Search NASA⌕ Search

SEARCH · Search NASA

Results for “lightning mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

31 records · Page 2

3D Radio Frequency Mapping and Polarization Observations Show Lightning Flashes Were Ignited by Cosmic‐Ray Showers

Previous 2D radio frequency interferometric observations showed that lightning is commonly started with a positive fast discharge (+FD) before a normal negative leader continues from the origin of the +FD to the ensuing lightning flash. However, the inception and development of the +FD cannot be convincingly explained by existing discharge theories. With our new 3D broadband interferometric mapping and polarization system, we observed that the +FD was sometimes followed by an even faster and more extensive negative discharge (−FD) that propagated backward and overshoot the origin by a few hundred meters, as reported by an earlier 2D study. Surprisingly, the signal polarization, which measures the orientation of the discharge current, systematically slanted from the discharge propagation direction and rotated between the two opposite discharges, showing the +FD and −FD were driven by other storm-independent factors in addition to the storm electric field, or otherwise all would align in the same direction. Assuming a cosmic-ray shower (CRS) piercing through the cloud immediately before the +FD/−FD discharge, we found that their path is consistent with a pre-ionized path by the CRS, and the polarizations for the two opposite discharges are consistent with the respective deflected trajectories of high-energy positrons and electrons in the geomagnetic and an electric field. We further analyzed the more commonly observed +FD and showed that it is consistent with the CRS interpretation, suggesting these flashes in thunderstorms were ignited by cosmic-ray showers.

58 GEOSCIENCES↗

The Nature of Standing Plasma Waves Following Fast Breakdown in Thunderstorms

Narrow bipolar events (NBEs) are produced by large-scale systems of streamer corona discharges that occur inside thunderstorms and radiate intensely at very-high frequencies. Here we examine 14 high-power NBEs recorded in Florida which are followed by a lasting oscillatory signal. We isolate the dominant frequencies of the oscillations using empirical mode decomposition methods, and cross-reference this information with the radiator size inferred from broadband interferometry. We conclude that the oscillations are evidence of a standing electromagnetic wave in the plasma cavity created by the preceding streamer system, that is, the cavity's fundamental mode with wavelength equal to twice the radiator length. Contrasting the dispersive and attenuation properties of these waves across several different events allows us to conclude that the cavity is filled with ions resulting in an average conductivity of 0.01–0.1 mS/m, which are left behind after the streamers decay via electron attachment to oxygen molecules.

58 GEOSCIENCES↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Optimizing Management of Persistent Data Structures in High-Performance Analytics

Large-scale data analytics workflows ingest massive input data into various data structures, including graphs and key-value datastores. These data structures undergo multiple transformations and computations and are typically reused in incremental and iterative analytics workflows. Persisting in-memory views of these data structures enables reusing them beyond the scope of a single program run while avoiding repetitive raw data ingestion overheads. Memory-mapped I/O enables persisting in-memory data structures without data serialization and deserialization overheads. However, memory-mapped I/O lacks the key feature of persisting consistent snapshots of these data structures for incremental ingestion and processing. The obstacles to efficient virtual memory snapshots using memory-mapped I/O include background writebacks outside the application’s control, and the significantly high storage footprint of such snapshots. To address these limitations, we present Privateer, a memory and storage management tool that enables storage-efficient virtual memory snapshotting while also optimizing snapshot I/O performance. Here, we integrated Privateer into Metall, a state-of-the-art persistent memory allocator for C++, and the Lightning Memory-Mapped Database (LMDB), a widely-used key-value datastore in data analytics and machine learning. Privateer optimized application performance by 1.22× when storing data structure snapshots to node-local storage, and up to 16.7× when storing snapshots to a parallel file system. Privateer also optimizes storage efficiency of incremental data structure snapshots by up to 11× using data deduplication and compression.

