At least 37 records · Page 2

The role of fast and slow dynamics in nonlinear resonant ultrasound spectroscopy of consolidated granular materials

Abstract Elastic nonlinearity observed in consolidated granular media can be attributed to the combination of slow and fast effects, which give rise to hysteresis and relaxation of both modulus and damping after the sample is perturbed. A consequence is a high level of complexity in the measurements of the sample linear and nonlinear elastic parameters. The results of experiments are dependent on the experimental protocol that is adopted to measure the relevant quantities and it is hard to quantify parameters with accuracy and repeatability. Here we focus on examining Nonlinear Resonant Ultrasound Spectroscopy, showing experimentally the role of slow dynamics in the process and quantifying/discussing its influence on the quantification of nonlinearity. We also propose a model to describe the process, which shows that different contributions to nonlinearity (e.g., classical and hysteretic) could be due to physical features (defects) relaxing with different relaxation times.

Science & Technology - Other Topics↗

Gradient process parameter optimization in additive friction stir deposition of aluminum alloys

As one of the most novel additive manufacturing methods, currently selection and optimization of processing parameters in additive friction stir deposition (AFSD) have mainly relied on experiments and subsequent characterization of microstructural and mechanical properties. Such approaches are both time- and resource-consuming. Therefore, an ultrasound elastography enhanced gradient process parameter optimization method was applied in the present work to obtain a window of optimized processing parameters for AFSD processing of aluminum alloy by varying both rotational and linear deposition speeds. Further, the quality of AFSD processed layer was investigated for physical nature of surface, dynamic elastic modulus, and microstructural aspects in cross-sections of the deposited layer. The efficiency in exploring process parameters was significantly enhanced by implementing a high-throughput screening experimental design based on application of gradient process parameters and continuous ultrasound elastographs. In addition, the applied ultrasonic elastography technique assisted in evaluating the homogeneity in microstructure and mechanical properties of AFSD sample over the entire gradients of the process parameters. The techniques adopted in current work can be further extended to identify suitable parameters for AFSD fabrication of components with desired mechanical properties such as hardness, fatigue, etc.

36 MATERIALS SCIENCE↗

Application of Laser Based Ultrasound for NDE of Damage in Thick Stitched Composites

As design engineers implement new composite systems such as thick, load bearing composite structures, they must have certifiable confidence in structure s durability and worthiness. This confidence builds from understanding the structural response and failure characteristics of simple components loaded in testing machines to tests on full scale sections. Nondestructive evaluation is an important element which can provide quantitative information on the damage initiation, propagation, and final failure modes for the composite structural components. Although ultrasound is generally accepted as a test method, the use of conventional ultrasound for in-situ monitoring of damage during tests of large structures is not practical. The use of lasers to both generate and detect ultrasound extends the application of ultrasound to in- situ sensing of damage in a deformed structure remotely and in a non-contact manner. The goal of the present research is to utilize this technology to monitor damage progression during testing. The present paper describes the application of laser based ultrasound to quantify damage in thick stitched composite structural elements to demonstrate the method. This method involves using a Q-switched laser to generate a rapid, local linear thermal strain on the surface of the structure. This local strain causes the generation of ultrasonic waves into the material. A second laser used with a Fabry-Perot interferometer detects the surface deflections. The use of fiber optics provides for eye safety and a convenient method of delivering the laser over long distances to the specimens. The material for these structural elements is composed of several stacks of composite material assembled together by stitching through the laminate thickness that ranging from 0.5 to 0.8 inches. The specimens used for these nondestructive evaluation studies had either impact damage or skin/stiffener interlaminar failure. Although little or no visible surface damage existed, internal damage was detected by laser based ultrasound.

Anastasi, Robert F.↗

Ultrasound Characterization of Plastic Bonded Explosives With Varied Binder Content and Density

Advanced explosive formulations and methods of production require rapid characterization for both processes and materials. Here, we present results for ultrasound characterization of a plastic bonded explosive (PBX) formulation as a function of binder weight percent and pressing density using through-transmission sound speed measurements. The explosive in this study was composed of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) combined with the fluoropolymer binder Kynar Ultraflex B. Binder content ranged from 2.6 wt.% to 11.5 wt.% with associated explosive formulation densities from 1.69 g/cc to 1.89 g/cc. We find linear and nonlinear changes in longitudinal and shear sound speeds, peak frequencies, and measured elastic properties for the different PBX formulations. These measured changes can differentiate the tested formulations, highlighting the potential for ultrasound as a nondestructive characterization method for newly-formulated PBXs. We also demonstrate through-transmission measurements using different coupling media and present results from an ultrasound technique called resonant ultrasound spectroscopy (RUS). Both transmission and RUS approaches may allow for rapid and even automated characterization of PBX components suitable for high-throughput manufacturing operations.

