Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Untargeted Exometabolomics Provides a Powerful Approach to Investigate Biogeochemical Hotspots with Vegetation and Polygon Type in Arctic Tundra Soils

Rising temperatures in the Arctic have led to the thawing of tundra soils, which is rapidly changing terrain, hydrology, and plant and microbial communities, causing hotspots of biogeochemical activity across the landscape. Despite this, little is known about how nutrient-rich low molecular weight dissolved organic matter (LMW DOM) varies within and across tundra ecosystems. Using a high-resolution nano-liquid chromatography-mass spectrometry (LC/MS) approach, we characterized the composition and availability of LMW DOM from high-centered polygons (HCP) and low-centered polygons (LCP) with Eriophorum angustifolium or Carex aquatilis as the dominant vegetation. Over 3000 unique features (i.e., discrete mass/charge ions) were detected; 521 were identified as differentially abundant between polygonal types and 217 were putatively annotated using high mass accuracy MS data. While polygon type was a strong predictor of LMW DOM composition and availability, vegetation and soil depth were also important drivers. Extensive evidence was found for enhanced microbial processing at the LCP sites, which were dominated by Carex plant species. We detected significant differences between polygon types with varying aboveground landscape features or properties, and hotspots of biogeochemical activity, indicating LMW DOM, as quantified by untargeted exometabolomics, provides a window into the dynamic complex interactions between landscape topography, vegetation, and organic matter cycling in Arctic polygonal tundra soils.

58 GEOSCIENCES↗

Direct detection of dark matter substructure in strong lens images with convolutional neural networks

Strong gravitational lensing is a potential way of uncovering the nature of dark matter, by finding perturbations to images that cannot be accounted for well by modeling the lens galaxy without additional structure, be it subhalos (smaller halos within the smooth lens) or line-of-sight (LOS) halos. Here, we introduce results attempting to infer the presence of substructure from images without requiring an intermediate step in which a smooth model has to be subtracted, using a simple convolutional neural network (CNN). We find that the network is only able to infer the presence of subhalos with greater than 75% accuracy when they have masses of greater than or equal to 5 × 10 9 M ⊙ if they lie within the main lens galaxy. Since less massive foreground LOS halos can have the same effect as higher-mass subhalos, the CNN can probe lower masses in the halo mass function. The accuracy does not improve significantly if we add a population of less massive subhalos. With the expectation of experiments such as Hubble Space Telescope and Euclid yielding thousands of high-quality strong lensing images in the next years, having a way of analyzing images quickly to identify candidates that merit further analysis to determine individual subhalo properties while preventing extensive resources being used for images that would yield null detections could be very useful. By understanding the sensitivity as a function of substructure mass, nondetections could be combined with the information from images with substructure to constrain the cold dark matter scenario, in particular if the sensitivity can be pushed to lower masses.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Computationally Efficient Linear Semi-Lagrangian Scheme for the Advection of Microphysical Variables in Cloud-Resolving Models

An efficient semi-Lagrangian (SL) numerical scheme for the advection of positive-definite microphysical variables in cloud-resolving models is proposed. The scheme is a linear combination of SL schemes of the first and second order. The proposed scheme is compared with two high-order, monotonic, nonlinear Eulerian schemes, in two 2D tests. In the first test, advection of a positive scalar field with large gradients is performed within complicated idealized steering flows. In the second test, a hail storm is simulated using the 2D Hebrew University Cloud Model, describing the interactions between 15 size distributions of different microphysical quantities (each distribution is described by 43 mass bins). The proposed scheme is computationally efficient, has a low numerical diffusion and a high level of mass conservation accuracy, and preserves the sum of multiple advected variables as well as the linear relationships between the advected scalar variables. Although the proposed SL scheme is not exactly positive definite, the negative values and their number, which may appear only in the case of very strong gradients, are negligible. The scheme produces results similar to those of nonlinear Eulerian advection schemes while reducing computation time by approximately a factor of 10.

