Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass flow meters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multiscale modeling to evaluate proposed space-based Doppler lidar sampling strategies

A proposal has been made to place a pulsed Doppler lidar on a space platform (Huffaker, et al., 1980; Emmitt, 1982) in a low earth orbit (200 to 800 km) to measure the atmospheric winds with a spatial resolution commensurate with the current continental rawinsonde network density - i.e., 300 to 500 km resolution. In the case of the space-based doppler lidar, the full range of space scales applies. Single shot pulses with dimensions of 10 x 1000 meters are used to sample areas 100,000 x 100,000 meters to resolved mass flow structure with wavelength of 1 million meters. Simulation studies, therefore, require an equally broad range of atmospheric models. A general circulation model is appropriate to answer questions regarding the impact of a global wind measuring system upon synoptic forecasts. Since the nominal resolution of the spacebased system is expected to be a few 100's of kilometers, then a numerical model with mesoscale dynamics is required. The meaning of an average Doppler shift within a laser pulse volume must be evaluated with models of turbulent/convective scale motions and aerosol gradients. Examples of how models on all these scales have been applied in an ongoing simulation study are presented. In particular, the uncertainties in a mesoscale wind estimate are separated into those arising from pulse scale variances and those due to sample distribution within a prescribed resolution volume. Trade-offs between accuracy and representativeness are discussed in terms of the model results.

Emmitt, G. D.↗

Initial results from the NASA-Lewis wave rotor experiment

Wave rotors may play a role as topping cycles for jet engines, since by their use, the combustion temperature can be raised without increasing the turbine inlet temperature. In order to design a wave rotor for this, or any other application, knowledge of the loss mechanisms is required, and also how the design parameters affect those losses. At NASA LeRC, a 3-port wave rotor experiment operating on the flow-divider cycle, has been started with the objective of determining the losses. The experimental scheme is a three factor Box-Behnken design, with passage opening time, friction factor, and leakage gap as the factors. Variation of these factors is provided by using two rotors, of different length, two different passage widths for each rotor, and adjustable leakage gap. In the experiment, pressure transducers are mounted on the rotor, and give pressure traces as a function of rotational angle at the entrance and exit of a rotor passage. In addition, pitot rakes monitor the stagnation pressures for each port, and orifice meters measure the mass flows. The results show that leakage losses are very significant in the present experiment, but can be reduced considerably by decreasing the rotor to wall clearance spacing.

Wilson, Jack↗

Initial results from the NASA Lewis wave rotor experiment

Wave rotors may play a role as topping cycles for jet engines, since by their use, the combustion temperature can be raised without increasing the turbine inlet temperature. In order to design a wave rotor for this, or any other application, knowledge of the loss mechanisms is required, and also how the design parameters affect those losses. At NASA LeRC, a 3-port wave rotor experiment operating on the flow-divider cycle, has been started with the objective of determining the losses. The experimental scheme is a three factor Box-Behnken design, with passage opening time, friction factor, and leakage gap as the factors. Variation of these factors is provided by using two rotors, of different length, two different passage widths for each rotor, and adjustable leakage gap. In the experiment, pressure transducers are mounted on the rotor, and give pressure traces as a function of rotational angle at the entrance and exit of a rotor passage. In addition, pitot rakes monitor the stagnation pressures for each port, and orifice meters measure the mass flows. The results show that leakage losses are very significant in the present experiment, but can be reduced considerably by decreasing the rotor to wall clearance spacing.

Wilson, Jack↗

Flow measurement. II.

Cryogenic fluid mass flow measurement methods, noting flow meter calibration

FLOW MEASUREMENT↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Low-rate gas flow meter.

