Search NASA⌕ Search

SEARCH · Search NASA

Results for “load duration curve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hugoniot properties of porous stainless steel: Insights from molecular dynamics simulations

Here, we present a systematic study of Hugoniot properties of porous 316L stainless steel using both a simple interpolation scheme and direct shock simulations in order to probe pore collapse kinetics as well as final thermodynamic states. Both methods indicate that equilibrated Hugoniot properties depend on pore density only and not on the pore distribution or size. We then create a simple porous equation of state model that is shown to be accurate for a range of validation data. This allows us to extend our simulations to make direct comparison to experimental data that have generally significantly larger system sizes and durations. In addition, our direct shock simulations indicate that the relaxation time after hotspot formation is system size dependent and can reach nanosecond timescales for the largest pores investigated in our study, thereby possibly having a measurable effect on fast dynamic loading experiments.

36 MATERIALS SCIENCE↗

Cardiovascular function in space flight

Changes in orthostatic heart rate have been noted universally in Soviet and U.S. crewmembers post space flight. The magnitude of these changes appears to be influenced by mission duration, with increasing orthostatic intolerance for the first 7-10 days of flight and then a partial recovery in the orthostatic heart rate response. Fluid loading has been used as a countermeasure to this postflight orthostatic intolerance. Previous reports have documented the effectiveness of this technique, but it has also been noted that the effectiveness of volume expansion diminishes as flight duration exceeds one week. The response of carotid baroreceptor function was investigated utilizing a commercially available neck collar which could apply positive and negative pressure to effect receptor stimulation. Bedrest studies had validated the usefulness and validity of the device. In these studies it was shown that carotid baroreceptor function curves demonstrated less responsiveness to orthostatic stimulation than control individuals. Twelve Space Shuttle crewmembers were examined pre- and postflight from flights lasting from 4-5 days. Plots of baroreceptor function were constructed and plotted as change in R-R interval vs. carotid distending pressure (an orthostatic stimulus). Typical sigmoidal curves were obtained. Postflight the resting heart rate was higher (smaller R-R interval) and the range of R-R value and the slope of the carotid sigmoidal response were both depressed. These changes were not significant immediately postflight (L + O), but did become significant by the second day postflight (L + 2), and remained suppressed for several days thereafter. It is hypothesized that the early adaptation to space flight involves a central fluid shift during the initial days of flight, but subsequent alterations in neural controlling mechanisms (such as carotid baroreceptor function) contribute to orthostatic intolerance.

Review↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Deterministic Multiaxial Creep and Creep Rupture Enhancements for CARES/Creep Integrated Design Code

High temperature and long duration applications of monolithic ceramics can place their failure mode in the creep rupture regime. A previous model advanced by the authors described a methodology by which the creep rupture life of a loaded component can be predicted. That model was based on the life fraction damage accumulation rule in association with the modified Monkman-Grant creep rupture criterion. However, that model did not take into account the deteriorating state of the material due to creep damage (e.g., cavitation) as time elapsed. In addition, the material creep parameters used in that life prediction methodology, were based on uniaxial creep curves displaying primary and secondary creep behavior, with no tertiary regime. The objective of this paper is to present a creep life prediction methodology based on a modified form of the Kachanov-Rabotnov continuum damage mechanics (CDM) theory. In this theory, the uniaxial creep rate is described in terms of sum, temperature, time, and the current state of material damage. This scalar damage state parameter is basically an abstract measure of the current state of material damage due to creep deformation. The damage rate is assumed to vary with stress, temperature, time, and the current state of damage itself. Multiaxial creep and creep rupture formulations of the CDM approach are presented in this paper. Parameter estimation methodologies based on nonlinear regression analysis are also described for both, isothermal constant stress states and anisothermal variable stress conditions This creep life prediction methodology was preliminarily added to the integrated design code CARES/Creep (Ceramics Analysis and Reliability Evaluation of Structures/Creep), which is a postprocessor program to commercially available finite element analysis (FEA) packages. Two examples, showing comparisons between experimental and predicted creep lives of ceramic specimens, are used to demonstrate the viability of Ns methodology and the CARES/Creep program.

