Search NASA⌕ Search

SEARCH · Search NASA

Results for “load test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

FY20 Status Report on Creep Rupture Testing to Support the Development of Alloy 709 Code Case

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. A creep test laboratory has been set up at ANL that comprises of 15 indirectly loaded test frames capable of testing ASTM-size specimens of the commercial heat of Alloy 709. The systems are equipped with high temperature furnaces capable of operation up to 1000°C in an air environment. During FY18, uniaxial ASTM-sized creep specimens were fabricated from 9 Alloy 709 plates that were processed by AOD, ESR, and ESR-homogenized routes and subsequently solution annealed at 1050, 1100, and 1150°C, and creep-rupture tests were performed at 330MPa and 600°C. The test results led to the down selection of the ESR-1100°C condition to support the code case. In FY19, 15 creep-rupture tests of the ESR-1100°C material, requiring the use of Type K thermocouples, were initiated to support the 100,000-hour Code Case. 8 tests were completed in FY19. In FY20, 6 tests were completed at the time of writing this report. In addition, 1 more test were loaded in FY20, using Type S thermocouples, and was completed. This report presents the data from the completed tests in FY20 and also the microstructural characterization of the fractured specimens. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed that in brittle fractures, the pores were narrow and thin, and elongated in the direction perpendicular to the loading direction, while in ductile fractures, the pores were much rounder. Dense precipitates were observed in all the samples, the size of which grew with test temperature. Some of the precipitates could be identified to be M23C6 based on their cuboid shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IEEE SusTech 2025 Presentation

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6\% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

42 - ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

FY25 Status Update on A709 Code Case Testing at ANL

This report provides an update on the status of the creep rupture testing on the precipitation-treated (PT) Alloy 709 samples fabricated from the first, the second and the third commercial heats, in support of the first, 100,000-hour Alloy 709 Code Case development under the American Society of Mechanical Engineers (ASME) Section III, Division 5 for high-temperature reactor construction. In Fiscal Year (FY) 25, no new tests were initiated, while 5 previously loaded tests were completed. This report presents an overview of the creep-rupture data gathered at Argonne National Laboratory (ANL) since FY21 that totaled 52 completed tests. Metallographic images showing crack morphologies in some representative samples ruptured in FY25 are also included. Key conclusions include: 1) the creep behavior of the three heats of Alloy 709 can be well described by the Larson-Miller relationship; 2) higher temperatures and larger stresses lead to shorter creep life and higher minimum creep rate; 3) Alloy 709 is overall very ductile under creep; 4) the crack morphologies near fracture surfaces are dependent on material’s grain size and test conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

36 MATERIALS SCIENCE↗

Load Composition Analysis in Support of the NERC Load Modeling Task Force. 2019-2020 Field Test of the Composite Load Model

In 2015, NERC’s reliability standards were revised to require the use of dynamic load models in transmission planning studies. To comply with the standards, planners must use load models that explicitly represent the dynamic behavior of the different constituents of load at each load bus within their transmission planning models. The most important of these constituents are motor-driven and power electronics-based loads. Collectively, these representations are known as composite load models. In anticipation of the compliance date for the new standards, NERC’s Load Modeling Task Force (LMTF), in 2019, initiated a field test of composite load models involving the regional reliability planning entities. In support of the field test, DOE and BPA researchers developed region-specific composite load models that could be assigned to each non-industrial load bus in the planning models for each of the North American interconnections. Separate models were developed for each hour of a summer peak day, a winter peak day, and a spring light-load day. This report is the technical documentation for the load composition analysis that was conducted to develop these non-industrial composite load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water-Weakening and Time-Dependent Deformation of Organic-Rich Chalks