Engineering↗

Characterization of the Nonlinear Elastic Properties of Graphite/Epoxy Composites Using Ultrasound

The normalized change in ultrasonic "natural" velocity as a function of stress and temperature was measured in a unidirectional laminate of T300/5208 graphite/epoxy composite using a pulsed phase locked loop ultrasonic interferometer. These measurements were used together with the linear (second order) elastic moduli to calculate some of the nonlinear (third order) moduli of this material.

Prosser, William H.↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Origin of the quasi-quantized Hall effect in ZrTe 5

The quantum Hall effect (QHE) is traditionally considered to be a purely two-dimensional (2D) phenomenon. Recently, however, a three-dimensional (3D) version of the QHE was reported in the Dirac semimetal ZrTe 5 . It was proposed to arise from a magnetic-field-driven Fermi surface instability, transforming the original 3D electron system into a stack of 2D sheets. Here, we report thermodynamic, spectroscopic, thermoelectric and charge transport measurements on such ZrTe 5 samples. The measured properties: magnetization, ultrasound propagation, scanning tunneling spectroscopy, and Raman spectroscopy, show no signatures of a Fermi surface instability, consistent with in-field single crystal X-ray diffraction. Instead, a direct comparison of the experimental data with linear response calculations based on an effective 3D Dirac Hamiltonian suggests that the quasi-quantization of the observed Hall response emerges from the interplay of the intrinsic properties of the ZrTe 5 electronic structure and its Dirac-type semi-metallic character.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

Ultrasonic nondestructive materials characterization

A brief review of ultrasonic wave propagation in solid materials is presented with consideration of the altered behavior in anisotropic and nonlinear elastic materials in comparison with isotropic and linear elastic materials. Some experimental results are described in which ultrasonic velocity and attenuation measurements give insight into materials microstructure and associated mechanical properties. Recent developments with laser beam non-contact generation and detection of ultrasound are presented. The results of several years of experimental measurements using high-power ultrasound are discussed, which provide substantial evidence of the inability of presently accepted theories to fully explain the interaction of ultrasound with solid materials. Finally, a special synchrotron X-ray topographic system is described which affords the possibility of observing direct interaction of ultrasonic waves with the microstructural features of real crystalline solid materials for the first time.

Green, R. E., Jr.↗

Characterization of Advanced Manufactured Surface Acoustic Wave Sensor for Temperature Measurement in Nuclear Applications

As part of a collaborative effort between Idaho National Laboratory and the Boise State University, printed SAW transducers were developed. The transducers were first modelled and evaluated for optimum performance, then fabricated using several piezoelectric substrates. These printed SAW-sensors were tested for temperature sensing ability and found to be highly sensitive and with a very linear response over the tested range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of elastic properties of an additively manufactured lattice using resonant ultrasound spectroscopy

Development of improved approaches in the characterization of additively manufactured structures continues to be a topic of interest for the advanced manufacturing community. This article will investigate an approach using resonant ultrasound spectroscopy (RUS) to determine the effective elastic constants of an orthotropic lattice structure. The evaluation is performed on a cube shaped 316 L stainless steel test specimen, constructed using selective laser melting techniques. The approach uses RUS techniques in conjunction with the assumption that in the frequency regime of interest, the wavelength of the diagnostic ultrasound is greater than the discrete structural features of the unit cell of the lattice; thus, the AM structure can be treated as an anisotropic continuum with effective material properties and symmetry inherited from the unit cell. The RUS analysis estimates the nine elastic coefficients associated with orthotropic sample symmetry, which, in turn, are used to determine the elastic moduli and Poisson ratios. Current results show good agreement between experiments and modeled data. Comparisons to published results are also in good agreement, indicating the potential applicability of this characterization technique for estimating the linear elastic properties of innovative additive manufactured metal lattice structures.