Jadaan, Osama M.↗

Deterministic and Probabilistic Creep and Creep Rupture Enhancement to CARES/Creep: Multiaxial Creep Life Prediction of Ceramic Structures Using Continuum Damage Mechanics and the Finite Element Method

High temperature and long duration applications of monolithic ceramics can place their failure mode in the creep rupture regime. A previous model advanced by the authors described a methodology by which the creep rupture life of a loaded component can be predicted. That model was based on the life fraction damage accumulation rule in association with the modified Monkman-Grant creep ripture criterion However, that model did not take into account the deteriorating state of the material due to creep damage (e.g., cavitation) as time elapsed. In addition, the material creep parameters used in that life prediction methodology, were based on uniaxial creep curves displaying primary and secondary creep behavior, with no tertiary regime. The objective of this paper is to present a creep life prediction methodology based on a modified form of the Kachanov-Rabotnov continuum damage mechanics (CDM) theory. In this theory, the uniaxial creep rate is described in terms of stress, temperature, time, and the current state of material damage. This scalar damage state parameter is basically an abstract measure of the current state of material damage due to creep deformation. The damage rate is assumed to vary with stress, temperature, time, and the current state of damage itself. Multiaxial creep and creep rupture formulations of the CDM approach are presented in this paper. Parameter estimation methodologies based on nonlinear regression analysis are also described for both, isothermal constant stress states and anisothermal variable stress conditions This creep life prediction methodology was preliminarily added to the integrated design code CARES/Creep (Ceramics Analysis and Reliability Evaluation of Structures/Creep), which is a postprocessor program to commercially available finite element analysis (FEA) packages. Two examples, showing comparisons between experimental and predicted creep lives of ceramic specimens, are used to demonstrate the viability of this methodology and the CARES/Creep program.

Jadaan, Osama M.↗

Calibration of CDM-Based Creep Constitutive Model Using Accelerated Creep Test (ACT) Data

In conventional creep testing (CCT) a specimen is subject to constant load and temperature for a long-duration until creep rupture occurs. Conventional testing can be costly when considering the number of experiments needed to characterize the creep response of a material over a range of stress and temperature. To predict long-term creep-rupture properties, the time-temperature-stress superposition principle (TTSSP) approach has been employed where stress and/or temperature is applied at an elevated level; the result of which are extrapolated down to low stress and/or temperature conditions. These methods have been successful in predicting minimum-creep-strain-rate (MCSR) and stress-rupture (SR) but suffer from an inability to predict the creep deformation curve or account for changes in deformation mechanisms or aging that occurs at long-duration. An accelerated technique, termed the Stepped isostress method (SSM) allows the accelerated testing of materials to determine their creep deformation response. Unlike TTSSP tests, the SSM test employs a single specimen where the stress is periodically step increased until rupture. The SSM creep deformation curve is processed (time and strain shifted) to produce an accelerated creep deformation curve that represent the creep deformation curve at the initial stress level in SSM. A processing procedure for metals has yet to be developed. The research objective of this study is to develop a processing procedure for SSM test data using a creep-damage constitutive model. Triplicate SSM tests were conducted on Ni-based superalloy Inconel 718 at 650°C with stress being periodically increased until rupture. Triplicate CCT tests were conducted at the initial stress level of the SSM tests. The Sine-hyperbolic (Sinh) creep-damage model was employed in this study. The Sinh creep-damage constitutive model is based on coupled creep strain rate and damage evolution equations; where both rates are dependent on the current state of damage. Calibration is two-step: analytical and numerical optimization. Each stepped creep deformation curve is tackled quasi-analytically to determine MCSR and SR related material constants and accumulated damage. The damage accumulated at the end of each step was then passed onto subsequent steps to calibrate the MCSR, rupture prediction, and damage evolution. Numerical optimization was applied to optimize model constants involved in the creep strain constitutive equations in order to generate best-fitted Sinh creep deformation curves. The Sinh model predictions were compared to the SSM and CCT data. The Sinh model satisfactorily predicts the SSM data and thus the calibrated material constants provides a good estimate of rupture found in the CCT data. Calibration using SSM data reduces the number of tests needed to calibrate a model; significantly reducing costs. A single SSM test replaces numerous creep tests at different stresses.

36 MATERIALS SCIENCE↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prediction of Long-Term Strength of Thermoplastic Composites Using Time-Temperature Superposition

Accelerated tests for composite failure were investigated. Constant ramp transverse strength tests on thermoplastic composite specimens were conducted at four temperatures from 300 F to 450 F and five duration times from 0.5 sec to 24 hrs. Up to 400 F, the time-temperature-superposition method produces a master curve allowing strength at longer times to be estimated from strength tests conducted over shorter times but at higher temperatures. The shift factors derived from compliance tests applied well to the strength data. To explain why strength behaved similar to compliance, a viscoelastic fracture model was investigated based on the hypothesis that the work of fracture for crack initiation at some critical flaw remains constant with time and temperature. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with stress rate. Fracture tests using double cantilever beam specimens were conducted from 300 F to 450 F over time scales similar to the strength study. The toughness data showed a significant change with loading rate, less variation with temperature, did not form a master curve, and could not be correlated with the fracture model. Since the fracture model did not fit the fracture data, an alternative explanation based on the dilatational strain energy density was proposed. However the usefulness of this model is severely limited because it relies on a critical parameter which varies with loading rate.

