Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear OPF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

Development of a Distribution Optimal Power Flow Federate for Open-Source OEDI-SI Platform

Increasing numbers of distributed generators in the electric power distribution networks require developing a control strategy to optimize solutions in real time. Linearized optimal distribution flow development has seen growth and acceptance in the distribution systems literature for efficiently modeling the \glspl{opf} for distribution systems. This paper examines the implementation and integration procedure for linearized optimal distribution flow federate to \gls{oedisi} platform. Specifically, we discuss i) the usage of the \gls{oedisi} platform, ii) obtaining a tractable solution using developed \gls{opf} federate, and iii) validation of solutions and bench-marking the \gls{oedisi} platform with developed \gls{opf} federate using OpenDSS. In brief, we demonstrate how a general linearized optimal distribution flow federate can be developed and integrated with a co-simulation environment to mimic real-world examples. The efficacy of the proposed method is demonstrated using the IEEE 123-bus test system under different scenarios to obtain a tractable solution and compare its results.

Sadnan, Rabayet↗

Well Abandonment at Various Sites, John F. Kennedy Space Center, Florida

Between January 29 and March 9, 2016, a total of 23 monitoring wells were properly abandoned-in-place at five KSC sites (OPF-1&2, OPF-3, RDG, SRB, and HSB). The total abandonment encompassed 489.06 linear feet. The wells abandoned were constructed of PVC with diameters ranging from 1-inch to 2-inches. The shallowest well abandoned was measured to be 11.6 ft bls (OPF) and the deepest well abandoned was documented to be 51.45 feet bls (HSB). All aboveground completions were removed and each area was re-graded and/or grouted to surface to match existing surroundings. All materials (concrete pads, well casings, etc.) were disposed of accordingly.

MW↗

Learning Optimal Solutions for Extremely Fast AC Optimal Power Flow

We develop, in this paper, a machine learning approach to optimize the real-time operation of electric power grids. In particular, we learn feasible solutions to the AC optimal power flow (OPF) problem with negligible optimality gaps. The AC OPF problem aims at identifying optimal operational conditions of the power grids that minimize power losses and/or generation costs. Due to the computational challenges with solving this nonconvex problem, many efforts have focused on linearizing or approximating the problem in order to solve the AC OPF on faster timescales. However, many of these approximations can be fairly poor representations of the actual system state and still require solving an optimization problem, which can be time consuming for large networks. In this work, we learn a mapping between the system loading and optimal generation values, enabling us to find near-optimal and feasible AC OPF solutions. This allows us to bypass solving the traditionally nonconvex AC OPF problem, resulting in a significant decrease in computational burden for grid operators.

machine learning↗

Learning Optimal Solutions for Extremely Fast AC Optimal Power Flow: Preprint

We develop, in this paper, a machine learning approach to optimize the real-time operation of electric power grids. In particular, we learn feasible solutions to the AC optimal power flow (OPF) problem with negligible optimality gaps. The AC OPF problem aims at identifying optimal operational conditions of the power grids that minimize power losses and/or generation costs. Due to the computational challenges with solving this nonconvex problem, many efforts have focused on linearizing or approximating the problem in order to solve the AC OPF on faster timescales. However, many of these approximations can be fairly poor representations of the actual system state and still require solving an optimization problem, which can be time consuming for large networks. In this work, we learn a mapping between the system loading and optimal generation values, enabling us to find near-optimal and feasible AC OPF solutions. This allows us to bypass solving the traditionally nonconvex AC OPF problem, resulting in a significant decrease in computational burden for grid operators.

machine learning↗

An Online Joint Optimization–Estimation Architecture for Distribution Networks

Here in this article, we propose an optimal joint optimization-estimation architecture for distribution networks, which jointly solves the optimal power flow (OPF) problem and static state estimation (SE) problem through an online gradient-based feedback algorithm. The main objective is to enable a fast and timely interaction between the OPF decisions and state estimators with limited sensor measurements. First, convergence and optimality of the proposed algorithm are analytically established. Then, the proposed gradient-based algorithm is modified by introducing statistical information of the inherent estimation and linearization errors for an improved and robust performance of the online OPF decisions. Overall, the proposed method eliminates the traditional separation of operation and monitoring, where optimization and estimation usually operate at distinct layers and different time scales. Hence, it enables a computationally affordable, efficient, and robust online operational framework for distribution networks under time-varying settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials

The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.

Mattson, C. B.↗

Stochastic multi-period optimal dispatch of energy storage in unbalanced distribution feeders

This report presents a convex, multi-period, AC-feasible Optimal Power Flow (OPF) framework that robustly dispatches flexible demand-side resources in unbalanced distribution feeders against uncertainty in very-short timescale solar Photo-Voltaic (PV) forecasts. This is valuable for power systems with significant behind-the-meter solar PV generation as their operation is affected by uncertainty from forecasts of demand and solar PV generation. The aim of this work is then to ensure the feasibility and reliability of distribution system operation under high solar PV penetration. We develop and present a novel, robust OPF formulation that accounts for both the nonlinear power flow constraints and the uncertainty in forecasts. This is achieved by linearizing an optimal trajectory and using first-order methods to systematically tighten voltage bounds. Case studies on a realistic distribution feeder shows the effectiveness of a receding-horizon implementation.

