Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectrometry analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evolved Gas Analyses of Mudstones from the Vera Rubin Ridge

The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) rover has been essential in understanding volatile-bearing phases in Gale Crater materials. SAM’s evolved gas analysis mass spectrometry (EGA-MS) has detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, and other trace gases, including organic fragments, in many samples. The identity and evolution temperature of evolved gases can support CheMin instrument mineral detection and place constraints on trace volatile-bearing phases or phases difficult to characterize with X-ray diffraction (e.g., amorphous phases). For the past ~500 sols, MSL has been exploring the Vera Rubin Ridge (VRR), which exhibits a striking hematite signature in orbital remote sensing data, in order to understand the depositional and diagenetic history recorded in the rocks and how it relates to the underlying Murray Formation. Four rock samples were drilled, one from the Blunts Point Member (Duluth, DU), one from the Pettegrrove Point Member (Stoer, ST), and two from the Jura Member. The Jura Member displays differences in color, summarized as grey and red, and a key goal was to constrain the cause of this color difference and the associated implications for depositional or post-depositional conditions. To investigate, a grey (Highfield, HF) and a red (Rock Hall, RH) Jura sample were drilled. Here we will give an overview of results from SAM EGA-MS analyses of VRR materials, with some comparisons to analyses of samples of the underlying Murray.

McAdam, A. C.↗

Investigation of the Glen Torridon Clay-Bearing Unit and Overlying Greenheugh Pediment by the Sample Analysis at Mars Instrument Suite

Exploring the Glen Torridon (GT) clay-bearing unit in Gale crater has long been a prime goal for the Mars Science Laboratory (MSL) because of spectral signatures of smectite identified from orbit. Smectite clay minerals can indicate habitable environments [1,2] and possibly facilitate the preservation of organic compounds [e.g., 3-7].Also, sulfate-bearing layers overlie GT and this sequence may record a large-scale change in aqueous conditions overtime [8].The Sample Analysis at Mars (SAM) instrument suitehas been essential in understanding volatile-bearing phases in Gale crater materials. SAM EGA has detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, and other trace gases, including organic fragments, evolved from many samples on heating. The identity and evolution temperature of evolved gases can support mineral detection by CheMin instrument X-ray diffraction (XRD)and place constraints on trace volatile-bearing phases, clay mineral compositions, and X-ray amorphous materials. In GT, SAM analyzed the sample Kilmarie (KM) from the Jura member, Glen Etive (GE), Mary Anning (MA) and Groken (GR)from the Knockfarril Hill member (KHm), Glasgow (GG) and Hutton (HU) from the fractured Intermediate Unit (fIU), and Edinburgh (EB) from the Stimson formation rocks of the Greenheugh Pediment (GP). The Jura, KHm and fIU are all members of the Murray formation. HU was sampled near the basal Siccar Point group (SPg) unconformity between the fIU and GP, in an area that exhibits a brighter tone and differences in geochemistry compared to Murray materials down-section [9,10]. CheMin XRD of most samples (except for HU and EB)showed large abundances of smectite clay minerals (~25-35%) and all samples showed X-ray amorphous materials and relatively low amounts of well-crystalline hematite[11]. SAM evaluated mineralogy through evolved gas analysis mass spectrometry (EGA) while detailed organic chemistry of several samples was examined by pyrolysis gas chromatography mass spectrometry and wet chemistry experiments [12,13].Here we discuss data and interpretations from SAM EGA analyses.

Mars↗

INCORPORATION OF NITROGEN INTO ORGANICS PRODUCED BY FISCHER-TROPSCH TYPE CHEMISTRY

Laboratory simulations have demonstrated that hydrothermal systems have the potential to produce a range of organic compounds through Fischer-Tropsch type (FTT) chemistry. The distribution of products depends on several factors, including the abundance and composition of feedstock molecules, reaction temperature, and the physical and chemical characteristics of catalytic materials included in the reactions. The majority of studies per-formed to date have focused solely on inclusion of CO2 or CO and H2 as the carbon, oxygen and hydrogen sources, which limits the possible products to hydrocarbons, alcohols and carboxylic acids. A few studies have included nitrogen in the form of ammonia, which led to the production of amino acids and nitrogenous bases. Although these demonstrations provide compelling evidence that FTT reactions can produce compounds of interest for the origins of life, such reactions have been conducted under a very limited range of conditions and the synthetic reaction mechanisms have generally not been well-characterized. We have begun a series of laboratory experiments that will incorporate a range of precursor molecules in varying compositions to determine how these variables affect the relative amounts and speciation of life-essential elements in organic molecules produced under FTT conditions. In the present work, we focus on systems containing C, H, O and N. Reaction mixtures contained CO (~60-80 mM), 150 mM ammonium chloride, and water with a native iron catalyst, which also served as a source of H2 through the reduction of water. Three initial experiments were conducted at 110, 154 and 185 °C and heated for several days. Following the reaction, samples were analyzed by gas chromatography-mass spectrometry, direct analysis in real time mass spectrometry and liquid chromatography-mass spectrometry.

