Search NASA⌕ Search

SEARCH · Search NASA

Results for “mCA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Giant Magnetic and Optical Anisotropy in Cerium-Substituted M-Type Strontium Hexaferrite Driven by $4f$ Electrons

By performing density-functional calculations, we find a giant magnetocrystalline anisotropy (MCA) constant in abundant element cerium $\mathrm{Ce}$ substituted M-type hexaferrite, in the energetically favorable strontium site, assisted by a quantum confined electron transfer from $\mathrm{Ce}$ to a specific iron $\mathrm{2a}$ site. Remarkably, the calculated electronic structure shows that the electron transfer leads to the formation of $\mathrm{Ce}^{3+}$ and $\mathrm{Fe}^{2+}$ at the $\mathrm{2a}$ site producing an occupied $\mathrm{Ce}$$(4f^1)$ state below the Fermi level that adds a significant contribution to MCA and magnetic moment. A half $\mathrm{Ce}$ substitution forms a metallic state, while a full substitution retains the semiconducting state of the strontium hexaferrite (host). In the latter, the band gap is reduced due to the formation of charge-transferred states in the gap region of the host. The optical absorption coefficient shows an enhanced anisotropy between light polarization in parallel and perpendicular directions. Calculated formation energies, including the analysis of probable competing phases, and elastic constants confirm that both compositions are chemically and mechanically stable. With successful synthesis, the $\mathrm{Ce}$ hexaferrite can be an alternative high-performing critical-element-free permanent magnet material adapted for use in devices such as automotive traction drive motors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Low Frequency Repetitive Transcranial Magnetic Stimulation (rTMS) Combined with Hyperbaric Oxygen (HBO) on Awakening of Coma Patients with Traumatic Brain Injury

Coma caused by craniocerebral injury is a common condition of neurosurgical acute injury. There is no specific method to promote awakening in a clinic. Early comprehensive treatment may be helpful to patients. The common methods are hyperbaric oxygen (HBO) and low-frequency repetitive transcranial magnetic stimulation (rTMS). However, the application effect and mechanism of rTMS combined with HBO on coma patients with traumatic brain injury need to be further studied. The brain stem auditory evoked potential (BAEP) is examined by the Kennedy coma recovery scale (CRS-R), the recovery of brain function and the state of consciousness are evaluated, and the therapeutic effect is evaluated by the Glasgow Coma Scale (GCS). Cerebrospinal fluid NE level, MCA blood flow velocity, and left brainstem and right brainstem auditory evoked potential are used to evaluate brain rehabilitation. RTMS combined with HBO could shorten the wake-up time, improve the wake-up rate, improve the GCS score and CRS-R score, shorten the brain wave latency time of the left and right brainstem, increase the NE level of cerebrospinal fluid, and decrease the blood flow velocity of MCA. RTMS combines with HBO can improve the nerve excitability of brain cells, reduce the disturbance of consciousness, promote the functional recovery of brain injury, and has a certain role in promoting the awakening of patients with traumatic brain injury coma.

Liu, Mei↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of B 2 O 3 on the Growth, Structural, and Magneto-Optical Properties of Yttrium Iron Garnet Single-Crystal Fibers

This study explores the fabrication of yttrium iron garnet (YIG) single crystal fibers using the laser heated pedestal growth (LHPG) method with the experimental addition of B 2 O 3 . The incorporation of B 2 O 3 facilitates the fiber fabrication process by lowering the required growth temperatures and likely modifying melt viscosity behavior, consistent with the established fluxing behavior of B2O3 and the comparative viscosity trend observed in the TMA−VFT analysis, thereby improving process efficiency while maintaining fiber quality. Structural characterization using EBSD and SC-XRD reveals a transition from polycrystalline to single-crystal behavior, with improved alignment along the [111] direction without altering the garnet structure. Magnetic measurements show increases in saturation magnetization in B 2 O 3 -assisted fibers. Three-dimensional anisotropy energy modeling, based on EBSD-derived Euler angles, indicates that the enhanced crystallinity and orientation contribute to reorientation of MCA energy distribution due to improved crystallographic alignment. Faraday rotation measurements show that the B 2 O 3 -assisted sample exhibits a rotation angle closer to reported values for high-quality YIG, suggesting improved phase purity and crystallographic quality. These findings demonstrate that B 2 O 3 -assisted LHPG growth is a scalable and nontoxic approach to producing high-performance YIG fibers for integrated photonic and magnetic field sensing applications.

