Search NASA⌕ Search

SEARCH · Search NASA

Results for “local measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The relation of local measures of Hubble's constant to its global value

The distributions of fractional deviations of local values form global H0 that observers with perfect distance data would find if they surveyed specified volumes of the universe are examined here using new very large scale calculations of cold dark matter (CDM) and primordial isocurvature baryonic (PIB) scenarios for the origin of structure. It is found that the expected deviations due to large-scale motions are larger than quoted observational errors unless very large volumes are surveyed. Even perfect sampling and distances of all galaxies within a sphere extending out to the distances of the Virgo and Coma clusters would leave 45 percent and 3 percent rms uncertainties, respectively, in the global value of H0 in the CDM model. It is shown that the local versus global error in an H0 determination can be roughly estimated by the angular variance seen over the sky in the expansion rate, and that a very rough correction from the local to the global H0 value can be derived.

Turner, Edwin L.↗

Measuring local primordial non-Gaussianity from the clustering of DESI DR1 LRGs and QSOs

We report the first measurement of primordial non-Gaussianity (PNG), parameterized by $f_{\mathrm{NL}}$, in the configuration space two-point correlation function (2pcf). We employ simulation based modeling and a novel approach for the mitigation of imaging systematics. We apply this method to samples of luminous red galaxies (LRG) and quasars (QSO) observed by the Dark Energy Spectroscopic Instrument (DESI) during the first year of its observations (DR1). The observed 68% CL interval on $f_{\mathrm{NL}}$ is $-3^{+22}_{-21}$ using LRGs, and $ 0^{+17}_{-16}$ using QSOs. The joint measurement yields $f_{\mathrm{NL}} = -3^{+12}_{-12}$ at $\ [68\%]$ CL. Our pipeline imposes a Gaussian prior on the value of $p$ (which defines the PNG bias via the Universality relation), with $p_{\rm LRG} = 1.0 \pm 0.1$ and $p_{\rm QSO} = 1.6\pm 0.1$. The observed constraining power of DESI tracers significantly exceeds that of previous large-scale structure (LSS) surveys, and encouragingly, approaches the sensitivity of CMB probes of PNG.

Brown, Z. [Kansas State U.]↗

Phased Array Noise Source Localization Measurements of an F404 Nozzle Plume at Both Full and Model Scale

A 48-microphone planar phased array system was used to acquire jet noise source localization data on both a full-scale F404-GE-F400 engine and on a 1/4th scale model of a F400 series nozzle. The full-scale engine test data show the location of the dominant noise sources in the jet plume as a function of frequency for the engine in both baseline (no chevron) and chevron configurations. Data are presented for the engine operating both with and without afterburners. Based on lessons learned during this test, a set of recommendations are provided regarding how the phased array measurement system could be modified in order to obtain more useful acoustic source localization data on high-performance military engines in the future. The data obtained on the 1/4th scale F400 series nozzle provide useful insights regarding the full-scale engine jet noise source mechanisms, and document some of the differences associated with testing at model-scale versus fullscale.

Podboy, Gary G.↗

Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine

A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.

Podboy, Gary G.↗

Local measurement of bulk thermal diffusivity using photothermal radiometry

Here, an experimental methodology using photothermal radiometry is developed for the accurate measurement of bulk thermal diffusivity of nuclear fuels and materials irradiated to high doses. Under these conditions, nuclear fuels, such as uranium oxide, and moderator materials, such as graphite, become friable, which requires characterization techniques that can accommodate irregularly shaped fragments. Photothermal radiometry, a good candidate for this application, involves locally heating a sample by using a laser and measuring the temperature field by monitoring blackbody radiation. The interaction volume for this study, less than a millimeter, is carefully chosen to sample a statistically significant number of large-scale structural features, such as pores and gas filled bubbles, and is small enough that the sample fragments can be treated as a thermal half-space. The thermal diffusivity standards considered in this study cover a range of thermal diffusivities representative of both fresh and spent nuclear fuels. We also consider a sample having a porous microstructure representative of large-scale structures found in materials irradiated to high doses. Our measurement methodology circumvents complex thermal wave models that address optical diffraction, nonlinear transfer function associated with blackbody radiation, and finite sample size effects. Consequently, the large measurement uncertainty associated with modeling these effects can be avoided. While the emphasis here is on nuclear fuels and materials, this measurement approach is well suited to measure thermal transport in a variety of technologically important materials associated with advanced synthesis techniques. Examples range from small, exotic single crystals grown using hydrothermal growth techniques to additively manufactured components having complex geometries.

