A commercial spectrometer modified for X-ray spectroscopy of the light elements
Adaptation of vacuum X-ray spectrometer for light element analysis
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Adaptation of vacuum X-ray spectrometer for light element analysis
Humans are returning to the Moon — this time, to stay. NASA has selected a location that maximizes line-of-sight communication with Earth, solar visibility, and access to water ice: the Lunar South Pole (LSP). While the Sun is more consistently in the lunar sky at the poles, it never rises more than 7° above the horizon in the target landing regions. This harsh lighting environment--never experienced during the Apollo missions or in human spaceflight--presents an engineering challenge: Support and protect functional vision. The human vision system, which despite having a high-dynamic range, cannot see well into bright light and cannot adapt quickly from bright to dark or vice versa. The design of helmets, windows, and lighting solutions must work in a complementary fashion to achieve a system of lighting and functional vision support that enables crews to see into darkness while their eyes are light-adapted and see in bright light while still dark-adapted that protects their eyes from injury. This report brings together information and identifies gaps related to LSP Natural environment (topology, regolith, temperature, lighting, and so forth), NASA historical experience exploring the Moon, human vision capabilities and needs, exploration operations, simulation capabilities and needs (for design verification, training, mission planning, and so forth) and existing engineering, safety, medical and performance requirements related to support human exploration.
Methods and systems for low power switching are provided. In one embodiment, an optical switching system is provided. The system comprises at least one optically controlled switch adapted to maintain one of an open state and a closed state based on an associated light signal; and at least one light source adapted to output the associated light signal to the at least one switch, wherein the at least one light source cycles the light signal on and off, wherein the at least one light source is cycled on for a sufficient duration of time and with a sufficient periodicity to maintain the optically controlled switch in one of an open state and a closed state.
A Schlieren apparatus using a bacteriorhodopsin film as an adaptive image grid with white light illumination is demonstrated for the first time. The time dependent spectral properties of the film are characterized. Potential applications include a single-ended Schlieren system for leak detection.
The use of potassium dideuterium phosphate (DKDP) light valves for optical data processing is discussed. The operating principles and structure of optically and electron beam addressed DKDPs are compared, and specifications for both devices given. Optically addressed DKDPs are capable of higher resolution and contrast, but both systems represent viable real time spatial light modulators adaptable to optical processing. Examples of real time data processing performed by the DKDPs include: image addition and subtraction; reduction of noise introduced by scattered light in recording media; reconstruction of computer generated and acoustic holograms; reconstruction of synthetic aperture radar data; retrieval of three-dimensional information in X-ray diagnoses; radar signal processing and display; and optical pattern recognition and correlation of images, which has applications for missile guidance systems.
Following the 2014 launch of the Global Precipitation Measurement Mission (GPM), an unprecedented combination of coincident active and passive microwave observations are available for state of the art precipitation retrieval. The GPM Combined Algorithm forms the backbone of this effort, optimizing geophysical variables for agreement with the multi-spectral information content. Combined retrievals are then utilized, along with a radiative transfer model, as a database applied for retrievals across a constellation of passive microwave radiometers of varying frequencies and viewing geometries. By keeping such retrievals related through the transfer standard of the combined algorithm, level 3 products such as the Integrated Multi-satellitE Retrievals for GPM (IMERG) are able to provide consistent global products for users at the higher temporal resolution required for hydrological applications on the global scale. In the current version of the combined product, precipitation retrievals are carried out only in the presence of a signal from the active radar. As a result, light precipitation and drizzle below the threshold of radar sensitivity are not included in any of the products down the chain from the constellation to IMERG. In this work, the effects of enhancing the retrievals with an optimal estimation-type (OE) water vapor and cloud retrieval using the passive observations are explored over the Southern Ocean on a regional scale. Non-convergence of the OE in areas with no detectable radar signal is used to identify areas with high probability of light precipitation and drizzle. Microphysical scale characterization of the light precipitation will be explored using information derived from the higher sensitivity CloudSat mission along with model information to identify and associate the related atmospheric state and dynamics. This is a physically-based approach requiring radiometric consistency with all available multi-spectral observations. Retrieved drizzle can then be included in the constellation databases continuing across all scales through to the level 3 products. The technique, successfully demonstrated for the Southern Ocean, can be easily adapted for light precipitation retrieval over other areas and surfaces leading to a global climatology of light precipitation.
