Search NASA⌕ Search

SEARCH · Search NASA

Results for “light shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of breadboard temperature profiling system for SSME fuel preburner diagnostics

The feasibility of measuring temperatures in the space shuttle main engine (SSME) fuel preburner using spontaneous Raman scattering from molecular hydrogen was studied. Laser radiation is transmitted to the preburner through a multimode optical fiber. Backscattered Raman-shifted light is collected and focused into a second fiber which connects to a remote-located spectrograph and a mutlichannel optical detector. Optics collimate and focus laser light from the transmitter fiber defining the probe volume. The high pressure, high temperature preburner environment was simulated by a heated pressure cell. Temperatures determined by the distribution of Q-branch co-vibrational transitions demonstrate precision and accuracy of 3%. It is indicated heat preburner temperatures can be determined with 5% accuracy with spatial resolution less than 1 cm and temporal resolution of 10 millisec at the nominal preburner operation conditions.

Shirley, J. A.↗

Seedless Laser Velocimetry Using Heterodyne Laser-Induced Thermal Acoustics

A need exists for a seedless equivalent of laser Doppler velocimetry (LDV) for use in low-turbulence or supersonic flows or elsewhere where seeding is undesirable or impractical. A compact laser velocimeter using heterodyne non-resonant laser-induced thermal acoustics (LITA) to measure a single component of velocity is described. Neither molecular (e.g. NO2) nor particulate seed is added to the flow. In non-resonant LITA two beams split from a short-pulse pump laser are crossed; interference produces two counterpropagating sound waves by electrostriction. A CW probe laser incident on the sound waves at the proper angle is directed towards a detector. Measurement of the beating between the Doppler-shifted light and a highly attenuated portion of the probe beam allows determination of one component of flow velocity, speed of sound, and temperature. The sound waves essentially take the place of the particulate seed used in LDV. The velocimeter was used to study the flow behind a rearward-facing step in NASA Langley Research Center's Basic Aerodynamics Research Tunnel. Comparison is made with pitot-static probe data in the freestream over the range 0 m/s - 55 m/s. Comparison with LDV is made in the recirculation region behind the step and in a well-developed boundary layer in front of the step. Good agreement is found in all cases.

Hart, Roger C.↗

NASA Tech Briefs, March 2008

Topics covered include: WRATS Integrated Data Acquisition System; Breadboard Signal Processor for Arraying DSN Antennas; Digital Receiver Phase Meter; Split-Block Waveguide Polarization Twist for 220 to 325 GHz; Nano-Multiplication-Region Avalanche Photodiodes and Arrays; Tailored Asymmetry for Enhanced Coupling to WGM Resonators; Disabling CNT Electronic Devices by Use of Electron Beams; Conical Bearingless Motor/Generators; Integrated Force Method for Indeterminate Structures; Carbon-Nanotube-Based Electrodes for Biomedical Applications; Compact Directional Microwave Antenna for Localized Heating; Using Hyperspectral Imagery to Identify Turfgrass Stresses; Shaping Diffraction-Grating Grooves to Optimize Efficiency; Low-Light-Shift Cesium Fountain without Mechanical Shutters; Magnetic Compensation for Second-Order Doppler Shift in LITS; Nanostructures Exploit Hybrid-Polariton Resonances; Microfluidics, Chromatography, and Atomic-Force Microscopy; Model of Image Artifacts from Dust Particles; Pattern-Recognition System for Approaching a Known Target; Orchestrator Telemetry Processing Pipeline; Scheme for Quantum Computing Immune to Decoherence; Spin-Stabilized Microsatellites with Solar Concentrators; Phase Calibration of Antenna Arrays Aimed at Spacecraft; Ring Bus Architecture for a Solid-State Recorder; and Image Compression Algorithm Altered to Improve Stereo Ranging.

Source record↗

Transient circadian internal desynchronization after light-dark phase shift in monkeys

In four conscious chair-acclimatized squirrel monkeys (Saimiri sciureus) studied with lights on (600 lx) from 0800 to 2000 hr daily, prominent 24-hr rhythms in feeding, drinking, activity, body temperature, and urinary potassium, sodium, and water excretion were seen. When the monkeys were subjected to 36 hr of darkness followed by 36 hr of light, each variable demonstrated a circadian rhythm which was not passively dependent on the light-dark cycle. After the 24-hr light-dark cycle was abruptly phase-delayed by 8 hr, all the rhythms resynchronized with the new light-dark cycle phase, demonstrating that light-dark cycles are an effective zeitgeber. However, the resynchronization of the rhythms of feeding, drinking, activity, and body temperature was 90% complete within approximately 2 days while the 90% resynchronization of the urinary rhythms took approximately 5 days. These results suggest that the circadian timing system in S. sciureus may consist of several spontaneously oscillating units which can become transiently uncoupled during perturbations of environmental time cues.

