Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic field readouts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hardware development for Gravity Probe-B

Gravity Probe-B (GP-B), also known as the Stanford Relativity Gyroscope Experiment, will test two fundamental predictions of Einstein's General Theory of Relativity by precise measurement of the precessions of nearly perfect gyroscopes in earth orbit. This endeavor embodies state-of-the-art technologies in many fields, including gyroscope fabrication and readout, cryogenics, superconductivity, magnetic shielding, precision optics and alignment methods, and satellite control systems. These technologies are necessary to enable measurement of the predicted precession rates to the milliarcsecond/year level, and to reduce to 'near zero' all non-General Relativistic torques on the gyroscopes. This paper provides a brief overview of the experiment followed by descriptions of several specific hardware items with highlights on progress to date and plans for future development and tests.

Bardas, D.↗

Ultra-low magnetic field apparatus for a cryogenic gyroscope

An ultralow magnetic field apparatus for earth-based testing of a cryogenic gyroscope system designed for a satellite test of general relativity is described. The magnetic field apparatus makes use of a superconducting lead shield while also maintaining sufficient mechanical stability to obtain a gyroscope readout sensitivity of one arcsec over a limited range. A gyroscope environment of 2.3 times 10 to the minus seventh power gauss has been attained with the magnetic field shielding technique. The magnetic field apparatus is to be used with a three-axis London moment readout system.

Cabrera, B.↗

Quantum Enhanced Probes of Magnetic Circular Dichroism

Magneto-optical microscopies, including optical measurements of magnetic circular dichroism, are increasingly ubiquitous tools for probing spin-orbit coupling, charge-carrier g-factors, and chiral excitations in matter, but the minimum detectable signal in classical magnetic circular dichroism measurements is fundamentally limited by the shot-noise limit of the optical readout field. Here, a two-mode squeezed light source is used to improve the minimum detectable signal in magnetic circular dichroism measurements by 3 decibels compared with state-of-the-art classical measurements, even with relatively lossy samples like terbium gallium garnet. Furthermore, these results provide a framework for new quantum-enhanced magneto-optical microscopies that are particularly critical for environmentally sensitive materials and for low temperature measurements where increased optical power can introduce unacceptable thermal perturbations.

42 ENGINEERING↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconfigurable training and reservoir computing in an artificial spin-vortex ice via spin-wave fingerprinting

Strongly interacting artificial spin systems are moving beyond mimicking naturally occurring materials to emerge as versatile functional platforms, from reconfigurable magnonics to neuromorphic computing. Typically, artificial spin systems comprise nanomagnets with a single magnetization texture: collinear macrospins or chiral vortices. Here, by tuning nanoarray dimensions we have achieved macrospin–vortex bistability and demonstrated a four-state metamaterial spin system, the ‘artificial spin-vortex ice’ (ASVI). ASVI can host Ising-like macrospins with strong ice-like vertex interactions and weakly coupled vortices with low stray dipolar field. Vortices and macrospins exhibit starkly differing spin-wave spectra with analogue mode amplitude control and mode frequency shifts of Δf = 3.8 GHz. The enhanced bitextural microstate space gives rise to emergent physical memory phenomena, with ratchet-like vortex injection and history-dependent non-linear fading memory when driven through global magnetic field cycles. We employed spin-wave microstate fingerprinting for rapid, scalable readout of vortex and macrospin populations, and leveraged this for spin-wave reservoir computation. ASVI performs non-linear mapping transformations of diverse input and target signals in addition to chaotic time-series forecasting.

97 MATHEMATICS AND COMPUTING↗

Quality and Loss Factor Analysis of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons in a magnetic field, which produces extremely small signals requiring low-loss cryogenic transmission lines for readout to reduce noise and attenuation. Yttrium Barium Copper Oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss superconducting cables such as Niobium (Nb) and Niobium Titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We evaluate their suitability by characterizing the quality and loss factors of five stripline resonators (three YBCO, and copper and silver references) from the Brookhaven Technology Group at 77 K without an external field, and cooled to 30 mK in a 14 T magnet. For measurements at 77 K we recorded scattering parameter data and employed Lorentzian and circle-fitting analysis techniques. We identified the best-performing resonator and developed a cryogenic probe for future testing in the magnet at millikelvin temperatures.

Marinos, Zoe [UCLA]↗

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the Microcalorimeter Detector for Athena/X-IFU

The X-ray Integral Field Unit (X-IFU) will be a microcalorimeter instrument on ESA’s Athena X-ray observatory, set to launch around 2037. Athena recently underwent a reformulation exercise resulting in a simplified X-IFU architecture, with a new baseline configuration featuring fewer pixels and readout channels. Newly developed transition edge sensor pixels that are slower and have reduced magnetic field sensitivity have helped enable the new instrument design whilst maintaining flagship quality science. In this paper, we report on the status and plan for continued development of the X-IFU microcalorimeter array. We describe details of the current pixel architecture and performance specifications. We will present the design of the first full scale microcalorimeter arrays that have the necessary flight like electrical and mechanical interfaces for X-IFU. These arrays will undergo testing in a focal-plane assembly (FPA) Development Model (DM) in Europe later in 2024 and serve as a precursor to the X-IFU Engineering Model detector.

