Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

LANL MPCL Measurement System Analysis: AMPTEC 630ES Igniter Tester / Ohmmeter

This comprehensive analysis aimed to evaluate the measurement capability of the AMPTEC 630ES Explosive Safety Igniter Tester, a critical tool for organizations engaged in the measurement of High Explosive components and related Electro-Explosive devices. With a history of notable calibration issues involving specific model numbers, the Metrology Program and Calibration Laboratory (MPCL) initiated an extensive Measurement System Analysis. The analysis's primary focus was to thoroughly quantify the various sources of measurement variability intrinsic to the calibration process. It centered on two pivotal aspects: repeatability (the variation observed when the same operator uses the same instrument) and reproducibility (the variation seen when different operators perform measurements). A secondary objective was to determine whether equipment usage and age had any impact on the instrument's performance.

47 OTHER INSTRUMENTATION↗

Carbon Dioxide Flux Measurement System (CO2FLX) Instrument Handbook

The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The fluxes are obtained by the eddy covariance technique, which computes the flux as the mean product of the vertical wind component with CO2 and H2O densities, or estimated virtual temperature. A three-dimensional sonic anemometer is used to obtain the orthogonal wind components and the virtual (sonic) temperature. An infrared gas analyzer is used to obtain the CO2 and H2O densities. A separate sub-system also collects half-hour average measures of meteorological and soil variables from separate 4-m towers.

54 ENVIRONMENTAL SCIENCES↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

An in situ shearing x-ray measurement system for exploring structures and dynamics at the solid–liquid interface

Revealing interfacial structure and dynamics has been one of the essential thematic topics in material science and condensed matter physics. Synchrotron-based x-ray scattering techniques can deliver unique and insightful probing of interfacial structures and dynamics, in particular, in reflection geometries with higher surface and interfacial sensitivity than transmission geometries. We demonstrate the design and implementation of an in situ shearing x-ray measurement system, equipped with both inline parallel-plate and cone-and-plate shearing setups and operated at the advanced photon source at Argonne National Laboratory, to investigate the structures and dynamics of end-tethered polymers at the solid-liquid interface. With a precise lifting motor, a micrometer-scale gap can be produced by aligning two surfaces of a rotating upper shaft and a lower sample substrate. A torsional shear flow forms in the gap and applies tangential shear forces on the sample surface. The technical combination with nanoscale rheology and the utilization of in situ x-ray scattering allow us to gain fundamental insights into the complex dynamics in soft interfaces under shearing. In this work, we demonstrate the technical scope and experimental capability of the in situ shearing x-ray system through the measurements of charged polymers at both flat and curved interfaces upon shearing. Furthermore, through the in situ shearing x-ray scattering experiments integrated with theoretical simulations, we aim to develop a detailed understanding of the short-range molecular structure and mesoscale ionic aggregate morphology, as well as ion transport and dynamics in soft interfaces, thereby providing fundamental insight into a long-standing challenge in ionic polymer brushes with a significant technological impact.

36 MATERIALS SCIENCE↗

3013 Inner Container Closure Weld Region (ICCWR) Characterization by Wide Area 3D Measurement System (WAMS) Analysis (FY21 Progress Report)

As part of the 3013 Surveillance Program, through-wall penetration from stress corrosion cracking (SCC) of the 3013 inner containers has been identified as the most credible condition for failure withing the 50- years lifetime. Chlorides contained in Pu-bearing material, together with intra-canister humidity levels, metallurgical conditions, and internal stresses have been found to produce corrosion in the Inner Container Closure Weld Region (ICCWR) of the 3013 canister system. A Laser Confocal Microscope (LCM) is used as part of the 3013 Surveillance Program protocol to identify the prevalence of corrosion and corrosionrelated cracking in the ICCWR2. With the LCM, a close visual examination is made of the ICCWR surface along with measurements of corrosion-related features. LCM inspections produce immense amounts of image data that is time intensive to analyze. There is also a 9-year backlog of images, with approximately 49 canisters that must be evaluated. To expedite data analysis and reduce the amount of generated data, a Wide Area 3D Measurement System (WAMS) microscope has been added to the examination protocol. Although WAMS is a lower resolution microscope, small features of interest can be still identified. The advantage of collecting data for the full circumference using the WAMS is that it can take about 1/16 of the time needed with the LCM. Both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS is an efficient system for screening and identification of corrosion features while the LCM can be utilized to obtain higher resolution images areas identified by the WAMS. This report explains and justifies the data collection methods used with the WAMS. It includes a summary of the data generated by WAMS in FY21. The goals set for data collection in FY21 were met. A total of twenty-two DE’s were imaged, and analysis was carried out on eleven samples. The analyzed samples showed large numbers of potential cracks and pits distributed throughout the surfaces. Lastly, to explain the advantages of the WAMS, its capabilities were compared to those of a simpler microscope. Micrographs of the samples imaged in FY21 and those analyzed are included in the appendices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wide Area 3D Measurement System for Analysis of 3013 Inner Container Closure Weld Region

