CFD Assessment of Orifice Aspect Ratio and Mass Flow Ratio on Jet Mixing in Rectangular Ducts

Isothermal CFD analysis was performed on axially opposed rows of jets mixing with cross flow in a rectangular duct. Laterally, the jets' centerlines were aligned with each other on the top and bottom walls. The focus of this study was to characterize the effects of orifice aspect ratio and jet-to-mainstream mass flow ratio on jet penetration and mixing. Orifice aspect ratios (L/W) of 4-to-1, 2-to-1, and 1-to-1, along with circular holes, were parametrically analyzed. Likewise, jet-to-mainstream mass flow ratios (MR) of 2.0, 0.5, and 0.25 were systematically investigated. The jet-to-mainstream momentum-flux ratio (J) was maintained at 36 for all cases, and the orifice spacing-to-duct height (S/H) was varied until optimum mixing was attained for each configuration. The numerical results showed that orifice aspect ratio (and likewise orifice blockage) had little effect on jet penetration and mixing. Based on mixing characteristics alone, the 4-to-1 slot was comparable to the circular orifice. The 4-to-1 slot has a smaller jet wake which may be advantageous for reducing emissions. However, the axial length of a 4-to-1 slot may be prohibitively long for practical application, especially for MR of 2.0. The jet-to-mainstream mass flow ratio had a more significant effect on jet penetration and mixing. For a 4-to-1 aspect ratio orifice, the design correlating parameter for optimum mixing (C = (S/H)(sq. root J)) varied from 2.25 for a mass flow ratio of 2.0 to 1.5 for a mass flow ratio of 0.25.

Bain, D. B.↗

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

Effect of Coolant Temperature and Mass Flow on Film Cooling of Turbine Blades

A three-dimensional Navier Stokes code has been used to study the effect of coolant temperature, and coolant to mainstream mass flow ratio on the adiabatic effectiveness of a film-cooled turbine blade. The blade chosen is the VKI rotor with six rows of cooling holes including three rows on the shower head. The mainstream is akin to that under real engine conditions with stagnation temperature = 1900 K and stagnation pressure = 3 MPa. Generally, the adiabatic effectiveness is lower for a higher coolant temperature due to nonlinear effects via the compressibility of air. However, over the suction side of shower-head holes, the effectiveness is higher for a higher coolant temperature than that for a lower coolant temperature when the coolant to mainstream mass flow ratio is 5% or more. For a fixed coolant temperature, the effectiveness passes through a minima on the suction side of shower-head holes as the coolant to mainstream mass flow, ratio increases, while on the pressure side of shower-head holes, the effectiveness decreases with increase in coolant mass flow due to coolant jet lift-off. In all cases, the adiabatic effectiveness is highly three-dimensional.

Garg, Vijay K.↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomas devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1 - X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

Papell, S. Stephen↗

Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomson devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1-X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

Papell, S. S.↗

Tests of a mixed compression axisymmetric inlet with large transonic mass flow at Mach numbers 0.6 to 2.65

A 38.8-cm (15.28-in.) capture diameter model of a mixed-compression axisymmetric inlet system with a translating cowl was designed and tested. The internal contours, designed for Mach number 2.65, provided a throat area of 59 percent of the capture area when the cowl was retracted for transonic operation. Other model features included a boundary-layer removal system, vortex generators, an engine airflow bypass system, cowl support struts, and rotating rakes at the engine face. All tunnel testing was conducted at a tunnel total pressure of about 1 atm (a unit Reynolds number of about 8.53 million/m at Mach number 2.65) at angles of attack from 0 deg to 4 deg. Results for the following were obtained: total-pressure recovery and distortion at the engine face as a function of bleed mass-flow ratio, the effect of bleed and vortex generator configurations on pressure recovery and distortion, inlet tolerance to unstart due to changes in angle of attack or Mach number, surface pressure distributions, boundary-layer profiles, and transonic additive drag. At Mach number 2.65 and with the best bleed configurations, maximum total pressure recovery at the engine face ranged from 91 to 94.5 percent with bleed mass-flow ratios from 4 to 9 percent, respectively, and total-pressure distortion was less than 10 percent. At off-design supersonic Mach numbers above 1.70, maximum total-pressure recoveries and corresponding bleed mass flows were about the same as at Mach number 2.65, with about 10 to 15 percent distortion. In the transonic Mach number range, total pressure recovery was high (above 96 percent) and distortion was low (less than 15 percent) only when the inlet mass-flow ration was reduced 0.02 to 0.06 from the maximum theoretical value (0.590 at Mach number 1.0).

