Alternatives to Silicon Rubber Thermal Barrier in RSRM Nozzle Joints

Thiokol Propulsion encountered a situation where gas path can form in the Filler material in joints between the phenolic in the Space Shuttle Reusable Solid Rocket Motor nozzle. An investigation determined that the method for injecting the filler material into the joint created a pressurized pocket of air that forced its way to the surface while the filler was curing. The path that the air took remained open some situations leaving a path for hot gas to get deep into the joint. The condition that created the gas path has been corrected by modifications to the manufacturing process, but a design solution that would reduce processing time is being pursued. A strip of open cell installed deep into the joint, can serve as a barrier to the Filler material. Testing indicates that the foam eliminates the pressure pocket, and does not prevent detection of leakage of the o-ring seals during leak test. Open cell foam does not have thermal resistance capability and mechanical structure, which would be required in the event of a gas path. A replacement to open cell foam is now being considered. Braided carbon fiber rope has the permeability characteristics of foam and it has thermal resistance characteristics as well. Braided carbon fiber rope (BCFR) has been tested in simulated joints in subscale rocket motor. Results of the testing indicate that braided carbon fiber rope can significantly reduce gas temperature by as much es 3000 F in a nozzle joint configuration. BCFR can be installed as a barrier to stop the joint filler material or it can used as the thermal barrier alone.

Totman, Peter D.↗

Leak Detector

Ni-Tec unit is a modified version of the Lixiscope, a small, battery-powered, portable X-ray instrument. Unit is used as a portable device capable of detecting radioactive leakage. If there were a leak, the radioactivity would illuminate the units viewing screen and identify the source of the leak; in the absence of radioactivity the screen shows nothing.

Source record↗

CEV OME/RCS Flow Health Monitor: Status Review

I. Primary purpose: detect propellant valve leakage: a) Reduce launch propellant mass by reducing leakage loss . margins, b) Improve safety by reducing risk of propellant ice build up in thruster. II. Secondary objectives: a) Wetness sensor to detect that lines have been flooded. b) Monitor engine performance (timing, mix ratio). c) Use in GSE as valve leakage monitor.

Youngquist, Robert↗

Optical Detection Of Cryogenic Leaks

Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

Wyett, Lynn M.↗

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.↗

Power monitoring in space nuclear reactors using silicon carbide radiation detectors

Space reactor power monitors based on silicon carbide (SiC) semiconductor neutron detectors are proposed. Detection of fast leakage neutrons using SiC detectors in ex-core locations could be used to determine reactor power: Neutron fluxes, gamma-ray dose rates and ambient temperatures have been calculated as a function of distance from the reactor core, and the feasibility of power monitoring with SiC detectors has been evaluated at several ex-core locations. Arrays of SiC diodes can be configured to provide the required count rates to monitor reactor power from startup to full power Due to their resistance to temperature and the effects of neutron and gamma-ray exposure, SiC detectors can be expected to provide power monitoring information for the fill mission of a space reactor.

silicon carbide detectors↗

Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

Hammock, William R., Jr.↗

Forest Carbon Emissions from Cropland Expansion in the Brazilian Cerrado Biome

Land use, land use change, and forestry accounted for two-thirds of Brazil's greenhouse gas emissions profile in 2005. Amazon deforestation has declined by more than 80% over the past decade, yet Brazil's forests extend beyond the Amazon biome. Rapid expansion of cropland in the neighboring Cerrado biome has the potential to undermine climate mitigation efforts if emissions from dry forest and woodland conversion negate some of the benefits of avoided Amazon deforestation. Here, we used satellite data on cropland expansion, forest cover, and vegetation carbon stocks to estimate annual gross forest carbon emissions from cropland expansion in the Cerrado biome. Nearly half of the Cerrado met Brazil's definition of forest cover in 2000 (greater than or equal to 0.5 ha with greater than or equal to 10% canopy cover). In areas of established crop production, conversion of both forest and non-forest Cerrado formations for cropland declined during 2003-2013. However, forest carbon emissions from cropland expansion increased over the past decade in Matopiba, a new frontier of agricultural production that includes portions of Maranhao, Tocantins, Piau­, and Bahia states. Gross carbon emissions from cropland expansion in the Cerrado averaged 16.28 Tg C yr (exp -1) between 2003 and 2013, with forest-to-cropland conversion accounting for 29% of emissions. The fraction of forest carbon emissions from Matopiba was much higher; between 2010-2013, large-scale cropland conversion in Matopiba contributed 45% of total Cerrado forest carbon emissions. Carbon emissions from Cerrado-tocropland transitions offset 5-7% of the avoided emissions from reduced Amazon deforestation rates during 2011-2013. Comprehensive national estimates of forest carbon fluxes, including all biomes, are critical to detect cross-biome leakage within countries and achieve climate mitigation targets to reduce emissions from land use, land use change, and forestry.

remote sensing↗

Gas leak-detection system

Data monitoring of gas leakage in satellites and spacecraft is facilitated by adding gaseous radioisotopes to cold compressed gas and mounting a detector in the thrust nozzle.

