Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical capabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗

The Future of LANSCE [Slides]

LANSCE is a NNSA Center for Materials and Nuclear Research. An aging stockpile presents unique challenges in materials and nuclear science. The grand challenge of a predictive materials capability includes design to manufacture and born certified. This requires capability to study manufacture to structure relationships and capability to study structure to performance relationships. LANSCE has the capabilities needed for this mission. We leverage our capability to provide broader benefit to the Nation including production of medical isotopes, industrial irradiation facility for electronics certification, and fundamental materials and physics research. The LANSCE linear accelerator is nearly 50 years old. The severity of maintenance issues is increasing. We must reinvest in LANSCE to ensure mission delivery into the future. We must develop new capability to be responsive to changing mission needs. Ultimately this will require a Dynamic Mesoscale Materials Science Capability. Now we must develop a pathway to MaRIE that ensures continued operation of LANSCE.

43 PARTICLE ACCELERATORS↗

Monolithic mtesla-level magnetic induction by self-rolled-up membrane technology

Monolithic strong magnetic induction at the mtesla to tesla level provides essential functionalities to physical, chemical, and medical systems. Current design options are constrained by existing capabilities in three-dimensional (3D) structure construction, current handling, and magnetic material integration. We report here geometric transformation of large-area and relatively thick (~100 to 250 nm) 2D nanomembranes into multiturn 3D air-core microtubes by a vapor-phase self-rolled-up membrane (S-RuM) nanotechnology, combined with postrolling integration of ferrofluid magnetic materials by capillary force. Hundreds of S-RuM power inductors on sapphire are designed and tested, with maximum operating frequency exceeding 500 MHz. An inductance of 1.24 μH at 10 kHz has been achieved for a single microtube inductor, with corresponding areal and volumetric inductance densities of 3 μH/mm 2 and 23 μH/mm 3 , respectively. The simulated intensity of the magnetic induction reaches tens of mtesla in fabricated devices at 10 MHz.

42 ENGINEERING↗

Sandia's Research in Support of COVID-19 Pandemic Response: Materials Science

Sandia Materials Science Investment Area contributed to the SARS-CoV-2 virus and COVID-19 disease which represent the most significant pandemic threat in over 100 years. We completed a series of 7, short duration projects to provide innovative materials science research and development in analytical techniques to aid the neutralization of COVID-19 on multiple surfaces, approaches to rapidly decontaminate personal protective equipment, and pareto assessment of construction materials for manufacturing personal protective equipment. The developed capabilities and processes through this research can help US medical personnel, government installations and assets, first responders, state and local governments, and multiple federal agencies address the COVID-19 Pandemic.

36 MATERIALS SCIENCE↗

Ultra-compact Imaging Technology (CRADA Final Report)

As part of the Cyclotron Road program, Synopic (formerly FlatCam LLC) sought to investigate the benefits of its depth-sensitive imaging techniques. The basic principle involved using a thin mask specially designed to encode light reaching a sensor, in conjunction with optimized computational algorithms, in such a manner that allowed for both miniaturization of imaging systems and improved computation toward high resolution, three-dimensional imaging. By thoroughly exploring the resolution, mask/optical design, and algorithmic capabilities of our depth sensitive technology, we expand the potential applications for (but not limited to) medical, consumer and industrial purposes. The project aimed to develop new imaging systems by building on previous work and using 1) materials capable of modulating and 2) sensors capable of measuring visible and longer wavelengths. Preliminary research was conducted to design, fabricate and characterize imaging systems with the goal of improving resolution, enhancing single capture, three-dimensional imaging, and extending depth of field of captured images. The primary goal was to determine whether adapting the depth-sensitive imaging system is feasible, and early results are promising.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multimorphic Materials: Spatially Tailoring Mechanical Properties via Selective Initiation of Interpenetrating Polymer Networks

Access to multimaterial polymers with spatially localized properties and robust interfaces is anticipated to enable new capabilities in soft robotics, such as smooth actuation for advanced medical and manufacturing technologies. Here, orthogonal initiation is used to create interpenetrating polymer networks (IPNs) with spatial control over morphology and mechanical properties. Base catalyzes the formation of a stiff and strong polyurethane, while blue LEDs initiate the formation of a soft and elastic polyacrylate. IPN morphology is controlled by when the LED is turned “on”, with large phase separation occurring for short time delays (≈1–2 min) and a mixed morphology for longer time delays (>5 min), which is supported by dynamic mechanical analysis, small angle X-ray scattering, and atomic force microscopy. Through tailoring morphology, tensile moduli and fracture toughness can be tuned across ≈1–2 orders of magnitude. Furthermore, a simple spring model is used to explain the observed mechanical behavior. Photopatterning produces “multimorphic” materials, where morphology is spatially localized with fine precision (<100 µm), while maintaining a uniform chemical composition throughout to mitigate interfacial failure. As a final demonstration, the fabrication of hinges represents a possible use case for multimorphic materials in soft robotics.