54 ENVIRONMENTAL SCIENCES↗

The EBLM project – VIII. First results for M-dwarf mass, radius, and effective temperature measurements using CHEOPS light curves

ABSTRACT The accuracy of theoretical mass, radius, and effective temperature values for M-dwarf stars is an active topic of debate. Differences between observed and theoretical values have raised the possibility that current theoretical stellar structure and evolution models are inaccurate towards the low-mass end of the main sequence. To explore this issue, we use the CHEOPS satellite to obtain high-precision light curves of eclipsing binaries with low-mass stellar companions. We use these light curves combined with the spectroscopic orbit for the solar-type companion to measure the mass, radius, and effective temperature of the M-dwarf star. Here, we present the analysis of three eclipsing binaries. We use the pycheops data analysis software to fit the observed transit and eclipse events of each system. Two of our systems were also observed by the TESS satellite – we similarly analyse these light curves for comparison. We find consistent results between CHEOPS and TESS, presenting three stellar radii and two stellar effective temperature values of low-mass stellar objects. These initial results from our on-going observing programme with CHEOPS show that we can expect to have ∼24 new mass, radius, and effective temperature measurements for very low-mass stars within the next few years.

Swayne, M. I.↗

Accuracy of self‐reported weight, height and body mass index among older people in Japan

Aim Weight and height are usually self‐reported in population‐based epidemiological surveys. While the accuracy of self‐reports has been extensively studied in younger populations, less is known in older populations. We investigated the accuracy of self‐reported weight, height and body mass (BMI) in an older cohort in Japan, where overweight/obesity and underweight coexist. Methods We used data from older Japanese adults (≥65 years) participating in the Japan Gerontological Evaluation Study in 2016 to 2017 (7357 men and 9271 women). Self‐report data were linked to objective data obtained from clinical examinations. Results The mean ± standard deviation (SD) age was 74.5 ± 5.8 years, mean ± SD weight, height and BMI were 55.7 ± 10.1 kg, 156.0 ± 8.9 cm and 22.8 ± 3.1, respectively. Results showed high intraclass correlation coefficients for self‐reported and measured values (0.97 for weight; 0.96 for height). While weight/height were overestimated among men (weight by 0.096 kg; height by 0.27 cm) and women (weight by 0.18 kg; height by 0.27 cm), BMI tended to be slightly underestimated (−0.034 kg/m 2 for men; −0.037 kg/m 2 for women). However, the absolute differences between self‐reported and measured values were not negligible; people had a higher risk for both under‐ and overestimation of their BMI category with increasing age. Lower education predicted BMI overestimation, whereas lower income predicted BMI underestimation. Conclusions Overall accuracy of self‐reported body habitus was higher in this cohort of older Japanese compared with previous reports. Nevertheless, misclassification of BMI due to the misreporting of their weight/height was more common among the oldest‐old, as well as those with lower education and income. Geriatr Gerontol Int 2020; 20: 803–810 .

Yazawa, Aki↗

Impact of the equation of state on f - and p - mode oscillations of neutron stars

We investigate the impact of the neutron-star matter equation of state on the f- and p1-mode oscillations of neutron stars obtained within the Cowling approximation and linearized general relativity. The f- and p 1 -mode oscillation frequencies, and their damping times are calculated using representative sets of Skyrme Hartree-Fock and relativistic mean-field models, all of which reproduce nuclear systematics and support 2M ⊙ neutron stars. Our study shows strong correlations between the frequencies of f- and p 1 -modes and their damping times with the pressure of β-equilibrated matter at densities equal to or slightly higher than the nuclear saturation density ρ 0 . Such correlations are found to be almost independent of the composition of the stars. The frequency of the p 1 -mode of 1.4M ⊙ star is strongly correlated with the slope of the symmetry energy L 0 and β-equilibrated pressure at density ρ 0 . Compared to GR calculations, the error in the Cowling approximation for the f-mode is about 30% for neutron stars of low mass, whereas it decreases with increasing mass. Here, the accuracy of the p 1 -mode is better than 15% for neutron stars of maximum mass, and improves for lower masses and higher number of radial nodes. I.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Noise Improvements in Quantum Simulations of sQED using Qutrits

