Propellant leakage detection systems quarterly progress report, 1 sep. - 30 nov. 1967
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
16th International Conference on Greenhouse Gas Technologies (GHGT-16), Lyon, France, October 23-27, 2022
Abnormal combustion excites characteristic standing wave. Acoustical leak-detection system gives early warning of failure, enabling operating personnel to stop combustion process and repair spray bar before leak grows large enough to cause damage. Applicable to engines, gas turbines, furnaces, and other machines in which acoustic emissions at known frequencies signify onset of damage. Bearings in rotating machines monitored for emergence of characteristic frequencies shown in previous tests associated with incipient failure. Also possible to monitor for signs of trouble at multiple frequencies by feeding output of transducer simultaneously to multiple band-pass filters and associated circuitry, including separate trigger circuit set to appropriate level for each frequency.
This report provides a detailed description of a set of numerical simulations that represent reservoir behavior over time in response to different operational decision scenarios for detection of potential leakage and reduction or avoidance of leakage impact at a hypothetical geological carbon storage (GCS) site. These simulations serve as the basis for a series of GCS leakage risk forecasts that are to be developed using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), and a demonstration of a simple decision support workflow for evaluation of mitigation strategies based on results of those system model forecasts. This risk assessment and decision support study is forthcoming. Four injection scenarios were considered: a constant rate carbon dioxide (CO 2 ) injection case (base case), a case with CO 2 injection rate adjustment, a case with early termination of injection operations, and a case with brine extraction. CO 2 injection operations were controlled to ensure that the pressure transient remains below the defined manageable reservoir fracture pressure, with consideration shown to hypothetical locations within the modeled spatial domain where the overburden was weaker and lower transient pressure increases were allowable. Additionally, a brine extraction alternative was considered as a reservoir management and risk mitigation option to reduce reservoir pressure, steer the plume away from any hypothetical geohazard such as fault as needed, and enhance storage capacity. Such operational actions contribute to risk management overtime. This study explores the potential utility of reservoir management for risk reduction at GCS sites. This study shows that the injection design may modify the time to CO 2 breakthrough at a legacy well; in particular, these results show that brine extraction can add value for mitigating risk both by delaying leakage and reducing pressure build-up. For the scenario considered, both pressure plots and pressure distributions demonstrate that pressure build-up was decreased by 3% with brine extraction. Additionally, extraction of brine afforded enhancement of CO 2 storage capacity by 5% compared to the base case. These findings suggest that brine extraction has substantial potential to steer the risk-related reservoir effects away from known geohazards (e.g., faults and legacy wells) by conducting pressure transient effects and CO 2 plume movement toward the production well. Injection rate adjustment scenarios considered in this study show potential value for managing both reservoir pressure transients and CO 2 plume behavior. Operational actions for reducing injection and/or early termination of injection (as compared to the base case), however, require careful design; tailoring both the extent and timing of injection rate adjustment over the injection and post-injection operational period must be thoroughly planned to balance maximizing storage and minimizing subsurface environmental risk. The study also gives preliminary consideration to the effectiveness that monitoring strategy may play in providing useful information to inform reservoir management decisions for risk reduction. Two types of monitoring were considered: 1) pressure build-up or pressure transient; and 2) potential leakage detection from a CO 2 mass or plume. Four hypothetical legacy wells, two plugged and two abandoned, were placed in the model domain. Monitoring along these wells was measured over time in individual stacked reservoir formations and shale formations to support risk mitigation decisions, especially operational decisions that assisted in risk reduction. These simulations will serve as the basis for a series of GCS leakage risk forecasts that are to be developed using NRAP’s Open-IAM, and demonstration of a simple decision support workflow for comparative assessment of mitigation alternatives based on results of those system model forecasts. This risk assessment and decision support study is forthcoming.