Reeder, James R.↗

Graded Compression Stockings Prevent Post-spaceflight Orthostatic Hypotension

Post-spaceflight orthostatic intolerance is characterized by hypotension and presyncope in 20-30% of returning astronauts. Previous data from our laboratory suggests that this is largely a result of decreased venous return. Currently, NASA astronauts wear an anti-gravity suit (AGS) which consists of inflatable air bladders over the calves, thighs and abdomen, which are typically pressurized from 0.5 to 1.5 PSI (~27 to 78 mmHg). ISS crew members sometimes wear Russian Kentavr suits which consist of laced compression shorts and gaiters, providing ~30 mmHg nominally. While these garments are effective during reentry, there are a number of drawbacks that make them impractical for postflight use. We studied the ability of commercially available, custom fit, graded compression stockings (Jobst, 55 mmHg at ankle to 6 mmHg at top of thigh, 25 mmHg mean compression) to prevent postflight orthostatic intolerance, hypothesizing that these garments would prevent orthostatic intolerance following short duration space flight. Crew members from a single Space Shuttle flight were tilted to 80 degrees for 10 min while wearing the stockings (n=5 males) upon arrival at the clinic (~2 hrs after landing). Hemodynamic data were compared to data from all crewmembers tilted (without countermeasures) since return to flight (n=9). Two-way, repeated measures ANOVA, using the entire tilt time curve (0-10 min) show that systolic blood pressure (SBP, group effect p=0.008), stroke volume (SV, group effect p=0.003), and cardiac output (CO, group effect p=0.004) were higher in crewmembers who wore the Jobst stockings. A one-way ANOVA comparing the last minute standing also showed that SV (p=0.001) and CO (p less than 0.001) were higher and SBP tended to be higher (p=0.06) in Jobst subjects compared to controls. Control subjects had a higher rate of presyncope than Jobst subjects (3/9 vs 0/5) during the tilt on landing day. Orthostatic hypotension continues to present following spaceflight, despite fluid loading and other countermeasures. This preliminary study shows that commercially available compression stockings may ameliorate this problem. These stockings are readily available, inexpensive, and can be worn for days following landing. We have observed similar protection against orthostatic intolerance in ground-based studies of hypovolemic test subjects. Further refinements to the design and compression of the stockings are in progress.

Platts, S. H.↗

Changes in Jump-Down Performance After Space Flight: Short- and Long-Term Adaptation

INTRODUCTION Successful jump performance requires functional coordination of visual, vestibular, and somatosensory systems, which are affected by prolonged exposure to microgravity. Astronauts returning from space flight exhibit impaired ability to coordinate effective landing strategies when jumping from a platform to the ground. This study compares the jump strategies used by astronauts before and after flight, the changes to those strategies within a test session, and the recoveries in jump-down performance parameters across several postflight test sessions. These data were obtained as part of an ongoing interdisciplinary study (Functional Task Test, FTT) designed to evaluate both astronaut postflight functional performance and related physiological changes. METHODS Six astronauts from short-duration (Shuttle) and three from long-duration (International Space Station) flights performed 3 two-footed jumps from a platform 30 cm high. A force plate measured the ground reaction forces and center-of-pressure displacement from the landings. Muscle activation data were collected from the medial gastrocnemius and anterior tibialis of both legs using surface electromyography electrodes. Two load cells in the platform measured the load exerted by each foot during the takeoff phase of the jump. Data were collected in 2 preflight sessions, on landing day (Shuttle only), and 1, 6, and 30 days after flight. RESULTS AND CONCLUSION Many of the astronauts tested were unable to maintain balance on their first postflight jump landing but recovered by the third jump, showing a learning progression in which the performance improvement could be attributed to adjustments of strategy on takeoff, landing, or both. Takeoff strategy changes were evident in air time (time between takeoff and landing), which was significantly reduced after flight, and also in increased asymmetry in foot latencies on takeoff. Landing modifications were seen in changes in ground reaction force curves. The results demonstrate astronauts adaptive capabilities and full performance recovery within days after flight.

Kofman, I. S.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.

Seale, Michael D.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Optic Nerve Sheath Mechanics and Permeability in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

biomechanics↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