We present an argument for the advantages of using qudits over qubits for scalar Quantum Electrodynamics in $(1+1)$d. We measure the mass gap using an out of time correlator as a function of noise coming from an amplitude damping error channel and a generalized Pauli channel decoherence channel for both qubits and qutrits. For the same error in determination of the mass, the qutrit simulations can tolerate 10 to 100x larger gate noise than a qubit simulations. We find that 20 per-cent accuracy on the mass gap could be possible in the near future with a qutrits but is infeasible using qubits.

Gustafson, Erik↗

Stellar Mass Calibrations for Local Low-mass Galaxies

The stellar masses of galaxies are measured from integrated light via several methods—however, few of these methods were designed for low-mass (M ⋆ ≲ 10 8 M ⊙ ) “dwarf” galaxies, whose properties (e.g., stochastic star formation, low metallicity) pose unique challenges for estimating stellar masses. In this work, we quantify the precision and accuracy at which stellar masses of low-mass galaxies can be recovered using UV/optical/IR photometry. We use mock observations of 469 low-mass galaxies from a variety of models, including both semi-empirical models (GRUMPY and UniverseMachine-SAGA) and cosmological baryonic zoom-in simulations (MARVELous Dwarfs and FIRE-2), to test literature color–M ⋆ /L relations and multiwavelength spectral energy distribution (SED) mass estimators. We identify a list of “best practices” for measuring stellar masses of low-mass galaxies from integrated photometry. We find that literature color–M ⋆ /L relations are often unable to capture the bursty star formation histories (SFHs) of low-mass galaxies, and we develop an updated prescription for stellar mass based on g − r color that is better able to recover stellar masses for the bursty low-mass galaxies in our sample (with ∼0.1 dex precision). SED fitting can also precisely recover stellar masses of low-mass galaxies, but this requires thoughtful choices about the form of the assumed SFH: Parametric SFHs can underestimate stellar mass by as much as ∼0.4 dex, while nonparametric SFHs recover true stellar masses with insignificant offset (−0.03 ± 0.11 dex). Finally, we also caution that noninformative (wide) dust attenuation priors may introduce M ⋆ uncertainties of up to ∼0.6 dex.

de los Reyes, Mithi A. C. [Amherst College, MA (Un↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

Mascon distribution techniques for asteroids and comets

The mass-concentration model is an approach that has been used to model the gravitational fields of irregularly shaped bodies such as asteroids and comets. By this approach, the body is treated as a collection of point masses. The method is conceptually simple, easy to program, valid down to the surface, and capable of modeling arbitrary density heterogeneities. How the mass concentrations are distributed as well as how mass is assigned to these concentrations is, however, nontrivial. These aspects significantly affect the accuracy and efficiency of the gravitational model. In this paper, we frame the distribution process in terms of numerical integration applied to finite volume meshes. We describe a new method using unstructured, curvilinear, finite volume meshes to significantly improve the accuracy of the mass-concentration model. We then compare the accuracy and efficiency of several variations of our distribution technique to those from literature using Asteroid Eros and Bennu as example bodies. Our results show that the mascon model can be as accurate as the analytic polyhedral model at the surface using an equivalent number of computational elements—i.e., mascon to surface facets. We report the improvement in the model’s performance can be mainly attributed to the volume mesh topology while mesh curving can provide modest case-dependent improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

The SRG/eROSITA All-Sky Survey: Dark Energy Survey year 3 weak gravitational lensing by eRASS1 selected galaxy clusters