The photoreactions of nitrated bacteriorhodopsin (bR) are examined. Flash-induced difference spectra of bR, bR with aminotyrosine in position 26 (bR-N26R) and bR with aminotyrosine in position 64 are analyzed. It is observed that changes in the actinic wavelength (from 520 to 500 or 580 nm) have no affect on the shape of the spectra and the formation and decay kinetics of the O and M intermediates. Nitration of tyrosine-64 decreases the chromophore absorbance, shifts the absorption maximum to 535 nm, and affects photocycle kinetics independent of the pK of its phenolic group. Light-dark adaptation spectra for bR are studied. The kinetics of the M and O intermediates in bR with nitrotyrosine in position 64 (bR-N64) and bR with aminotyrosine in position 64 and bR with nitrotyrosine in position 26 and bR-N26R are described and compared to bR; the pH dependence and M and O decay rates are considered. The deprotonation of bR-N64 during the photoreaction cycle and the effects of nitration on the activity of proton pumping are investigated.
NASA-Ames has developed a safe, repeatable, high-precision flying-qualities study system whose Adaptable Target Lighting Array System (ATLAS) furnishes a flying-qualities task that emulates a ground-attack mission with ground-deployed targets lighted in an unpredictable sequence; the pilot must aim the aircraft at whatever target is lighted. Two flight-test programs have been instituted to test the suitability of ATLAS. While the first of these uses a variable-stability aircraft to ascertain whether ATLAS has provided a suitable task for general flying qualities research, using an HUD-tracking task for comparison, the second employed the X-29A FSW research aircraft to demonstrate that ATLAS is appropriate for such research in the case of a specific aircraft.
In order to provide a safe, repeatable, precise, high-gain flying qualities task a ground deployed system was developed and tested at the NASA Ames Research Center's Dryden Flight Research Facility. This system, the adaptable target lighting array system (ATLAS), is based on the German Aerospace Research Establishment's ground attack test equipment (GRATE). These systems provide a flying-qualities task, emulating the ground-attack task with ground deployed lighted targets. These targets light in an unpredictable sequence and the pilot has to aim the aircraft at whichever target is lighted. Two flight-test programs were used to assess the suitability of ATLAS. The first program used the United States Air Force (USAF) NT-33A variability stability aircraft to establish that ATLAS provided a task suitable for use in flying qualities research. A head-up display (HUD) tracking task was used for comparison. The second program used the X-29A forward-swept wing aircraft to demonstrate that the ATLAS task was suitable for assessing the flying qualities of a specific experimental aircraft. In this program, the ground-attack task was used for comparison. All pilots who used ATLAS found it be highly satisfactory and thought it to be superior to the other tasks used in flying qualities evaluations. It was recommended that ATLAS become a standard for flying qualities evaluations.
The events of parturition (labor, delivery, maternal care, placentophagia, and onset of nursing) were analyzed in female Norway rats (Rattus norvegicus) flown on either 11- or 9-day-long spaceflights beginning at the approximate midpoint of their pregnancies. Each space shuttle flight landed on the 20th day of the rats' pregnancies, just 48-72 h before parturition. After spaceflight, dams were continuously monitored and recorded by time-lapse videography throughout the completion of parturition and onset of nursing (days 22 and 23). Analyses of parturition revealed that, compared with ground controls, flight dams displayed twice the number of lordosis contractions, the predominant labor contraction type in rats. The number of vertical contractions (those that immediately precede expulsion of a pup from the womb), the duration of labor, fetal wastage, number of neonates born, neonatal birth weights, placentophagia, and maternal care during parturition, including the onset of nursing, were comparable in flight and ground control dams. Our findings indicate that, with the exception of labor contractions, mammalian pregnancy and parturition remain qualitatively and quantitatively intact after spaceflight during pregnancy.