Computer science↗

Graupel and Hail Identification Algorithm for the Dual-frequency Precipitation Radar (DPR) on the GPM Core Satellite

Precipitation consists of many types of hydrometeors, such as raindrops, ice crystals, graupel, and hail. Due to their impacts, graupel and hail (GH) have received particular attention in the literature. Global Precipitation Measurement (GPM) dual-frequency radar (DPR) has proved to be a very reliable system for global precipitation retrievals. This paper aims to develop a GH identification algorithm for GPM DPR. This algorithm is constructed using a precipitation type index (PTI) defined for DPR. The PTI is effective in separating hydrometeor types and is calculated using measurements of reflectivity, dual-frequency ratio, and storm top height data. The output of the algorithm is a Boolean product representing the existence of graupel or hail along with the vertical profile for each Ku- and Ka-band matched footprint. Cross validation is performed with the Weather Service Radar (WSR-88D) network over continental United States as well as during the Remote sensing of Electrification, Lightning, and Mesoscale/Microscale Processes with Adaptive Ground Observations (RELAMPAGO) experiment. Evaluation of the GH identification algorithm is performed on a global basis, which illustrates promising comparisons with the global lightning and hail precipitation maps generated using radar and radiometer.

54 ENVIRONMENTAL SCIENCES↗

Combined Optical and Radio-Frequency Measurements of a Lightning Megaflash by the FORTE Satellite

The optical and VHF instrumentation on the Fast On-Orbit Recording of Transient Events (FORTE) satellite is used to document the combined phenomenology evolution of a lightning “megaflash” – mesoscale lightning that propagates laterally over exceptional distances. We identify a FORTE flash whose maximum extent was 82 km and inferred length over multiple distinct branches exceeded 100 km. This flash lasted 1.2 s and produced 250 optical and 591 RF events. We find that the channel development mapped by FORTE’s pixelated lightning imager (LLS) occurred at a typical speed of 2.6x10 5 m s -1 and was accompanied by sustained periods of VHF emission that could individually exceed 100 ms in duration. The impulsive IC events generated by the flash indicate that this development occurred at altitudes between 3 and 8 km. Four +CG strokes were identified in the VHF waveform data that are responsible for two of the three highly-radiant LLS groups (two of the +CGs were not as optically bright as the others). These strokes occurred at different locations throughout the flash footprint with the most distant strokes separated by approximately 50 km. These space-based observations match previous observations of megaflashes as well as ground-based measurements of negative leader development during “spider” lightning, suggesting that FORTE is sensing the same phenomena.

Peterson, Michael Jay↗

Insights Into Lightning K‐Leader Initiation and Development From Three Dimensional Broadband Interferometric Observations

Abstract We report detailed observations of K‐leaders and the activity between them with the three‐dimensional Broadband Interferometric Mapping and Polarization system (BIMAP‐3D) at Los Alamos National Laboratory. It is found that K‐leaders have a general propagation trend of initial acceleration and then gradual deceleration, and the corresponding very high frequency (VHF) radiation power is exponentially correlated with the leader speed. Based on the 3D development and simultaneous electric field change measurement, some simple K‐leaders can be modeled with time‐evolving point charges at the propagating leader tip and at the stationary origin. We found that the charge magnitude increases during the initial acceleration stage and stays relatively constant for the rest of the development. K‐leaders are observed to interact with other branches; the branches affect the leader's propagation speed, and may affect the charge transfer. After the occurrence of a K‐leader, VHF emissions are quenched for several milliseconds. VHF sources then reappear in an impulsive and scattered manner as “twinkling,” and these sources are found not uniquely on the so‐called needles, but also on the main channel. These twinkling sources start near the apparent positive leader tip, and extend back toward the direction of the flash origin at about 10 5 m/s, while the apparent positive tip continues to extend forward at about 10 4 m/s. The twinkling extending toward the direction of flash origin appears to initiate the following K‐leader, although it may be interrupted by a K‐leader along a different branch, or simply die out without more K‐leader activity.

