Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Layer-resolved magnetic proximity effect in van der Waals heterostructures

Magnetic proximity effects are integral to manipulating spintronic, superconducting, excitonic and topological phenomena in heterostructures. These effects are highly sensitive to the interfacial electronic properties, such as electron wavefunction overlap and band alignment. The recent emergence of magnetic two-dimensional materials opens new possibilities for exploring proximity effects in van der Waals heterostructures. In particular, atomically thin CrI 3 exhibits layered antiferromagnetism, in which adjacent ferromagnetic monolayers are antiferromagnetically coupled. In this paper, we report a layer-resolved magnetic proximity effect in heterostructures formed by monolayer WSe 2 and bi/trilayer CrI 3 . By controlling the individual layer magnetization in CrI 3 with a magnetic field, we show that the spin-dependent charge transfer between WSe 2 and CrI 3 is dominated by the interfacial CrI 3 layer, while the proximity exchange field is highly sensitive to the layered magnetic structure as a whole. In combination with reflective magnetic circular dichroism measurements, these properties allow the use of monolayer WSe 2 as a spatially sensitive magnetic sensor to map out layered antiferromagnetic domain structures at zero magnetic field as well as antiferromagnetic/ferromagnetic domains at finite magnetic fields. Our work reveals a way to control proximity effects and probe interfacial magnetic order via van der Waals engineering.

36 MATERIALS SCIENCE↗

Electromagnetic Radiation Effects on MgO-Based Magnetic Tunnel Junctions: A Review

Magnetic tunnel junctions (MTJs) have been widely utilized in sensitive sensors, magnetic memory, and logic gates due to their tunneling magnetoresistance. Moreover, these MTJ devices have promising potential for renewable energy generation and storage. Compared with Si-based devices, MTJs are more tolerant to electromagnetic radiation. In this review, we summarize the functionalities of MgO-based MTJ devices under different electromagnetic irradiation environments, with a focus on gamma-ray radiation. We explore the effects of these radiation exposures on the MgO tunnel barriers, magnetic layers, and interfaces to understand the origin of their tolerance. This review enhances our knowledge of the radiation tolerance of MgO-based MTJs, improves the design of these MgO-based MTJ devices with better tolerances, and provides information to minimize the risks of irradiation under various irradiation environments. This review starts with an introduction to MTJs and irradiation backgrounds, followed by the fundamental properties of MTJ materials, such as the MgO barrier and magnetic layers. Then, we review and discuss the MTJ materials and devices’ radiation tolerances under different irradiation environments, including high-energy cosmic radiation, gamma-ray radiation, and lower-energy electromagnetic radiation (X-ray, UV–vis, infrared, microwave, and radiofrequency electromagnetic radiation). In conclusion, we summarize the radiation effects based on the published literature, which might benefit material design and protection.

42 ENGINEERING↗

Autonomous alignment and healing in multilayer soft electronics using immiscible dynamic polymers

Self-healing soft electronic and robotic devices can, like human skin, recover autonomously from damage. While current devices use a single type of dynamic polymer for all functional layers to ensure strong interlayer adhesion, this approach requires manual layer alignment. In this study, we used two dynamic polymers, which have immiscible backbones but identical dynamic bonds, to maintain interlayer adhesion while enabling autonomous realignment during healing. These dynamic polymers exhibit a weakly interpenetrating and adhesive interface, whose width is tunable. When multilayered polymer films are misaligned after damage, these structures autonomously realign during healing to minimize interfacial free energy. Finally, we fabricated devices with conductive, dielectric, and magnetic particles that functionally heal after damage, enabling thin-film pressure sensors, magnetically assembled soft robots, and underwater circuit assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning the Magnetic Properties of CrI 3 Using Ni Thin Film Deposition for Applications in Spintronic Devices

Chromium triiodide (CrI 3 ), a van der Waals magnet, has recently been shown to host Ising ferromagnetism down to the monolayer limit. It is a potentially important material in 2D magnet-based applications, such as magnetic sensors and spintronic devices. Prior studies have revealed the coexistence of two different types of interlayer magnetic coupling, the antiferromagnetic (AFM) coupling near the surface and ferromagnetic (FM) coupling in the deep bulk layers, in pristine CrI 3 crystals below the Curie temperature. In this study, we used Ni thin film deposition to tune the surface magnetic states in bulk CrI 3 . A nanometer thickness (4 nm thick) of Ni was deposited on the surface of CrI 3 using electron-beam evaporation to form a Ni/CrI 3 heterostructure. The deposited Ni thin layer forms nanoclusters that completely cover the CrI 3 surface. Magnetic states of CrI 3 before and after Ni deposition are probed by ultralow-frequency magneto-Raman spectroscopy. Instead of seeing three spin wave branches in Raman scattering below 2 T, as in pristine bulk CrI 3 , in Ni/CrI 3 , we observe only a single spin wave branch, which is softened compared to that in pristine CrI 3 and displays a Zeeman shift under an out-of-plane magnetic field up to 7 T. This observation reveals that the AFM layers on pristine CrI 3 crystal surfaces transit into FM layers, so the entire CrI 3 crystal is in the FM state after Ni deposition. First-principles calculations show that Ni atoms tend to diffuse into the CrI 3 lattice, and the FM interlayer coupling has a much lower energy than AFM coupling in the presence of Ni atoms. As a result, our studies show that the magnetic state of CrI 3 can be modified through deposition of a thin metal layer on the surface, offering a route for controlling the spin degree of freedom in van der Waals magnets.