25 ENERGY STORAGE↗

HydraGNN v5.0

HydraGNN v5.0 expands the code base into a more portable, scalable, and flexible framework for scientific graph learning, with particular strength in atomistic machine-learning interatomic potentials and large-scale distributed training. The release adds Fully Sharded Data Parallel (FSDP) support alongside existing DDP and DeepSpeed paths, including FSDP-aware checkpointing and optimizer integration, and introduces a configurable multi-precision training workflow supporting FP32, BF16, and FP64 across GPUs and Intel XPUs. For atomistic modeling, HydraGNN v5.0 strengthens its MLIP capabilities through dynamic graph construction at every forward pass, energy-conserving force prediction via automatic differentiation, and per-atom energy loss formulations, while extending EGNN models to properly handle periodic boundary conditions. The release also broadens model expressiveness through graph-level attribute conditioning, adds new multi-task and model-parallel extensions such as MACE support and encoder/decoder branch optimization, and expands application coverage with integrated examples for datasets including OC25, Nabla2-DFT, QCML, Open Polymers 2026, and OPF. In parallel, HydraGNN v5.0 improves production readiness through performance optimizations for large-scale runs, stratified sampling and linear-regression preprocessing utilities, and tested installation scripts for DOE supercomputers including Frontier, Aurora, Perlmutter, and Andes. Overall, the release advances HydraGNN as a robust software platform for scalable graph neural networks across materials science, chemistry, and scientific machine learning workflows

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗

OptiBench: An Optimization Benchmark Tool for Renewable Energy Problems

We propose a benchmark framework and visualization tool, OptiBench, for analyzing the performance of state-of-the-art optimization solvers across a variety of optimization problems in renewable energy research. Our framework is designed from the ground up in the Julia programming language and enables analysis at scale on high performance computing (HPC) systems. Our visualization tool allows effortless evaluation of optimization solver performance, robustness, and accuracy through intuitive plots, e.g., performance profiles, heat maps, and distribution plots. We have tested three benchmark suites relevant to the modeling of renewable energy systems, viz., CUTEst, PGLib-OPF, and WaterTAP water treatment optimization problems. We illustrate benchmarking of CUTEst using OptiBench on the National Renewable Energy Laboratory's (NREL) HPC Kestrel. Our findings indicate that MA57 HSL linear solver demonstrated the best overall performance for an experimental IPOPT implementation. Our work is ongoing and we intend to add support for more optimization solvers and benchmark test suites in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OptiBench: An Optimization Benchmark Tool for Renewable Energy Problems

We propose a benchmark framework and visualization tool, OptiBench, for analyzing the performance of state-of-the-art optimization solvers across a variety of optimization problems in renewable energy research. Our framework is designed from the ground up in the Julia programming language and enables analysis at scale on high performance computing (HPC) systems. Our visualization tool allows effortless evaluation of optimization solver performance, robustness, and accuracy through intuitive plots, e.g., performance profiles, heat maps, and distribution plots. We have tested three benchmark suites relevant to the modeling of renewable energy systems, viz., CUTEst, PGLib-OPF, and WaterTAP water treatment optimization problems. We illustrate benchmarking of CUTEst using OptiBench on the National Laboratory of the Rockies's (NLR) HPC Kestrel. Our findings indicate that MA57 HSL linear solver demonstrated the best overall performance for an experimental IPOPT implementation. Our work is ongoing and we intend to add support for more optimization solvers and benchmark test suites in the future.

97 MATHEMATICS AND COMPUTING↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous- enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks: Preprint

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous–enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Modeling and Rapid Prototyping of Integrated Transmission-Distribution OPF Formulations with PowerModelsITD.jl

Conventional electric power systems are composed of different unidirectional power flow stages of generation, transmission, and distribution, managed independently by transmission system and distribution system operators. However, as distribution systems increase in complexity due to the integration of distributed energy resources, coordination between transmission and distribution networks will be imperative for the optimal operation of the power grid. However, coupling models and formulations between transmission and distribution is non-trivial, in particular due to the common practice of modeling transmission systems as single-phase, and distribution systems as multi-conductor phase-unbalanced. To enable the rapid prototyping of power flow formulations, in particular in the modeling of the boundary conditions between these two seemingly incompatible data models, we introduce PowerModelsITD.jl, a free, open-source toolkit written in Julia for integrated transmission-distribution (ITD) optimization that leverages mature optimization libraries from the InfrastructureModels.jl-ecosystem. The primary objective of the proposed framework is to provide baseline implementations of steady-state ITD optimization problems, while providing a common platform for the evaluation of emerging formulations and optimization problems. In this work, we introduce the nonlinear formulations currently supported in PowerModelsITD.jl, which include AC-polar, AC-rectangular, current-voltage, and a linear network transportation model. Results are validated using combinations of IEEE transmission and distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