A. S. Burton↗

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.↗

Characterization of individual particles in gaseous media by mass spectrometry

An introduction is given to a system for particle analysis by mass spectrometry (PAMS) which employs particle-beam techniques to measure mass spectra on a continuous real-time basis. The system is applied to particles of both organic and inorganic compounds, and the measurements give the chemical characteristics of particles in mixtures and indicate source apportionment. The PAMS system can be used for process control and studying heterogeneous/catalytic reactions in particles, and can be fitted to study the real-time attributes of PAMS.

Sinha, M. P.↗

Two-Step Resonance-Enhanced Desorption Laser Mass Spectrometry for In Situ Analysis of Organic-Rich Environments

A wide diversity of planetary surfaces in the solar system represent high priority targets for in situ compositional and contextual analysis as part of future missions. The planned mission portfolio will inform our knowledge of the chemistry at play on Mars, icy moons, comets, and primitive asteroids, which can lead to advances in our understanding of the interplay between inorganic and organic building blocks that led to the evolution of habitable environments on Earth and beyond. In many of these environments, the presence of water or aqueously altered mineralogy is an important indicator of habitable environments that are present or may have been present in the past. As a result, the search for complex organic chemistry that may imply the presence of a feedstock, if not an inventory of biosignatures, is naturally aligned with targeted analyses of water-rich surface materials. Here we describe the two-step laser mass spectrometry (L2MS) analytical technique that has seen broad application in the study of organics in meteoritic samples, now demonstrated to be compatible with an in situ investigation with technique improvements to target high priority planetary environments as part of a future scientific payload. An ultraviolet (UV) pulsed laser is used in previous and current embodiments of laser desorption/ionization mass spectrometry (LDMS) to produce ionized species traceable to the mineral and organic composition of a planetary surface sample. L2MS, an advanced technique in laser mass spectrometry, is selective to the aromatic organic fraction of a complex sample, which can provide additional sensitivity and confidence in the detection of specific compound structures. Use of a compact two-step laser mass spectrometer prototype has been previously reported to provide specificity to key aromatic species, such as PAHs, nucleobases, and certain amino acids. Recent improvements in this technique have focused on the interaction between the mineral matrix and the organic analyte. The majority of planetary targets of astrobiological interest are characterized by the presence of water or hydrated mineral phases. Water signatures can indicate a history of available liquid water that may have played an important role in the chemical environment of these planetary surfaces and subsurfaces. The studies we report here investigate the influence of water content on the detectability of organics by L2MS in planetary analog samples.

primitive asteroids↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Ultra-Fast Laser Desorption/Laser Ionization Mass Spectrometry for the Organic Analysis of Stardust Sample Return

The STARDUST sample return capsule is anticipated to provide 500-1000 cometary particles 15 m in size. These were collected during the 340 km flyby of Comet P/Wild-2 and impacted the aerogel collection medium at a relative velocity of approx. 6.1 /kms. Hypervelocity impact studies suggest that some fraction of the original organic inventory of collected particles ought to remain intact, although there is likely to be a significant amount of devolatilization and disassociation of the lower mass organic fraction.

Clemett, Simon J.↗

A study of the effects of solid phase reactions on the thermal degradation and ballistic properties of solid propellants

The thermal stability of perchlorate composite propellants was studied at 135 and 170 C. The experimental efforts were concentrated on determining the importance of heterogeneous oxidizer-fuel reactions in the thermal degradation process. The experimental approach used to elucidate the mechanisms by which the oxidizer fuel composites thermally degrade was divided into two parts: (1) keeping the fuel constant and varying the nature of the oxidizers, and (2) holding the oxidizer constant and varying the fuel components. The fuel component primarily utilized in the first phase was polyethylene. Oxidizers included KClO4, KClO3, NH4ClO4 and NH4ClO4 doped with materials such as chlorate, phosphate and arsenate. In the second phase the oxidizer used was primarily NH4ClO4 while the fuels included saturated and unsaturated polybutadiene prepolymers and a series of bonding agents. Techniques employed in the current study include thermogravimetric measurements, differential thermal analysis, infrared, mass spectrometry, electron microscopy, and appropriate wet chemical analysis.

