Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Scrutinizing entrainment and mass flux closures in shallow cumulus parameterizations using cloud-radar observations and large-eddy simulation (Final Report)

Representing warm, shallow clouds is a challenge for Global Climate Models, which leads to uncertainty in model projections of future climate. Our study was particularly concerned with how climate models represent the effects of shallow, non-precipitating cumulus clouds. Climate models must make certain assumptions when representing low clouds such as how much dry air from outside the cloud is mixed into the warm, moist cloud updraft. This process is called “entrainment” and tends to weaken the cloud updraft and dry out the cloud, compared to a theoretical cloud with no mixing. This project was a joint observational and modeling study to derive estimates of entrainment from field observations and use high-resolution modeling to evaluate the assumptions used in climate model representations of shallow cumulus. Our research took advantage of a wide variety of Department of Energy measurements from fixed climate-monitoring locations over the Southern Great Plains of the U.S. and the in the Eastern North Atlantic, along with short-term field projects (MAGIC, CAP–MBL, ACE–ENA). During the project, the PI maintained regular collaborations with Department of Energy Scientists at Brookhaven and Argonne National Laboratories. The project funded two students, who both obtained their M.S. in Atmospheric Science and are currently in the Atmospheric Science Ph.D. program. Both were lead authors on research papers funded by this grant.

54 ENVIRONMENTAL SCIENCES↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Mass and momentum transport in the Tilted Rocket Rig experiment

Here, high-fidelity large eddy simulations of the inclined Rayleigh-Taylor instability in the Tilted Rocket Rig experimental configuration [Smeeton and Youngs, AWE Report No. O 35/87 (1987)] are performed using a tenth-order compact finite difference code. These simulations are analyzed for spatial distributions of turbulent kinetic energy, turbulent mass flux velocity, species mass fraction flux, species mass fraction variance, and Favre-averaged Reynolds stresses at two time instances, t = 37 ms and t = 52 ms. Additionally, the vertical distribution of the components of the unclosed budget equations over the center of the domain for these quantities are examined. The dominant terms of these budget equations are further decomposed to examine the principal contributions to these terms in each axis. Notably, the principal contribution to the horizontal turbulent mass flux velocity budget is found to be from a term which is commonly neglected in many Reynolds-averaged Navier-Stokes models.

42 ENGINEERING↗

Turbulence and Cloudiness in Cumulus-Topped Marine Boundary Layers

Turbulence and cloudiness in cumulus-topped marine boundary layers are studied using data from the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site. The analysis includes eight periods of nonprecipitating shallow cumulus clouds, spanning 141 h and encompassing 603 individual clouds. On average, the cumulus had bases at 558 m, were 99 m thick, had a chord length of 500 m, and exhibited an hourly base-layer cloudiness of 12%. Changes in cloud fraction were primarily driven by variations in cloud number not chord length. High-resolution Doppler lidar and cloud radar observations were used to estimate updraft and downdraft mass fluxes in the cumulus base layer under both clear and cloudy regions. Cloudy updrafts contributed only ∼23% of the total updraft mass flux at cloud base, indicating that most upward mass flux originated from clear-air eddies. Updraft strength, rather than updraft fraction, was found to predominantly control both clear and cloudy updraft mass fluxes. Cloud-base cloudiness strongly correlated with cloudy updraft mass flux but showed negligible correlation with clear-air updraft mass flux. Clear-air downdraft mass flux exhibited a strong relationship with the ratio of surface buoyancy to inversion strength. Mesoscale analysis revealed that moist patches had greater cloudiness, updraft mass flux, and vertical velocity variance compared to dry patches. Additionally, mesoscale base-layer cloud fraction was highly and significantly correlated with cloudy updraft mass flux in both dry and moist environments. Results presented herein have implications for cumulus parameterization development along with climatological and model evaluation studies conducted at the ENA site.

cumulus clouds↗

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Shallow Cumulus Entrainment Dynamics in a Sheared Environment

Abstract Vertical wind shear has long been known to tilt convective towers and reduce thermal ascent rates. The purpose of this study is to better understand the physical mechanisms responsible for reduced ascent rates in shallow convection. In particular, the study focuses on cloud-edge mass flux to assess how shear impacts mass-flux profiles of both the ensemble and individual clouds of various depths. A compositing algorithm is used to distill large-eddy simulation (LES) output to focus on up- and down-shear cloud edges that are not influenced by complex cloud geometry or nearby clouds. A direct entrainment algorithm is used to estimate the mass flux through the cloud surface. We find that the dynamics on the up- and down-shear sides are fundamentally different, with the entrainment of environmental momentum and dilution of buoyancy being primarily responsible for the reduced down-shear ascent rates. Direct estimates of fluid flow through the cloud interface indicate a counter-shear organized flow pattern that entrains on the down-shear side and detrains on the up-shear side, resulting from the subcloud shear being lifted into the cloud layer by the updraft. In spite of organized regions of entrainment and detrainment, the overall net lateral mass flux remains unchanged with respect to the no shear run, with weak detrainment present throughout cloud depth.

