Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

A practical approach to calculating magnetic Johnson noise for precision measurements

Magnetic Johnson noise is an important consideration for many applications involving precision magnetometry, and its significance will only increase in the future with improvements in measurement sensitivity. The fluctuation–dissipation theorem can be utilized to derive analytic expressions for magnetic Johnson noise in certain situations, but when used in conjunction with finite element analysis tools, the combined approach is particularly powerful as it provides a practical means to calculate the magnetic Johnson noise arising from conductors of arbitrary geometry and permeability. In this paper, we demonstrate this method to be one of the most comprehensive approaches presently available to calculate thermal magnetic noise. In particular, its applicability is shown to not be limited to cases where the noise is evaluated at a point in space but also can be expanded to include cases where the magnetic field detector has a more general shape, such as a finite-size loop, a gradiometer, or a detector that consists of a polarized atomic species trapped in a volume. Furthermore, some physics insights gained through studies made using this method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Parallel Diffusion Coefficient of Energetic Charged Particles in the Inner Heliosphere from the Turbulent Magnetic Fields Measured by Parker Solar Probe

Diffusion coefficients of energetic charged particles in turbulent magnetic fields are a fundamental aspect of diffusive transport theory but remain incompletely understood. In this work, we use quasi-linear theory to evaluate the spatial variation of the parallel diffusion coefficient κ ∥ from the measured magnetic turbulence power spectra in the inner heliosphere. We consider the magnetic field and plasma velocity measurements from Parker Solar Probe made during Orbits 5–13. The parallel diffusion coefficient is calculated as a function of radial distance from 0.062 to 0.8 au, and the particle energy from 100 keV to 1 GeV. We find that κ ∥ increases exponentially with both heliocentric distance and energy of particles. The fluctuations in κ ∥ are related to the episodes of large-scale magnetic structures in the solar wind. By fitting the results, we also provide an empirical formula of κ ∥ = (5.16 ± 1.22) × 10 18 r 1.17 ± 0.08 E 0.71 ± 0.02 (cm 2 s -1 ) in the inner heliosphere, which can be used as a reference in studying the transport and acceleration of solar energetic particles as well as the modulation of cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the Room Temperature Field Quality Measurements of HL-LHC MQXFA Magnet Assemblies

As a member of the multi-lab U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), Lawrence Berkeley National Laboratory (LBNL) is assembling high-field Nb3Sn low-beta MQXFA quadrupole magnets for eventual installation at CERN as part of the HL-LHC upgrade. Each magnet undergoes room temperature magnetic measurements at two points during the assembly process: once after completion of the coil pack sub-assembly and once after the magnet is fully assembled and pre-loaded. Beyond its use to verify that each magnet assembly can meet operational requirements, the data from this two-stage measurement process allow for investigation into the impact of the pre-loading operation on field quality. Recent measurements on magnet rebuilds as well as exploratory coil pack reconfigurations also provide an opportunity to see in isolation the effects of changes to a magnet’s coil selection or coil layout. In this work, we present the magnetic measurement results of MQXFA magnets assembled or currently in process, focusing particularly on magnets with data corresponding to multiple builds, and discuss trends and insights which may be beneficial for the remaining MQXFA magnet production or for future Nb3Sn accelerator magnets.

Doyle, Jennifer [LBNL, Berkeley] (ORCID:0009000079↗

Magnetic Materials Research at SRNL

Fig: Rietveld Refinement of room temperature PXRD data for annealed Ce2Fe14B (left panel), (Y0.1Ce1.9)Fe14B (middle panel), and (Lu0.1Ce1.90)Fe14B (right panel) alloys. All annealed alloys plotted are composed primarily of Ce2Fe14B phase with small α-Fe impurities. Vertical blue ticks correspond to the position of the calculated Bragg peaks of all phases (from top to bottom, 2-14-1 and α-Fe). Fig: (Left Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the easy direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Middle Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the hard direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Right Panel) The saturation magnetization of Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys as determined from easy axis field dependent magnetization measurements.

Bretana, Alex↗

Non-intrusive measurement of magnetic field strengths in a low-pressure argon plasma using quantum beat spectroscopy

Abstract Accurate measurement of magnetic field strengths is critical in many plasma environments, ranging from astrophysical systems to fusion energy research. In this work, a non-perturbative laser-based optical diagnostic known as quantum beat spectroscopy is demonstrated to be good alternative for measuring the magnetic field strength in low-pressure laboratory plasmas. The technique is investigated using both ns and fs pulsed lasers in an argon plasma. Preliminary results for a helium plasma are also given. Zeeman-split J = 1 electron states with transitions from metastable states were identified and tested for neutral argon ( 2 P 1 / 2 o ) 4 p 2 [ 1 / 2 ] and neutral helium 1 s 3 p 1 P 1 o . Magnetic fields are measured with sub-Gauss precision at near single laser pulse acquisition rates.