We previously proposed a flicker visibility metric for bright displays, based on psychophysical data collected at a high mean luminance. Here we extend the metric to other mean luminances. This extension relies on a linear relation between log sensitivity and critical fusion frequency, and a linear relation between critical fusion frequency and log retina lilluminance. Consistent with our previous metric, the extended flicker visibility metric is measured in just-noticeable differences (JNDs).
To help develop technologies for growing edible biomass (food crops) in space, Kennedy Space Center partnered with Orbital Technologies Corporation (ORBITEC), of Madison, Wisconsin, through the Small Business Innovation Research (SBIR) program. One result of this research was the High Efficiency Lighting with Integrated Adaptive Control (HELIAC) system, components of which have been incorporated into a variety of agricultural greenhouse and consumer aquarium lighting features. The new lighting systems can be adapted to a specific plant species during a specific growth stage, allowing maximum efficiency in light absorption by all available photosynthetic tissues.
A semiconductor light emitter comprising a substrate of a semiconductor material having a pair of opposed surfaces and a body of semiconductor material on one of the surfaces. The body includes a pair of clad layers of opposite conductivity types having an intermediate quantum well region therebetween. The clad layers are of a semiconductor material which forms a heterojunction with the material of the quantum well region. The clad layers and the quantum well region form a waveguide which extends along the body. A plurality of gain sections are formed in the body spaced along and optically coupled by the waveguide. Each of the gain sections is adapted to generate light therein when a voltage is placed thereacross. One of the gain section has gratings at each end thereof which are adapted to reflect light back into the one gain section and thereby create a beam of light. The grating between the one gain section and an adjacent gain section is adapted to allow some of the light generated in the one gain section to pass therethrough along the waveguide to the next gain section. Each of the other gain sections have gratings adjacent an end opposite the first gain sections. The periods of the grating are such that no self-oscillation of the light in the waveguide occurs so that each of the other gain sections serve as single pass amplifiers. The gratings also direct the amplified light from the other gain sections out of the body.
Exposure of dark-adapted albino rats to light (350 lux) significantly elevated retinal levels of the dopamine metabolite dihydroxyphenyl acetic acid during the next hour; their return to a dark environment caused dihydroxyphenyl acetic acid levels to fall. Retinal dopamine levels were increased slightly by light exposure, suggesting that the increase in dihydroxyphenyl acetic acid reflected accelerated dopamine synthesis. Administration of tyrosine (100 mg/kg, i.p.) further elevated retinal dihydroxyphenyl acetic acid among light-exposed animals, but failed to affect dopamine release among animals in the dark. These observations show that a physiological stimulus - light exposure - can cause catecholaminergic neurons to become tyrosine-dependent; they also suggest that food consumption may affect neurotransmitter release within the retina.
While dark adapted, two Apollo-Soyuz astronauts saw eighty-two light flash events during a complete 51 deg orbit which passed near the north magnetic pole and through the South Atlantic Anomaly. The frequency of events at the polar parts of the orbit is 25 times that noted in equatorial latitudes and no increased frequency was noted in the South Atlantic Anomaly at the 225-km altitude. The expected flux of heavy particles at the northern and southern points is 1-2/min per eye, and the efficiency for seeing high Z-high energy (HZE) particles which were below the Cerenkov threshold is 50%.
A theoretical model has been developed to describe an experimentally observed spectral shift in the fluorescence emission from phytoplankton as a result of the internal reabsorption of that emission. This model accounts for both the absorption of the primary excitation and the modification of the fluorescence through the reabsorption of the emitted light by the chloroplast and by the surrounding medium. Comparisons are made between the results of the theoretical model and data derived from experiments using a number of different phytoplankton species, each adapted to varying light conditions. The details of the model are discussed, and the consequences of its interpretation on the spectral distribution of the fluorescence emission from phytoplankton are examined.