36 MATERIALS SCIENCE↗

Resonant ultrasound spectroscopy for crystalline samples containing initial strain

Resonant ultrasound spectroscopy (RUS) is a mature and robust technique for the nondestructive characterization of the elastic properties of solids capable of providing the elastic constants of anisotropic crystalline solids. The traditional method is based on assuming that the solid is linear elastic and, therefore, obeys a linearized Hookean constitutive relationship (Hooke’s law). In this work, an alternative constitutive law is provided that allows for an initial strain or prestrain to be present stemming from residual stress. Then, the constitutive relationship is integrated into the RUS framework. The model is demonstrated using a realistic prestrain field obtained by simulating shot-peening processing of a polycrystalline Cu sample. The sensitivity of the resonances to the developed prestrain is established and discussed. This work allows researchers to consider the influence of initial strain or residual stress in their samples and the potential influence on accurate elastic constant estimates. The model also supports the potential of RUS for the nondestructive characterization of prestrain in materials.

42 ENGINEERING↗

Spin-strain interactions under hydrostatic pressure in α-RuCl 3

We investigate the effects of hydrostatic pressure on 𝛼−RuCl 3 , a prototypical material for the Kitaev spin model on a honeycomb lattice with a possible spin-liquid ground state. Using ultrasound measurements at pressures up to 1.16 GPa, we reveal significant modifications of the acoustic properties and the 𝐻−𝑇 phase diagram of this material. Hydrostatic pressure suppresses the three-dimensional magnetic order and induces a dimerization transition at higher pressures. At low pressures, the sound attenuation exhibits a linear temperature dependence, while above 0.28 GPa, it becomes nearly temperature independent, suggesting a shift in the phonon scattering regime dominated by Majorana fermions. These findings provide new insights into spin-strain interactions in Kitaev magnets and deliver a detailed characterization of the 𝐻−𝑇 phase diagram of 𝛼−RuCl 3 under hydrostatic pressure.

Focused ion beam↗

Characterization of nonlinear ultrasonic waves behavior while interacting with poor interlayer bonds in large-scale additive manufactured materials

Over the past decades, researchers have developed several nonlinear ultrasonic techniques for quality control of materials commonly used in different applications. Owing to the superior sensitivity of nonlinear ultrasound waves to small defects such as micro-cracks, their applicability in different nondestructive testing (NDT) problems has been investigated in numerous studies. These studies utilize frequency domain analysis to detect the generation of higher harmonics because of the formation of defects in the inspected medium. Frequency domain analysis based on the Fourier transform is a significant approach used in linear systems; however, it may not perform adequately on nonlinear systems. Hence, studies on nonlinear dynamics and physics consider analyzing systems' behavior in the phase-space domain. In contrast to the frequency domain analysis, which can result in information loss, analysis in the phase-space domain retains all the information regarding a system's states. Here, we investigate the nonlinearities induced by poor interlayer bonding in polymer-based additive manufactured parts in the phase-space domain. It is convenient to characterize the nonlinearity in the phase-space domain because it provides a geometrical representation of a system's states. Two types of low quality interlayer bond are considered. The first type is simulated artificially while the second type is manufactured by reducing the bond quality during the printing process. The analysis verified that the received ultrasonic signals exhibit classical nonlinear behavior in the phase-space domain while interacting with simulated poor interlayer bonds. In addition, the results showed that the behavior of ultrasonic waves is amplitude-dependent and evolves into models that have not been previously reported. Furthermore, Largest Lyapunov Exponent (LLE) is used to quantify the behavior of nonlinear ultrasonic waves while interacting with poor interlayer bonds. Using LLE, it was observed that the divergence rate of the phase-space trajectories depends on the amplitude of the excitation. This observation quantitatively proves that nonlinear behavior of ultrasound while interacting with poor interlayer bonds can be amplitude-dependent. The results of both simulated and inherent poor interlayer bond cases showed that LLE can be used as a reliable quantitative damage-sensitive feature to detect and potentially characterize weak bonds, which are difficult to detect using conventional approaches. Additionally, the reported results in the phase-space domain provide a basis for proposing a new mathematical model for ultrasonic waves interacting with poor interlayer bonds.