Gilbert, Tyler J. (ORCID:0000000160400119)↗

Magnetic anisotropy in uranium monosulfide probed by magnetic torque measurements

We have studied the magnetic torque in uranium monosulfide (US) single crystals to explore the magnetic anisotropy in this material. Uranium monosulfide crystallizes in a cubic, NaCl-type of crystal structure and exhibits the largest magnetocrystalline anisotropy observed in cubic systems. By performing detailed torque measurements we observe a strongly anisotropic behavior in the paramagnetic phase due to crystal defects and quadrupolar pair interactions. Our studies also confirm the presence of a large anisotropy in the ferromagnetic state of the US system with the <100>, <111>, and <110> directions being the hard, easy, and intermediate axes, respectively. Furthermore, the anisotropy in the paramagnetic phase shows similar characteristics to the anisotropy observed in the ferromagnetic phase, as characterized by second and fourth rank susceptibility terms. The similarity of the anisotropic behaviors in paramagnetic and ferromagnetic phases is the consequence of strong magnetoelastic properties in this system, which possibly lead to the rhombohedral structural distortion, not only in the ferromagnetic phase but also in the paramagnetic phase (induced by applied magnetic field).

36 MATERIALS SCIENCE↗

Crystal structure and magnetic properties of Gd 8 Mn 3 Sb 19

Here, in this study, a novel magnetic semimetal compound, Gd 8 Mn 3 Sb 19 , was synthesized successfully via high-temperature solid-state reaction. The crystal structure of Gd 8 Mn 3 Sb 19 was determined using both single crystal and powder X-ray diffraction techniques, revealing a non-centrosymmetric orthorhombic space group, Pmn2 1 (No. 31). The Sb atoms in Gd 8 Mn 3 Sb 19 form five-atom-wide Sb 5 7− ribbons, narrower three-atom-wide Sb 3 5− ribbons, and single Sb 3− anions. On the other hand, both Gd 3+ and Mn 2+ ions form the distorted Gd 3 and Mn 3 triangular lattices, respectively. The magnetic measurements suggest the complex magnetic interactions contributed by both Gd 3+ and Mn 2+ ions. A sharp peak observed in the magnetic susceptibility plot at approximately 25 K corresponds to the antiferromagnetic-type transition in Gd 8 Mn 3 Sb 19 . Furthermore, the magnetic measurements along different directions indicate the strong magnetic anisotropy present in Gd 8 Mn 3 Sb 19 , which is likely due to the complex magnetic interactions arising from the existence of Gd and Mn ions. Finally, the electrical resistivity measurements of Gd 8 Mn 3 Sb 19 indicate semimetallic behavior with a positive magnetoresistance.

Chemistry↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Higher Dimensionality in the Mg–Co–B System: Synthesis and Structure of Incommensurate Composite Mg 1+ε Co 4 B 4

Guided by high-temperature in situ X-ray diffraction, the discovery and synthesis of Mg 1+ε Co 4 B 4 (ε ≈ 0.272) using a MgH 2 hydride precursor is reported, along with a detailed crystal structure description and measurement of magnetic properties. The mismatch in lattice periodicities between Mg and Co–B substructures places Mg 1+ε Co 4 B 4 in the family of incommensurate composite crystals and prompted structural refinement in a (3 + 1)-dimensional model. The structure of Mg 1+ε Co 4 B 4 (P4 2 /ncm(00γ)s00s, a = 6.75847(7) Å, c = 3.94007(8) Å, q = (0, 0, 1.2721(3))) was refined from neutron powder diffraction and high-resolution powder X-ray diffraction data and confirmed by scanning transmission electron microscopy and electron diffraction. Mg 1+ε Co 4 B 4 is isostructural to Nd 1+ε Fe 4 B 4 and several related ternary borides with 0.07 ≤ ε ≤ 0.17, with Mg occupying the rare-earth site. Satellite reflections in the electron diffraction patterns hinted at positional modulation of the transition metal–boron substructure by Mg atoms, but this could not be refined from the neutron or X-ray diffraction data. Low-temperature magnetic measurements show no indications of long-range magnetic ordering or superconductivity down to 5 K. DFT calculations confirmed the absence of a magnetically ordered ground state and the stability of a 5:4 supercell (ε = 0.25) relative to the fully commensurate structure. Neutron diffraction and synthesis from elemental Mg demonstrated that Mg 1+ε Co 4 B 4 is not a hydrogen-stabilized phase. Mg 1+ε Co 4 B 4 represents the second compound reported in the Mg–Co–B system and the first superspace symmetry model of a Nd 1+ε Fe 4 B 4 -type incommensurate composite compound refined from powder diffraction data.

chemical structure↗

Anomalous temperature-dependent magnetization in the nearly collinear antiferromagnet Y 2 Co 3

Y 2 Co 3 is a newly discovered antiferromagnetic (AFM) compound with distorted kagome layers. Here, previous investigations via bulk magnetization measurements suggested a complex non-collinear magnetic behavior, with magnetic moments primarily anti-aligned along the b axis and some canting towards the ac plane. In this study, we report the magnetic structure of Y 2 Co 3 to be an A-type AFM structure with ferromagnetic (FM) interactions within the distorted kagome plane and an inter-plane antiferromagnetic interaction, as determined by single crystal neutron diffraction. The magnetic moments align along the b axis, with minimal canting towards the c axis, at odds with the previous interpretation of bulk magnetization measurements. The magnetic moments on the two distinct Co sites are (0, -0.68, 0) μB and (0, 1.25, 0.07) μ B . We attribute the previously reported ”non-collinear” behavior to the considerable temperature dependence of itinerant AFM exchange interactions, induced by thermal contraction along the b axis. Additionally, our examination of lattice constants through pressure studies reveals compensating effects on FM and AFM interactions, resulting in negligible pressure dependence of T N .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