Search NASA⌕ Search

SEARCH · Search NASA

Results for “low-temperature operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Transient shutdown analysis of low-temperature thermal diodes

The various thermal diodes available for use in cryogenic systems are described. Two diode types, liquid-trap and liquid-blockage diodes, were considered to be the most attractive, and thermal models were constructed to predict their behavior in the reverse mode. The diodes, which are of similar size and throughput, were also examined experimentally in a parallel test setup under nominally identical conditions. Their characteristics were ascertained in terms of forward-mode and reverse-mode conductances, shutdown times and energies, and recovery to forward-mode operation with ethane as the working fluid in the temperature range 170 K to 220 K. Results show that the liquid-blockage diode is the quicker of the two diodes to shut down from the forward mode (8 min as opposed to 10 min). However, the liquid-blockage diode has a larger reverse-mode conductance which results in a greater overall evaporator temperature rise. The importance of the relative size and heat inputs to the condenser/reservoir configuration of the liquid-blockage diode and the evaporator trap configuration for the liquid-trap diode are demonstrated. Also included are data which show the susceptibility of the diodes to recovery to forward-mode operation. Guidelines for the choice of a particular diode for an actual application are given.

Williams, R. J.↗

Design of a one-year lifetime, spaceborne superfluid helium dewar

The Infrared Astronomical Satellite is an Explorer Mission and a joint venture of the Netherlands, the United Kingdom, and the United States scheduled for launch into earth orbit in 1981. The cryogenic system is a major part of the satellite; it incorporated many unique and state-of-the-art design features to satisfy the requirements of a one-year orbital lifetime, a focal plane temperature less than 4K, minimal launch weight, and zero-gravity operation. The 60-centimeter diameter telescope is contained within a superfluid helium dewar having a capacity of 540 liters. The telescope aperture cover employs an independent cryogenic system containing a 54-liter supercritical helium tank. The aperture cover, which is ejected two weeks after launch, protects the telescope from contamination and provides the low-temperature background needed to perform focal plane health checks. Design and predicted performance of the cryogenic systems are discussed in detail.

Hopkins, R. A.↗

Annual Conference on Nuclear and Space Radiation Effects, 14th, College of William and Mary, Williamsburg, Va., July 12-15, 1977, Proceedings

Topics related to processing and hardness assurance are considered, taking into account the radiation hardening of CMOS technologies, technological advances in the manufacture of radiation-hardened CMOS integrated circuits, CMOS hardness assurance through process controls and optimized design procedures, the application of operational amplifiers to hardened systems, a hard off-the-shelf SG1524 pulse width modulator, and the gamma-induced voltage breakdown anomaly in a Schottky diode. Basic mechanisms are examined, giving attention to chemical and structural aspects of the irradiation behavior of SiO2 films on silicon, experimental observations of the chemistry of the SiO2/Si interface, leakage current phenomena in irradiated SOS devices, the avalanche injection of holes into SiO2, the low-temperature radiation response of Al2O3 gate insulators, and neutron damage mechanisms in silicon at 10 K. Other subjects discussed are related to radiation effects in devices and circuits, space radiation effects, and aspects of simulation, energy deposition, and dosimetry.

Stahl, R. H.↗

Regeneration experiments below 10K in a regenerative-cycle cryocooler

At temperatures below 10K, regenerative cycle cryocoolers are limited by regeneration losses in the helium working fluid which result from the decreasing heat capacity of the regenerating material and the increasing density of helium. Experiments examining several approaches to improving the low-temperature regeneration in a four-stage regenerative cycle cooler constructed primarily of fiberglass materials are discussed. Using an interchangeable fourth stage, the experiments included configurations with multiple regeneration passages, and a static helium volume for increased heat capacity. Experiments using helium-3 as the working fluid and a Malone stage are planned. Results indicate that, using these techniques, it should be possible to construct a regenerative cycle cooler which will operate below 6K.

Sager, R. E.↗

Anode materials for electrochemical waste destruction

Electrochemical Oxidation (ECO) offers promise as a low-temperature, atmospheric pressure method for safe destruction of hazardous organic chemical wastes in water. Anode materials tend to suffer corrosion in the intensely oxidizing environment of the ECO cell. There is a need for cheaper, more resistant materials. In this experiment, a system is described for testing anode materials, with examples of several common anodes such as stainless steel, graphite, and platinized titanium. The ECO system is simple and safe to operate and the experiment can easily be expanded in scope to study the effects of different solutions, temperatures, and organic materials.