Smeltzer, D. B.↗

Development report, mass flow controller PN 5716068

The design, development, and manufacture of an all mechanical mass flow controller are discussed. A test program was conducted using inert gas as the test medium. The unit controlled the pressure within plus of minus one percent. An analytical method is presented for relating the control pressure error with error in mass flow.

Taylor, W.↗

Fiber optic liquid mass flow sensor and method

A method and apparatus are provided for sensing the mass flow rate of a fluid flowing through a pipe. A light beam containing plural individual wavelengths is projected from one side of the pipe across the width of the pipe so as to pass through the fluid under test. Fiber optic couplers located at least two positions on the opposite side of the pipe are used to detect the light beam. A determination is then made of the relative strengths of the light beam for each wavelength at the at least two positions and based at least in part on these relative strengths, the mass flow rate of the fluid is determined.

Korman, Valentin↗

Real time mass flow computer for Arc Jet Wind Tunnel

Experiments at the Arc Jet Tunnel at Ames Research Center have typical run times of 5-10 sec during which the test model is subjected to an environment simulating reentry into Jupiter. Previous real-time determination of mass flow required off-line manual computations from taped or strip chart data. The present paper describes a computer which provides personnel with real-time computations of mass flow. Using an 8-bit microprocessor and standard TTL interface circuitry, the unit interrogates temperature and pressure instruments with other parameters to compute mass flow.

Vidal, J.↗

Mass flow due to heating in a binary system - Application to U Cephei

The possibility of mass flow due to the heating of the cooler component in a close binary system has been investigated. The heating may be caused by irradiation from the hotter companion or by other mechanisms such as the spacial coincidence of non-linear 'g-mode' oscillations in the cooler star. The 2.4-day period binary U Cep, in which gas streaming has been observed, has been chosen for model calculations. Preliminary results show that such a heating of the lower atmosphere of the cooler star could lead to mass flow at an average rate of 10 to the -9th - 10 to the -7th solar mass per year without the star necessarily filling its critical Roche surface.

Kondo, Y.↗

Mass flow in close binary systems

The manner of mass flow in close binary systems is examined with a special view to the role of the so-called critical Roche (or Jacobian) lobe, taking into consideration relevant physical conditions such as radiation pressure that may affect the restricted three-body problem treatment. The mass does not necessarily flow from component one to component two through the L1 point to form a gaseous ring surrounding the latter. These considerations are applied to X-ray binaries with early-type optical components, such as Cyg X-1 (HDE 226868) and 3U 1700 - 37 (HD 153919). In the two bright close binary systems Beta Lyr and UW CMa, which are believed to be undergoing dynamic mass transfer, recent Copernicus observations show that the gas giving rise to the prominent ultraviolet emission lines surrounds the entire binary system rather than merely component two. Implications of these observations are also discussed.

Kondo, Y.↗

Three-Component Force and Mass-Flow Measurement on a Jet Nacelle

The present report contains three-component forces and mass-flow measurements on a jet nacelle at small inlet-velocity ratios v(sub A)/v(sub o) < 1. The mass-flow measurement on two cross sections of the nacelle demonstrate the local-velocity distribution with varying flow and angle of attack.

Ilgmann, G.↗

Mass flow in close binaries - Results of optical and ultraviolet observations

Observational data provide information regarding mass flow in close binaries. Data about origin, condition, and development of circumstellar matter can also be obtained. The investigations are based on an evaluation and correlation of photometric observations and simultaneously made photoelectric and spectrographic observations in the visible spectral range and, in addition, also on satellite observations in the ultraviolet range. Supplementary information concerning the mass flow in close binaries is obtained on the basis of observations related to the X-ray, infrared, and radio range. Suitable theoretical models are employed to interpret the observational data.

Rahe, J.↗

Calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug

The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

Davis, David O.↗

Calibration of the NASA GRC 16 In. Mass-Flow Plug

The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 in. and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

Davis, David O.↗

Oxygen-Mass-Flow Calibration Cell

Proposed calibration standard for mass flow rate of oxygen based on conduction of oxygen ions through solid electrolyte membrane made of zirconia and heated to temperature of 1,000 degrees C. Flow of oxygen ions proportional to applied electric current. Unaffected by variations in temperature and pressure, and requires no measurement of volume. Calibration cell based on concept used to calibrate variety of medical and scientific instruments required to operate with precise rates of flow of oxygen.

Martin, Robert E.↗