Artificial gravity (AG) has been proposed as a potential countermeasure to the debilitating physiological effects of long duration space flight. The most economical means of implementing AG may be through the use of a short-radius (2m or less) centrifuge. For such a device to produce gravitational forces comparable to those on earth requires rotation rates in excess of 20 revolutions per minute (rpm). Head turns made out of the plane of rotation at these rates, as may be necessary if exercise is combined with AG, result in cross-coupled stimuli (CCS) that cause adverse side effects including motion sickness, illusory sensations of motion, and inappropriate eye movements. Recent studies indicate that people can adapt to CCS and reduce these side effects by making multiple head turns during centrifuge sessions conducted over consecutive days. However, about 25% of the volunteers for these studies have difficulty tolerating the CCS adaptation paradigm and often drop out due to motion sickness symptoms. The goal of this investigation was to determine whether vivid motor imagery could be used as a pseudostimulus for adapting subjects to this unique environment. Twenty four healthy human subjects (14 males, 10 females), ranging in age from 21 to 48 years (mean 33, sd 7 years) took part in this study. The experimental stimuli were produced using the NASA JSC short-arm centrifuge (SAC). Subjects were oriented supinely on this device with the nose pointed toward the ceiling and head centered on the axis of rotation. Thus, centrifuge rotation was in the body roll plane. After ramp-up the SAC rotated clockwise at a constant rate of 23 rpm, producing a centrifugal force of approximately 1 g at the feet. Semicircular canal CCS were produced by having subjects make yaw head turns from the nose up (NU) position to the right ear down (RED) position and from RED to NU. Each head turn was completed in about one second, and a 30 second recovery period separated consecutive head movements. Participants were randomly assigned to one of three groups (n=8 per group): physical adapters (PA), mental adapters (MA), or a control group (CG). Each subject participated in a one hour test session on each of three consecutive days. Each test session consisted of an initial (preadaptation) period during which the subject performed six CCS maneuvers in the dark, followed by an adaptation period with internal lighting on the centrifuge, and a final (postadaptation) period during which six more CCS maneuvers were performed in the dark. For the PA group, the adaptation period consisted of performing 30 additional CCS maneuvers in the light. For the MA and CG group the centrifuge was ramped down to 0 rpm after the pre-adaptation period and ramped back up to 23 rpm before the post-adaptation period. For the both of these groups, the adaptation period consisted of making 30 CCS maneuvers in the light with the centrifuge stationary (so no cross-coupling occurred). MA group subjects were instructed to vividly imagine the provocative sensations produced by the preadaptation CCS maneuvers in terms of magnitude, duration, and direction of illusory body tilt, as well as any accompanying levels of motion sickness. CG group subjects were asked to answer low imagery content questions (trivial pursuit) during each adaptation period head turn. During the 30 second recovery following each head turn, psychophysical data were collected including self reports of motion sickness, magnitude and direction estimates of illusory body tilt, and the overall duration of these sensations. A multilevel mixed effects linear regression analysis performed on all response variables indicated that all three groups experienced some psychophysical adaptation across the three test sessions. For illusory tilt magnitude, the PA group exhibited the most overall adaptation, followed by the MA group, and the CG group. The slopes of these adaptation trajectories by group over day were significantly diffent from one another. For the perceived duration of sensations, the CG group again exhibited the least amount of adaptation. However, the rates of adaptation of the PA and the MA groups were indistinguishable, suggesting that the imagined pseudostimulus appeared to be just as effective a means of adaptation as the actual stimulus. The MA group's rate of adaptation to motion sickness symptoms was also comparable to the PA group. The use of vivid motor imagery may be an effective method for adapting to the illusory sensations and motion sickness symptoms produced by cross-coupled stimuli. For space-based AG applications, this technique may prove quite useful in retaining astronauts considered highly susceptible to motion sickness as it reduces the number of actual CCS required to attain adaptation.
Ammoniacal silver stain used for light microscopy was adapted advantageously for use with very thin biological sections required for electron microscopy. Silver stain can be performed in short time, has more contrast, and is especially useful for low power electron microscopy.