Meteorology & Atmospheric Sciences↗

Updraft and Downdraft Core Size and Intensity as Revealed by Radar Wind Profilers: MCS Observations and Idealized Model Comparisons

This study explores the updraft and downdraft properties of mature stage mesoscale convective systems (MCSs) in terms of draft core width, shape, intensity, and mass flux characteristics. The observations use extended radar wind profiler (RWP) and surveillance radar datasets from the U.S. Department of Energy Atmospheric Radiation Measurement program for midlatitude (Oklahoma, USA) and tropical (Amazon, Brazil) sites. MCS drafts behave qualitatively similar to previous aircraft and RWP cloud summaries. The Oklahoma MCSs indicate larger and more intense convective up- and downdraft cores, and greater mass flux than Amazon MCS counterparts. However, similar size-intensity relationships and draft vertical profile behaviors are observed for both regions. Additional similarities include weak positive correlations between core intensity and core width (correlation coefficient r ~ 0.5), and increases in draft intensity with altitude. A model-observational intercomparison for draft properties (core width, intensity, mass flux) is also performed to illustrate the potential usefulness of statistical observed draft characterizations. Idealized simulations with the Weather Research and Forecasting model aligned with midlatitude MCS conditions are performed at model grid spacings (?x) that range from 4 km to 250 m. It is shown that the simulations performed at ?x = 250 m at similar mature MCS lifecycle stages are those that exhibit draft intensity, width, mass flux, and shape parameter performances best matching with observed properties.

radar, arm, wind profiler, goamazon↗

Characterizing Heat Transfer in sCO 2 Cycle Coolers Utilizing the Wilson Plot Technique

Effective design of coolers can decrease the capital expense of supercritical carbon dioxide (sCO 2 ) power plants. Improved datasets reporting heat transfer from the CO 2 in the cycle cooler allow design engineers to calculate the required length of heat exchanger streams more accurately, thus reducing cooler material and heat exchanger cost. This study considered a shell-and-tube heat exchanger with non-condensing CO 2 on the tube side and water flow on the shell side. The average Nusselt number on the tube side was measured employing the Wilson plot technique for a flow at a Reynolds number, Re, equal to 1×10 5 and for a heat flux to mass flux ratio, Q"/G, ranging from 50 to 350 J/kg. The results indicate that the Nusselt number, Nu, increases as the CO 2 pressure decreases towards the critical point. The results also indicate that Nu increases to maximum at Q"/G = 215 J/kg and then decreases with further increases in Q"/G. The difference in Nu measured between the horizontal and vertical heat exchanger with downward flowing CO 2 is less than the experimental error.

20 FOSSIL-FUELED POWER PLANTS↗

Elucidating the Impact of Flow on Material-Sensitive Critical Heat Flux and Boiling Heat Transfer Coefficients: An Experimental Study with Various Materials

In this work, steady-state internal flow boiling critical heat flux (CHF) experiments were carried out at 10°C inlet subcooling and atmospheric pressure (84 kPa at an altitude of about 5300 feet) with mass flux ranging from 200 to 2,000 kg/m 2 -s on seven tube materials, including the accident-tolerant fuel cladding candidate FeCrAl (C26M) alloy. At a relatively low flow rate, the sensitivity of CHF to different materials was appreciable (the average difference among the tested materials was 19% at 200 kg/m 2 -s). As the absolute CHF differences stayed constant for higher flow rates, the increased flow rate led to reduced relative CHF differences among the tested materials (average relative difference of 15% at 1,000 kg/m 2 -s). FeCrAl alloy claddings that were oxidized under simulated Light Water Reactor (LWR) conditions yielded CHF comparable to as-received FeCrAl alloy cladding, with less than 1.8% difference. Experimental CHF results imply marginal material sensitivity impacts on the departure from nucleate boiling ratio in steady-state nuclear reactor cores. Yet, for accident progression analysis, material sensitivity may hold importance, as boiling behavior variation at low mass flux is appreciable. Macroscopic material parameters (surface wettability, surface roughness, and thermal properties) do not provide a suitable explanation for observed material-sensitive CHFs. Yet, surface roughness and thermal effusivity revealed power and linear relations, respectively, to the nucleate boiling heat transfer coefficients at low mass flux. At high mass flux, material sensitivity on nucleate boiling heat transfer significantly decreased due to the increased shear stress on boiling surface overwhelming material-related boiling implications.