Abstract The Ghareb Formation is a shallowly buried porous chalk in southern Israel that is being considered as a host rock for a geologic nuclear waste repository. Setup and operation of a repository will induce significant mechanical, hydrological and chemical perturbations in the Ghareb. Developing a secure repository requires careful characterization of the rock behavior to different loads. To characterize hydromechanical behavior of the Ghareb, several short- and long-term deformation experiments were conducted. Hydrostatic loading tests were conducted both dry and water-saturated, using different setups to measure elastic properties, time-dependent behavior, and permeability. A set of triaxial tests were conducted to measure the elastic properties and rock strength under differential loading at dry and water-saturated conditions. The hydrostatic tests showed the Ghareb began to deform inelastically around 12–15 MPa, a relatively low effective pressure. Long-term permeability measurements demonstrated that permeability declined with increasing effective pressure and was permanently reduced by ~ 1 order of magnitude after unloading pressure. Triaxial tests showed that water saturation significantly degrades the rock properties of the Ghareb, indicating water-weakening is a significant risk during repository operation. Time-dependent deformation is observed during hold periods of both the hydrostatic and triaxial tests, with deformation being primarily visco-plastic. The rate of deformation and permeability loss is strongly controlled by the effective pressure as well. Additionally, during holds of both hydrostatic and triaxial tests, it is observed that when water-saturated, radial strain surpassed axial strain when above effective pressures of 13–20 MPa. Thus, deformation anisotropy may occur in situ during operations even if the stress conditions are hydrostatic when above this pressure range.

58 GEOSCIENCES↗

Knock-limited combustion of ethanol-, isobutanol-, and 2-methyl-3-buten-2-ol-gasoline blends in a direct-injected spark-ignition engine

Knock-limited combustion of alcohol-gasoline fuel blends was studied in a direct-injection spark-ignition engine. Ethanol, isobutanol (2-methyl-1-propanol), and methylbutenol (2-methyl-3-buten-2-ol) were splash-blended with a blendstock for oxygenate blending (BOB) gasoline. Ethanol was blended in fractions of 10%, 20%, and 30% by volume (E10, E20, and E30). Isobutanol and methylbutenol were blended to match the oxygen weight percentage of the ethanol blends, resulting in blends of 16%, 32%, and 49% (I16, I32, and I49) isobutanol by volume and 18%, 37%, and 56% (M18, M37, and M56) methylbutenol by volume. Neat BOB and gasoline primary reference fuels (PRF) with octane numbers (ON) of 87 (PRF87) and 100 (PRF100) were included for reference. The engine was operated at fixed speed, equivalence ratio, and injection timing while knock-limited spark advance was located across a range of intake pressures. Low-level alcohol blends E10 and M18 had similar knocking behavior and appeared to be slightly more knock-resistant than I16. For mid-level blends, E20 showed further improvement over I32 while M37 showed noticeably better knock resistance, able to match the knock-resistance of PRF100 for loads above 1000 kPa gross indicated mean effective pressure (GIMEP). For high-level blends, the difference between E30 and I49 was similar to their mid-level counterparts. However, M56 showed significant improvement over E30 and I49 throughout the entire range of loads tested. M56 exceeded the knock-resistance of PRF100 for loads above 700 kPa GIMEP. The improved knock-resistance combined with the increased volumetric energy density of methylbutenol resulted in improved fuel consumption and indicated efficiency. The overall results of this study indicate that the order of knock-resistance of these three alcohols, for direct-injection operation with injection during the intake stroke, is isobutanol < ethanol < methylbutenol when compared on an equal oxygen weight basis.

33 ADVANCED PROPULSION SYSTEMS↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

Ducted Fuel Injection Provides Consistently Lower Soot Emissions in Sweep to Full-Load Conditions

Earlier studies have proven how ducted fuel injection (DFI) substantially reduces soot for low- and mid-load conditions in heavy-duty engines, without significant adverse effects on other emissions. Nevertheless, no comprehensive DFI study exists showing soot reductions at high- and full-load conditions. This study investigated DFI in a single-cylinder, 1.7-L, optical engine from low- to full-load conditions with a low-net-carbon fuel consisting of 80% renewable diesel and 20% biodiesel. Over the tested load range, DFI reduced engine-out soot by 38.1–63.1% compared to conventional diesel combustion (CDC). This soot reduction occurred without significant detrimental effects on other emission types. Thus, DFI reduced the severity of the soot–NO x tradeoff at all tested conditions. While DFI delivered considerable soot reductions in thepresent study, previous DFI studies at low- and mid-load conditions delivered larger soot reductions (>90%) compared to CDC operation at the same conditions. Therefore, the DFI configuration used here has been deemed nonoptimal (in terms of parameters such as the injector-spray and piston geometries), and several improvements are recommended for future studies with high-load DFI. Further, these improvements include employing better spray-duct alignment, a deeper piston bowl with a smaller injector umbrella angle, and a fuel injector that opens and closes faster. The study also suggests future research to make DFI ready for commercialization, such as metal-engine tests to ensure desirable DFI performance over an engine’s complete speed/load map. Overall, this study supports the continued development and commercialization of DFI to meet upcoming emissions regulations for heavy-duty vehicles. Specifically, multicylinder engine experiments and CFD simulations should be utilized to optimize the performance and clarify the full potential of DFI.