36 MATERIALS SCIENCE↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced particle flux due to localized divertor MHD instability in DIII-D tokamak

An MHD mode with a frequency of <10 kHz has been identified near the inner strike point from various diagnostics, i.e., divertor Langmuir probes, magnetics sensors, and interferometers, but does not appear in the upstream and core diagnostics. This MHD mode is associated with magnetic oscillations of ≳5 G, has a long wavelength in the toroidal direction with toroidal mode number n=1, but is localized in a narrow radial region of a few cm. The mode appears when the outer strike point remains attached and the inner strike point nearly detaches, grows with increasing density, and eventually weakens and vanishes as the outer strike point detaches. This mode results in particle flux with an order of magnitude higher than the background plasmas near the inner strike point. The mode characteristics are consistent with the Current-Convective-Instability theory prediction. Initial simulations based on experimental input have found oscillations with similar frequencies but weaker amplitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Sensing via Acoustic Sensing Fiber with Metglas® 2605SC Cladding Wires

Magnetic field sensing has the potential to become necessary as a critical tool for long-term subsurface geophysical monitoring. The success of distributed fiber optic sensing for geophysical characterization provides a template for the development of next generation downhole magnetic sensors. In this study, Sentek Instrument’s picoDAS is coupled with a multi-material single mode optical fiber with Metglas® 2605SC cladding wire inclusions for magnetic field detection. The response of acoustic sensing fibers with one and two Metglas® 2605SC cladding wires was evaluated upon exposure to lateral AC magnetic fields. An improved response was demonstrated for a sensing fiber with in-cladding wire following thermal magnetic annealing (~400 °C) under a constant static transverse magnetic field (~200 μT). A minimal detectable magnetic field of ~500 nT was confirmed for a sensing fiber with two 10 μm cladding wires. The successful demonstration of a magnetic field sensing fiber with Metglas® cladding wires fabricated via traditional draw processes sets the stage for distributed measurements and joint inversion as a compliment to distributed fiber optic acoustic sensors.

Dejneka, Zach (ORCID:0000000179415708)↗

Multi-qubit nanoscale sensing with entanglement as a resource

Nitrogen vacancy (NV) centres in diamond are widely deployed as local magnetic sensors, using single-qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators or using entangled states to enhance measurement sensitivity. Here, in this work, we describe protocols for using optically unresolved NV centre pairs and nuclear spins as multi-qubit sensors for measuring correlated noise at nanometre length scales. For noninteracting NV centres, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations, leveraging the presence of a third qubit, a 13 C nucleus, to effect coherent single-NV spin flips and enable phase cycling even for co-aligned NV centres that are spectrally unresolved. For length scales around 10 nm, we create maximally entangled Bell states through dipole–dipole coupling between two NV centres and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centres. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV centre spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in more than an order of magnitude improvement in sensitivity. Finally, we demonstrate methods for detecting high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centres.

condensed-matter physics↗

Lab-on-a-Fish Monitoring Software V1.0

This is the original monitoring software for processing and displaying data for Lab-on-a-Fish. Lab-on-a-Fish simultaneously evaluates and monitors the health, behavior, and environment of fish or small aquatic species. The sensor is a miniaturized underwater monitoring system that measures animal behavior (acceleration and gyration); physiology (electrocardiogram and electromyogram); and environmental parameters (temperature, pressure, and magnetic sensor).

