Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mechanism of efficient double-strand break repair by a long non-coding RNA

Mechanistic studies in DNA repair have focused on roles of multi-protein DNA complexes, so how long non-coding RNAs (lncRNAs) regulate DNA repair is less well understood. Yet, lncRNA LINP1 is over-expressed in multiple cancers and confers resistance to ionizing radiation and chemotherapeutic drugs. Here, we unveil structural and mechanistic insights into LINP1’s ability to facilitate non-homologous end joining (NHEJ). We characterized LINP1 structure and flexibility and analyzed interactions with the NHEJ factor Ku70/Ku80 (Ku) and Ku complexes that direct NHEJ. LINP1 self-assembles into phase-separated condensates via RNA–RNA interactions that reorganize to form filamentous Ku-containing aggregates. Structured motifs in LINP1 bind Ku, promoting Ku multimerization and stabilization of the initial synaptic event for NHEJ. Significantly, LINP1 acts as an effective proxy for PAXX. Collective results reveal how lncRNA effectively replaces a DNA repair protein for efficient NHEJ with implications for development of resistance to cancer therapy.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of efficiencies, loss mechanisms, and performance degradation factors in chopper controlled dc vehical motors. Section 1: Test program results and recommendations

The conventional series motor model is discussed as well as procedures for obtaining, by test, the parameters necessary for calculating performance and losses. The calculated results for operation from ripple free DC are compared with observed test results, indicating approximately 5% or less error. Experimental data indicating the influence of brush shift and chopper frequency are also presented. Both factors have a significant effect on the speed and torque relationships. The losses and loss mechanisms present in a DC series motor are examined and an attempt is made to evaluate the added losses due to harmonic currents and fluxes. Findings with respect to these losses is summarized.

Hamilton, H. B.↗

Determination of efficiencies, loss mechanisms, and performance degradation factors in chopper controlled dc vehical motors. Section 2: The time dependent finite element modeling of the electromagnetic field in electrical machines: Methods and applications

The time dependent solution of the magnetic field is introduced as a method for accounting for the variation, in time, of the machine parameters in predicting and analyzing the performance of the electrical machines. The method of time dependent finite element was used in combination with an also time dependent construction of a grid for the air gap region. The Maxwell stress tensor was used to calculate the airgap torque from the magnetic vector potential distribution. Incremental inductances were defined and calculated as functions of time, depending on eddy currents and saturation. The currents in all the machine circuits were calculated in the time domain based on these inductances, which were continuously updated. The method was applied to a chopper controlled DC series motor used for electric vehicle drive, and to a salient pole sychronous motor with damper bars. Simulation results were compared to experimentally obtained ones.

Hamilton, H. B.↗

Improving Computational Efficiency of Mechanical Finite Element Method Simulations for PV Modules: Preprint

In this work we have elucidated the trade off between structural mechanics FEM model accuracy and computation time by employing lower fidelity viscoelastic models. Results indicate that computation time can easily be cut in half while only expecting a potential maximum error of 10 % by considering lower fidelity models. A novel approach to produce the Prony Series fit for viscoelastic characterization has also been presented. Employing this approach, we were able to achieve a further 10 % reduction in computation time without further sacrificing simulation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Work of Mechanical Degradation in Elongating Polymer Melts

Molecular dynamics simulations are used to study the mechanical degradation of well-entangled polymer melts during uniaxial extensional flow. Simulations measure the transient rise in extensional stresses and relate them to the molecular alignment and scission of chain backbones. Intermolecular entanglements couple chain scission in space and time, making degradation sensitive to deformation history and strain rate in ways not displayed by dilute polymer solutions. The rate of chain scission is nonmonotonic and peaks at strains corresponding to the maximum extensibility of entanglement segments but prior to the full extension of chain backbones. We measure a specific work per scission event w* and decompose it into separate contributions associated with chain alignment, chemical bond breaking, and scission-induced plasticity. We find chain scission in melts requires activating plastic dissipation that is multiple orders of magnitude larger than the chemical work required to break a covalent backbone bond. Our findings underscore the critical need to consider bulk polymer mechanics and rheology in designing efficient mechanical degradation and mechanochemical processes.

