Loads calibrations of strain gage bridges on the DAST project Aeroelastic Research Wing (ARW-2)

Results from and details of the procedure used to calibrate strain gage bridges for measurements of wing structural loads, shear (V), bending moment (M), and torque (T), at three semispan stations on both the left and right semispans of the ARW-2 wing are presented. The ARW-2 wing has a reference area of 35 square feet, a span of 19 feet, an aspect ratio of 10.3, a midchord line sweepback angle of 25 degrees, and a taper ratio of 0.4. The ARW-2 wing was fabricated using aluminum spars and ribs covered with a fiberglass/honeycomb sandwich skin material. All strain gage bridges are mounted along with an estimate of their accuracy by means of a comparison of computed loads versus actual loads for three simulated flight conditions.

Eckstrom, C. V.↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low- load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the gage sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

A study of the effect of radical load distributions on calibrated strain gage load equations

For several decades, calibrated strain gages have been used to measure loads on airplanes. The accuracy of the equations used to relate the strain gage measurements to the applied loads has been based primarily on the results of the load calibration. An approach is presented for studying the effect of widely varying load distributions on strain gage load equations. The computational procedure provides a link between the load calibration and the load to be measured in flight. A matrix approach to equation selection is presented, which is based on equation standard error, load distribution, and influence coefficient plots of the strain gage equations, and is applied to a complex, delta-wing structure.

Jenkins, J. M.↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low-load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the bridge sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

An analysis of cross-coupling of a multicomponent jet engine test stand using finite element modeling techniques

A two axis thrust measuring system was analyzed by using a finite a element computer program to determine the sensitivities of the thrust vectoring nozzle system to misalignment of the load cells and applied loads, and the stiffness of the structural members. Three models were evaluated: (1) the basic measuring element and its internal calibration load cells; (2) the basic measuring element and its external load calibration equipment; and (3) the basic measuring element, external calibration load frame and the altitude facility support structure. Alignment of calibration loads was the greatest source of error for multiaxis thrust measuring systems. Uniform increases or decreases in stiffness of the members, which might be caused by the selection of the materials, have little effect on the accuracy of the measurements. It is found that the POLO-FINITE program is a viable tool for designing and analyzing multiaxis thrust measurement systems. The response of the test stand to step inputs that might be encountered with thrust vectoring tests was determined. The dynamic analysis show a potential problem for measuring the dynamic response characteristics of thrust vectoring systems because of the inherently light damping of the test stand.

Schweikhard, W. G.↗

The use of a simplified structural model as an aid in the strain gage calibration of a complex wing

The use of a relatively simple structural model to characterize the load responses of strain gages located on various spars of a delta wing is examined. Strains measured during a laboratory load calibration of a wing structure are compared with calculations obtained from a simplified structural analysis model. Calculated and measured influence coefficient plots that show the shear, bending, and torsion characteristics of typical strain gage bridges are presented. Typical influence coefficient plots are shown for several load equations to illustrate the derivation of the equations from the component strain gage bridges. A relatively simple structural model was found to be effective in predicting the general nature of strain distributions and influence coefficient plots. The analytical processes are shown to be an aid in obtaining a good load calibration. The analytical processes cannot, however, be used in lieu of an actual load calibration of an aircraft wing.

Jenkins, J. M.↗

Correction of high-frequency noise-temperature inaccuracies

Deep-space mission data rates to Earth are limited by the system operating noise-temperature (T(sub op)) performance of the DSN. This article addresses some of the techniques and definitions used for measuring and reporting the effective noise temperature of receivers (Te) and T(sub op) of the DSN's ground receiving systems. Calibration loads are used to measure T(sub op) of the DSN antennas. At 32 GHz, a calibration load cooled to 2-K physical temperature requires a correction of 0.67 K to determine the noise temperature. Using corrected noise temperature for the calibration loads results in the correct values for T(sub op) such that the total system noise power can be defined by Pn = kT(sub op) B, as required for DSN telecommunications design control tables. T(sub op) and Te should not be converted to equivalent physical temperatures.