Crystal structure↗

System-Level Optimization to Improve Biofuel Potential via Genetic Engineering and Hydrothermal Liquefaction

The economic success of biofuels and bioproducts depends on system-level optimization including biomass production and conversion. Hydrothermal liquefaction (HTL) can convert wet biomass such as microalgae into a biofuel intermediate (BFI) under elevated temperatures and pressure. An understanding of the impacts of biomass composition on BFI yield and quality can inform genetic engineering strategies in the improvement of biochemical composition for biofuel production. In this work, wild type cyanobacterium Synechocystis sp. PCC 6803 biomass was doped with various common cellular storage compounds in lab-scale HTL experiments. Doping with glycogen or polyhydroxybutyrate (PHB) significantly reduced BFI yields, while doping with triglycerides (TAG) or medium chain-length polyhydroxyalkanoate (mcl-PHA) increased BFI yield and quality. In light of these observations, a genetically engineered Synechocystis strain deficient in glycogen biosynthesis was cultivated to produce biomass for HTL, leading to a 17% increase in BFI yield. In addition, we built a multiphase component additivity (MCA) model that can predict BFI yield and quality with PHAs in the biomass. This work demonstrates an effective strategy to integrate strain development with downstream biomass conversion to maximize biofuel yield, with lessons applicable to microalgae as well as other biomass.

09 BIOMASS FUELS↗

Study of structural, transport and magneto-crystalline anisotropy in La 1-x Sr x MnO 3 (0.30 ≤ x ≤ 0.40) perovskite manganites

In this paper we present structural, transport, magnetic and magneto-crystalline anisotropy of La 1–x Sr x MnO 3 (х = 0.30, 0.33, 0.36, and 0.40) synthesized using the solid-state reaction method. The X-ray diffraction pattern of the samples is well indexed to the rhombohedral structure with R 3 - c space group. Lattice parameters and unit cell volume are found to decrease monotonically upon increasing Sr 2+ concentration at La 3+ site. X-ray photoelectron spectroscopy confirms the presence of Mn 4+ and Mn 3+ , the ratio of which (Mn 4+ /Mn 3+ ) increases from 0.44 to 0.64 with increasing Sr 2+ concentration. From the ρ(T) and M(T) data analysis, we find that T MI and M S are larger for x = 0.33 composition, suggesting a weakening of the double-exchange interaction due to competing super-exchange interactions in x = 0.30, 0.36 and 0.40 samples. We calculated MCA constant (K 1 ) by fitting the saturation magnetisation data at a higher magnetic field using the law of approach model, M = M S [1-a/H-b/H 2 ]-χH with K 1 2 = (105/8)bMs 2 and is in the order of 10 5 erg/cm 3 .

36 MATERIALS SCIENCE↗

Understanding the Interplay between Hardware Errors and User Job Characteristics on the Titan Supercomputer

Designing dependable supercomputers begins with an understanding of errors in real-world, large-scale systems. The Titan supercomputer at Oak Ridge National Laboratory provides a unique opportunity to investigate errors when an actual system is actively used by multiple concurrent users and workloads from diverse domains at varying scales. This study presents a thorough analysis of 6, 908, 497 hardware errors from 18, 688 compute nodes of Titan for 312, 215 user jobs over a 3-year time period. Through careful joining of two system logs – the Machine Check Architecture (MCA) log and the job scheduler log – we show the correlated pattern of hardware errors for each job and user, in addition to individual descriptive statistics of errors, jobs, and users. Since the majority of hardware errors are memory errors, this study also shows the importance of error correcting in memory systems.

Lim, Seung-Hwan↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Down-selection of Innovative Fusion Materials

The goal of this proposal is to develop and fundamentally understand the microstructure of refractory multi-component alloys (MCA) as fusion-relevant plasma facing and structural materials, a step to down-select innovative fusion materials prior to the process of advancing their technology readiness level (TRL). Developing materials is paramount to enable fusion as energy source since no existing material is capable of coping with such extreme conditions. We will aim at understanding the role of chemistry and microstructure in these complex multi-component alloys systematically comparing their performance with pure tungsten materials in terms of mechanical properties and manufacturability. Such understanding will open opportunities to optimize MCAs for fusion applications and has a potential of attracting industry partnership.

36 MATERIALS SCIENCE↗