33 ADVANCED PROPULSION SYSTEMS↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formulation and calibration of two-dimensional constitutive models for composite structures based on panel tests

Steel Plate Concrete (SC) composite members have been widely adopted because of its cost-efficiency and enhanced structural behavior. While researchers have attempted to study its in-plane shear behavior in the past twenty years, very limited number of large-scale pure shear tests were performed due to the challenge of experimental set-up and the availability of facilities. In this paper, a series of uniaxial loading tests and two full-scale pure shear panel tests of SC members were reported, on which the “mechanics-based Membrane Model of SC elements (MM-SC)” is developed. The MM-SC model is based on the fixed-angle crack formulation and the smeared-crack formulation, in which the experimental-based uniaxial constitutive models are implemented, considering the local buckling of faceplate, the tension stiffening of steel plate, the strength degradation of cracked concrete and the confinement effect of concrete. The proposed MM-SC model is subsequently incorporated into the object-oriented software OpenSEES. Finally, the simulation results of proposed model well predict the SC test observations in terms of critical branch points and structural behaviors, including initial stiffness, cracking strength, post-crack stiffness, yield strength, maximum strength, and failure modes.

42 ENGINEERING↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Bio-fuel effects and seasonal fuel property variations related to abnormal combustion occurrences observed in the field

Since 2015, the automotive industry has regularly observed sharp increases in customer complaints of poor driveability and increased warranty claims during the months of September and October. These persistent seasonal complaint increases have been tracked to occur from increased abnormal combustion events that coincide with the seasonal transition from summer to winter fuel volatility, beginning on September 15th annually. The Reid Vapor Pressure (RVP) of gasoline during this seasonal transition has been found to be the primary property attributed to this annual issue. It’s hypothesized that an increase in volatile butanes and pentanes from advanced petroleum recovery techniques and hydrofracking production has hastened the transition from summer to winter fuel volatility in the marketplace, rather than the gradual increase of the RVP over time as historically intended. At worst, mid-winter fuel, with an RVP ranging from 12 to 16 psi, depending on location in the U.S., enters the market while ambient temperatures can still be above average for the winter season. This combination of high volatility fuel with unseasonably warm weather will increase fuel system flash boiling, injector spray cavitation, and spray collapse inside the engine’s combustion chamber, ultimately linking fuel property variations to abnormal engine combustion processes. This CRADA program will investigate these known knowledge gaps by coupling with two national laboratories, Oak Ridge National Laboratory, and the National Renewable Energy Laboratory to employ both unique tools and expertise throughout the industry to provide the insight, knowledge, and data critical to understand the observed interactions. Overall findings of this work are that fuel wall retention increased SPI proportionally, and fuels with an increased distillation (i.e. energy fraction) above the wall temperature increased fuel retention. Likewise fuels with increased enthalpy of vaporization (HoV) increased fuel retention proportional to the temperature reduction from the HoV (~13K reduction in this work). Thus, fuel with increased HoV and increased fuel distillation above the linear temperature also exhibited increased SPI rates. Fuel with high RVP did exhibit increased fuel spray collapse form spray imaging measurements, but in SPI testing the high volatility of these fuels at the tested conditions did not necessarily increase SPI rates despite exhibiting increased spray collapse in injector imaging and increased spray-wall impingement measured in fired engine testing. It was also found that spray imaging showed collapse was possible at throttled conditions, but this was not relevant to high boost pressures relevant to SPI conditions, however, under transient load and or speed encountered in real-world operation fuel spray collapse could affect fuel retention and real-world SPI that were not probed in the automated high load test sequence of this work.

09 BIOMASS FUELS↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