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR, a laser confocal microscope (LCM) is used to perform close visual examination of the surface and to measure corrosion features on the surface. However, in FY20, the introduction of the Wide Area 3D Measurement System (WAMS) was tested as a method for faster inspection of the ICCWR. Optimization of the WAMS parameters for data collection was carried out using a generic tear-drop type sample containing large and fine Stress Corrosion Cracking (SCC) fractures and high resolution images were compared to the image obtained with the LCM. Although the image with the LCM shows higher resolution than the WAMS images, the small features can be still identified in the WAMS images. The advantage of collecting data for the full circumference using the WAMS is that it can take about a week to complete, which represents 1/16 of the time needed with the LCM. Nonetheless, both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS can be utilized to obtain images for faster screening or identification of corrosion features on the surface while the LCM can be utilized to obtain higher resolution images of those areas identified by the WAMS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements and Model Improvement: Insight into NWP Model Error Using Doppler Lidar and Other WFIP2 Measurement Systems

Abstract Doppler-lidar wind-profile measurements at three sites were used to evaluate NWP model errors from two versions of NOAA’s 3-km-grid HRRR model, to see whether updates in the latest version 4 reduced errors when compared against the original version 1. Nested (750-m grid) versions of each were also tested to see how grid spacing affected forecast skill. The measurements were part of the field phase of the Second Wind Forecasting Improvement Project (WFIP2), an 18-month deployment into central Oregon–Washington, a major wind-energy-producing region. This study focuses on errors in simulating marine intrusions, a summertime, 600–800-m-deep, regional sea-breeze flow found to generate large errors. HRRR errors proved to be complex and site dependent. The most prominent error resulted from a premature drop in modeled marine-intrusion wind speeds after local midnight, when lidar-measured winds of greater than 8 m s −1 persisted through the next morning. These large negative errors were offset at low levels by positive errors due to excessive mixing, complicating the interpretation of model “improvement,” such that the updates to the full-scale versions produced mixed results, sometimes enhancing but sometimes degrading model skill. Nesting consistently improved model performance, with version 1’s nest producing the smallest errors overall. HRRR’s ability to represent the stages of sea-breeze forcing was evaluated using radiation budget, surface-energy balance, and near-surface temperature measurements available during WFIP2. The significant site-to-site differences in model error and the complex nature of these errors mean that field-measurement campaigns having dense arrays of profiling sensors are necessary to properly diagnose and characterize model errors, as part of a systematic approach to NWP model improvement. Significance Statement Dramatic increases in NWP model skill will be required over the coming decades. This paper describes the role of major deployments of accurate profiling sensors in achieving that goal and presents an example from the Second Wind Forecast Improvement Program (WFIP2). Wind-profile data from scanning Doppler lidars were used to evaluate two versions of HRRR, the original and an updated version, and nested versions of each. This study focuses on the ability of updated HRRR versions to improve upon predicting a regional sea-breeze flow, which was found to generate large errors by the original HRRR. Updates to the full-scale HRRR versions produced mixed results, but the finer-mesh versions consistently reduced model errors.

Meteorology & Atmospheric Sciences↗

Estimating turbulent energy flux vertical profiles from uncrewed aircraft system measurements: exemplary results for the MOSAiC campaign

This study analyzes turbulent energy fluxes in the Arctic atmospheric boundary layer (ABL) using measurements with a small uncrewed aircraft system (sUAS). Turbulent fluxes constitute a major part of the atmospheric energy budget and influence the surface heat balance by distributing energy vertically in the atmosphere. However, only few in situ measurements of the vertical profile of turbulent fluxes in the Arctic ABL exist. The study presents a method to derive turbulent heat fluxes from DataHawk2 sUAS turbulence measurements, based on the flux gradient method with a parameterization of the turbulent exchange coefficient. This parameterization is derived from high-resolution horizontal wind speed measurements in combination with formulations for the turbulent Prandtl number and anisotropy depending on stability. Measurements were taken during the MOSAiC (Multidisciplinary drifting Observatory for the Study of Arctic Climate) expedition in the Arctic sea ice during the melt season of 2020. For three example cases from this campaign, vertical profiles of turbulence parameters and turbulent heat fluxes are presented and compared to balloon-borne, radar, and near-surface measurements. The combination of all measurements draws a consistent picture of ABL conditions and demonstrates the unique potential of the presented method for studying turbulent exchange processes in the vertical ABL profile with sUAS measurements.

54 ENVIRONMENTAL SCIENCES↗

How Representative Are Uncrewed Aircraft System Measurements of the Convective Boundary Layer?

