Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic domain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Conceptual design of a 10 to the 8th power bit magnetic bubble domain mass storage unit and fabrication, test and delivery of a feasibility model

The conceptual design of a highly reliable 10 to the 8th power-bit bubble domain memory for the space program is described. The memory has random access to blocks of closed-loop shift registers, and utilizes self-contained bubble domain chips with on-chip decoding. Trade-off studies show that the highest reliability and lowest power dissipation is obtained when the memory is organized on a bit-per-chip basis. The final design has 800 bits/register, 128 registers/chip, 16 chips/plane, and 112 planes, of which only seven are activated at a time. A word has 64 data bits +32 checkbits, used in a 16-adjacent code to provide correction of any combination of errors in one plane. 100 KHz maximum rotational frequency keeps power low (equal to or less than, 25 watts) and also allows asynchronous operation. Data rate is 6.4 megabits/sec, access time is 200 msec to an 800-word block and an additional 4 msec (average) to a word. The fabrication and operation are also described for a 64-bit bubble domain memory chip designed to test the concept of on-chip magnetic decoding. Access to one of the chip's four shift registers for the read, write, and clear functions is by means of bubble domain decoders utilizing the interaction between a conductor line and a bubble.

Source record↗

Magnetic bubble domain memories

Some attractive features of Bubble Domain Memory and its relation to existing technologies are discussed. Two promising applications are block access mass memory and tape recorder replacement. The required chip capabilities for these uses are listed, and the specifications for a block access mass memory designed to fit between core and HPT disk are presented. A feasibility model for a tape recorder replacement is introduced.

Ypma, J. E.↗

A magnetic bubble domain flight recorder

A feasibility model of an all-electronic bubble memory system has been constructed. It uses a small 60k bit bubble recorder consisting of 6 chips of 10k bits each mounted in three separate packages operating as a FIFO at a 150 KHz bubble data rate. In addition to serving as a direct tape recorder replacement, the bubble recorder can be programmed for random access to each individual chip for ranom block access operation or for self-checking or by-passing any malfunctioning memory chip. Read and write operations can be performed asynchronously from very low frequency up to basic recording field frequency. A large 50M bit prototype is planned.

Chen, T. T.↗

Packaging of a large capacity magnetic bubble domain spacecraft recorder

A Solid State Spacecraft Data Recorder (SSDR), based on bubble domain technology, having a storage capacity of 10 to the 8th power bits, was designed and is being tested. The recorder consists of two memory modules each having 32 cells, each cell containing sixteen 100 kilobit serial bubble memory chips. The memory modules are interconnected to a Drive and Control Unit (DCU) module containing four microprocessors, 500 integrated circuits, a RAM core memory and two PROM's. The two memory modules and DCU are housed in individual machined aluminum frames, are stacked in brick fashion and through bolted to a base plate assembly which also houses the power supply.

Becker, F. J.↗

Geophysical Methods: an Overview

Geophysics is expected to have a major role in lunar resource assessment when manned systems return to the Moon. Geophysical measurements made from a lunar rover will contribute to a number of key studies: estimating regolith thickness, detection of possible large-diameter lava tubes within maria basalts, detection of possible subsurface ice in polar regions, detection of conductive minerals that formed directly from a melt (orthomagmatic sulfides of Cu, Ni, Co), and mapping lunar geology beneath the regolith. The techniques that can be used are dictated both by objectives and by our abilities to adapt current technology to lunar conditions. Instrument size, weight, power requirements, and freedom from orientation errors are factors we have considered. Among the geophysical methods we believe to be appropriate for a lunar resource assessment are magnetics, including gradiometry, time-domain magnetic induction, ground-penetrating radar, seismic reflection, and gravimetry.

Becker, A.↗

Advanced quantitative magnetic nondestructive evaluation methods - Theory and experiment

The paper reviews the scale of fatigue crack phenomena in relation to the size detection capabilities of nondestructive evaluation methods. An assessment of several features of fatigue in relation to the inspection of ball and roller bearings suggested the use of magnetic methods; magnetic domain phenomena including the interaction of domains and inclusions, and the influence of stress and magnetic field on domains are discussed. Experimental results indicate that simplified calculations can be used to predict many features of these results; the data predicted by analytic models which use finite element computer analysis predictions do not agree with respect to certain features. Experimental analyses obtained on rod-type fatigue specimens which show experimental magnetic measurements in relation to the crack opening displacement and volume and crack depth should provide methods for improved crack characterization in relation to fracture mechanics and life prediction.

Barton, J. R.↗

Magnetic Force Microscopy Images of Magnetic Garnet With Thin-Film Magnetic Tip

We present magnetic force microscopy images of YGdTmGa/YSmTmGa magnetic garnet, usinga thin Fe film deposited on Si_3N_5 tips. We have found correlations between the topography andthe magnetic domain structure. We have observed the domain wall contrast with a iron thin-film tip. We report on domain wall imaging of garnet with magnetic force microscopy.

