Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis and test of insulated components for rotary engine

The direct-injection stratified-charge (DISC) rotary engine, while attractive for aviation applications due to its light weight, multifuel capability, and potentially low fuel consumption, has until now required a bulky and heavy liquid-cooling system. NASA-Lewis has undertaken the development of a cooling system-obviating, thermodynamically superior adiabatic rotary engine employing state-of-the-art thermal barrier coatings to thermally insulate engine components. The thermal barrier coating material for the cast aluminum, stainless steel, and ductile cast iron components was plasma-sprayed zirconia. DISC engine tests indicate effective thermal barrier-based heat loss reduction, but call for superior coefficient-of-thermal-expansion matching of materials and better tribological properties in the coatings used.

Badgley, Patrick R.↗

Cool Sportswear

New athletic wear design based on the circulating liquid cooling system used in the astronaut's space suits, allows athletes to perform more strenuous activity without becoming overheated. Techni-Clothes gear incorporates packets containing a heat-absorbing gel that slips into an insulated pocket of the athletic garment and is positioned near parts of the body where heat transfer is most efficient. A gel packet is good for about one hour. Easily replaced from a supply of spares in an insulated container worn on the belt. The products, targeted primarily for runners and joggers and any other athlete whose performance may be affected by hot weather, include cooling headbands, wrist bands and running shorts with gel-pack pockets.

Source record↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Physiologic and thermal responses of male and female patients with multiple sclerosis to head and neck cooling

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the thermal and physiologic responses of patients with multiple sclerosis to short-term maximal head and neck cooling. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 24 female and 26 male patients with multiple sclerosis in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 degrees C), were cooled for 30 min by the liquid cooling garment, which was operated at its maximum cooling capacity. Oral, right, and left ear temperatures and cooling system parameters were logged manually every 5 min. Forearm, calf, chest, and rectal temperatures, heart rate, and respiration rate were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. This protocol was performed during the winter and summer to investigate the seasonal differences in the way patients with multiple sclerosis respond to head and neck cooling. No significant differences were found between the male and female subject group's mean rectal or oral temperature responses during any phase of the experiment. The mean oral temperature decreased significantly (P < 0.05) for both groups approximately 0.3 degrees C after 30 min of cooling and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 15 min after removal of the cooling helmet. The mean rectal temperatures decreased significantly (P < 0.05) in both male and female subjects in the winter studies (approximately 0.2-0.3 degrees C) and for the male subjects during the summer test (approximately 0.2 degrees C). However, the rectal temperature of the female subjects did not change significantly during any phase of the summer test. These data indicate that head and neck cooling may, in general, be used to reduce the oral and body temperatures of both male and female patients with multiple sclerosis by the approximate amount needed for symptomatic relief as shown by other researchers. However, thermal response of patients with multiple sclerosis may be affected by gender and seasonal factors, which should be considered in the use of liquid cooling therapy.

NASA Discipline Environmental Health↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

Water immersion facility general description, spacecraft design division, crew station branch

The Water Immersion Facility provides an accurate, safe, neutral buoyancy simulation of zero gravity conditions for development of equipment and procedures, and the training of crews. A detailed description is given of some of the following systems: (1) water tank and support equipment; (2) communications systems; (3) environmental control and liquid cooled garment system (EcS/LCG); (4) closed circuit television system; and (5) medical support system.

Source record↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

Atmospheric cloud physics laboratory project study

Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.

Schultz, W. E.↗

International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space suit for the moon.

Apollo space suit design discussing construction, purpose and operating conditions of liquid-cooled life support system

APOLLO PROJECT↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

Thermo-Fluid Modeling Framework for Supercomputer Digital Twins: Part 1, Demonstration at Exascale

A thermo-fluid modeling framework is being developed for ExaDigiT---an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. The work is being conducted in two parts, and discussion is divided into two companion papers. The work documented in this paper focuses on the development of a cooling system library in Dymola for the Frontier supercomputer at Oak Ridge National Laboratory. The second part, outlined in a companion paper, focuses on a templating structure called Auto-CSM for easily creating model-agnostic, physics-based thermo-fluid cooling system models for liquid-cooled supercomputers using a text-based schema. The cooling model is being developed using primarily the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library. The library follows the templating architecture developed within the TRANSFORM library for modeling subsystems. A full-system validation was performed to validate a very simple model that is integrated with the system controls, and the results are presented herein.

Kumar, Vineet↗

Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable-launch-vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable-launch-vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

Ambur, Damodar R.↗

Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable launch vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable launch vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

Ambur, Damodar R.↗