Roselli-Lorenzini, F. G.↗

Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit

We report an integrated CMOS microluminometer optimized for the detection of low-level bioluminescence as part of the bioluminescent bioreporter integrated circuit (BBIC). This microluminometer improves on previous devices through careful management of the sub-femtoampere currents, both signal and leakage, that flow in the front-end processing circuitry. In particular, the photodiode is operated with a reverse bias of only a few mV, requiring special attention to the reset circuitry of the current-to-frequency converter (CFC) that forms the front-end circuit. We report a sub-femtoampere leakage current and a minimum detectable signal (MDS) of 0.15 fA (1510 s integration time) using a room temperature 1.47 mm2 CMOS photodiode. This microluminometer can detect luminescence from as few as 5000 fully induced Pseudomonas fluorescens 5RL bacterial cells. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Propellant Feed System Leak Detection: Lessons Learned From the Linear Aerospike SR-71 Experiment (LASRE)

This paper presents pertinent results and assessment of propellant feed system leak detection as applied to the Linear Aerospike SR-71 Experiment (LASRE) program flown at the NASA Dryden Flight Research Center, Edwards, California. The LASRE was a flight test of an aerospike rocket engine using liquid oxygen and high-pressure gaseous hydrogen as propellants. The flight safety of the crew and the experiment demanded proven technologies and techniques that could detect leaks and assess the integrity of hazardous propellant feed systems. Point source detection and systematic detection were used. Point source detection was adequate for catching gross leakage from components of the propellant feed systems, but insufficient for clearing LASRE to levels of acceptability. Systematic detection, which used high-resolution instrumentation to evaluate the health of the system within a closed volume, provided a better means for assessing leak hazards. Oxygen sensors detected a leak rate of approximately 0.04 cubic inches per second of liquid oxygen. Pressure sensor data revealed speculated cryogenic boiloff through the fittings of the oxygen system, but location of the source(s) was indeterminable. Ultimately, LASRE was cancelled because leak detection techniques were unable to verify that oxygen levels could be maintained below flammability limits.

Hass, Neal↗

Fluid leakage detector for vacuum applications

A leak detection system for use with a fluid conducting system in a vacuum environment, such as space, is described. The system preferably includes a mesh-like member substantially disposed about the fluid conducting system, and at least one sensor disposed within the mesh-like member. The sensor is capable of detecting a decrease in temperature of the mesh-like member when a leak condition causes the fluid of the fluid conducting system to freeze when exposed to the vacuum environment. Additionally, a signal processor in preferably in communication with the sensor. The sensor transmits an electrical signal to the signal processor such that the signal processor is capable of indicating the location of the fluid leak in the fluid conducting system.

Farkas, Tibor↗

Detectability of Martian carbonates from orbit using thermal neutrons

Numerical simulations of Martian neutron leakage flux spectra are made in order to explore the detectability of magnesium and calcium carbonate deposits using neutron spectroscopic techniques from orbit. The primary signature of such deposits is found to be an enhanced thermal amplitude. Although this enhancement is weakened by: (1) partial burial beneath an aeolian regolith blanket; (2) admixture with regolith on a microscopic (centimeter) or macroscopic (tens of centimeters) scale; and (3) reduction in the areal size of the deposit, near-surface stratigraphies of carbonates hypothesized by some authors as possible on Mars are still detectable by simple neutron sensors from orbit. However, the large variations in the magnitude of the thermal neutron enhancements caused by different carbonate deposit configurations found in this study require a combined gamma ray and neutron analysis for their unique specification.

Feldman, W. C.↗

Two Air Quality Regimes in Total Column NO2 over the Gulf of Mexico in May 2019: Shipboard and Satellite Views

The Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf of Mexico was conducted in May 2019 by NASA and the Bureau of Ocean Energy Management to determine the feasibility of using satellite data to measure air quality in a region of concentrated oil and natural gas (ONG) operations. SCOAPE addressed both technological and scientific issues related to measuring NO2 columns over the Outer Continental Shelf. Featured were nitrogen dioxide (NO 2 ) instruments (Pandora, Teledyne API analyzer) at Cocodrie, LA (29.26°, -90.66°), and on the Research Vessel Point Sur operating off the Louisiana coast with measurements of ozone, carbon monoxide and volatile organic compounds (VOC). The findings: (1) All NO 2 observations revealed two atmospheric regimes over the Gulf, the first influenced by tropical air in 10-14 May, the second influenced by flow from urban areas on 15-17 May; (2) Comparisons of OMI v4 and TROPOMI v1.3 TC (total column) NO 2 data with shipboard Pandora NO 2 column observations averaged 13% agreement with the largest difference during 15-17 May (~20%). At Cocodrie, the satellite-Pandora agreement was ~5%. (3) Three new-model Pandora instruments displayed a TC NO 2 precision of 0.01 Dobson Units (~5%); (4) Regions of smaller, older natural gas operations showed high methane readings from leakage; elevated VOC were also detected. Neither satellite nor spectrometer captured the magnitude of ambient NO 2 variability near ONG platforms. Given an absence of regular air quality monitoring over the Gulf of Mexico, SCOAPE data constitute a baseline against which future observations can be compared.

Nitrogen dioxide↗

A Model-Based Thruster Leakage Monitor for the Cassini Spacecraft

The Cassini spacecraft was launched on October 15, 1997. It uses thrusters to perform many spacecraft control functions: to detumble the spacecraft, to maintain three-axis attitude control, to perform small trajectory correction burns, to desaturate the reaction wheels, and others.

Cassini↗

Microbial detection with low molecular weight RNA

The need to monitor microorganisms in the environment has increased interest in assays based on hybridization probes that target nucleic acids (e.g., rRNA). We report the development of liquid-phase assays for specific bacterial 5S rRNA sequences or similarly sized artificial RNAs (aRNAs) using molecular beacon technology. These beacons fluoresce only in the presence of specific target sequences, rendering as much as a 27-fold fluorescence enhancement. The assays can be used with both crude cell lysates and purified total RNA preparations. Minimal sample preparation (e.g., heating to promote leakage from cells) is sufficient to detect many Gram-negative bacteria. Using this approach it was possible to detect an aRNA-labeled Escherichia coli strain in the presence of a large background of an otherwise identical E. coli strain. Finally, by using a longer wavelength carboxytetramethylrhodamine beacon it was possible to reduce the fraction of the signal due to cellular autofluorescence to below 0.5%.

NASA Discipline Life Sciences Technologies↗