Search NASA⌕ Search

SEARCH · Search NASA

Results for “levelized cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data Analytics: Project-level Cost Estimates

Sandia National Laboratories is interested in understanding how data analytics can be applied to business problems, in particular financial management. This project examines how a combination of qualitative and analytical tools can be used to increase the accuracy of cost estimates at the project level. Although the initial scope of the project was to perform analyses on lab- or portfolio- level projections and forecasts, we examined project-level cost estimates for three reasons. First, qualitative and quantitative data were feasible to obtain within the 8-week project time frame. Second, we could develop a thorough enough understanding at this level to provide meaningful recommendations. Third, the results of our project would still be relevant despite undefined changes caused by the Financial Simplification. We performed external research on other companies in industry and on other national labs, internal research at Sandia, and data analysis using ARC and Excel. In total, we conducted twelve interviews, researched three other companies, and applied four analytical techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the levelized cost of energy in South Korea

This study evaluates the levelized cost of energy (LCOE) for various energy technologies in the Republic of Korea (Korea) from 2023 to 2050, highlighting cost trajectories and potential crossovers among competing technologies. The analysis projects that, based on our set of assumptions, utility-scale photovoltaic systems achieve lower LCOEs than nuclear by 2030, while fixed offshore wind is expected to become cost-competitive with coal-fired generation around the same time. Floating offshore wind is projected to reach cost parity with coal in the late 2030s. Co-firing with natural gas and green hydrogen is identified as the highest-cost generation option due to high natural gas and green fuel costs and declining capacity utilization. This study further examines the potential for hybrid systems that integrate renewable energy with energy storage to serve as flexible, cost-effective, zero-emission alternatives to green hydrogen-based generation. Spatial LCOE assessments indicate that near-shore offshore wind sites may achieve lower costs despite modest capacity factors, contingent on site-specific factors such as grid integration and social acceptance. The findings indicate that renewable energy technologies are expected to experience continued cost declines, with solar photovoltaic becoming the most competitive energy source in Korea by 2030–2035. Incorporating social costs accelerates this shift from conventional alternatives.

Green hydrogen↗

MHK Levelized Cost of Energy (LCOE) Guidance and Techno-Economic Analysis Materials

Useful information and tools for calculating the Levelized Cost of Energy (LCOE) and MHK Cost Breakdown Structure. Includes a structure for calculating the capital expenditures and operating costs of a marine energy technology or device, reference resource data for both wave and tidal, and LCOE reporting guidance. These tools are meant to be used to help calculate the Levelized Cost of Energy (LCOE) for an MHK or MRE technology or device.

16 TIDAL AND WAVE POWER↗

Levelized cost of energy (LCOE) metric to characterize solar absorber coatings for the CSP industry

The contribution of each component of a power generation plant to the levelized cost of energy (LCOE) can be estimated and used to increase the power output while reducing system operation and maintenance costs. The LCOE is used in order to quantify solar receiver coating influence on the LCOE of solar power towers. Two new parameters are introduced: the absolute levelized cost of coating (LCOC) and the LCOC efficiency. Depending on the material properties, aging, costs, and temperature, the absolute LCOC enables quantifying the cost-effectiveness of absorber coatings, as well as finding optimal operating conditions. The absolute LCOC is investigated for different hypothetic coatings and is demonstrated on Pyromark 2500 paint. Results show that absorber coatings yield lower LCOE values in most cases, even at significant costs. Optimal reapplication intervals range from one to five years. At receiver temperatures greater than 700 °C, non-selective coatings are not always worthwhile while durable selective coatings consistently reduce the LCOE—up to 12% of the value obtained for an uncoated receiver. Moreover the absolute LCOC is a powerful tool to characterize and compare different coatings, not only considering their initial efficiencies but also including their durability.