54 ENVIRONMENTAL SCIENCES↗

Estimating the Electric Fields Driving Lightning Dart Leader Development With BIMAP‐3D Observations

Abstract In this paper, a numerical dart leader model has been implemented to understand the leader's development and the corresponding electric field changes observed by the 3D broadband mapping and polarization (BIMAP‐3D) system. The model assumes the extending leader channel is equipotential and has a linear charge distribution induced by an ambient electric field. The charge distribution induced by the ambient field can be used to model the electric field change at the ground. We then find the ambient electric field which best fits the field change measurements at the two BIMAP stations. The estimated ambient electric field decreases in the direction of dart leader propagation. Our observations and modeling results are consistent with our earlier hypothesis that dart leader speed is proportional to the electric field at the leader tip. The model also supports our earlier analysis that leader speed variations near branch junctions were due to previous charge deposits near the junctions. The modeled tip electric field is generally lower than the breakdown field unless the pre‐dart‐leader channel has a significant temperature of 3,000 K. This is consistent with the fact that dart leaders typically do not form new branches into the virgin air. Furthermore, the tip field is generally close to the negative streamer stability field at ambient temperatures, explaining the nature of the narrow and well‐defined channel structure. In addition to the charge distribution and the ambient and tip electric field, the development of the channel potential and current distribution are also presented.

3D lightning mapping↗

Data for “Lightning Interferometry Uncertainty, “Focused Interferometry”, and Evidence of Lightning being Ignited by a Cosmic-ray Shower” by Shao et al.

This summarizes the data from our broadband RF interferometric mapping and polarization (BIMAP) system used to produce the figures in the revised manuscript “Lightning Interferometry Uncertainty, “Focused Interferometry”, and Evidence of Lightning being Ignited by a Cosmic-ray Shower” that was originally submitted to Journal of Geophysical Research (JGR) for publication. Note that the original manuscript was titled ““Focused Interferometry” and Fine Structure of Lightning-Initiating Fast Positive Streamers” and was released with LA-UR-19-32549. In accordance with JGR’s data policy (https://www.agu.org/Publish-withAGU/Publish/Author-Resources/Policies/Data-policy), it is the intention to make this data publicly available at the time of article submission. The data set includes raw BIMAP RF data and processed results for two lightning flashes. The data is available in two files (“FPS_data_20170606_361.sav” and “Small_IC_20180520_205644_408.sav”) located at “/home/xshao/HEPL/Analysis” which were packaged with IDL save commend. The raw data includes 3 channels of RF data, 2 channels of RF polarization data, and 1 channel of electric field change data. The processed data includes the RF source positions, source position uncertainties, and the polarization analysis.

58 GEOSCIENCES↗

Meteorological environments associated with California wildfires and their potential roles in wildfire changes during 1984-2017

California has been seeing more wildfires in recent years, resulting in huge economic losses and threatening human health. Clarifying the meteorological environments of wildfires is foundational to improving the understanding and prediction of wildfires and their impacts. Here, 1535 California wildfires during 1984-2017 are systematically investigated. Based on two key meteorological factors - temperature and moisture anomalies - all wildfires are classified into four groups: hot-dry, hot-wet, cold-dry, cold-wet. Most (~60%) wildfires occurred on hot-dry days. Compositing the large-scale environments of the four groups shows that persistent high pressure and strong northeasterly wind descending from inland favor hot-dry conditions for wildfires. This analysis also reveals an important role of anomalies in southerly onshore flow that supports stronger convection, accompanied by more lightning flashes that provide a triggering mechanism for wildfires under hot-wet conditions. Self-organizing map analysis lends confidence in the large-scale meteorological pattern for dominating hot-dry wildfires in California. Besides wildfire occurrence, wildfire size is also influenced by meteorological anomalies through their magnitudes. Among them, moisture anomaly explains the largest fraction (~69%) of variability in wildfire sizes. Large-scale meteorological anomalies are found to play an important role in the devastating 2018 wildfire season in California. During 1984-2017, wildfire burned area has significantly increased by ~3.6% per year, indicating a doubling of burned area in 2017 relative to 1984, with the trend dominated by hot-dry wildfires in summer. Drying and warming in conjunction with strengthening of the high pressure in summer support more frequent and larger wildfires in California.