Context. Number counts of galaxy clusters across redshift are a powerful cosmological probe if a precise and accurate reconstruction of the underlying mass distribution is performed – a challenge called mass calibration. With the advent of wide and deep photometric surveys, weak gravitational lensing (WL) by clusters has become the method of choice for this measurement. Aims. We measured and validated the WL signature in the shape of galaxies observed in the first three years of the Dark Energy Survey (DES Y3) caused by galaxy clusters and groups selected in the first all-sky survey performed by SRG (Spectrum Roentgen Gamma)/eROSITA (eRASS1). These data were then used to determine the scaling between the X-ray photon count rate of the clusters and their halo mass and redshift. Methods. We empirically determined the degree of cluster member contamination in our background source sample. The individual cluster shear profiles were then analyzed with a Bayesian population model that self-consistently accounts for the lens sample selection and contamination and includes marginalization over a host of instrumental and astrophysical systematics. To quantify the accuracy of the mass extraction of that model, we performed mass measurements on mock cluster catalogs with realistic synthetic shear profiles. This allowed us to establish that hydrodynamical modeling uncertainties at low lens redshifts (z < 0.6) are the dominant systematic limitation. At high lens redshift, the uncertainties of the sources’ photometric redshift calibration dominate. Results. With regard to the X-ray count rate to halo mass relation, we determined its amplitude, its mass trend, the redshift evolution of the mass trend, the deviation from self-similar redshift evolution, and the intrinsic scatter around this relation. Conclusions. The mass calibration analysis performed here sets the stage for a joint analysis with the number counts of eRASS1 clusters to constrain a host of cosmological parameters. We demonstrate that WL mass calibration of galaxy clusters can be performed successfully with source galaxies whose calibration was performed primarily for cosmic shear experiments, opening the way for the cluster cosmological exploitation of future optical and NIR surveys like Euclid and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Resolving extreme jet substructure

We study the effectiveness of theoretically-motivated high-level jet observables in the extreme context of jets with a large number of hard sub-jets (up to N = 8). Previous studies indicate that high-level observables are powerful, interpretable tools to probe jet substructure for N ≤ 3 hard sub-jets, but that deep neural networks trained on low-level jet constituents match or slightly exceed their performance. We extend this work for up to N = 8 hard sub-jets, using deep particle-flow networks (PFNs) and Transformer based networks to estimate a loose upper bound on the classification performance. A fully-connected neural network operating on a standard set of high-level jet observables, 135 N-subjetiness observables and jet mass, reach classification accuracy of 86.90%, but fall short of the PFN and Transformer models, which reach classification accuracies of 89.19% and 91.27% respectively, suggesting that the constituent networks utilize information not captured by the set of high-level observables. We then identify additional high-level observables which are able to narrow this gap, and utilize LASSO regularization for feature selection to identify and rank the most relevant observables and provide further insights into the learning strategies used by the constituent-based neural networks. The final model contains only 31 high-level observables and is able to match the performance of the PFN and approximate the performance of the Transformer model to within 2%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical selection bias and projection effects in stacked galaxy cluster weak lensing

ABSTRACT Cosmological constraints from current and upcoming galaxy cluster surveys are limited by the accuracy of cluster mass calibration. In particular, optically identified galaxy clusters are prone to selection effects that can bias the weak lensing mass calibration. We investigate the selection bias of the stacked cluster lensing signal associated with optically selected clusters, using clusters identified by the redMaPPer algorithm in the Buzzard simulations as a case study. We find that at a given cluster halo mass, the residuals of redMaPPer richness and weak lensing signal are positively correlated. As a result, for a given richness selection, the stacked lensing signal is biased high compared with what we would expect from the underlying halo mass probability distribution. The cluster lensing selection bias can thus lead to overestimated mean cluster mass and biased cosmology results. We show that the lensing selection bias exhibits a strong scale dependence and is approximately 20–60 per cent for ΔΣ at large scales. This selection bias largely originates from spurious member galaxies within ±20–60 $h^{-1}\, \rm Mpc$ along the line of sight, highlighting the importance of quantifying projection effects associated with the broad redshift distribution of member galaxies in photometric cluster surveys. While our results qualitatively agree with those in the literature, accurate quantitative modelling of the selection bias is needed to achieve the goals of cluster lensing cosmology and will require synthetic catalogues covering a wide range of galaxy–halo connection models.

79 ASTRONOMY AND ASTROPHYSICS↗