Deng, Daniel↗

Ultra-fast and sensitive magneto-optical hydrogen sensors using a magnetic nano-cap array

Magnetism in curved nano-geometries has opened a new path to design novel characteristics and phenomena that could greatly impact the future fundamental and applied studies of materials. Here, in this report, a hexagonally-packed array of magnetic nano-caps (or nano-patches, NP) exhibiting unique magnetic anisotropy and optimal nanostructure for fast hydrogen kinetics is explored as a sensing element for the spark-free magnetic-circular-dichroism (MCD) H 2 sensor. The MCD H 2 sensor outperforms the state-of-the-art optical sensors reported to date and satisfies the most challenging performance targets imposed by US Department of Energy. In particular, a Pd 67 Co 33 NP sensor exhibits response time of t 90 < 0.9 s, recovery time of t 10 < 9.0 s over the 1-100 mbar H 2 partial pressure range, and limit of detection (LOD) of ~1 ppm. The LOD improves to <700 ppb, when the signal-to-noise ratio is enhanced by stacking three NP arrays. Using a 30-nm TAF (Teflon AF 2400) polymer coating, the sorption kinetics of the Pd 67 Co 33 /TAF sensor are significantly accelerated, with t 90 < 0.4 s and t 10 < 2.8 s over the same pressure range. When the Pd 67 Co 33 /TAF sensor is further coated with a 100-nm poly(methyl methacrylate) (PMMA) layer, a rapid sorption time of t 90 < 0.5 s, LOD < 1 ppm and excellent sensor accuracy (<2.5% full scale) are maintained, while the sensor obtains strong selectivity against interference gases and moisture and a negligible aging effect. The MCD nano-cap sensor platform may have a great impact on the future deployment of H 2 fuel, H 2 environmental monitoring sensors, and fast proton-based magneto-ionic devices.

Fast and sensitive hydrogen sensors↗

Optimizing the differential connection schemes for detecting 3D magnetic perturbations in DIII-D

Optimizing the differential pair connection scheme (i.e. the set of pairs) of a toroidal array of magnetic sensors dedicated to measuring slowly rotating asymmetric fields can enhance the mode number detection capability and failure-resilience. In this work the condition number obtained from singular value decomposition (SVD) of the design matrix is used as a metric to evaluate the quality of a connection scheme. A large number of possible pair connections are usually available, so evaluating all of them may require extensive use of computational resources and can be very time consuming. Alternative methods to reduce the number of pairs evaluated without losing the capabilities of toroidal mode detection are presented in this paper. Here, three examples of the applications of such analysis for the 3D magnetic diagnostic system of DIII-D are also presented: the addition of two new toroidal arrays with n > 3 detection capabilities, the modification of an existing toroidal array in the low field side of the machine to accommodate the addition of a helicon antenna, and the design of changes in several toroidal arrays in the high field side to accommodate the addition of a lower hybrid current drive antenna on the center post.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of room temperature multiferroic and magneto-electric properties of (1-Φ) PZTFT-Φ CZFMO particulate composites

Multiferroic composites consisting of a single-phase multiferroic [0.6(PbZr 0.53 Ti 0.47 O 3 )-0.4(PbFe 0.5 Ta 0.5 )O 3 ] as a matrix and a magnetostrictive phase (Co 0.6 Zn 0.4 Fe 1.7 Mn 0.3 O 4 ) dispersed in the matrix are fabricated via hybrid synthesis technique. The structure and surface morphology studies using x-ray diffraction and field emission scanning electron microscopy techniques indicate the formation of 3-0 type particulate composites. Coexistence of soft-magnetic behavior and ferroelectric characteristics are confirmed for composites from magnetization vs magnetic field (M–H) and polarization vs electric field (P–E) measurements, respectively. Magneto-dielectric (MD) measurement shows significant changes in the dielectric properties with the application of a magnetic field, indicating the existence of strong MD behavior. The biquadratic nature of magneto-electric (ME) coupling is described by the Landau free energy equation arising from the strain transfer at the interfaces between the constituent phases. The direct magneto-electric voltage coefficient measurement also confirms very strong coupling between ferroelectricity and magnetism and supports the strain-mediated magneto-electric effect in composites. The Φ = 0.3 composite exhibits the maximum ME coefficient of 20.72 mV/cm Oe with M S = 24.62 emu/g, H C = 59.66 Oe, and piezoelectric coefficient value d 33 = 19 pC/N. In conclusion, the strong magneto-electric effect along with low dielectric loss at room temperature in these composites suggests their suitability for multifunctional magneto-electric device applications such as magnetic sensors, etc.