58 GEOSCIENCES↗

Soil Temperature and Moisture within the Kougarok Fire Complex, Kougarok Road Mile Marker 86, Seward Peninsula, Alaska, 2019-2023

Daily averages of soil temperature and moisture measured once every hour at different heights located at Intensive Monitoring Stations within the Kougarok Fire Complex, Kougarok Road Mile Marker 86 site. Data were retrieved annually from 2019-2023. Package contains 21 *.CSV data files plus a file level metadata *.CSV, data dictionary *.CSV, data file inventory *.CSV, and sensor location site map *.JPG. Data files have header rows, NaN fields indicate invalid or missing data, and negative vertical offsets are above ground.The Kougarok tundra fire complex (KFC) is located north of Nome and the Kigluaik Mountains, near Quartz Creek and the Kougarok River. The site is accessed by foot from the end of the Nome-Taylor Highway (mile marker 86; also called the Kougarok or Beam Road). The KFC burned in six major fires in the decades since 1950 (Alaska Interagency Coordination Center, unpublished data). Lightning ignited five of these fires (1971, 1997, 2015, and 2019) and one was human caused (2002). The mosaic of overlapping fire scars allows for the study of repeat fires in the tundra which, until recently, was not a common phenomenon outside the boreal forest in Alaska. Our reference unburned tundra fire site is south of the KFC located at mile marker 80 of the Nome-Taylor Highway.The two most recent fires are the Mingvk Lake (2015; 21,698 acres burned from 7/27/2015 to 9/28/2015) and Garfield Creek (2019; 422 acres burned from 7/31/2019 to 8/20/19). The Mingvk Lake fire scar includes areas that burned 1-4x (1971, 1997, 2002), while the entirety of the Garfield Creek fire scar has burned 2x previously (1971, 2002).Previous research at the KFC focused on permafrost (Liljedahl et al. 2007; Narita et al. 2015; Iwahana et al. 2016; Tsuyuzaki, Iwahana, and Saito 2017) and vegetation (Narita et al. 2015; Hollingsworth et al. 2021) response to fire. The central Seward Peninsula is characterized by continuous permafrost with a thickness of 15 to 30 m and a mean active layer thickness of 56 cm (Hinzman et al. 2003). Sloping hills with mixed shrub–tussock tundra and tussock tundra vegetation in the uplands are characteristic of the region. Three micrometeorological towers near the Kougarok field site recorded a mean annual temperature of −2.4°C, mean January temperature of −23.1°C, mean July temperature of +11°C, and mean summer rainfall (June–August) of 94 mm from 2000 to 2006 (Liljedahl et al. 2007).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Spatial variability in Arctic–boreal fire regimes influenced by environmental and human factors

Abstract Wildfire activity in Arctic and boreal regions is rapidly increasing, with severe consequences for climate and human health. Regional long-term variations in fire frequency and intensity characterize fire regimes. The spatial variability in Arctic–boreal fire regimes and their environmental and anthropogenic drivers, however, remain poorly understood. Here we present a fire tracking system to map the sub-daily evolution of all circumpolar Arctic–boreal fires between 2012 and 2023 using 375 m Visible Infrared Imaging Radiometer Suite active fire detections and the resulting dataset of the ignition time, location, size, duration, spread and intensity of individual fires. We use this dataset to classify the Arctic–boreal biomes into seven distinct ‘pyroregions’ with unique climatic and geographic environments. We find that these pyroregions exhibit varying responses to environmental drivers, with boreal North America, eastern Siberia and northern tundra regions showing the highest sensitivity to climate and lightning density. In addition, anthropogenic factors play an important role in influencing fire number and size, interacting with other factors. Understanding the spatial variability of fire regimes and its interconnected drivers in the Arctic–boreal domain is important for improving future predictions of fire activity and identifying areas at risk for extreme events.

Geology↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