14 SOLAR ENERGY↗

Levelized Cost of Avoided CO2 tool (LCAC tool) v0.9

The levelized cost of avoided CO2 (LCAC) tool facilitates techno-economic calculations for various decarbonization technologies. It comprises two components to accomplish this: an input workbook based on MS Excel and a web-based output tool. The workbook acts as the input sheet, using the user-provided decarbonization measures and their impacts on lifetime energy consumption, energy costs, and CO2 emissions to compute LCAC (expressed in $/metric ton of avoided CO2). The workbook is uploaded to a web-based tool to generate an LCAC curve. This graphical representation illustrates the economic comparison of all decarbonization measures for purposes such as implementation prioritization. We are unaware of any publicly available tools with similar capabilities.

Ali Qamar, Muhammad↗

Comparative PV LCOE Calculator (Comparative Photovoltaic Levelized Cost of Energy Calculator) [SWR-20-86]

The calculator calculates levelized cost of energy (LCOE) for photovoltaic (PV) systems based on cost, performance, and reliability inputs for a baseline and a proposed technology. The user can choose inputs and watch the effect on LCOE to determine whether a proposed technology is cost-effective, perform trade-off analysis among different technology options, and do break-even analysis of cost or performance.

Silverman, Timothy↗

Levelized Cost of CO 2 Captured Using Five Physical Solvents in Pre-combustion Applications

Aspen Plus v8.8 was used to perform techno-economic analysis (TEA) of a CO 2 capture process from a typical fuel gas stream in a 543-MW pre-combustion power plant using five different physical solvents (Selexol, PEGPDMS-1, NMP, [aPy][Tf 2 N] and [hmim][Tf 2 N]). The process included a countercurrent packed-bed absorber operating under high-pressure over a wide range of temperatures and three pressure-swing flash drums for solvent regeneration. Furthermore, two packings, Mellapak 250Y and IMTP50, were used and the Levelized costs of CO 2 captured (LCOC) were calculated. The simulation results indicated that using Mellapak 250Y exhibited lower LCOC values than those when using IMTP50 for the five solvents under all conditions used as it offered better mass transfer. The CO 2 capture process carried out at low temperatures showed lower LCOC values than those at higher temperatures due to the increased CO 2 solubility in the solvents at lower temperatures, requiring smaller absorber diameter and lower solvent circulation rates, which offset the cooling requirements. Comparing the lowest LCOC values for the five solvents, the hydrophobic PEGPDMS-1 solvent was the most promising one compared to the other four solvents, due to its lowest capital and operating costs and noncorrosive, which enabled using less expensive materials for the process equipment.

42 ENGINEERING↗

Spatial impacts of technological innovations on the levelized cost of energy for offshore wind power plants in the United States

Recent studies predict significant decreases in the future levelized cost of energy (LCOE) of offshore wind energy, much of which is attributed to anticipated cost reductions from technological innovation. This study evaluates the spatial variability of LCOE caused by technology-induced decreases in a range of capital, operational, and financial cost categories. A spatial cost model of fixed-bottom and floating offshore wind plants is used to model the impact across thousands of potential United States sites. A specified change in an individual turbine subsystem cost produces a range of LCOE outcomes due to the varying geospatial characteristics of the considered sites and the nonlinear, interactive dependency on these input parameters; for example, a 10.8% improvement in net capacity factor can reduce LCOE by between 6% and 20% at different sites. This work expands upon the existing offshore wind literature, which typically evaluates cost sensitivities at a single site and does not consider the spatial variance in LCOE. The results suggest that the impact of technological innovations can be considerable and should be considered on a spatial as well as temporal basis when prioritizing technology innovation research or funding decisions to advance offshore wind technologies in the United States.

17 WIND ENERGY↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Levelized Cost of Electricity (LCOE) Content Model for Design of High Deflection Foils for MHK Applications

The LCOE Content Model provides data submitters with an easy and consistent means of uploading data that can be used to calculate the levelized cost of energy for MHK devices. These data are important to DOE and will be used to develop data products that provide quantitative information to guide and support programmatic decisions. Data will also be used to evaluate MHK products and determine costs and can help data users compare the combination of capital costs and operations and maintenance over time. The ultimate goal is to use these data to perform research and tailor programs to best benefit the industry.