36 MATERIALS SCIENCE↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

An optical-input Maximum Likelihood Estimation feedback system demonstrated on tokamak horizontal equilibrium control

A readily parallelized Maximum Likelihood Estimation (MLE) algorithm with linear computational complexity is demonstrated in real time using only measurements from an extreme ultraviolet (EUV) diagnostic to control the horizontal position of a tokamak plasma. A set of trial emissivity profiles are parameterized by the control quantity of interest (R m ), and the MLE is identified from the profile which minimizes the signal reconstruction residual. The algorithm depends on an empirically determined likelihood function with exponential form. EUV emission (λ ≈ 15eV-1keV) is captured in a poloidal plane by four 16-channel AXUV diodes mounted at different poloidal angles with radial and angular resolution sufficient to discern plasma equilibrium evolution in HBT-EP. Calculations of the plasma major radius by the system are consistent within diagnostic uncertainty for the majority of the discharge with those of: a weighted average of vertical soft X-ray or EUV chords, magnetic sensors, and an equilibrium reconstruction. The feedback system corrects for a horizontal displacement of the major radius equal to 20% of the plasma minor radius by adjusting the vertical field produced from 40 in-vessel control coils in real time. The MLE calculation is performed on a GPU in a 15 μs cycle, with similar performance in this application to a simple weighted average of vertical chords. Finally, results demonstrate horizontal position control using magnetic actuators and an optical observer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

Geometric control of magnetic domain morphology in electrodeposited Ni rich NiPt mesoscopic wires

In this paper, we study the electrodeposited Ni—Pt magnetic wires, exploring the mechanisms by which changes in geometry and composition influence the local magnetic structure. The samples were prepared by electrodeposition, their elemental composition was analyzed by energy dispersive X-ray spectroscopy, and phase analysis was carried out by an X-ray diffraction measurement. Magnetic force microscopy measurements, and magnetic force microscopy measurements in magnetic field were carried out to study the domain morphology of the prepared samples. Magnetization characteristics were measured via vibrating sample magnetometry mode of a superconducting quantum interference device. Here, the results were analyzed and compared with micromagnetic simulations. It is shown that a strong perpendicular magnetic anisotropy is responsible for the characteristic checkerboard-like surface magnetization patterns, which can be tuned by geometrical constriction and Ni content. Understanding these relationships provides insights into the design of magnetic materials with tailored properties for advanced applications, like magnetic sensors.

Binary alloy↗

Colossal Magnetoresistance without Mixed Valence in a Layered Phosphide Crystal

Materials with strong magnetoresistive responses are the backbone of spintronic technology, magnetic sensors, and hard drives. Among them, manganese oxides with a mixed valence and a cubic perovskite structure stand out due to their colossal magnetoresistance (CMR). A double exchange interaction underlies the CMR in manganates, whereby charge transport is enhanced when the spins on neighboring Mn 3+ and Mn 4+ ions are parallel. Prior efforts to find different materials or mechanisms for CMR resulted in a much smaller effect. Here an enormous CMR at low temperatures in EuCd 2 P 2 without manganese, oxygen, mixed valence, or cubic perovskite structure is shown. EuCd 2 P 2 has a layered trigonal lattice and exhibits antiferromagnetic ordering at 11 K. The magnitude of CMR (10(4)%) in as-grown crystals of EuCd 2 P 2 rivals the magnitude in optimized thin films of manganates. In this work, the magnetization, transport, and synchrotron X-ray data suggest that strong magnetic fluctuations are responsible for this phenomenon. The realization of CMR at low temperatures without heterovalency leads to a new regime for materials and technologies related to antiferromagnetic spintronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neural network-based classification and regression of magnetohydrodynamic modes in tokamaks

We present a machine learning-based magnetohydrodynamic (MHD) classifier and regressor that utilizes real or complex-valued 3D magnetic sensor array data to determine neoclassical tearing mode (NTM) onset times in tokamaks with millisecond accuracy. The input dataset consists of poloidal profiles of complex Fourier amplitudes with an n = 1 toroidal mode number from 144 human-labeled ITER Baseline Scenario discharges in the DIII-D tokamak, spanning both tearing-dominated and sawtooth-dominated regimes. Since m, n = 2,1 NTMs frequently emerge alongside sawteeth at the same frequency in this scenario, the focus is on isolating the m = 1 and m = 2 components of the n = 1 MHD mode near the tearing onset. To improve model regularization and prediction stability, singular value decomposition was applied to balance the sawtooth and tearing datasets. The enriched datasets facilitated training neural networks that learn the key distinguishing features of sawtooth and tearing modes in the poloidal profiles of their magnetic amplitude and phase. When the modes occur independently, the networks achieve perfect classification due to the modes’ distinct characteristics and low measurement noise. In the more experimentally relevant case where both modes coexist, the networks maintain exceptional performance across key metrics. Tests on synthetic data with known ground truth demonstrate the superior accuracy of the neural network trained on complex-valued input compared to models using real amplitude, phase, or pseudo-complex data, achieving both a mean time delay and standard deviation below 1 ms. Notably, standard linear regression methods fitting the dominant singular modes to the data closely match the neural network’s performance. Applying these methods across a broad range of H-mode scenarios will enable future studies to systematically identify dominant NTM triggers as scenario-specific variables, paving the way for more effective tearing mode avoidance strategies in future fusion reactor designs.

machine learning↗