Search NASA⌕ Search

SEARCH · Search NASA

Results for “lock-in”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Compact carbon monoxide sensor utilizing a confocal optical cavity.

The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

Scott, B.↗

Contributions to the problem of piezoelectric accelerometer calibration

After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

Jakab, I.↗

Excess junction current of silicon solar cells

The current-voltage characteristics of n(plus)-p silicon solar cells with 0.1, 1.0, 2.0, and 10 ohm-cm p-type base materials have been examined in detail. In addition to the usual I-V measurements, we have studied the temperature dependence of the slope of the I-V curve at the origin by the lock-in technique. The excess junction current coefficient (Iq) deduced from the slope at the origin depends on the square root of the intrinsic carrier concentration. The Iq obtained from the I-V curve fitting over the entire forward bias region at various temperatures shows the same temperature dependence. This result, in addition to the presence of an aging effect, suggest that the surface channel effect is the dominant cause of the excess junction current.

Wang, E. Y.↗

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

Investigation of light scattering as a technique for detecting discrete soot particles in a luminous flame

The practicability of using a classical light-scattering technique, involving comparison of angular scattering intensity patterns with theoretically determined Mie and Rayleight patterns, to detect discrete soot particles (diameter less than 50 nm) in premixed propane/air and propane/oxygen-helium flames is considered. The experimental apparatus employed in this investigation included a laser light source, a flat-flame burner, specially coated optics, a cooled photomultiplier detector, and a lock-in voltmeter readout. Although large, agglomerated soot particles were detected and sized, it was not possible to detect small, discrete particles. The limiting factor appears to be background scattering by the system's optics.

Source record↗

Laser optogalvanic spectroscopy of molecules

In laser optogalvanic (LOG) spectroscopy, a tunable laser is used to probe the spectral characteristics of atomic or molecular species within an electrical discharge in a low pressure gas. Optogalvanic signals arise when the impedance of the discharge changes in response to the absorption of laser radiation. The technique may, therefore, be referred to as impedance spectroscopy. This change in impedance may be monitored as a change in the voltage across the discharge tube. LOG spectra are recorded by scanning the wavelength of a chopped CW dye laser while monitoring the discharge voltage with a lock-in amplifier. LOG signals are obtained if the laser wavelength matches a transition in a species present in the discharge (or flame), and if the absorption of energy in the laser beam alters the impedance of the discharge. Infrared LOG spectroscopy of molecules has been demonstrated and may prove to be the most productive application in the field of optogalvanic techniques.

Webster, C. R.↗

Measurement of the J = 0-1 rotational transitions of three isotopes of ArD(+)

The rotational transitions of all three isotopic species of ArD(+) in samples containing the Ar isotopes in their natural abundances have been measured by means of millimeter and submillimeter techniques that employ a magnetically enhanced abnormal glow discharge. All three transition frequency measurements were made from digitally averaged signals detected through a lock-in amplifier with a 10-msec time constant. The Ar-4OD(+) transition was easily visible in real time on an oscilloscope with SNR of about 15. It is noted that the observed transition of Ar-38D(+) is more than five orders of magnitude weaker than that due to HCO(+).

Bowman, W. C.↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Portable remote laser sensor for methane leak detection

A portable laser system for remote detection of methane gas leaks and concentrations is disclosed. The system transmitter includes first and second lasers, tuned respectively to a wavelength coincident with a strong absorption line of methane and a reference wavelength which is weakly absorbed by methane gas. The system receiver includes a spherical mirror for collecting the reflected laser radiation and focusing the collected radiation through a narrowband optical filter onto an optial detector. The filter is tuned to the wavelength of the two lasers, and rejects background noise. The output of the optical detector is processed by a lock-in detector synchronized to the chopper, and which measures the difference between the first wavelength signal and the reference wavelength signal.

Grant, W. B.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Carbon monoxide production in low energy oxygen ion bombardment of pyrolytic graphite and Kapton surfaces

The results of an investigtion of the interaction of low energy oxygen ions with pyrolytic graphite and Kapton surface are reported. CO molecules emitted from the surface as a result of the ion bombardment were detected by a mass spectrometer. Because the ion-induced signals were small compared to that arising from the CO background pressure in the vacuum system, the ion beam was modulated and the modulated component of the CO signal measured with a lock-in amplifier. The quantum yield (CO molecules emitted per incident oxygen ion) for graphite rose from 1.9 at 4.5 eV ion energy to 6.6 at 465 eV. Comparable yields were obtained for Kapton. The large size of the yields suggests contributions to the reaction process from the background O2 molecules in the vacuum system.