Low rate gas flow meter noting sealing and controlling of piston, differential pressure meter and DC servoamplifier

GAS FLOW↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

Aerodynamics↗

The Face that Launched a Thousand Slips

Helene, (approximately 17.6 kilometers mean radius) is an L4 Trojan co-orbital of Saturn's moon Dione. Its hemisphere features an unusual morphology consisting of broad depressions and a generally smooth surface patterned with streaks and grooves. The streaks appear to be oriented down-gradient, as are the grooves. This pattern suggests intensive mass-wasting as a dominant process on the leading hemisphere. Kilometer-scale impact craters are very sparse on the leading hemisphere other than the degraded kilometer-scale basins defining the overall satellite shape, and many small craters have a diffuse appearance suggesting ongoing mass wasting. Thus mass wasting must dominate surface-modifying processes at present. In fact, the mass wasting appears to have been sufficient in magnitude to narrow the divides between adjacent basins to narrow septa, similar, but in lower relief, to the honeycomb pattern of Hyperion. The prominent groves occur primarily near topographic divides and appear have cut into a broad, slightly lower albedo surface largely conforming to the present topography but elevated a few meters above the smooth surfaces undergoing mass wasting flow. Low ridges and albedo markings on the surface suggest surface flow of materials traveling up to several kilometers. Diffusive mass wasting produces smooth surfaces - such a pattern characterizes most of the low-lying surfaces. The grooves, however, imply that the transport process is advective at those locations where they occur, that is, erosion tends to concentrate along linear pathways separated by divides. In fact, in many places grooves have a fairly regular spacing of 125-160 meters, defining a characteristic erosional scale. Several questions are prompted by the unusual morphology of Helene: 1) What is the nature of the surface materials? 2) Are the transport processes gradual or catastrophic motion from one or a few events? 3) What mechanisms drive mass wasting and groove development? 4) Have the formative processes been active in the recent past? 5) Finally, is the surface accreting or eroding? The smooth character of the leading edge hemisphere of Helene and the dominance of mass wasting suggest that the surface is composed of fine-grained debris, probably dominated by dust-size to small gravel particles. The Lagrangian points of saturnian satellites are locations where planetesimals might have accreted to form co-orbital satellites such as and they may capture ejecta from their master moon. Published models suggest that Helene is a site of net accretion, but we find no extant explanation for the dominance of fine grain sizes for the surface (and probable subsurface) composition of Helene and the other Lagrangian satellites. Observation of the mass wasting tracks on Helene suggests the presence of well-defined streams of debris with low bordering levees that may be depositional features or remnants of the dissected higher surface. Some flows in grazing illumination appear to have a convex cross-section. This mass-flow morphology might be consistent with the occurrence of large-scale flow events, but which might have occurred through rapid emplacement or slow glacier-like creep. On the other hand, small craters appear to have been "softened" by creep-like processes, indicating ongoing mass wasting.

honeycomb pattern of Hyperion↗

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

An Electrical-Type Indicating Fuel Flowmeter

An electrical-type meter has been developed for measuring mass rates of flow of gasoline or other nonconducting fluids. Its temperature dependence is small over a large range and it has no known vibrational or viscosity errors. The maximum temperature rise is less than 5 C. The rates of flow, measurable within 1% with the present instrument, are approximately 100 to 1,000 or more pounds of gasoline per hour when a potentiometer is used, or 100 to 300 pounds per hour when a deflection-type meter is used.

Tozier, Robert E.↗

Software to Control and Monitor Gas Streams

This software package interfaces with various gas stream devices such as pressure transducers, flow meters, flow controllers, valves, and analyzers such as a mass spectrometer. The software provides excellent user interfacing with various windows that provide time-domain graphs, valve state buttons, priority- colored messages, and warning icons. The user can configure the software to save as much or as little data as needed to a comma-delimited file. The software also includes an intuitive scripting language for automated processing. The configuration allows for the assignment of measured values or calibration so that raw signals can be viewed as usable pressures, flows, or concentrations in real time. The software is based on those used in two safety systems for shuttle processing and one volcanic gas analysis system. Mass analyzers typically have very unique applications and vary from job to job. As such, software available on the market is usually inadequate or targeted on a specific application (such as EPA methods). The goal was to develop powerful software that could be used with prototype systems. The key problem was to generalize the software to be easily and quickly reconfigurable. At Kennedy Space Center (KSC), the prior art consists of two primary methods. The first method was to utilize Lab- VIEW and a commercial data acquisition system. This method required rewriting code for each different application and only provided raw data. To obtain data in engineering units, manual calculations were required. The second method was to utilize one of the embedded computer systems developed for another system. This second method had the benefit of providing data in engineering units, but was limited in the number of control parameters.

Arkin, C.↗