Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sierra/SolidMechanics Verification Report

This document presents the Sierra/SolidMechanics (Sierra/SM) verification plan. This plan centers on the tests in the Sierra/SM verification test suite, a subset of which are documented in the Sierra/SM Verification Tests Manual. Most of these tests are run nightly with the Sierra/SM code suite, and the results of the tests are checked against analytic solutions. For each of the tests presented in the Verification Tests Manual, the test setup, a description of the analytic solution, and comparison of the Sierra/SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This verification plan discusses these various types of tests and what they mean for Sierra/SM verification. Many other activities also contribute to Sierra/SM quality. These address code and solution quality and range from low-level unit tests, run nightly, up to full-fidelity acceptance tests, used to verify release stability. This acceptance test suite checks that new versions of Sierra/SM continue to yield the same answers for high-resolution analyst problems. Further code quality measures include an extensive suite of intermediate-size regression tests and automated nightly code quality checks. While these additional activities do not fall under a strict definition of verification, they greatly add to the quality, stability, and reliability of Sierra/SM, and are discussed here as well.

97 MATHEMATICS AND COMPUTING↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

Python Measurement-Informed Modelling Method (PythonMIMM) v1.02

This Python program implements the calculations for electrical energy efficiency and electrical losses in the paper "Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings" (https://www.sciencedirect.com/science/article/abs/pii/S0306261921015658). The inputs are metered voltage, current, or power data of meters located throughout the DC system. In the absence of metered data, the user must input some other information about the building such as the types of power converters or wire lengths. The program will build a loss model of the DC system based on metered data and electrical information. It will also generate an equivalent AC system and determine the losses and efficiency.

Gerber, Daniel [Lawrence Berkeley National Laborat↗

Supervised extraction of near-complete genomes from metagenomic samples: A new service in PATRIC

Large amounts of metagenomically-derived data are submitted to PATRIC for analysis. In the future, we expect even more jobs submitted to PATRIC will use metagenomic data. One in-demand use case is the extraction of near-complete draft genomes from assembled contigs of metagenomic origin. The PATRIC metagenome binning service utilizes the PATRIC database to furnish a large, diverse set of reference genomes. We provide a new service for supervised extraction and annotation of high-quality, near-complete genomes from metagenomically-derived contigs. Reference genomes are assigned to putative draft genome bins based on the presence of single-copy universal marker roles in the sample, and contigs are sorted into these bins by their similarity to reference genomes in PATRIC. Each set of binned contigs represents a draft genome that will be annotated by RASTtk in PATRIC. A structured-language binning report is provided containing quality measurements and taxonomic information about the contig bins. The PATRIC metagenome binning service emphasizes extraction of high-quality genomes for downstream analysis using other PATRIC tools and services. Due to its supervised nature, the binning service is not appropriate for mining novel or extremely low-coverage genomes from metagenomic samples.

59 BASIC BIOLOGICAL SCIENCES↗

Qualification and Re-Qualification of NDA Instruments

Non-Destructive Assay (NDA) instruments are a large component of nuclear material (NM) measurement at LANL. Nuclear Material Control and Accountability Group (SAFE-NMCA) personnel in the Safeguards Division are responsible for oversight of the instruments used for material accountability measurements. It is the responsibility of SAFE-NMCA to ensure that all instruments are operating as expected and can produce quality measurements to provide assurance that requirements of the DOE approved NMCA Plan are being met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating coherent loss in superconducting circuits using molecular self-assembled monolayers

In planar superconducting circuits, decoherence due to materials imperfections, especially two-level-system (TLS) defects at different interfaces, is a primary hurdle for advancing quantum computing and sensing applications. Traditional methods for mitigating TLS loss, such as etching oxide layers at metal and substrate interfaces, have proven to be inadequate due to the persistent challenge of oxide regrowth. In this work, we introduce a novel approach that employs molecular self-assembled monolayers (SAMs) to chemically bind at different interfaces of superconducting circuits. This technique is specifically tested here on coplanar waveguide (CPW) resonators, in which this method not only impedes oxide regrowth after surface etching but can also tailors the dielectric properties at different resonators interfaces. The deployment of SAMs results in a consistent improvement in the measured quality factors across multiple resonators, surpassing those with only oxide-etched resonators. The efficiency of our approach is supported by microwave measurements of multiple devices conducted at millikelvin temperatures and correlated with detailed X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) characterizations of SAM-passivated resonators. The compatibility of SAMs materials with the established fabrication techniques offers a promising route to improve the performance of superconducting quantum devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical Behavior of Low-Amplitude Power System Point-on-Wave Measurements

The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Axion Dark Matter EXperiment 2A Cavity Characterization

The axion is a highly motivated dark matter candidate for its capacity to solve the strong CP problem in quantum chromodynamics. To detect the axion, the 2A phase of the Axion Dark Matter EXperiment (ADMX) utilizes four identical cylindrical resonant cavities that can detect the photons converted from axions in a strong magnetic field. We found the quality factors for various tunings in cavity D, and we also learned that the piezo motors are not currently equipped to handle cryogenic temperatures. However, the measured quality factors are much more promising than those shown in the last 2A cooldown, improving by about a factor of five.

Maglione, Diego↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Microcomputed X-Ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.

36 MATERIALS SCIENCE↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

Added value of site load measurements in probabilistic lifetime extension: a Lillgrund case study

Site-specific fatigue estimation is an essential part of wind turbine lifetime extension, with various methods depending on data availability. The present study compares probabilistic lifetime extension assessment results for rotor blades with and without load measurements. It also addresses two key questions in such assessments: the applicability of the Frandsen model for estimating waked turbulence under complex and mixed wake conditions and the extrapolation of mid-term data over longer time periods. The case study wind turbine is SWT-2.3-93, located at the edge of the Lillgrund wind farm, situated in the Øresund Strait between Denmark and Sweden. The turbine is extensively instrumented, with 5 years of data available from its supervisory control and data acquisition (SCADA) system. Although the Frandsen turbulence estimates deviate in a different manner from measurements at below- and above-rated mean wind speeds, the model remains a conservative approach for fatigue load prediction and reliability. In the current case study, the site-specific assessment using strain gauge measurements yields a 33 % higher annual fatigue reliability index after 35 years compared to a scenario based on the Frandsen estimation combined with ambient environmental data and a generic aeroelastic model. The results also demonstrate that the sensitivity of fatigue reliability to load uncertainty is negligible when load measurements are used directly but relatively high when relying on the Frandsen model in combination with a generic aeroelastic model. Overall, the high variability of the lifetime extension in different scenarios of data availability and accuracy shows the importance and added value of high-quality measurements combined with wind-farm-level SCADA and a model updated in real time (digital twins).

17 WIND ENERGY↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of Patient-Reported Outcome Utilization Within National Clinical Trials Network Cooperative Group Radiation Oncology Trials Over the Past 2 Decades

When treating cancer, both quantity and quality of life are valuable, though oncology trials have long placed greater emphasis on the former. The goal of this work was to evaluate how patient-reported outcomes (PROs) have been incorporated into radiation therapy trials within the National Clinical Trials Network over the last 2 decades to measure quality of life and to assess how PRO data have been disseminated in publications upon trial conclusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