Stelzreid, C. T.↗

Performance of the Rotor Systems Research Aircraft calibrated rotor loads measurement system

The compound Rotor Systems Research Aircraft (RSRA) is designed to make high accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for any errors and to ensure that measurement system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis has been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight, and analytical methods have been devised to eliminate its effects on calibration data. Flight tests confirmed that the calibrated rotor loads measurement system performs as expected in flight, and that it can dependably make direct measurements of fuselage vertical drag in hover.

Acree, C. W., Jr.↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Strain-gage balance calibration of a magnetic suspension and balance system

A load calibration of the NASA 13-in magnetic suspension and balance system (MSBS) is described. The calibration procedure was originally intended to establish the empirical relationship between the coil currents and the external loads (forces and moments) applied to a magnetically suspended calibrator. However, it was discovered that the performance of a strain-gage balance is not affected when subjected to the magnetic environment of the MSBS. The use of strain-gage balances greatly reduces the effort required to perform a current-vs.-load calibration as external loads can be directly inferred from the balance outputs while a calibrator is suspended in MSBS. It is conceivable that in the future such a calibration could become unnecessary, since an even more important application for the use of a strain-gage balance in MSBS environment is the acquisition of precision aerodynamic force and moment data by telemetering the balance outputs from a suspended model/core/balance during wind tunnel tests.

Roberts, Paul W.↗

Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

Ferris, A. T. Judy↗

Analysis of Sting Balance Calibration Data Using Optimized Regression Models

Calibration data of a wind tunnel sting balance was processed using a candidate math model search algorithm that recommends an optimized regression model for the data analysis. During the calibration the normal force and the moment at the balance moment center were selected as independent calibration variables. The sting balance itself had two moment gages. Therefore, after analyzing the connection between calibration loads and gage outputs, it was decided to choose the difference and the sum of the gage outputs as the two responses that best describe the behavior of the balance. The math model search algorithm was applied to these two responses. An optimized regression model was obtained for each response. Classical strain gage balance load transformations and the equations of the deflection of a cantilever beam under load are used to show that the search algorithm s two optimized regression models are supported by a theoretical analysis of the relationship between the applied calibration loads and the measured gage outputs. The analysis of the sting balance calibration data set is a rare example of a situation when terms of a regression model of a balance can directly be derived from first principles of physics. In addition, it is interesting to note that the search algorithm recommended the correct regression model term combinations using only a set of statistical quality metrics that were applied to the experimental data during the algorithm s term selection process.

Ulbrich, N.↗

The Millimeter-Wave Imaging Radiometer (MIR)

The Millimeter-Wave Imaging Radiometer (MIR) is a new instrument being designed for studies of airborne passive microwave retrieval of tropospheric water vapor, clouds, and precipitation parameters. The MIR is a total-power cross-track scanning radiometer for use on either the NASA ER-2 (high-altitude) or DC-8 (medium altitude) aircraft. The current design includes millimeter-wave (MMW) channels at 90, 166, 183 +/- 1,3,7, and 220 GHz. An upgrade for the addition of submillimeter-wave (SMMW) channels at 325 +/- 1,3,7 and 340 GHz is planned. The nadiral spatial resolution is approximately 700 meters at mid-altitude when operated aboard the NASA ER-2. The MIR consists of a scanhead and data acquisition system, designed for installation in the ER-2 superpod nose cone. The scanhead will house the receivers (feedhorns, mixers, local oscillators, and preamplifiers), a scanning mirror, hot and cold calibration loads, and temperature sensors. Particular attention is being given to the characterization of the hot and cold calibration loads through both laboratory bistatic scattering measurements and analytical modeling. Other aspects of the MIR and the data acquisition system are briefly discussed, and diagrams of the location of the MIR in the ER-2 superpod nosecone and of the data acquisition system are presented.

Gasiewski, A. J.↗