36 MATERIALS SCIENCE↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Detection of long-range entanglement in gapped quantum spin liquids by local measurements

Topological order, reflected in long-range patterns of entanglement, is quantified by the topological entanglement entropy γ. We show that for gapped quantum spin liquids it is possible to extract γ using two-spin local correlators. We demonstrate our method for the gapped Z 2 Kitaev spin liquid on a honeycomb lattice with anisotropic interactions. We show that the γ = ln⁡2 for Z 2 topological order can be simply extracted from local two-spin correlators across two different bonds that involve only Majorana fermions, with an accuracy comparable to or higher than the Kitaev-Preskill construction. This implies that even though the ground state can be factorized into the product of Majorana and gauge sectors, the different superselection sectors of Z 2 gauge theory determined by global Wilson loop operators can be reflected locally in the Majorana sector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of theoretical and flight-measured local flow aerodynamics for a low-aspect-ratio fin

Flight test and theoretical aerodynamic data were obtained for a flight test fixture mounted on the underside of an F-104G aircraft. The theoretical data were generated using two codes: a two-dimensional transonic code called code H, and a three-dimensional subsonic and supersonic code called wing-body. Pressure distributions generated by the codes for the flight test fixture, as well as compared with the flight-measured data. The two-dimensional code pressure distributions compared well except at the minimum pressure point and the trailing edge. Shock locations compared well except at high transonic speeds. However, the two-dimensional code did not adequately predict the displacement thickness of the flight test fixture. The three-dimensional code pressure distributions compared well except at the trailing edge of the flight test fixture.

Johnson, J. Blair↗

Plasma Imaging, LOcal Measurement, and Tomographic Experiment (PILOT): A Mission Concept for Transformational Multi-Scale Observations of Mass and Energy Flow Dynamics in Earth’s Magnetosphere

We currently do not understand the fundamental physical processes that govern mass and energy flow through the Earth’s magnetosphere. Knowledge of these processes is critical to understanding the mass loss rate of Earth’s atmosphere, as well as for determining the role that a planetary magnetic field plays in atmospheric retention, and therefore habitability, for Earth-like planets beyond the solar system. Mass and energy flow processes are challenging to determine at Earth in part because Earth’s planetary magnetic field creates a complex “system of systems” composed of interdependent plasma populations and overlapping spatial regions that perpetually exchange mass and energy across a broad range of temporal and spatial scales. Further, the primary mass carrier in the magnetosphere is cold plasma (as cold as ~0.1 eV), which is invisible to many space-borne instruments that operate in the inner magnetosphere. The Plasma Imaging LOcal and Tomographic experiment (PILOT) mission concept, described here, provides the transformational multi-scale observations required to answer fundamental open questions about mass and energy flow dynamics in the Earth’s magnetosphere. PILOT uses a constellation of spacecraft to make radio tomographic, remote sensing, and in-situ measurements simultaneously, fully capturing cold plasma mass dynamics and its impact on magnetospheric systems over an unprecedented range of spatial and temporal scales. This article details the scientific motivation for the PILOT mission concept as well as a potential mission implementation.

79 ASTRONOMY AND ASTROPHYSICS↗

Inferring Quantum Network Topology Using Local Measurements

Statistical correlations that can be generated across the nodes in a quantum network depend crucially on its topology. However, this topological information might not be known a priori, or it may need to be verified. In this paper, we propose an efficient protocol for distinguishing and inferring the topology of a quantum network. We leverage entropic quantities-namely, the von Neumann entropy and the measured mutual information-as well as measurement covariance to uniquely characterize the topology. We show that the entropic quantities are sufficient to distinguish two networks that prepare GHZ states. Moreover, if qubit measurements are available, both entropic quantities and covariance can be used to infer the network topology without state-preparation assumptions. We show that the protocol can be entirely robust to noise and can be implemented via quantum variational optimization. Numerical experiments on both classical simulators and quantum hardware show that covariance is generally more reliable for accurately and efficiently inferring the topology, whereas entropy-based methods are often better at identifying the absence of entanglement in the low-shot regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot local measurement of terahertz correlated second harmonic generation in laser air plasma filaments

We present a single-shot detection method of terahertz correlated second harmonic generation in plasma-based sources by directly mixing an optical probe into femtosecond laser-induced plasma filaments in air. Furthermore, the single-shot second harmonic trace is obtained by measuring a second harmonic generation on a conventional CCD with a spatiotemporally distorted probe beam. The system shows a spectrometer resolution of 22 fs/pixel on the CCD and a true resolution on the order of the probe pulse duration. With considerable THz peak electric field strength, this formalism can open the door to single-shot THz detection without bandwidth limitations.

47 OTHER INSTRUMENTATION↗