquifers. This study included a detailed literature review, a re-creation of existing CO 2 leakage models put forth by other authors and, lastly, the development of an enhanced model that can be utilized for assessing the potential losses to the atmosphere of stored CO 2 across a variety of potential project parameters. The results of this study indicate that, across broad ranges of input parameters for mechanisms that have the potential for CO 2 loss from the storage complex to the atmosphere, there is an extremely low risk of CO 2 leakage to the atmosphere, with the median leakage risk estimated to be 0.1% of total injected CO 2 . The risk of leakage from real-world storage projects is likely to be even lower than those estimated through this study.

01 COAL, LIGNITE, AND PEAT↗

Milestone Report for MS8: Extend Quantitative Brine and CO 2 Leakage Calculations

This report summarizes results of the risk analysis and characterization of CO 2 and brine leakage potential of Farnsworth Unit (FWU) wells. U.S. DOE’s National Risk Assessment Partnership (NRAP) program works on quantitatively assess long-term environmental risks amidst significant geologic uncertainty and variability. NRAP risk assessment and computational tools are developed to quantify uncertainties and calculate risk associated with geologic sequestration of carbon dioxide (CO 2 ). For this study, we have developed a workflow from University of Utah’s physics-based reservoir simulators to performing leakage calculations using NRAP Tools. NRAP tools (NRAP-IAM-CS, RROM-Gen) are used to conduct leakage risk analysis based on Eclipse simulation results, and characterize wellbore leakage at the Farnworth Site. This report summarizes results of the risk analysis and characterization of CO 2 and brine leakage potential of Farnsworth Unit (FWU) wells.

54 ENVIRONMENTAL SCIENCES↗