Recent evaluations of counter-based periodic testing strategies for fault detection in Microprocessor (μP) have shown that only a small set of counters is needed to provide complete coverage of severe faults. Severe faults are defined as faults that leak sensitive information, e.g., an encryption key on the output of a serial port. Alternatively, fault detection can be accomplished by executing instructions that periodically test the control and functional units of the μP. In this paper, we propose a fault detection method that utilizes an ’engineered’ executable program combined with a small set of strategically placed counters in pursuit of a hardware Periodic Built-In-Self-Test (PBIST). We analyze two distinct methods for generating such a binary; the first uses an Automatic Test Generation Pattern (ATPG)-based methodology, and the second uses a process whereby existing counter-based node-monitoring infrastructure is utilized. We show that complete fault coverage of all leakage faults is possible using relatively small binaries with low latency to fault detection and by utilizing only a few strategically placed counters in the μP.
Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.
The multi-physics STAR-CCM+ code has been used to simulate the temperature and flow fields in canister gas leakage experiments conducted by using a 1/4.5-scale model storage cask. The simulations were conducted at Argonne National Laboratory’s Laboratory Computing Resource Center, utilizing high-performance computing resources. Development of STAR-CCM+ simulation models for the 1/4.5-scale model cask is described herein, followed by validation of the simulation results against experimental data. Canister depressurization and thermal response during gas leakage are discussed, along with analyses of the leakage path and allowable leakage rate. The insights gained from the STAR-CCM+ simulations and leakage analyses will help guide future experiments and actual industry applications of Argonne’s Remote Area Modular Monitoring system for canister surface temperature measurement (RAMM-TM) to enable effective aging management of spent fuel during extended dry storage, as well as help reduce risks to public safety and health and protect the environment.
Kimberlina 1.2 Velocity model and synthetic seismic data, produced in collaboration of teams at the National Energy Technology Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory through the National Risk Assessment Partnership. Data is associated with the following publication: Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019. The Kimberlina 1.2 Velocity models were produced by Zan Wang, Robert Dilmore, William Harbert, and Lianjie Huang at NETL. The following citations are directly related to the creation of the velocity models: Wang, Z. Harbert, W., Dilmore, R., Huang, L. Modeling of time-lapse seismic monitoring using CO2 leakage simulations for a model CO2 storage site with realistic geology: Application in assessment of early leak-detection capabilities. International Journal of Greenhouse Gas Control. V. 76, September 2018, Pages 39-52. https://doi.org/10.1016/j.ijggc.2018.06.011 Wang, Z., Dilmore, R., Harbert, W. Inferring CO2 saturation from synthetic surface seismic and downhole monitoring data using machine learning for leakage detection at CO2 sequestration sites. International Journal of Greenhouse Gas Control, V. 100, September 2020. https://doi.org/10.1016/j.ijggc.2020.103115 The velocity models were built based on the Kimberlina 1.2 aquifer impact data which is associated with the following publications: Buscheck, T.A., Mansoor, K., Yang, X., Wainwright, H., and Carroll, S. (2019). Downhole pressure and chemical monitoring for CO2 and brine leak detection in aquifers above a CO2 storage reservoir. International Journal of Greenhouse Gas Control. 91. 102812. 10.1016/j.ijggc.2019.102812. Xianjin Yang, Thomas A. Buscheck, Kayyum Mansoor, Zan Wang, Kai Gao, Lianjie Huang, Delphine Appriou, Susan A. Carroll, Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, Volume 90, 2019, 102803, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2019.102803 The synthetic seismic data was produced by Youzuo Lin and team at LANL, and are associated with the following citations: Jordan, P. D., and J. L. Wagoner. Characterizing Construction of Existing Wells to a CO2 Storage Target: The Kimberlina Site, California. Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019.
Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.
Underground hydrogen storage (UHS) plays a key role in the energy landscape. However, like other subsurface engineering technologies, UHS may cause leakage into the groundwater or atmosphere and possibly induce local seismicity. To reduce these risks, seismic monitoring could be a viable technique to track the UHS plume, detect leakages, and locate induced seismicity events. Seismic monitoring has been proposed to safely monitor UHS, but research in this area is still new and requires field studies. Lab and theoretical studies have demonstrated the validity of seismic monitoring for UHS. Therefore, it is imperative to analyze the economic feasibility of seismic monitoring for UHS. Hence, we develop a cost model and open-source Python code for seismic monitoring that considers types of seismometers, comprehensive operational scenarios, detection thresholds, and long-term leakage monitoring. A case study is further provided to validate the cost model on reservoir simulations of UHS. We find that the levelized cost for a 10-year operating UHS site will range on the order of ∼0.003 $\$$/kg. The methods developed in this study could also be applied to the monitoring of groundwater, gas, and/or wastewater injection.
