KK Invariant Mass Spectrum in PbPb UPC
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
I will discuss the observational characteristics of black holes and how they compare across the 10^8 range in mass and as a function of luminosity and apparent Eddington ratio. I will concentrate on the broad band spectrum, the timing signatures and the energy budget of these objects. In particular I will stress the similarities and differences in the x-ray spectra and power density spectra of AGN, ultraluminous x-ray sources and galactic black holes as a function of 'state'. I will also discuss the nature of the Fe K line and other diagnostics of the regions near the event horizon.
A variety of processes in the very early Universe can give rise to a population of primordial black holes (PBHs) with an extended mass spectrum. For certain mass spectra of this sort, it has been shown that the evaporation of these PBHs into radiation can drive the universe toward an epoch of cosmological stasis which can persist for a significant number of 𝑒-folds of cosmological expansion. However, in general, the initial mass spectrum which characterizes a population of PBHs at the time of production can subsequently be distorted by processes such as mergers and accretion. Here, in this paper, we examine the effects that these processes have on the spectra that lead to a PBH-induced stasis. Within such stasis models, we find that mergers have only a negligible effect on these spectra within the regime of interest for stasis. We likewise find that the effect of accretion is negligible in many cases of interest. However, we find that the effect of accretion on the PBH mass spectrum is non-negligible in situations in which this spectrum is particularly broad. In such situations, the stasis epoch is abridged or, in extreme cases, does not occur at all. Thus accretion plays a nontrivial role in constraining the emergence of stasis within scenarios which lead to extended PBH mass spectra.
A model for clustering in an expanding universe is developed based on an application of the coagulation equation to the collision and aggregation of bound condensations. While the growth rate of clustering is determined by the rate at which density fluctuations reach the nonlinear regime and therefore depends on the initial fluctuation spectrum, the mass spectrum rapidly approaches a self-similar limiting form. This form is determined by the tidal processes which lead to the merging of condensations, and is not dependent on initial conditions.
Quantifying the similarity between two mass spectra─a known reference mass spectrum and an unidentified sample mass spectrum─is at the heart of compound identification workflows in gas chromatography–mass spectrometry (GC-MS). The reference spectrum most like the sample is assigned as its identification (provided some quantitative similarity threshold is met, e.g., 80%) and thus accurately measuring similarity is essential. Significant research has gone toward developing metrics for this purpose, each of which has attempted to improve upon existing methods by incorporating GC-MS-specific information (e.g., peak ratios or retention times) or adopting various statistical and algorithmic frameworks. While this active development has led to a plethora of similarity metrics with demonstrated value across different contexts, the unfortunate consequence has been confusion surrounding which metric should be used as a global standard. No such metric is currently accepted as the standard method because different metrics have demonstrated optimal performance in different contexts. In this work, we propose an ensemble approach to spectral similarity scoring that combines the collective information from across existing similarity metrics to form an improved, globally representative similarity metric as a step toward establishing a global standard method. In conclusion, the resulting ensemble metrics are evaluated on over 88,000 spectra of varying complexity and demonstrate improved abilities to accurately rank the correct reference spectrum as the top-matching candidate for a sample relative to the rankings generated by individual similarity scores.
The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.
A computer program autonomously manages the calibration of a quadrupole ion mass spectrometer intended for use in monitoring concentrations and changes in concentrations of organic chemicals in the cabin air of the International Space Station. The instrument parameters calibrated include the voltage on a channel electron multiplier, a discriminator threshold, and an ionizer current. Calibration is achieved by analyzing the mass spectrum obtained while sweeping the parameter ranges in a heuristic procedure, developed by mass spectrometer experts, that involves detection of changes in signal trends that humans can easily recognize but cannot necessarily be straightforwardly codified in an algorithm. The procedure includes calculation of signal-to-noise ratios, signal-increase rates, and background-noise-increase rates; finding signal peaks; and identifying peak patterns. The software provides for several recovery-from-error scenarios and error-handling schemes. The software detects trace amounts of contaminant gases in the mass spectrometer and notifies associated command- and-data-handling software to schedule a cleaning. Furthermore, the software autonomously analyzes the mass spectrum to determine whether the parameters of a radio-frequency ramp waveform are set properly so that the peaks of the mass spectrum are at expected locations.
Relativistic jets of radio galaxies (RGs) are possible sources of ultra-high-energy cosmic rays (UHECRs). Recent studies combining relativistic hydrodynamic simulations with Monte Carlo particle transport have demonstrated that UHECRs can be accelerated to energies beyond 10 20 eV through shocks, turbulence, and relativistic shear in jet-induced flows of Fanaroff–Riley type RGs. The resulting time-asymptotic UHECR spectrum is well modeled by a double power law with an “extended” exponential cutoff, primarily shaped by relativistic shear acceleration. In this study, we adopt this novel source spectrum and simulate the propagation of UHECRs from nearby RGs using the CRPropa code. We focus on Virgo A (Vir A), Centaurus A (Cen A), Fornax A (For A), and Cygnus A (Cyg A), expected to be the most prominent UHECR sources among RGs. We then analyze the energy spectrum and mass composition of UHECRs arriving at Earth. We find that, due to the extended high-energy tail in the source spectrum, UHECRs from Vir A, which has a higher Lorentz factor, exhibit a higher flux at the highest energies and a lighter mass composition at Earth compared to those from Cen A and For A with lower Lorentz factors. Despite Cyg A having an even higher Lorentz factor, the large distance limits its contribution. With a small number of nearby prominent RGs, our findings suggest that if RGs are the major sources of UHECRs, the energy spectrum and mass composition of observed UHECRs would exhibit hemispheric differences between the Northern and Southern skies at the highest energies.