Schmidt, W. G.↗

Cometary and interstellar dust grains - Analysis by ion microprobe mass spectrometry and other techniques

A survey of microanalytical measurements on interplanetary dust particles (IDPs) and interstellar dust grains from primitive meteorites is presented. Ion-microprobe mass spectrometry with its capability to determine isotopic compositions of many elements on a micron spatial scale has played a special role. Examples are measurements of H, N, and O isotopes and refractory trace elements in IDPs; C, N, Mg, and Si isotopes in interstellar SiC grains; and C and N isotopes and H, N, Al, and Si concentrations in interstellar graphite grains.

Zinner, Ernst↗

Light Isotopes and Trace Organics Analysis of Mars Samples with Mass Spectrometry

Precision measurement of light isotopes in Mars surface minerals and comparison of this isotopic composition with atmospheric gas and other, well-mixed reservoirs such as surface dust are necessary to understand the history of atmospheric evolution from a possibly warmer and wetter Martian surface to the present state. Atmospheric sources and sinks that set these ratios are volcanism, solar wind sputtering, photochemical processes, and weathering. Measurement of a range of trace organic species with a particular focus on species such as amino acids that are the building blocks of terrestrial life are likewise important to address the questions of prebiotic and present or past biological activity on Mars. The workshop topics "isotopic mineralogy" and "biology and pre-biotic chemistry" will be addressed from the point of view of the capabilities and limitations of insitu mass spectrometry (MS) techniques such as thermally evolved gas analysis (TEGA) and gas chromatography (GC) surface experiments using MS, in both cases, as a final chemical and isotopic composition detector. Insitu experiments using straightforward adaptations of existing space proven hardware can provide a substantial improvement in the precision and accuracy of our present knowledge of isotopic composition both in molecular and atomic species in the atmosphere and those chemically bound in rocks and soils. Likewise, detection of trace organic species with greatly improved sensitivity from the Viking GCMS experiment is possible using gas enrichment techniques. The limits to precision and accuracy of presently feasible insitu techniques compared to laboratory analysis of returned samples will be explored. The insitu techniques are sufficiently powerful that they can provide a high fidelity method of screening samples obtained from a diverse set of surface locations such as the subsurface or the interior of rocks for selection of those that are the most interesting for return to Earth.

Mahaffy, P.↗

Cytochemical studies of planetary microorganisms - Explorations in exobiology

Analytical methodology using gas chromatography and mass spectrography for improved physiological monitoring of astronauts is developed. Reported research covers the following topics: (1) Chlorination of DNA bases; (2) mass fragmentography; (3) mass spectrometry; (4) urine analysis for metabolic constituents; (5) analysis of natural products by mass spectrometry; (6) computer identification of unknown molecular compounds; (7) fluorescent sorter for cell separation; (8) Mariner Mars 1971 orbital photography; and (9) Viking Lander imagery.

Lederberg, J.↗

In situ mass analysis of particles by surface ionization mass spectrometry

A qualitative study of the application of surface ionization and mass spectrometry to the in situ detection and constituent analysis of atmospheric particles was conducted. The technique consists of mass analysis of ions formed as a result of impingement of a stream of particles on a hot filament where, it is presumed, surface ionization takes place. Laboratory air particles containing K, Ca, and possibly hydrocarbons were detected. Other known particles such as Al2O3, Pb(NO3)2, and Cr2O3 were analyzed by detecting the respective metal atoms making up the particles. In some cases, mass numbers indicative of compounds making up the particles were detected showing surface ionization of particles sometimes leads to chemical analysis as well as to elemental analysis. Individual particles were detected, and it was shown that the technique is sensitive to Al2O3 particles with a mass of a few nanograms.

Lassiter, W. S.↗

Biomark/Organic Analysis with Time-of-Flight Mass Spectrometry

The concept of a Comprehensive 2-Dimensional Gas Chromatography coupled with Time-of-Flight Mass Spectrometry (GCxGC-TOWS) for the analysis of organic compounds has been proven with commercially available instrumentation (LECO Corp). The performance of a GCxGC instrument has been characterized in various stages using two independent breadboard systems. The GCxGC separation systems, including the thermal modulator, have been miniaturized to the size of a benchtop configuration. One breadboard system employs a Flame Ionization Detector (FID), whereas the second breadboard system employs a Time-of-Fight mass spectrometer (TOFWS) as a detection system.

Waite, J. Hunter, Jr.↗