Remote Area Modular Monitoring (RAMM) for canister surface temperature measurement (TM), or RAMM-TM, is a novel remote monitoring device for detection of gas leakage based on surface temperature measurements of canisters containing spent nuclear fuel. Here we describe the development of RAMM-TM, as is the demonstration of its performance in detecting canister gas leakage from a small, simulated chloride-induced stress corrosion crack in experiments using a 1/4.5-scale model cask. Both helium and air gas leakage from a canister were detected within hours after the start of the leakage. The change in surface temperatures at the top and bottom of the canister (ΔTBT) during gas leakage (depressurization) triggered automatic alarms, providing a sound basis for early detection of gas leakage from the canister. This methodology would allow consequence management through the implementation of mitigatory actions to continue effective aging management and to reduce risks to public safety, health, and the environment.
Chloride-induced stress corrosion cracking (CISCC) of canisters has been identified as a potential degradation mechanism requiring ageing management — especially in a marine air environment. Methods for monitoring helium gas leakage from canisters have been developed on the basis of a phenomenon that the bottom temperature of the canister increases as the top temperature of the canister decreases when helium gas leaks during storage. In this paper, we consider the radiological consequences of CISCC based on two scenarios of helium gas leakage and propose effective management that includes a timeline for monitoring and mitigation. Monitoring helium gas leakage by measuring the difference in temperature between canister surfaces in the dry cask storage of spent fuel (SF) can detect leakage before SF undergoes oxidation as a result of air ingress and before country-specific regulatory limits of off-site doses are exceeded, thereby enabling mitigatory action.
It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.
A method that can be implemented with relatively simple electronic circuitry provides a capability for detecting leakage of an electrically conductive liquid from an electrically nonconductive underground pipe. Alternatively or in addition, the method can be applied to locate the pipe, whether or not there is a leak. Although the method is subject to limitations (some of which are described below), it is still attractive as an additional option for detecting leaks and locating pipes without need for extensive digging. The method is based on capacitive coupling of an alternating electrical signal from the liquid to a portable electronic unit that resembles a metal detector. A signal voltage is applied to the liquid at some convenient point along the pipe: for example, the signal could be coupled into the liquid via an aboveground metal pipe fitting, the interior surface of which is in contact with the liquid. The signal is conducted through the liquid in the pipe; in the case of diffusive leak of liquid into the surrounding ground, the signal is conducted through the leak, into the portion of the adjacent ground that has become soaked with the liquid. (A drip leak cannot be detected by this method because there is no conductive path between the liquid inside and the liquid outside the pipe.) The portable unit includes an electrically conductive plate connected to the input terminal of an amplifier. When the plate is brought near the pipe or the leaked liquid, a small portion of the signal power is coupled capacitively from the liquid to the plate. The user scans the plate near the ground surface to find the locus of maximum signal strength. The leak can be identified as a relatively wide area, contiguous with the location of the pipe, over which the signal is detectable.
Atom-loss errors are a major limitation of current state-of-the-art neutral-atom quantum computers and pose a significant challenge for scalable systems. In a quantum processor with cesium atoms, we demonstrate proof-of-principle circuit-based conversion of this form of leakage error to erasure errors via leakage-detection units (LDUs), which nondestructively map information about the presence or absence of the qubit onto the state of an ancilla. We benchmark the performance of the LDU using a three-outcome low-loss state-detection method and find that the LDU detects atom-loss errors with approximately 93.4% accuracy, limited by technical imperfections of our apparatus. We further compile and execute a SWAP LDU, wherein the roles of the original data atom and ancilla atom are exchanged under the action of the LDU, providing “free refilling” of atoms in the case of atom loss. This circuit-based leakage-to-erasure error conversion is a critical component of a neutral-atom quantum processor where the quantum information may significantly outlive the lifetime of any individual atom in the quantum register. Finally, we demonstrate that LDUs may also be used to handle other forms of leakage errors where population moves to states outside of the computational subspace.