The early growth of planetesimals by mutual direct collisions is numerically simulated with a Monte Carlo technique to show how planetesimals with specific mass and velocity distributions evolve into a full-size planet. Four types of collisions are taken into account: rebound, erosion, catastrophic break-up, and coagulation. It is shown that evolution of mass-distribution spectrum is expressed by an inverse power relation. It is also suggested that whether or not a planetesimal can survive catastrophic collision is primarily dependent on mean relative velocity and mechanical properties of planetesimals. It is necessary for the early growth of rocky (basaltic) materials that mean relative velocity be much smaller than 0.1 km/s. Otherwise it is necessary to introduce something like nucleating agents (such as iron bodies which have plastic properties at temperatures higher than 200 K) for the formation of terrestrial planets.
The physical properties of the 148 molecular clouds found in a CO survey of regions around 34 young open clusters have been examined. Expressions are given for the cloud size spectrum and the mass spectrum. The mass-radius relation implies that clouds of all size larger than a few pc have about the same mean volume density. Power laws with slopes of 0.6 and 3 describe, respectively, the relations of CO linewidth and cloud mass to cloud size. The clouds are distinctly nonspherical and appear to be randomly oriented with respect to the Galactic plane. The observations can be explained by a model for molecular clouds in which clouds are ensembles of dense clumps of gas. Based on such a model, it is shown that molecular clouds are perturbed on a time scale short compared to the time required for them to reestablish virial equilibrium.
We calculate the mass spectrum and the structure of the positronium system at a strong coupling in a basis light-front approach. We start from the light-front QED Hamiltonian and retain one dynamical photon in our basis. We perform the fermion mass renormalization associated with the nonperturbative fermion self-energy correction. We present the resulting mass spectrum and wave functions for the selected low-lying states. Next, we apply this approach to QCD and calculate the heavy meson system with one dynamical gluon retained. We illustrate the obtained mass spectrum and wave functions for the selected low-lying states.
An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).
An amplitude analysis of B − → D − D 0 K S 0 decays is performed using proton-proton collision data, corresponding to an integrated luminosity of 9 fb − 1 , collected with the LHCb detector at center-of-mass energies of 7, 8, and 13 TeV. A resonant structure of spin-parity 0 + is observed in the D 0 K S 0 invariant-mass spectrum with a significance of 5.3 σ . The mass and width of the state, modeled with a Breit-Wigner line shape, are determined to be 2883 ± 11 ± 8 MeV / c 2 and 87 − 47 + 22 ± 17 MeV , respectively, where the first uncertainties are statistical and the second systematic. These properties and the quark content are consistent with those of the open-charm tetraquark candidate T c s 0 * ( 2870 ) 0 observed previously in the D + K − final state of the B − → D − D + K − decay. This result confirms the existence of the T c s 0 * ( 2870 ) 0 state in a new decay mode. The T c s 1 * ( 2900 ) 0 state, reported in the B − → D − D + K − decay, is also searched for in the D 0 K S 0 invariant-mass spectrum of the B − → D − D 0 K S 0 decay, without finding evidence for it. © 2025 CERN, for the LHCb Collaboration 2025 CERN
Disclosed herein are methods for tracking solutions, (e.g., reaction conditions in solutions). In some embodiments, the method comprises: contacting a first lanthanide-chelator complex to a first solution to generate a first barcoded solution, wherein the first lanthanide-chelator complex comprises a first lanthanide chelated by a first chelator; contacting a second lanthanide-chelator complex to a second solution to generate a second barcoded solution, wherein the second lanthanide-chelator complex comprises a second lanthanide chelated by a second chelator; mixing the first barcoded solution and the second barcoded solution to form one or more mixtures; and identifying the first lanthanide ions in the mass spectrum and the second lanthanide ions in the mass spectrum to track the condition of each of the one or more mixtures.
We investigate Higgs Parity unification — a realization of SO(10) grand unification based on the Higgs Parity mechanism in which the Standard Model (SM) Higgs resides in a spinor representation. The theory has an intermediate left-right symmetric stage where the SU(2)R symmetry breaking scale is fixed by the vanishing of the SM Higgs quartic coupling. The strong CP problem is solved by parity. Gauge coupling unification successfully predicts αs(MZ) to within 1%. The spinor Higgs naturally leads to a seesaw origin for SM flavor observables. We identify a novel mechanism where large mixing of third generation fermions with additional heavy vector-like fermions accounts for the anarchical nature of the PMNS matrix and the lack of hierarchy in the neutrino mass spectrum, relative to the up-quarks. A fit to quark and lepton masses and mixings, with a minimal parameter set, predicts 1) A testable relation between the top quark mass and αs(MZ) which is about (1 – 2)σ from current best fit values, 2) The order of magnitude of the baryon asymmetry of the universe, via leptogenesis from second-generation right-handed neutrino decays. 3) The proton decay and the neutron EDM are likely observable in next generation experiments, and 4) A normal ordered neutrino mass spectrum where 0νββ decay and the mass of the lightest neutrino are out of reach of next generation experiments.
A statistically complete sample of galaxy clusters is presented which also has complete X-ray temperature information. Using this sample, the cluster bolometric luminosity and temperature functions are derived. The temperature function constrains the shape and amplitude of the mass fluctuation power spectrum. For a power law, i.e., with the fluctuation power spectrum proportional to k exp n, n = -(1.7 + 0.65, - 0.35), and an amplitude is obtained which implies that the rms value of delta-M/M is 0.59 + or - 0.02 on a scale of 8/h Mpc at the present epoch.
The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.