36 MATERIALS SCIENCE↗

Determination of single-crystal elastic moduli of Li RE F 4 ( RE =Y, Gd, and Tb) by resonant ultrasound spectroscopy

The tetragonal fluoro-scheelite Li RE F 4 compounds (RE = rare earth) have been shown to exhibit a variety of useful optical and magnetic properties. While LiYF 4 has been widely studied, many of the fundamental thermodynamic properties of other members of this family remain unknown. Here, we report the complete elastic tensors (C ij ) of single-crystalline LiYF 4 , LiTbF 4 , and LiGdF 4 using resonant ultrasound spectroscopy and density functional theory (DFT). Here we compare the results for LiYF 4 with prior experimental results using time-of-flight ultrasound methods. This is the first report, however, of the experimental elastic tensors of LiTbF 4 and LiGdF 4 . The present results point to a softening of the elastic moduli of the Li RE F 4 system when Y is replaced by the larger ionic radius of Tb or Gd. Furthermore, we find that just 0.3% doping with Nd on the Y site also leads to a slight softening of the moduli. The variation of the elastic moduli as a function of temperature up to 216°C was also measured. A nearly linear softening of all seven independent elastic moduli was observed with increasing temperature. Phonon dispersions and phonon density of states obtained by DFT support the experimental finding of a significantly higher sound velocity due to lighter Y atoms in LiYF 4 , as compared to heavier LiTbF 4 and LiGdF 4 .

36 MATERIALS SCIENCE↗

Vascular mechanics of the coronary artery

This paper describes our research into the vascular mechanics of the coronary artery and plaque. The three sections describe the determination of arterial mechanical properties using intravascular ultrasound (IVUS), a constitutive relation for the arterial wall, and finite element method (FEM) models of the arterial wall and atheroma. METHODS: Inflation testing of porcine left anterior descending coronary arteries was conducted. The changes in the vessel geometry were monitored using IVUS, and intracoronary pressure was recorded using a pressure transducer. The creep and quasistatic stress/strain responses were determined. A Standard Linear Solid (SLS) was modified to reproduce the non-linear elastic behavior of the arterial wall. This Standard Non-linear Solid (SNS) was implemented into an axisymetric thick-walled cylinder numerical model. Finite element analysis models were created for five age groups and four levels of stenosis using the Pathobiological Determinants of Atherosclerosis Youth (PDAY) database. RESULTS: The arteries exhibited non-linear elastic behavior. The total tissue creep strain was epsilon creep = 0.082 +/- 0.018 mm/mm. The numerical model could reproduce both the non-linearity of the porcine data and time dependent behavior of the arterial wall found in the literature with a correlation coefficient of 0.985. Increasing age had a strong positive correlation with the shoulder stress level, (r = 0.95). The 30% stenosis had the highest shoulder stress due to the combination of a fully formed lipid pool and a thin cap. CONCLUSIONS: Studying the solid mechanics of the arterial wall and the atheroma provide important insights into the mechanisms involved in plaque rupture.

NASA Program Biomedical Research and Countermeasur↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

60 Days of Head-down Bedrest Differentially Alters Venous Function in Lower and Upper Body Between Healthy Men and Women

The incidence of orthostatic intolerance after space flight is disproportionally higher in female compared to male crewmembers (83% vs. 20%). Experimental and human data suggest that the loss of orthostatic tolerance is due, at least in part, to microgravity-induced changes in venous compliance and that these changes are specific to the lower body. It is unknown however, whether the changes in venous compliance are different between males and females after space flight, and whether this is related to the disparity in orthostatic intolerance between the sexes. Using 6deg head-down bed rest (BR) as a model of space flight, we tested the following hypotheses; 1) females, compared to males, would experience a greater increase in venous compliance in dorsal foot veins as an effect of BR and 2) no differences in venous compliance would be found in dorsal hand veins between sexes and across BR days. Using 2-D ultrasound, dorsal hand (DHV) and foot vein (DFV) responses (diameter; expressed as sq mm) to 40 mmHg of congestion pressure (compliance) and to intravenous infusion of phenylephrine (PE; 3160ng/min) were determined in 10 females and 16 males before and after 60 days of BR. The relation between changes in vein diameter (in response to pressure and PE), sex, limb, and BR days were determined using a mixed-effect linear regression. It was found that after 60 days of BR, DFV dilator response to pressure was significantly greater in females and significantly less in males compared to pre-BR. As expected, there were no differences in DHV dilator response between sexes nor was there a significant difference between pre and post measures within groups. Notably, the venoconstrictor response to infusions of PE in the DHV and DFV where similar between sexes and across BR days. In conclusion, this study demonstrates that after 60 days of BR, dorsal foot veins are more compliant in women and less compliant in men. Moreover, the changes in lower body vein compliance in females do not appear to be due to changes in vasoconstrictor tone as their response to PE was preserved and similar to that in males. Taken together these data suggest that the higher incidence of orthostatic intolerance in females after space flight is due to increased venous compliance in the lower body which could translate to lower venous filling pressures and a reduced stroke volume.

Westby, Christian M.↗