Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector’s energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sub-additivity in combining infiltration with mechanical ventilation for single zone buildings

We report that in determining ventilation rates, it is often necessary to combine naturally-driven infiltration, with air flows from mechanical systems. When there are balanced mechanical systems, the solution is simple additivity, because a balanced system does not impact the internal pressure of the space or the air flows through the building envelope. Unbalanced systems, however, change internal pressures and therefore can impact natural ventilation non-linearly in such a way as to make it sub-additive. Several sub-additive approaches are found in the literature, but they are not robust across the full spectrum from tight to leaky buildings and ranges of mechanical ventilation air flow rates. There are two approaches for combining natural infiltration with mechanical ventilation that require different solutions. The forward problem is to find the total air flow when adding mechanical ventilation to natural infiltration, and this application has been investigated in previous studies. The inverse problem finds the required mechanical ventilation in order to meet a total ventilation rate given a known amount of natural infiltration. This article presents the results of millions of hours of simulations of the physically correct solution, which span a broad range of climates, air leakage and structural conditions. This large dataset allows for the comparison with three literature models and the development of new robust sub-additivity models. These improved models are for use with unbalanced systems appropriate for consensus standards and guidelines for both the forward and inverse problem. Finally, they reduce errors to 1% or less and work across the air tightness spectrum.

42 ENGINEERING↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stable Small Animal Mechanical Ventilation for Dynamic Lung Imaging to Support Computational Fluid Dynamics Models

Pulmonary computational fluid dynamics models require 3D images to be acquired over multiple points in the dynamic breathing cycle, with no breath holds or changes in ventilatory mechanics. With small animals, these requirements result in long imaging times ({approx}90 minutes), over which lung mechanics, such as compliance, can gradually change if not carefully monitored and controlled. These changes, caused by derecruitment of parenchymal tissue, are manifested as an upward drift in peak inspiratory pressure or by changes in the pressure waveform and/or lung volume over the course of the experiment. We demonstrate highly repeatable mechanical ventilation in anesthetized rats over a long duration for pulmonary CT imaging throughout the dynamic breathing cycle. We describe significant updates to a basic commercial ventilator that was acquired for these experiments. Key to achieving consistent results was the implementation of periodic deep breaths, or sighs, of extended duration to maintain lung recruitment. In addition, continuous monitoring of breath-to-breath pressure and volume waveforms and long-term trends in peak inspiratory pressure and flow provide diagnostics of changes in breathing mechanics.

59 BASIC BIOLOGICAL SCIENCES↗

Simplified Methods for Combining Natural and Mechanical Ventilation

In determining ventilation rates, it is often necessary to combine naturally-driven ventilation, such as infiltration, with mechanical systems. Modern calculation methods are sufficiently powerful that this can be done from first principles with time varying flows, but for some purposes simplified methods of combining the mechanical and natural ventilation are required—we call this “superposition”. An example of superposition would be ventilation standards that may pre-calculate some quantities within the body of the standard. When there are balanced mechanical systems, the solution is simple additivity, because a balanced system does not impact the internal pressure of the space. Unbalanced systems, however, change internal pressures and therefore can impact natural ventilation in such a way as to make it sub-additive. Several sub-additive superposition models are found in the literature. This paper presents the results of millions of hours of simulations of the physically correct solution, which span a broad range of climates, air leakage and structural conditions. This wide range of data allows for the comparison of three superposition models from the literature and eight new ones. The results show that by using the appropriate model(s) superposition errors can be reduced significantly, from the 20% over-prediction of simple linear addition to 1% or less.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Methods for Combining Natural and Mechanical Ventilation

In determining ventilation rates, it is often necessary to combine naturally-driven ventilation, such as infiltration, with mechanical systems. Modern calculation methods are sufficiently powerful that this can be done from first principles with time varying flows, but for some purposes simplified methods of combining the mechanical and natural ventilation are required—we call this “superposition”. An example of superposition would be ventilation standards that may pre-calculate some quantities within the body of the standard. When there are balanced mechanical systems, the solution is simple additivity, because a balanced system does not impact the internal pressure of the space. Unbalanced systems, however, change internal pressures and therefore can impact natural ventilation in such a way as to make it sub-additive. Several sub-additive superposition models are found in the literature. This paper presents the results of millions of hours of simulations of the physically correct solution, which span a broad range of climates, air leakage and structural conditions. This wide range of data allows for the comparison of three superposition models from the literature and eight new ones. The results show that by using the appropriate model(s) superposition errors can be reduced significantly, from the 20% over-prediction of simple linear addition to 1% or less.

42 ENGINEERING↗

Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

Changing the rate of airflow through a home affects the annual thermal conditioning energy. Large-scale changes to airflow rates of the housing stock can significantly alter the energy consumption of the residential energy sector. However, the complexity of existing residential energy models hampers the ability to estimate the impact of policy changes on a state or nationwide level. The Incremental Ventilation Energy (IVE) model developed in this study was designed to combine the output of simple airflow models and a limited set of home characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modelers to use existing databases of home characteristics to determine the impact of policy on ventilation at a population scale. In this report, we describe the IVE model and demonstrate that its estimates of energy change are comparable to the estimates of a wellvalidated, complex residential energy model when applied to homes with limited parameterization. Homes with extensive parameterization would be more accurately characterized by complex residential energy models. The demonstration included a range of home types, climates, and ventilation systems that cover a large fraction of the residential housing sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of a mechanically ventilated double-skin facade with venetian sun-shading device: A full-scale investigation in controlled environment

The aim of this article is to present results of an experimental campaign performed on a full-scale facility provided with a double-skin facade. The behaviour of this architectural concept is tested under controlled climatic conditions. A summer case is scrutinised under different configurations: variation of the airflow through the double-skin facade and different angle of the solar shading device. This paper describes the experimental conditions, as well the test facility and the tested facade element. The results show the temperatures of the test cell and the facade and how they depend on the climatic conditions and the sun-shading device blade angles. One objective of this research was to measure and provide extensive data set detailing air and surface temperatures on the double-skin facade, together with airflow rates and air velocities. The experiments are fully described so that the results can be used for the validation of numerical models dealing with ventilated double-skin facades with venetian sun-shading device. (author)

14 SOLAR ENERGY↗

Development of an Outdoor Temperature Based Control Algorithm for Residential Mechanical Ventilation Control

The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