Moore-Ede, M. C.↗

The timing of the human circadian clock is accurately represented by the core body temperature rhythm following phase shifts to a three-cycle light stimulus near the critical zone

A double-stimulus experiment was conducted to evaluate the phase of the underlying circadian clock following light-induced phase shifts of the human circadian system. Circadian phase was assayed by constant routine from the rhythm in core body temperature before and after a three-cycle bright-light stimulus applied near the estimated minimum of the core body temperature rhythm. An identical, consecutive three-cycle light stimulus was then applied, and phase was reassessed. Phase shifts to these consecutive stimuli were no different from those obtained in a previous study following light stimuli applied under steady-state conditions over a range of circadian phases similar to those at which the consecutive stimuli were applied. These data suggest that circadian phase shifts of the core body temperature rhythm in response to a three-cycle stimulus occur within 24 h following the end of the 3-day light stimulus and that this poststimulus temperature rhythm accurately reflects the timing of the underlying circadian clock.

Non-NASA Center↗

Resynchronization of circadian sleep-wake and temperature cycles in the squirrel monkey following phase shifts of the environmental light-dark cycle

Circadian rhythms in physiological and behavioral functions gradually resynchronize after phase shifts in environmental time cues. In order to characterize the rate of circadian resynchronization in a diurnal primate model, the temperature, locomotor activity, and polygraphically determined sleep-wake states were monitored in squirrel monkeys before and after 8-h phase shifts of an environmental light-dark cycle of 12 h light and 12 h dark (LD 12:12). For the temperature rhythm, resynchronization took 4 d after phase delay shift and 5 d after phase advance shift; for the rest-activity cycle, resynchronization times were 3 d and 6 d, respectively. The activity acrophase shifted more rapidly than the temperature acrophase early in the post-delay shift interval, but this internal desynchronization between rhythms disappeared during the course of resynchronization. Further study of the early resynchronization process requires emphasis on identifying evoked effects and measuring circadian pacemaker function.

Wexler, D. B.↗

Novel Optical Technique Developed and Tested for Measuring Two-Point Velocity Correlations in Turbulent Flows

A novel technique for characterizing turbulent flows was developed and tested at the NASA Glenn Research Center. The work is being done in collaboration with the University of Pittsburgh, through a grant from the NASA Microgravity Fluid Physics Program. The technique we are using, Homodyne Correlation Spectroscopy (HCS), is a laser-light-scattering technique that measures the Doppler frequency shift of light scattered from microscopic particles in the fluid flow. Whereas Laser Doppler Velocimetry gives a local (single-point) measurement of the fluid velocity, the HCS technique measures correlations between fluid velocities at two separate points in the flow at the same instant of time. Velocity correlations in the flow field are of fundamental interest to turbulence researchers and are of practical importance in many engineering applications, such as aeronautics.

Zimmerli, Gregory A.↗

Circadian countermeasures for shiftworkers during USMP-2: A report to mission management

People who must work at night experience a number of physiological and psychological difficulties. These include sleepiness and fatigue at work, poor daytime sleep, gastrointestinal distress, impaired concentration and performance, disturbed mood, and increased health complaints and risk of disease. These difficulties arise because nocturnal work and daytime sleep take place at inappropriate phases of the body's circadian rhythms. Intense artificial light can shift the phase of human circadian rhythms, and can thus be used to promote adaptation to shifted work schedules. The first attempts to investigate the efficacy of light treatment for MSFC POCC shiftworkers took place during USML-1 and ATLAS-2. The findings from these studies led to the development of a Circadian Countermeasures Program that was implemented during USMP-2. Light treatment and other circadian countermeasures were employed to promote adjustment to mission shiftwork in POCC cadre volunteers. Treatment protocols were designed and customized for each volunteer's work hours and personal preferences. Treatment protocols included some or all of the following: scheduled self-administration of intense light, scheduled avoidance or attenuation of sunlight at other times, and sleep schedules. Data from post-mission questionnaires indicated that volunteers found the program to be effective, convenient, and beneficial.

