Search NASA⌕ Search

SEARCH · Search NASA

Results for “load flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fast Primary Frequency Response using Coordinated DER and Flexible Loads: Framework and Residential-scale Demonstration

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (~8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Real-Time Electricity Prices to Leverage Electrical Energy Storage and Flexible Loads in a Smart Grid Environment Utilizing Machine Learning Techniques

With exposure to real-time market pricing structures, consumers would be incentivized to invest in electrical energy storage systems and smart predictive automation of their home energy systems. Smart home automation through optimizing HVAC (heating, ventilation, and air conditioning) temperature set points, along with distributed energy storage, could be utilized in the process of optimizing the operation of the electric grid. Using electricity prices as decision variables to leverage electrical energy storage and flexible loads can be a valuable tool to optimize the performance of the power grid and reduce electricity costs both on the supply and demand sides. Energy demand prediction is important for proper allocation and utilization of the available resources. Manipulating energy prices to leverage storage and flexible loads through these demand prediction models is a novel idea that needs to be studied. In this paper, different models for proactive prediction of the energy demand for an entire city using different machine learning techniques are presented and compared. The results of the machine learning techniques show that the proposed nonlinear autoregressive with exogenous inputs neural network model resulted in the most accurate predictions. These prediction models pave the way for the demand side to become an important asset for grid regulation by responding to variable price signals through battery energy storage and passive thermal energy storage using HVAC temperature set points.

25 ENERGY STORAGE↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Transactive Coordination of Flexible Loads with Energy Storage through Day-ahead Scheduling

We are motivated by the problem faced by the aggregator (market coordinator) to optimally schedule the day-ahead operation of flexible loads and energy storages through transactive coordination. The aggregator, which may be the ISO/DSO/LSE/Utility company/Microgrid controller depending on the system considered, aims to maximize social welfare of interconnected distributed energy resources (DERs) by determining the optimal hourly prices for the next operating day. Arbitrage and private objectives are incorporated to ensure participation of third-party energy storages. We show that the coordination problem can be mathematically formulated as a multi-period optimal control problem with global power flow constraints and local DER-level constraints, and propose an iterative hierarchical decentralized solution method which respects the privacy of DERs. Under proper convexity assumptions, the algorithm will converge to the optimal day-ahead market clearing prices. We illustrate the algorithm using a four-bus power system with DC power flow constraints. Results show that incorporating degradation cost decreases the energy storage's ability of peak shaving and that social welfare of the system increases when discharging and charging efficiencies increase.

Ma, Ke↗

ResStock Measure Documentation: HVAC Load Flexibility

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "HVAC Load Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart dim fuse: electrical load flexibility controller using sub-circuit voltage modulation and load sensing

Improved control of electrical power consumption is provided with “Smart Dim Fuses” (SDF) which can alter their output voltage as provided to the load circuits they are connected to. SDF units can replace conventional circuit breakers in electrical panels. The voltage control capability provided by SDF units can lead to improved control of electrical power consumption, since many loads can smoothly operate at lower power consumption when the voltage they are driven with decreases. SDF units can comply with relevant safety requirements, such as uninterrupted neutral connections between electrical mains and load circuits. SDF units can also provide a current limiting function that can substitute for the protective action of conventional circuit breakers.

Goldin, Aaron↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Thermally Stratified Compression Ignition: A new advanced low temperature combustion mode with load flexibility

We introduce a new advanced combustion mode, called Thermally Stratified Compression Ignition (TSCI), which uses direct water injection to control both the average temperature and the temperature distribution prior to ignition, thereby providing cycle-to-cycle control over the start and rate of heat release in Low Temperature Combustion (LTC). Experiments were conducted to fundamentally understand the effects of water injection on heat release in LTC. Our results show that water injection retards the start of combustion due to the latent heat of vaporization of the injected water. Furthermore, for start of water injection timings between 20 and 70 degrees before top dead center, combustion is significantly elongated compared to without water injection. The 10–90% burn duration with 6.6 and 9.0 mg of water per cycle was 77% and 146% longer than without water injection, respectively. Forced thermal stratification result from a direct water injection which reduces the heat release rate by local evaporative cooling. Finally, the load limits with and without water injection were determined experimentally. Without water injection, the load range was 2.3–3.6 bar gross IMEP. By using water injection to control heat release, the load range in TSCI was 2.3–8.4 bar gross IMEP, which is a range expansion of over 350%. These results demonstrate that direct water injection can provide significant improvements to both controllability and the range of operability of LTC, thereby resolving the major challenges associated with HCCI.

20 FOSSIL-FUELED POWER PLANTS↗