Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of the Rotor Systems Research Aircraft calibrated rotor loads measurement system

The compound Rotor Systems Research Aircraft (RSRA) is designed to make high accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for any errors and to ensure that measurement system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis has been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight, and analytical methods have been devised to eliminate its effects on calibration data. Flight tests confirmed that the calibrated rotor loads measurement system performs as expected in flight, and that it can dependably make direct measurements of fuselage vertical drag in hover.

Acree, C. W., Jr.↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

Computer Generated Hologram System for Wavefront Measurement System Calibration

Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.

Olczak, Gene↗

Icing research tunnel rotating bar calibration measurement system

In order to measure icing patterns across a test section of the Icing Research Tunnel, an automated rotating bar measurement system was developed at the NASA Lewis Research Center. In comparison with the previously used manual measurement system, this system provides a number of improvements: increased accuracy and repeatability, increased number of data points, reduced tunnel operating time, and improved documentation. The automated system uses a linear variable differential transformer (LVDT) to measure ice accretion. This instrument is driven along the bar by means of an intelligent stepper motor which also controls data recording. This paper describes the rotating bar calibration measurement system.

Gibson, Theresa L.↗

Icing Research Tunnel rotating bar calibration measurement system

In order to measure icing patterns across a test section of the Icing Research Tunnel, an automated rotating bar measurement system was developed at the NASA Lewis Research Center. In comparison with the previously used manual measurement system, this system provides a number of improvements: increased accuracy and repeatability, increased number of data points, reduced tunnel operating time, and improved documentation. The automated system uses a linear variable differential transformer (LVDT) to measure ice accretion. This instrument is driven along the bar by means of an intelligent stepper motor which also controls data recording. This paper describes the rotating bar calibration measurement system.

Gibson, Theresa L.↗

Miniaturization of flight deflection measurement system

A flight deflection measurement system is disclosed including a hybrid microchip of a receiver/decoder. The hybrid microchip decoder is mounted piggy back on the miniaturized receiver and forms an integral unit therewith. The flight deflection measurement system employing the miniaturized receiver/decoder can be used in a wind tunnel. In particular, the miniaturized receiver/decoder can be employed in a spin measurement system due to its small size and can retain already established control surface actuation functions.

Fodale, Robert↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

New Gear Transmission Error Measurement System Designed

The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

Oswald, Fred B.↗

Rotating Rake Turbofan Duct Mode Measurement System

An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

Sutliff, Daniel L.↗

Infrared/Ultrasonic Position-Measuring System

System for measuring positions of sensors at designated points on body suit developed. Measuring system, body suit, and sensors incorporated into interactive virtual-reality system, wherein they provide feedback data on positions and orientations of various parts of wearer's body. Based on straightforward concept of computating three-dimensional coordinates of sensor from simultaneous measurements of distances of sensor from three locations, coordinates of which known.

Roberson, Ricky J.↗

Mass measurement systems and related methods for measuring mass of solids within a liquid

A measurement system includes a vessel for containing a fluid and at least one solid material and a probe assembly for disposing partially into the fluid within the vessel. The probe assembly includes a hollow tube having an open lower longitudinal end and at least one pressure sensor within the hollow tube, the at least one pressure sensor configured to measure pressures of the fluid within the hollow tube at at least two different elevations. A method of measuring a mass of suspended solids within a fluid, the method includes receiving pressure measurements representing two different elevations of the fluid within a hollow tube and substantially free of the suspended solids and based at least partially on the received pressure measurements, determining a mass of the suspended solids.

Galbreth, Gregory G.↗

Calibration of the ER-2 meteorological measurement system

The Meteorological Measurement System (MMS) on the high altitude ER-2 aircraft was developed specifically for atmospheric research. The MMS provides accurate measurements of pressure, temperature, wind vector, position (longitude, latitude, altitude), pitch, roll, heading, angle of attack, angle of sideslip, true airspeed, aircraft eastward velocity, northward velocity, vertical acceleration, and time, at a sample rate of 5/s. MMS data products are presented in the form of either 5 or 1 Hz time series. The 1 Hz data stream, generally used by ER-2 investigators, is obtained from the 5 Hz data stream by filtering and desampling. The method of measurement of the meteorological parameters is given and the results of their analyses are discussed.

Bowen, Stuart W.↗

On system measurement and identification.

System measurement and identification, considering stochastic transformation between input and output functions, noting connection with radio communication problems

RADIO COMMUNICATION↗

Microgravity Acceleration Measurement System

Microgravity Acceleration Measurement System (MAMS) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

Foster, William↗