Stewart, Karen T.↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

Interplanetary dust

Progress in the study of interplanetary dust during the past four years is reviewed. Attention is given to determinations of the relative contributions of interstellar dust grains, collisional debris from the asteroid belt and short-period comets to the interplanetary dust cloud. Effects of radiation pressure and collisions on particle dynamics are discussed, noting the discovery of the variation of the orbital parameters of dust particles at 1 AU with size and in situ measurements of dust density between 0.3 and 5 AU by the Helios and Pioneer spacecraft. The interpretation of the zodiacal light as produced by porous absorbing particles 10 to 100 microns in size is noted, and measurements of the Doppler shift, light-producing-particle density, UV spectrum, photometric axis and angular scattering function of the zodiacal light are reported. Results of analyses of lunar rock microcraters as to micrometeoroid density, flux rate, size distribution and composition are indicated and interplanetary dust particles collected from the stratosphere are discussed. Findings concerning the composition of fragile meteoroid types found as cosmic spherules in deep sea sediments are also presented.

Brownlee, D. E.↗

The second-order gravitational red shift

The direct measurement of the nonlinear term of the gravitational field equations by using very stable clocks is discussed along with measuring the perhelion advance of a planet or satellite. These are considered measurements of the second-order gravitational red shift. The exact expression for the frequency shift of light in a gravitational field is derived. Other topics discussed include: The Doppler-cancelling technique; the second-order red shift in a spherically symmetric gravitational field; finite signal transit time; and the reality and interpretation of coordinates in the second-order red shift experiment.

Jaffe, J.↗

Laser-Doppler gas-velocity instrument

Three-D instrument using a laser light source measures both turbulence and mean velocity of subsonic and supersonic gas flows. This instrument is based on the measurement of the Doppler frequency shift of light waves scattered by moving particles in the gas stream.

Booth, S.↗

Resetting of circadian melatonin and cortisol rhythms in humans by ordinary room light

The present study was designed to investigate whether a weak photic stimulus can reset the endogenous circadian rhythms of plasma melatonin and plasma cortisol in human subjects. A stimulus consisting of three cycles of 5 h exposures to ordinary room light (approximately 180 lux), centered 1.5 h after the endogenous temperature nadir, significantly phase-advanced the plasma melatonin rhythm in eight healthy young men compared with the phase delays observed in eight control subjects who underwent the same protocol but were exposed to darkness (p < or = 0.003). After light-induced phase advances, the circadian rhythms of plasma melatonin and plasma cortisol maintained stable temporal relationships with the endogenous core body temperature cycle, consistent with the conclusion that exposure to ordinary indoor room light had shifted a master circadian pacemaker.

Non-NASA Center↗

Light and buffer-gas frequency shifts in the Rb-85 maser frequency standard.

The effect of buffer gas and pumping light on the output frequency of the Rb-85 maser is discussed. In contrast to a primary standard, these frequency shifts can be used to advantage when it is necessary to operate the maser at a frequency which differs from the ground-state hyperfine frequency by a few kilohertz. Using appropriate mixtures of buffer gas and carefully shaped lamp spectral profiles, it is also possible to operate the maser exactly at the ground-state hyperfine frequency. It is pointed out that the short-term phase stability of the maser is not impaired by these shifts.

Stern, W. A.↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

On-axis velocity component measurement with laser velocimeters

The application of Doppler shifted laser light to the measurement of the two velocity components normal to the optical axis of the system is relatively simple as compared to the measurement of the on-axis velocity component. The present paper deals with the reference-beam (local oscillator) technique and the dual-beam (fringe mode) technique, which have been developed for measuring the on-axis component. Some results obtained for the on-axis component are examined.

Neti, S.↗

Investigation of stimulated Brillouin scattering switching in mid infrared fibers

Backward stimulated Brillouin scattering (SBS) has been experimentally studied in midinfrared transparent AgCl and KRS-5 fibers. In the present scheme, pump transmission through the fibers and acoustooptic radiative effects are simultaneously observed. The SBS shifted scattered light spectrum is investigated by laser heterodyne spectroscopy using HgCdTe and very fast metal-oxide-metal diode broadband mixers. The results suggest that reflection under high incident laser power departs from simple Fresnel surface reflection.

Yu, Chung↗