This report details the digitization of a legacy wellbore database, including data processing assumptions, parameter estimation, and risk assessment methodology. The database, comprising 6,454 documents, was provided by ISGS. It includes valuable data from the Prairie State Generating Company (PSGC) and One Earth Energy (OEE) sites of the CarbonSAFE Phase III – Illinois Storage Corridor project. The report focuses on wells within a 15-mile radius from the Lively Grove #1 (LG#1) well at PSGC site, evaluating subsurface conditions and potential risks. A total of 4,386 wellbores within 15 miles of the LG#1 well were filtered based on depth and formation codes. LG#1 is the stratigraphic well at the PSGC site drilled in 2021. Ninety-four (94) wells penetrating the Maquoketa Shale Group (the primary confining unit) within the estimated area-of-review (AoR) for the PSGC site were evaluated using a qualitative risk assessment (QRA) methodology. The QRA developed by Arbad et al. 2022 focuses on legacy wells within the AoR and categorizes them based on well construction details. The QRA identifies wells that need immediate attention by categorizing them based on penetration depth and protection. Wells within the AoR were categorized into nine groups based on penetrations and protections. These categories range from Type 1 wells, with no documentation, to Type 9 wells, which do not penetrate the primary confining unit or storage reservoir (unit). Well accessibility within the AoR varies based on well status, including Dry & Abandoned (DA), Plugged & Abandoned (PA), Injection (INJ), Oil/Gas Producing (PROD), and Observation (Obs) wells. Accessibility levels were determined by well construction, with DA wells being the least accessible and Observation wells the most accessible, impacting gas leakage detection possibilities. Remedial action priority of wells decreases from Type 1 to Type 9 wells. Type 1 to Type 6 wells with status DA and PA require immediate attention, while Type 7 and Type 8 wells are low priority. A risk matrix used to prioritize corrective actions for legacy wells is proposed to categorize wells within an AoR based on penetrations, protections, and accessibility. The methodology involves data acquisition, well categorization into nine types, and determining CO 2 leakage pathways using well schematics and geospatial mapping. This approach is particularly useful for managing the integrity of legacy wells throughout the lifecycle of a Carbon Capture and Storage (CCS) project. A qualitative risk assessment of 94 wells within the AoR of the PSGC site identified 54 wells with high priority for corrective action due to penetration of the primary containment seal. The assessment utilizes color-coded maps to categorize well types and prioritize corrective actions, providing a comprehensive analysis. Schematics of wells penetrating the primary confining unit were drawn, and leakage pathways were identified. Details of all wells penetrating the confining zone are provided in the appendix, including information on well types, plugging, and casing status.
Recent advances in artificial intelligence (AI), enhanced computational capabilities, and innovations in sensors and hardware have driven the increasing development and application of robots in heating, ventilation, and air conditioning (HVAC) systems. We selected and reviewed 101 studies published between 2005 and 2025, sourced from IEEE Xplore, Scopus, Web of Science, and the ACM Digital Library. To analyze these works, we developed a five-dimensional analytical framework (morphology, sensing, navigation, task execution, and system integration), inspired by the Springer Handbook of Robotics and tailored specifically for robotic applications in HVAC. Based on the reviewed studies, six distinct tasks spanning the entire HVAC lifecycle have been identified. Among the six tasks, inspection and maintenance dominate (59 %), followed by indoor monitoring and auditing (21 %), whereas leakage detection, comfort support, and installation/retrofit remain less explored. To address the identified gaps, this review proposes future research directions including investigating robot-aware HVAC design principles, developing multimodal HVAC sensing and data fusion techniques, enhancing robot training and hardware capabilities, and expanding robotic applications beyond Maintenance and Operations (M&O). The findings from this review inform future robotics research for HVAC applications and ultimately enhance system affordability, energy efficiency, resilience or reliability, and occupant environmental comfort. Moreover, it seeks to inspire researchers to explore the intersections of robotics, computer science, building science, and HVAC engineering fostering advancements in this multidisciplinary field.