Molton, Peter M.↗

Normal incidence reflectance of ion beam deposited SiC films in the EUV

Results are presented from an experimental investigation of the normal-incidence reflectance at 58.4, 92.0, and 121.6 nm wavelength of 30- and 80-nm-thick SiC films produced by ion-beam deposition on unheated 5 x 5-cm microscope slides. The films were deposited in the 2-m evaporator described by Bradford et al. (1969) with chamber base pressure 1 microtorr, operating pressure 40 microtorr, and a 50-62-mA 750-eV Ar ion beam; the reflectance measurements were obtained in the reflector-monochromator system described by Osantowski (1974). Reflectances of over 30 percent were found at 92 and 121.6 nm, almost equal to those of polished CVD films of SiC and degrading only slightly after aging for 4 months. It is suggested that ion-beam deposition may be the best low-temperature technique for coating EUV optics for space astronomy.

Keski-Kuha, Ritva A. M.↗

Small scale demand type neon liquefaction plant

Low-temperature measurement of the thermal conductivity of insulating materials is generally made using a boil-off calorimetry technique involving liquid hydrogen (LH2). Liquid neon (LNe) has nearly the same normal boiling point as LH2, but has a much larger heat of vaporization, allowing extended run times. The main drawback of using LNe has been its excessive cost; $170.00 versus $1.50/l for LH2 (1989 prices). A neon liquefaction plant has been designed and constructed to capture, purify, and refrigerate the neon boil-off from calorimetry experiments. Recycling the neon reduces operating costs to approximately $20/l. The system consists of a purification section, a heat exchanger, LNe and LH2 storage dewars, and a fully automated control system. After purification, neon is liquified in the heat exchanger by LH2 flowing countercurrently through stainless steel cooling coils. Hydrogen flow is automatically adjusted to keep the neon at its normal saturation temperature, 27 K. The liquid neon is then stored in a dewar placed directly below the heat exchanger.

Dube, W. P.↗

Shutoff and throttling valve

Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

Hays, L. G.↗

Influence of low temperatures of friction and wear

A brief review of studies on low-temperature friction are briefly reviewed. A facility and technique for studying friction both in air and in vacuum at temperatures of +20 and -190 C is described. Results of a wear study of structural steels operating together with chromium steel are presented. It is shown that reduction of the test temperature in vacuum leads in certain cases to marked increase of the wear magnitude and friction coefficient. This is associated not only with the general change of the mechanical properties of the materials but also with the influence of temperature reduction on the hardening and structural formation taking place in the surface layers during friction.

Udovenko, V. F.↗

Design guide for helicopter transmission seals

A detailed approach for the selection and design of seals for helicopter transmissions is presented. There are two major types of seals presently being used and they are lip type seals and mechanical type seals. Lip type seals can be divided in conventional lip seals and hydrodynamic lip seals. Conventional lip seals can be used for slow-speed, low-pressure, low-temperature sealing. Hydrodynamic lip seals although they are as pressure and temperature limited as conventional lip seals, can operate at a higher speed. Mechanical types seals are comprised of face seals and circumferential seals. Face seals are capable of high speed, high pressure, and high temperature. Circumferential seals can be used in high-speed and high-temperature applications, but will leak excessively at moderate pressures. The performance goals of transmission seals are a life that is at least equal to the scheduled overhaul interval of the gearbox component and a leakage rate of near zero.

Hayden, T. S.↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 3: Combustors, furnaces and low-BTU gasifiers

Information is presented on the design, performance, operating characteristics, cost, and development status of coal preparation equipment, combustion equipment, furnaces, low-Btu gasification processes, low-temperature carbonization processes, desulfurization processes, and pollution particulate removal equipment. The information was compiled for use by the various cycle concept leaders in determining the performance, capital costs, energy costs, and natural resource requirements of each of their system configurations.

Hamm, J. R.↗

Small monopropellant thruster contamination measurement in a high-vacuum low-temperature facility

The contamination that results from the exhaust plume of small thrusters used for attitude control maneuvers can pose severe problems for long-life satellite systems. In order to assess this type of contamination problem, analytical and experimental techniques must be developed. Mass deposition rate measurements of a representative 0.44-N thrust hydrazine thruster were made in a space simulation chamber using five appropriately placed variable-temperature quartz crystal microbalances. The mass deposition rates within the thruster plume were measured while operating the thruster over a wide range of operating parameters, including duty cycles, catalyst bed start temperatures, propellant water variation, as well as thruster aging effects. The contamination measurements were made over a temperature range of 144 to 256 K for all duty cycles. In addition, the nominal duty cycle of 100 msec on and 10 sec off was run at a temperature of 106 K. These data will make possible better prediction of deposition rates of contaminants from thrusters used in satellite systems.