Stephen J Smith↗

Magnetic tape lightning current detectors

Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

Crouch, K. E.↗

A feasible path for the use of ferromagnetic josephson junctions in quantum circuits: The ferro-transmon

We discuss the capabilities of ferromagnetic (F) Josephson junctions (JJs) in a variety of layouts and configurations. The main goal is to demonstrate the potential of these hybrid JJs to disclose new physics and the possibility to integrate them in superconducting classical and quantum electronics for various applications. The feasible path towards the use of ferromagnetic Josephson junctions in quantum circuits starts from experiments demonstrating macroscopic quantum tunneling in NbN/GdN/NbN junctions with ferro-insulator barriers and with triplet components of the supercurrent, supported by a self-consistent electrodynamic characterization as a function of the barrier thickness. This has inspired further studies on tunnel ferromagnetic junctions with a different layout and promoted the first generation of ferromagnetic Al-based JJs, specifically Al/AlO x /Al/Py/Al. This layout takes advantage of the capability to integrate the ferromagnetic layer in the junction without affecting the quality of the superconducting electrodes and of the tunnel barrier. The high quality of the devices paves the way for the possible implementation of Al tunnel-ferromagnetic JJs in superconducting quantum circuits. These achievements have promoted the notion of a novel type of qubit incorporating ferromagnetic JJs. This qubit is based on a transmon design featuring a tunnel JJ in parallel with a ferromagnetic JJ inside a SQUID loop capacitively coupled to a superconducting readout resonator. In conclusion, the effect of an external RF field on the magnetic switching processes of ferromagnetic JJs has been also investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrically Controlled All-Antiferromagnetic Tunnel Junctions on Silicon with Large Room-Temperature Magnetoresistance

Antiferromagnetic (AFM) materials are a pathway to spintronic memory and computing devices with unprecedented speed, energy efficiency, and bit density. Realizing this potential requires AFM devices with simultaneous electrical writing and reading of information, which are also compatible with established silicon-based manufacturing. Recent experiments have shown tunneling magnetoresistance (TMR) readout in epitaxial AFM tunnel junctions. However, these TMR structures are not grown using a silicon-compatible deposition process, and controlling their AFM order required external magnetic fields. Here are shown three-terminal AFM tunnel junctions based on the noncollinear antiferromagnet PtMn 3 , sputter-deposited on silicon. The devices simultaneously exhibit electrical switching using electric currents, and electrical readout by a large room-temperature TMR effect. First-principles calculations explain the TMR in terms of the momentum-resolved spin-dependent tunneling conduction in tunnel junctions with noncollinear AFM electrodes.

36 MATERIALS SCIENCE↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Superconducting Levitated Detector of Gravitational Waves

A magnetically levitated mass couples to gravity and can act as an effective gravitational wave detector. We show that a superconducting sphere levitated in a quadrupolar magnetic field, when excited by a gravitational wave, will produce magnetic field fluctuations that can be read out using a flux tunable microwave resonator. With a readout operating at the standard quantum limit, such a system could achieve broadband strain noise sensitivity of h ≲ 10 − 20 / Hz for frequencies of 1 kHz–1 MHz, opening new corridors for astrophysical probes of new physics. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trigonal Bipyramidal V 3+ Complex as an Optically Addressable Molecular Qubit Candidate

Synthetic chemistry enables a bottom-up approach to quantum information science, where atoms can be deterministically positioned in a quantum bit or qubit. Two key requirements to realize quantum technologies are qubit initialization and read-out. By imbuing molecular spins with optical initialization and readout mechanisms, analogous to solid-state defects, molecules could be integrated into existing quantum infrastructure. To mimic the electronic structure of optically addressable defect sites, we designed the spin-triplet, V 3+ complex, (C 6 F 5 ) 3 trenVCN t Bu (1).We measured the static spin properties as well as the spin coherence time of1demonstrating coherent control of this spin qubit with a 240 GHz electron paramagnetic resonance spectrometer powered by a free electron laser. We found that1exhibited narrow, near-infrared photoluminescence (PL) from a spin-singlet excited state. Using variable magnetic field PL spectroscopy, we resolved emission into each of the ground-state spin sublevels, a crucial component for spin-selective optical initialization and readout. This work demonstrates that trigonally symmetric, heteroleptic V 3+ complexes are candidates for optical spin addressability.

30 DIRECT ENERGY CONVERSION↗

Variable Permeability Magnetometer Systems and Methods for Aerospace Applications

A magnetometer configured to measure low field strength magnetic fields is provided. Certain embodiments of the magnetometer include a cylindrical coil assembly having a variable permeability core and terminals disposed at both ends. A current source circuit may be operably connected to the terminals and configured to apply a voltage controlled current across the terminals. A voltage readout circuit may be operably connected to the terminals and configured to measure a voltage across the terminals due to the applied current from the current source. An inductance of the coil assembly directly varies as an ambient magnetic field strength varies a permeability of the variable permeability core, and a voltage across the terminals varies directly with the inductance such that the measured voltage across the terminals is a direct measure of the ambient magnetic field strength.

Shams, Qamar A.↗

The CLAS12 Micromegas Vertex Tracker

The Micromegas Vertex Tracker was designed to improve upon the tracking capabilities of the baseline design of the CLAS12 spectrometer in Hall~B at Jefferson Laboratory. A Barrel Micromegas Tracker made with six concentric cylinders, each made of three 120$^\circ$-sector tiles, surrounds the Silicon Vertex Tracker, and a Forward Micromegas Tracker composed of 6 disks is placed 30~cm downstream of the liquid-hydrogen target. Both trackers sit in a 5~T solenoid magnetic field. All Micromegas elements are based on resistive technology to withstand luminosities up to $10^{35}$~cm$^{-2}$s$^{-1}$, as well as on bulk technology to enforce gain uniformity and mechanical robustness. Due to the high magnetic field, dedicated electronics have been designed and displaced $\sim$2~m away from the detectors. The electronics readout is based on the DREAM ASICs that allow sustained operation up to 20~kHz trigger rate at the maximum luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