36 MATERIALS SCIENCE↗

Efficient probabilistic fracture mechanics analysis

A systematic and efficient method for probabilistic fracture mechanics analysis is proposed. The method is based on a most-probable-point-locus concept. The locus is obtained iteratively where the initial locus is determined using the linear approximation of the service life N(X) function about the mean values of the random variables X. Linear and quadratic approximations of N(X) are established locally at the most probable points, and the reliability analysis methods are used to compute the cumulative probabilities. By using two examples, the proposed method is demonstrated to be efficient and accurate. One example involved a random loading and N(X) was computed using cycle-by-cycle integration. The method is general and can be applied to other performance functions. It is particularly suitable when the computation of the performance function is time consuming such that Monte Carlo simulation is prohibitively costly.

Wu, Y.-T.↗

Power System for Venus Surface Exploration

A radioisotope power and cooling system is designed to provide electrical power for a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep electronic components at a temperature below ambient. The fundamental cooling parameters are the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density (90 bar CO2) atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus, with a small contribution of heat generation from electronics and sensors. Both thermoelectric (RTG) and dynamic power conversion systems were analyzed, based on use of a standard isotope (General-purpose heat source, or GPHS) brick. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500-watt power class, laboratory-tested Stirling engines. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg. Additional information is included in the original extended abstract.

Landis, Geoffrey A.↗

Venus Surface Power and Cooling System Design

A radioisotope power and cooling system is designed to provide electrical power for the a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors simply cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep certain components at a temperature below ambient. The fundamental cooling requirements are comprised of the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus. Assuming 5 cm radial thickness of ceramic blanket insulation, the ambient heat load was estimated at approximately 77 watts. With an estimated quantity of 10 watts of heat generation from electronics and sensors, and to accommodate some level of uncertainty, the total heat load requirement was rounded up to an even 100 watts. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. The maximum theoretically obtainable efficiency is 47.52 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500 watt power class, laboratory-tested Stirling engines at GRC. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg.

Landis, Geoffrey A.↗

Performance of a 300-horsepower Hispano-Suiza airplane engine

The National Bureau of Standards tested a 300-horsepower Hispano-Suiza engine to determine the characteristic performance of the engine at various altitudes. The engine was operated at the ground, at 25,000 feet, and at intermediate altitudes, both at full loads similar to those that would be imposed upon the engine at various speeds by a propeller whose normal full-load speed was 1,800 r.p.m. Friction horsepower also was determined in order that the mechanical efficiency of the engine might be calculated. From the test data there were computed the brake horsepower, brake mean effective pressure, specific fuel consumption, mixture ratio, jacket loss, exhaust loss, and thermal, mechanical, and volumetric efficiencies. A record of jacket water temperatures, oil temperatures, manifold pressures, etc., shows the conditions under which the test was made.

Sparrow, S W↗

Tuning Thermal and Mechanical Properties of Polydimethylsiloxane with Carbon Fibers

In order to meet the needs of constantly advancing technologies, fabricating materials with improved properties and predictable behavior has become vital. To that end, we have prepared polydimethylsiloxane (PDMS) polymer samples filled with carbon nanofibers (CFs) at 0, 0.5, 1.0, 2.0, and 4.0 CF loadings (w/w) to investigate and optimize the amount of filler needed for fabrication with improved mechanical properties. Samples were prepared using easy, cost-efficient mechanical mixing to combine the PDMS and CF filler and were then characterized by chemical (FTIR), mechanical (hardness and tension), and physical (swelling, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and coefficient of thermal expansion) analyses to determine the material properties. We found that hardness and thermal stability increased predictably, while the ultimate strength and toughness both decreased. Repeated tension caused the CF-filled PDMS samples to lose significant toughness with increasing CF loadings. The hardness and thermal degradation temperature with 4 wt.% CF loading in PDMS increased more than 40% and 25 °C, respectively, compared with the pristine PDMS sample. Additionally, dilatometer measurements showed a 20% decrease in the coefficient of thermal expansion (CTE) with a small amount of CF filler in PDMS. In this study, we were able to show the mechanical and thermal properties of PDMS can be tuned with good confidence using CFs.

degradation temperature↗

Fabric properties and electric efficiency limits of mechanical moisture extraction from fabrics