Abstract Uncrewed aircraft systems (UAS) demonstrate significant potential for filling data gaps in the atmospheric boundary layer. However, the extent to which UAS observations—typically vertical profiles taken over 15 min—are representative of the boundary layer as a whole remains poorly characterized. Using large eddy simulations (LES) of the daytime convective boundary layer (CBL), we quantify random errors in UAS measurements that occur due to insufficient statistical convergence of the time average to the true ensemble mean. Random errors in first‐order moments increase as the CBL becomes increasingly unstable, and are largest near the surface for most quantities. Errors are on the order of 2–6 m for wind speed, 15–60 for wind direction, 0.2–3 K for potential temperature, and 0.1–1 g for specific humidity, with errors in turbulent fluxes on the order of 50%–100%. Sampling strategies that mitigate random errors are discussed in light of our results.

Greene, Brian R. [Now at Verisk Extreme Event Solu↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aircraft-Integrated Meteorological Measurement System (AIMMS) Instrument Handbook

The AIMMS-20 probe is manufactured by Aventech Research Inc. and measures platform position, velocity, attitude, ambient temperature, static pressure, and the differential pressures from a 5-port hemispheric gust probe, and combines all these measured data into a calculation of the ambient winds. A detailed description of the AIMMS-20 specifications is available here. Note: The Aventech engineers use the aircraft-centric frame of reference common to aeronautical engineering, which defines z as down.

54 ENVIRONMENTAL SCIENCES↗

Specimen Size Artifacts Associated with a Glovebox Deployable Laser Flash Diffusivity Measurement System

To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

S0 Uncrewed Aircraft System Measurement Characterization Field Campaign Report

The lower atmosphere contributes directly to the modulation of weather and climate. Understanding the importance of this part of the atmosphere, scientists have worked to improve the representation of the atmospheric boundary layer in numerical prediction tools. Such work depends upon information from observing systems, including remote sensors, weather balloons, and research aircraft. Recent years have seen significant advances in uncrewed aircraft systems (UAS) for atmospheric research. Those efforts have provided new perspectives on atmospheric and surface conditions, particularly from smaller UAS (sUAS) platforms. This field campaign included collection of data using several sUAS, and comparing the sUAS data to those from different observing facilities at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in Oklahoma. Over the course of one week, the Black Swift Technologies and University of Nebraska teams conducted flights for the sole purpose of system evaluation and intercomparison. In addition, these teams conducted joint flight operations at the Marshall, Oklahoma Mesonet site alongside teams from the University of Colorado, University of Oklahoma, and Oklahoma State University to collect additional data for side-by-side comparison. Platforms operated by Black Swift Technologies and the University of Nebraska under this project included one fixed-wing and two rotary-wing platforms, as well as an instrumented surface vehicle. These include the Black Swift Technologies S0 UAS, the University of Nebraska M600 UAS, a University of Nebraska-operated Meteomatics Meteodrone UAS, and the University of Nebraska CoMeT (Combined Mesonet and Tracker) vehicle. Additional details on all of these platforms can be found in de Boer et al. (in prep). In total, 95 sUAS flights were conducted for a combined total of 18.6 flight hours. The S0 was operated both to the south and north of the SGP 60 m tower, while the M600 and Meteodrone were operated directly to the east of the tower. Weather conditions were generally good, with moderate winds. Flights were conducted both to follow the extra radiosondes that were launched as part of this campaign, as well as to conduct extended statistical sampling at tower instrument heights. The later flights also provided data for statistical platform intercomparison.

54 ENVIRONMENTAL SCIENCES↗

Ramp Generator for Electron Scanner in SNS Beam Profile Measurements System

A new fast high voltage Ramp Generator to deflect an electron beam in the Electron Scanner is required at the Spallation Neutron Source (SNS) in the Oak Ridge National Laboratory. The Electron Scanner is used for non-destructively measuring the transverse profiles of the proton beam in the accumulator ring of the SNS [1]. The existing deflector is obsolete and needs to be replaced. A new Ramp Generator is proposed based on fast high voltage MOSFET power switches. Two configurations have been considered. One is bipolar, with two opposite polarity power supplies and one switch module or two single switches, and the other is unipolar, with one power supply and two switch modules. Schematics and performance of both options are described, and results of the prototype testing are presented in the paper.

Peplov, Vladimir↗

A beam profile and position measurement system for the IPF target

Currently one determines the size and position of the proton beam at the IPF target using plastic films. These films are installed in a target carrier, lowered into position, exposed to the beam, raised back up to the hot cell, removed from the target carrier, and assessed via a video feed. About an hour is required for each cycle of measurement. Because of this high cost in terms of time the users usually settle for a beam that is good enough to meet their needs, but not as good as they would like. I propose here a diagnostic device that would enable a measurement of under two seconds. This would enable delivery of a better-quality beam in less time.

43 PARTICLE ACCELERATORS↗