Wadas, A.↗

Integrated Vertical Bloch Line (VBL) memory

Vertical Bloch Line (VBL) Memory is a recently conceived, integrated, solid state, block access, VLSI memory which offers the potential of 1 Gbit/sq cm areal storage density, data rates of hundreds of megabits/sec, and submillisecond average access time simultaneously at relatively low mass, volume, and power values when compared to alternative technologies. VBLs are micromagnetic structures within magnetic domain walls which can be manipulated using magnetic fields from integrated conductors. The presence or absence of BVL pairs are used to store binary information. At present, efforts are being directed at developing a single chip memory using 25 Mbit/sq cm technology in magnetic garnet material which integrates, at a single operating point, the writing, storage, reading, and amplification functions needed in a memory. The current design architecture, functional elements, and supercomputer simulation results are described which are used to assist the design process.

Katti, R. R.↗

Laser Patterning Assisted Devitrification and Domain Engineering of Amorphous and Nanocrystalline Alloys

We have investigated laser-patterning and devitrification as a novel method to realize emergent properties in modified regions at the ribbon surface consisting of periodic localized laser spots thermally treated under rapid heating and cooling conditions. Fe-based amorphous ribbons were annealed for systematically varied laser power. Extremely high heating and cooling rates on the order of 10(exp 8)-10(exp 10)K/s have been estimated by finite element analysis simulations. Observations suggest surface melting followed by rapid solidification fast enough to quench and form an amorphous structure upon cooling. Diffusion of heat occurs from the laser irradiated surface region so that a finite volume of material surrounding this region rises in temperature above the crystallization temperature relevant for conventional isothermal annealing experiments. The underlying mechanism of laser annealing and consequences of heat transients involved are discussed in terms of impacts upon micro/nanostructure, residual stresses, and magnetic domain structure surrounding the laser irradiated region. The study illustrates the potential to exploit spatially optimized phase transformations in a scalable manufacturing process of amorphous and nanocrystalline alloys to locally access otherwise inaccessible extreme heating and cooling rates.

Amorphous ribbons↗

Characterization facility for magneto-optic media and systems

Objectives of this research are: (1) to measure the hysteresis loop, Kerr rotation angle, anisotropy energy profile, Hall voltage, and magnetoresistance of thin-film magneto-optic media using our loop-tracer; (2) measure the wavelength-dependence of the Kerr rotation angle, Theta(sub k), and ellipticity, epsilon(sub k), for thin-film media using our magneto-optic Kerr spectrometer (MOKS); (3) measure the dielectric tensor of thin-film and multilayer samples using our variable-angle magneto-optic ellipsometer (VAMOE); (4) measure the hysteresis loop, coercivity, remanent magnetization, saturation magnetization, and anisotropy energy constant for thin film magnetic media using vibrating sample magnetometry; (5) observe small magnetic domains and investigate their interaction with defects using magnetic force microscopy; (6) perform static read/write/erase experiments on thin-film magneto-optic media using our static test station; (7) integrate the existing models of magnetization, magneto-optic effects, coercivity, and anisotropy in an interactive and user-friendly environment, and analyze the characterization data obtained in the various experiments, using this modeling package; (8) measure focusing- and tracking-error signals on a static testbed, determine the 'feedthrough' for various focusing schemes, investigate the effects of polarization and birefringence, and compare the results with diffraction-based calculations; and (9) measure the birefringence of optical disk substrates using two variable angle ellipsometers.

Mansuripur, M.↗

Domain Collapse in Grooved Magnetic Garnet Material

Domain collapse fields in grooved garnet material were investigated by experimental observation and numerical simulation. The results indicate that the change in domain collapse field is largely due to magnetostatic effects produced by the groove edge. A simplified model based on the effective field produced at a groove edge, and local changes in the material thickness explain the observed trends very well.!.

Grooved Magnetic Garnet Material↗

Large Scale Magnetostrictive Valve Actuator

Marshall Space Flight Center's Valves, Actuators and Ducts Design and Development Branch developed a large scale magnetostrictive valve actuator. The potential advantages of this technology are faster, more efficient valve actuators that consume less power and provide precise position control and deliver higher flow rates than conventional solenoid valves. Magnetostrictive materials change dimensions when a magnetic field is applied; this property is referred to as magnetostriction. Magnetostriction is caused by the alignment of the magnetic domains in the material s crystalline structure and the applied magnetic field lines. Typically, the material changes shape by elongating in the axial direction and constricting in the radial direction, resulting in no net change in volume. All hardware and testing is complete. This paper will discuss: the potential applications of the technology; overview of the as built actuator design; discuss problems that were uncovered during the development testing; review test data and evaluate weaknesses of the design; and discuss areas for improvement for future work. This actuator holds promises of a low power, high load, proportionally controlled actuator for valves requiring 440 to 1500 newtons load.

Richard, James A.↗

Partially Grooved Domain Stabilization Structures for Vertical Bloch Line Memory

Bias field stability ranges were measured and numerically simulated for magnetic domains ingarnets stabilized by partially grooved rectangular and ring grooves. Simulation results agreefavorably with experimental results when finite slope effects of the groove walls are included. Asbias fields increase, rectangular and ring domains both destabilize through stripe head recession. Asbias fields decrease, destabilization in rectangular domains occurs by runout, while destabilization inring domains occurs by midstripe domain buckling. While ring domains are stable at lower biasfields than rectangular domains, bias field stability ranges are approximately equal. Hence, for thesame partial grooving depth, rectangular domains are preferred because they offer higher storagedensity potential in Vertical Block Line (VBL) storage arrays as long as bit propagation margins atstripe ends are sufficient.