Residential clothes drying consume about 650 TBtu of primary energy per year in the United States, equivalent to 3% of primary residential energy consumption. There is a strong impetus to reduce the energy consumption of clothes dryers by both improving existing technology and developing alternatives that use fundamentally different drying mechanisms. Clothes drying technologies are broadly classified into either evaporative or mechanical drying. The focus of this paper is on mechanical drying, including vibrational, centrifugal, and press-based methods. In this work, the physical processes involved in these mechanical fabric drying processes were analyzed to develop general theories of mechanical cloth drying energy efficiency. Quantitative evaluation of the theories requires measured fabric properties. To accomplish this, a set of experiments was conducted on samples of a standard test fabric. The fabric was a cotton-polyester blend specified by the US Department of Energy to evaluate the standardized efficiency of all residential clothes dryers in the US. Mercury porosimetry experiments were conducted to determine the fabric pore size distribution, apparent density, and porosity. Elasticity experiments were conducted to determine the fabric’s Young’s modulus. Isostatic press experiments were conducted to establish a relationship between compression force and fabric moisture content. The data resulting from these experiments were combined with mathematical models developed in this work to calculate the theoretical maximum performance limits for mechanical drying of the standard fabric. The results of the analysis are used to make recommendations for the most promising technologies that offer the greatest potential energy savings for residential clothes drying.

36 MATERIALS SCIENCE↗

Efficient dynamic simulation for multiple chain robotic mechanisms

An efficient O(mN) algorithm for dynamic simulation of simple closed-chain robotic mechanisms is presented, where m is the number of chains, and N is the number of degrees of freedom for each chain. It is based on computation of the operational space inertia matrix (6 x 6) for each chain as seen by the body, load, or object. Also, computation of the chain dynamics, when opened at one end, is required, and the most efficient algorithm is used for this purpose. Parallel implementation of the dynamics for each chain results in an O(N) + O(log sub 2 m+1) algorithm.

Lilly, Kathryn W.↗

Testing of YUH-61A helicopter transmission in NASA Lewis 2240-kW (3000-hp facility

A helicopter transmission that was being considered for the Army's Utility Tactical Transport Attack System (UTTAS) was tested in the NASA Lewis 2240-kW (3000-hp) test facility to obtain the transmission's operational data. The results will form a vibration and efficiency data base for evaluation similar-class helicopter transmissions. The transmission's mechanical efficiency was determined to be 98.7 percent at its rated power level of 2080 kW (2792 hp). At power levels up to 113 percent of rated the transmission displayed 56 percent higher vibration acceleration levels on the right input than on the left input. Both vibration signature analysis and final visual inspection indicated that the right input spiral-bevel gear had poor contact patterns. The highest vibration meter level was 52 g's rms at the accessory gear, which had free-wheeling gearsets. At 113 percent power and 100 percent rated speed the vibration meter levels generally ranged from 3 to 25 g's rms.

Mitchell, A. M.↗

Performance of a Liberty 12 airplane engine

In cooperation with the Engineering Division of the Air Service of the United States Army, a Liberty-12 engine has been tested at the Bureau of Standards. The program of tests was planned to yield that information considered most important in determining the value of the engine for aviation. Full power runs were made at the ground, at 25,000 feet, and at several intermediate altitudes. To determine the mechanical efficiency of the engine, friction horsepower was measured at the ground and at 15,000 feet. As a basis for predicting engine performance with a propeller, a series of tests was made in which the dynamometer load and engine throttle were adjusted at each speed to simulate the engine load which would be imposed at that speed by a propeller operating under normal full load at 1,700 r.p.m. Among the quantities calculated from the test measurements are: brake horsepower; break mean effective pressure; fuel consumption; mixture ratio; mechanical, thermal, and volumetric efficiency; and the percentage of the heat in the fuel appearing in the jacket water and in the exhaust. Jacket water temperature, oil temperature, manifold pressure, etc., are recorded to show the conditions under which the test was made.

Sparrow, S W↗

A method of evaluating efficiency during space-suited work in a neutral buoyancy environment

The purpose was to investigate efficiency as related to the work transmission and the metabolic cost of various extravehicular activity (EVA) tasks during simulated microgravity (whole body water immersion) using three space suits. Two new prototype space station suits, AX-5 and MKIII, are pressurized at 57.2 kPa and were tested concurrently with the operationally used 29.6 kPa shuttle suit. Four male astronauts were asked to perform a fatigue trial on four upper extremity exercises during which metabolic rate and work output were measured and efficiency was calculated in each suit. The activities were selected to simulate actual EVA tasks. The test article was an underwater dynamometry system to which the astronauts were secured by foot restraints. All metabolic data was acquired, calculated, and stored using a computerized indirect calorimetry system connected to the suit ventilation/gas supply control console. During the efficiency testing, steady state metabolic rate could be evaluated as well as work transmitted to the dynamometer. Mechanical efficiency could then be calculated for each astronaut in each suit performing each movement.

Greenisen, Michael C.↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