Horton, C. C.↗

Response of a Fabry-Perot cavity to phase modulated light

A solution to the lock-in detection method, which is valid for arbitrary values of the modulation frequency, is described. The theory for determining frequency modulation of a single frequency laser is presented. The theoretical predictions for the optimum modulation index are compared to experimental solutions for the quasi-static regime. Signal line shapes for first, second, and third harmonic generations are derived and examined. It is noted that there is good correlation between experimental and quasi-static theory data for the relation between small modulation frequency and resonance linewidth.

Hils, Dieter↗

Chopping-Wheel Optical Attenuator

Star-shaped rotating chopping wheel provides adjustable time-averaged attenuation of narrow beam of light without changing length of optical path or spectral distribution of light. Duty cycle or attenuation factor of chopped beam controlled by adjusting radius at which beam intersects wheel. Attenuation factor independent of wavelength. Useful in systems in which chopping frequency above frequency-response limits of photodetectors receiving chopped light. Used in systems using synchronous detection with lock-in amplifiers.

Leviton, Douglas B.↗

Steady-state evoked potentials possibilities for mental-state estimation

The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

Junker, Andrew M.↗

Integrated Solar Disk Oscillation Measurements Using the Magneto-Optical Filter: Tests with a Two Station Network

The magneto-optical filter (MOF) was used to get high and intermediate l-modes of solar oscillations. For very low l-modes the imaging capability of the MOF is still attractive since it allows a pixel by pixel intensity normalization. However, a crude attempt to get very low l power spectra from Dopplergrams obtained at Mt. Wilson gave noisy results. This means that a careful analysis of all the factors potentially affecting high resolution Dopplergrams should be accomplished. In order to better investigate this problem, a nonimaging channel using the lock-in amplifier technique was considered. Two systems are now operational, one at JPL and the other at University of Rome. Observations in progress are used to discuss the MOF stability, the noise level, and the possible application in asteroseismology.

Cacciani, Alessandro↗

Frequency Synthesizer For Tracking Filter

Digital frequency-synthesizing subsystem generates trains of pulses, free of jitter, for use as frequency-control signals in tracking filters. Part of assembly of electronic equipment used to measure vibrations in bearings in rotating machinery. Designed to meet requirements for tracking narrow-band cage-rotation and ball-pass components of vibrations, as discussed in "Frequency-Tracking Error Detector" (MFS-29538) and "Ball-Pass Cage-Modulation Detector" (MFS-29539). Synthesizer includes preset counter, output of which controls signal for ball-pass filter. Input to this preset counter updated every 2 microseconds: responds almost immediately, effectively eliminating relatively long response time (lock-in time) and phase jitter.

Randall, Richard L.↗

Modeling of vortex-induced oscillations based on indicial response approach

The indicial response approach, a modeling approach originally used for studying nonlinear problems in flight dynamics is applied to the study of vortex-induced oscillations phenomena. The indicial response of the velocity field is derived for the problem studied with emphasis on physical postulates involved. A full account of fluid dynamics effects is taken by considering the incompressible Navier-Stokes equations. The theory is applied to the particular case of flow past a cylinder in periodically forced motion to derive some salient features. The indicial response approach is shown to be equivalent to a currently popular approach based on the use of the amplitude equation. Jump and hysteresis phenomena that experiments indicate occur within the lock-in regime (where the velocity field oscillates at the forcing frequency) are captured by the approach.

Truong, Khiem Van↗

Preparation of a second station for the measurement of solar oscillations of low degree 'l'

An observing station to detect low-degree global solar oscillations is already operational at the Jet Propulsion Laboratory. A second station for continuative measurements of such oscillations has recently been installed and successfully tested in Rome. The high transmission and stability of the magneto-optical filter (MOF) coupled with the lock-in amplifier technique allow analog and real-time detection of oscillation modes with a noise level of only a few cm/s. Observing runs and estimates of the signal-to-noise ratio are shown in time and frequency domains. Routine observations will establish whether the MOF sensitivity and stability are suitable for the detection of stellar oscillations.

Cacciani, A.↗