36 MATERIALS SCIENCE↗

A Machine‐Learning‐Assisted Stochastic Cloud Population Model as a Parameterization of Cumulus Convection

Abstract A machine‐learning‐assisted stochastic cloud population model is coupled with the Advanced Research Weather Research and Forecasting (WRF) model to represent fluctuations in the cloud‐base mass flux associated with the life cycles and interactions among cumulus convection cells. In this cloud population model, the size distribution and the associated cloud‐base mass flux of the convective cells are related to their previous state and to the change in the total convective area via a transition function. The convective area tendency in turn is assumed to depend on the cloud‐base mass flux that is resolved by the host WRF model. The transition function is represented by a single hidden‐layer neural network trained by the evolution of convective cell size distributions in a 1‐km grid‐spacing WRF simulation run over the Australian Monsoon region. At every grid point of the host model, the cloud population model predicts the cell size and cloud‐base mass flux distributions from which a random sample of cells is fed to an entraining parcel model that calculates precipitation as well as the associated liquid water potential temperature and total moisture tendencies. These tendencies are averaged over the cells and provided to the host model. Several regional simulations are performed over tropical and midlatitude domains to test this as a potential approach to scale‐aware parameterization. It is shown that such an approach could be a new promising path to simulating realistic precipitation statistics and propagation of precipitation associated with the Madden‐Julian Oscillation while maintaining realistic depictions of the diurnal cycle over both land and ocean.

54 ENVIRONMENTAL SCIENCES↗

Investigating Inherent Numerical Stabilization for the Moist, Compressible, Non‐Hydrostatic Euler Equations on Collocated Grids

This study investigates inherent numerical dissipation due to upwind fluxes and reconstruction strategies for collocated Finite-Volume integration of the Euler equations. Idealized supercell simulations are used without any explicit dissipation. Flux terms are split into: mass flux, pressure, and advected quantities. They are computed with the following upwind strategies: central, advectively upwind, and acoustically upwind. This is performed for third and ninth-order-accurate reconstructions with and without Weighted Essentially Non-Oscillatory limiting. Acoustic-only upwinding for pressure and mass flux terms and advective-only upwinding for advected quantities is the most flexible simplification found. It reduces data movement and computations. Assuming a constant speed of sound in acoustic upwinding gives similar results to using the true speed of sound. Dissipation from upwind adapts automatically to grid spacing, time step, reconstruction accuracy, and flow smoothness. While stability is maintained even at 21st-order spatial accuracy, there is a limit to the spatial order of accuracy for which upwinding alone can create a realizable solution in the conditions of this study. Convex combinations of upwind and central solutions for flux terms also reduced dissipation, but as the central proportion grows, solutions become physically unrealizable. The range of length scales of the kinetic energy spectra can be extended along k −5/3 to smaller spatial scales by reducing dissipation either with higher-order reconstructions or using convex combinations of upwind and central fluxes. However, not all extensions of the length scale range along k −5/3 exhibit physically realizable solutions, even though the spectra appear to be physical.

54 ENVIRONMENTAL SCIENCES↗

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion↗

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Kinetic-Energy–Momentum–Mass 5-Flux of a Baryon Fluid in Bargmann Spacetimes

A Bargmann spacetime is a constrained five-dimensional setting that, while introducing no new physical degrees of freedom beyond those of ordinary four-dimensional spacetime, permits Galilei physics to be expressed with a tensor formalism that respects the distinction between mass and energy while affording the conceptual and technical advantages of a spacetime metric. This framework offers a route to a strong-field ‘Galilei general relativity’ approximating the usual Poincaré general relativity introduced by Einstein. In preparation for modeling core-collapse supernovae, where such an approximation would be useful, this work generalizes the kinetic-energy–momentum–mass 5-flux 𝒯 and its associated spacetime tensor law from a simple fluid of constant particle mass to a baryon fluid whose multiple nuclear species can interconvert rest mass and internal energy. The spacetime tensor law on Bargmann–Galilei spacetime 𝐵𝒢 and its decompositions relative to comoving (‘Lagrangian’) and fiducial (‘Eulerian’) observers are derived in detail. The formalism is rendered more suitable for core-collapse supernova modeling by an extension from strict 𝐵𝒢 to a regime that might be denoted as 𝐵𝒢+: microscopically Poincaré yet macroscopically Galilei. This extension accommodates energy generation by nuclear composition changes and allows comoving energy density and pressure to contribute relative to mass density, while preserving the simplifications of Galilei bulk fluid flow and the streamlined geometry governed by the Bargmann–Galilei spacetime metric.

Cardall, Christian [ORNL] (ORCID:000000020086105X)↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