16 TIDAL AND WAVE POWER↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs - including hardware, balance of system, and maintenance costs - and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200 kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.01% efficiency, and an LCOE reduction of 2.0%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters: Preprint

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs -- including hardware, balance of system, and maintenance costs\textemdash and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200-kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.89% efficiency, and an LCOE reduction of 3.6%.

14 SOLAR ENERGY↗

Expert Elicitation for Tidal Energy Levelized Cost of Energy: Present and Future

In accordance with the Government Performance and Results Act (GPRA), H2O annually assesses marine energy technology development resulting from government-funded research and development programs and strategy. For GPRA reporting, H2O uses the levelized cost of energy (LCOE) - which represents the total system cost per unit of energy produced - to measure the progression of marine energy technology development, assess the impact of their research and development programs, and identify future research priorities. To support H2O's GPRA reporting requirements and inform future strategy, the National Laboratory of the Rockies conducted a tidal energy LCOE expert elicitation study to estimate present and future LCOE[AB2.1]. This report describes the motivation and background for the elicitation study, the methodology used to conduct the study, and the study results. It also provides future recommendations for accelerated tidal energy LCOE reduction based on feedback from study participants.

16 TIDAL AND WAVE POWER↗

Levelized Cost of Dispensed Hydrogen for Heavy-Duty Vehicles

This paper estimates the expected ranges of levelized cost of dispensed hydrogen at heavy-duty refueling stations. The analysis assesses a range of scenarios including type of production (centralized vs. onsite, market size in terms of number of vehicles, size of refueling station, utilization rates of the refueling stations, and pathway of delivery of hydrogen). Because delivery of liquid hydrogen is more cost effective at higher volumes than delivery of gaseous hydrogen, this paper only considers delivery of liquid hydrogen except in the case of onsite production.

08 HYDROGEN↗

Wind Levelized Cost of Energy: A Comparison of Technical and Financing Input Variables

The expansion of wind power capacity in the United States has increased the demand for project development capital. In response, innovative approaches to financing wind projects have emerged and are proliferating in the U.S. renewable energy marketplace. Wind power developers and financiers have become more efficient and creative in structuring their financial relationships, and often tailor them to different investor types and objectives. As a result, two similar projects may use very different cash flows and financing arrangements, which can significantly vary the economic competitiveness of wind projects. This report assesses the relative impact of numerous financing, technical, and operating variables on the levelized cost of energy (LCOE) associated with a wind project under various financing structures in the U.S. marketplace. Under this analysis, the impacts of several financial and technical variables on the cost of wind electricity generation are first examined individually to better understand the relative importance of each. Then, analysts examine a low-cost and a high-cost financing scenario, where multiple variables are modified simultaneously. Lastly, the analysis also considers the impact of a suite of financial variables versus a suite of technical variables.

17 WIND ENERGY↗

Prioritizing Transformative Energy Efficiency Technologies in the Pulp and Paper Sector Through Levelized Cost of Conserved Energy

This presentation explores how the U.S. pulp and paper sector can prioritize energy efficiency (EE) technologies using the Levelized Cost of Conserved Energy (LCCE) metric. As mills face market shifts and rising costs, technologies such as advanced drying, membrane concentration, waste heat recovery, and recovery boiler replacements offer potential savings but face economic barriers. LCCE enables consistent comparison of technologies by calculating cost per unit of energy saved, including capital, operating, and potentially non-energy benefits like productivity, maintenance, and safety improvements. Preliminary findings show economies of scale significantly influence recovery boiler replacement feasibility, with larger systems achieving lower LCCE values. Ongoing work incorporates non-energy benefits to provide a more comprehensive cost-effectiveness assessment and guide research, development, and deployment priorities for underutilized and emerging technologies.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