Katti, R. R.↗

Elementary Theoretical Forms for the Spatial Power Spectrum of Earth's Crustal Magnetic Field

The magnetic field produced by magnetization in Earth's crust and lithosphere can be distinguished from the field produced by electric currents in Earth's core because the spatial magnetic power spectrum of the crustal field differs from that of the core field. Theoretical forms for the spectrum of the crustal field are derived by treating each magnetic domain in the crust as the point source of a dipole field. The geologic null-hypothesis that such moments are uncorrelated is used to obtain the magnetic spectrum expected from a randomly magnetized, or unstructured, spherical crust of negligible thickness. This simplest spectral form is modified to allow for uniform crustal thickness, ellipsoidality, and the polarization of domains by an periodically reversing, geocentric axial dipole field from Earth's core. Such spectra are intended to describe the background crustal field. Magnetic anomalies due to correlated magnetization within coherent geologic structures may well be superimposed upon this background; yet representing each such anomaly with a single point dipole may lead to similar spectral forms. Results from attempts to fit these forms to observational spectra, determined via spherical harmonic analysis of MAGSAT data, are summarized in terms of amplitude, source depth, and misfit. Each theoretical spectrum reduces to a source factor multiplied by the usual exponential function of spherical harmonic degree n due to geometric attenuation with attitude above the source layer. The source factors always vary with n and are approximately proportional to n(exp 3) for degrees 12 through 120. The theoretical spectra are therefore not directly proportional to an exponential function of spherical harmonic degree n. There is no radius at which these spectra are flat, level, or otherwise independent of n.

Voorhies, C.↗

Characterization of Asymmetry in Magnetoacoustic Emission Burst by Numerical Processes

It has been well known that the pattern of the magnetoacoustic emission (MAE) burst observed during the sweep over one half-cycle of the hysteresis loop becomes asymmetric depending on the strength of the magnetic domain wall-defect interaction and the state of residual stresses in a ferromagnet. The ascending asymmetry due to the former has been observed at a very low frequency (.7 Hz) of applied AC magnetic field at a given amplitude. The descending asymmetry due to uniaxial compressive stress has been typically observed at the AC applied magnetic field frequency of 20 Hz. The physical interpretation of both types of asymmetry has been well established. It is, however, necessary to perform investigations of the dependence of asymmetry on externally controlled parameters such as the amplitude and frequency of the AC applied magnetic fields. The purpose of the present study is therefore to devise a mathematical means that describes the degree of asymmetry of the MAE burst and apply this scheme to investigate the AC magnetic field amplitude dependence of the asymmetry.

Namkung, M.↗

High voltage electron microscopy and electron diffraction of pyroxenes in type B lunar samples from Apollo 11

Lunar pyroxene 10044 specimens cleaved and sectioned by diamond knife ultramicrotomy were examined by standard (75 to 100 kV) and high voltage (200 kV) electron microscopy and diffraction. Salient findings based on evaluation of 2000 plates show uniform 300 to 600 A-wide bands, probably corresponding to single crystal domains, with lattice spacings of 2. A High resolution bright and dark field images of iron-rich and magnesium-rich crystals were compared with corresponding electron diffraction patterns. Possible relations of observed structures to magnetic domains were considered.

Fernandez-Moran, H.↗

Constraints on Axions from Cosmic Distance Measurements

Axion couplings to photons could induce photon-axion conversion in the presence of magnetic fields in the Universe. This conversion could impact various cosmic distance measurements, such as luminosity distances to type Ia supernovae and angular distances to galaxy clusters, in different ways. In this paper we consider different combinations of the most up-to-date distance measurements to constrain the axion-photon coupling. Employing the conservative cell magnetic field model for the magnetic fields in the intergalactic medium (IGM) and ignoring the conversion in the intracluster medium (ICM), we find the upper bounds on axion-photon couplings to be around 5 × 10^(−12) (nG/B) √(Mpc/s) Ge/V for axion masses m(a) below 10^(−13) eV, where B is the strength of the IGM magnetic field, and s is the comoving size of the magnetic domains. When including the conversion in the ICM, the upper bound is lowered and could reach 5 × 10^(−13) Ge/V for m(a) < 5 × 10^(−12) eV. While this stronger bound depends on the ICM modeling, it is independent of the strength of the IGM magnetic field, for which there is no direct evidence yet. These constraints could be placed on firmer footing with an enhanced understanding and control of the astrophysical uncertainties associated with the IGM and ICM. All the bounds are determined by the shape of the Hubble rate as a function of redshift reconstructable from various distance measurements, and insensitive to today’s Hubble rate, of which there is a tension between early and late cosmological measurements. As an appendix, we discuss the model building challenges of the use of photon-axion conversion to make type Ia supernovae brighter to alleviate the Hubble problem/crisis.

Cosmology of Theories beyond the SM↗