Passamaneck, R. S.↗

The suppression of low-temperature intergranular brittleness in ferritic Fe-Mn alloys

A method for obtaining cryogenic toughness in an Fe-12Mn-0.2Ti alloy by a controlled cooling technique is presented. The intergranular fracture surface of the quenched alloy, using an AES, revealed no significant difference from that obtained by the bulk transgranular fracture surface, indicating the absence of large-scale grain boundary segregation during the austenitizing treatment. Attention is given to the step cooling method, using a furnace at temperatures of 100 to 120 C, followed by fast cooling to ambient temperature, which in turn produces a high-impact toughness without intergranular brittleness. It is concluded that the sources of brittle intergranular fracture in the alloy are both chemical, operating in martensitic structure, and nonchemical, active during quenching from the austenitizing treatment.

Hwang, S. K.↗

Electron temperature measurements using a 12-channel array probe

The most common technique for determining the mean kinetic energy of electrons in low-temperature plasmas utilizes the so-called Langmuir probe. The present investigation is concerned with the study of the electron temperature in a pulsed high-beta plasma as a function of time by means of a miniature array of 12 planar Langmuir probes. By using a probe with many individually collecting surfaces, each biased at a different fixed voltage, an approximation to the true probe characteristic is obtained when monitoring the collected currents for each independent subprobe. The employed method, by using many points, provides enough information to reconstruct the entire I-V curve. Attention is given to the principle of operation of the new probe, calibration, accuracy, time resolution, and applications of the new method. By employing two probes it is possible to perform correlation measurements to study heat flow and temperature fluctuations.

Wild, N.↗

Low-temperature heat pipe experiment package (HEPP) for LDEF (S1001)

The principal objectives of the experiment are to determine zero-g start-up performance for conventional and diode low temperature heat pipes, to evaluate heat pipe performance in zero-g for an extended period of time, to determine zero-g transport capability of each heat pipe, and to determine diode operation, including forward conductance, turndown ratio, and transient behavior. Two heat pipes, a fixed conductance transporter heat pipe and a thermal diode heat pipe, are coupled with a radiant cooler system. Both pipes are charged with ethane. Also integrated with the radiator is a phase change material (PCM) canister which provides temperature stability during transport tests. N-heptane, which has a melting/freezing point of 182 K, is used as the PCM. The high heat capacity (28 W-hr of latent heat) provided by the canister permits high power heat pipe testing at constant temperature.

Mcintosh, R., Jr.↗

Fused silica mirror evaluation for the Shuttle Infrared Telescope Facility (SIRTF)

The SIRTF optics are intended for operation at 20 K (or less); it will be extremely inconvenient, expensive, and time consuming if it becomes necessary to accomplish all of the optical element testing, assembly, and alignment at comparable temperatures. The thermal strain behavior, including potential anisotropies and inhomogeneities, of a mirror substrate between room temperature and 20 K thus becomes a major factor in the selection of the substrate material, structural configuration, and joining methods for lightweight structures. With support from Space Projects, NASA Ames Research Center, an optical figure evaluation of a 0.65-meter, lightweight, fused silica mirror at a low-temperature goal of 20 K is being conducted. The design details of a thermal shroud, provisions for extracting heat from the low-conductivity mirror, and wavefront error sources other than the mirror surface are discussed and preliminary test results presented.

Barnes, W. P., Jr.↗

Low temperature safety of lithium-thionyl chloride cells

The use of lithium thionyl chloride cells for low-temperature applications is presently restricted because of their unsafe behavior. An attempt is made in the present investigation to identify the safe/unsafe low temperature operating conditions and to understand the low temperature cell chemistry responsible for the unsafe behavior. Cells subjected to extended reversal at low rate and -40 C were found to explode upon warm-up. Lithium was found to deposit on the carbon cathodes during reversal. Warming up to room temperature may be accelerating the lithium corrosion in the electrolyte. This may be one of the reasons for the cell thermal runaway.

Subbarao, S.↗

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