36 MATERIALS SCIENCE↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

Supervisory Algorithm for Autonomous Hemodynamic Management Systems

Future military conflicts will require new solutions to manage combat casualties. The use of automated medical systems can potentially address this need by streamlining and augmenting the delivery of medical care in both emergency and combat trauma environments. However, in many situations, these systems may need to operate in conjunction with other autonomous and semi-autonomous devices. Management of complex patients may require multiple automated systems operating simultaneously and potentially competing with each other. Supervisory controllers capable of harmonizing multiple closed-loop systems are thus essential before multiple automated medical systems can be deployed in managing complex medical situations. The objective for this study was to develop a Supervisory Algorithm for Casualty Management (SACM) that manages decisions and interplay between two automated systems designed for management of hemorrhage control and resuscitation: an automatic extremity tourniquet system and an adaptive resuscitation controller. SACM monitors the required physiological inputs for both systems and synchronizes each respective system as needed. We present a series of trauma experiments carried out in a physiologically relevant benchtop circulatory system in which SACM must recognize extremity or internal hemorrhage, activate the corresponding algorithm to apply a tourniquet, and then resuscitate back to the target pressure setpoint. SACM continues monitoring after the initial stabilization so that additional medical changes can be quickly identified and addressed, essential to extending automation algorithms past initial trauma resuscitation into extended monitoring. Overall, SACM is an important step in transitioning automated medical systems into emergency and combat trauma situations. Future work will address further interplay between these systems and integrate additional medical systems.

42 ENGINEERING↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

Critical steps in preventing future pandemics. Early lessons from the Covid-19 crisis for addressing natural and deliberate biological threats.

This report summarizes a virtual workshop on early lessons from the COVID-19 pandemic as they pertain to proactively addressing future biological threats. Co-hosted by Sandia National Laboratory (Sandia) and the Council on Strategic Risks (CSR) in August 2020, the discussion involved experts who at that time were leading innovative efforts in various U.S. government agencies, industry, and academia sharing observations from their ongoing pandemic response efforts. Based on the input by these expert participants, it is clear that even though the pandemic response is ongoing, the following recommendations will be important to consider for more successfully addressing biological threats in the future: Continue building on the cross-sector collaboration and agility shown in the COVID-19 response; Expand capabilities for detecting biological threats early; Prioritize ways to create and disseminate medical countermeasures even faster; Create the U.S. bio industrial base needed for rapid response to biological threats, and keep it healthy; and, Major government reorganization may not be needed if there is effective work to form coalitions, improve coordination, and expand steady-state and surge capacities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of Additive Manufacturing Capabilities for Processing Refractory Alloys Under the Mo-99 Program

The enriched 100 Mo target, denoted as aMo, that Northstar Medical Radioisotopes is developing to produce 99 Mo from an accelerator-based method is a disk-type geometry with a 0.5–0.715 mm thickness and a 29 mm outer diameter. A press and sinter method was adopted to fabricate these samples from aMo powder feedstock. Inherent porosity from the press and sinter method makes the disks more easily dissolvable during 99 Mo postprocessing. However, the disk-type geometry will be subject to thermal stresses due to temperature variations once the geometry is in line with the accelerated electron beam, causing warping and possible failure. Additive manufacturing (AM) processes such as laser powder bed fusion (LPBF) enable the manufacturing of custom, complex geometries that may otherwise be difficult to produce with more conventional methods (e.g., press and sinter approach). Therefore, the National Nuclear Security Administration’s Molybdenum-99 Program invested in developing an AM facility dedicated to processing and printing refractory powders. This report details the LPBF process, how irregular refractory powder can be prepared for LPBF, and the equipment that is available to support the program.

36 MATERIALS SCIENCE↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Looking back at 50 years of cutting-edge capabilities: LANSCE ‘underpins Los Alamos as a world-class scientific institution’

What started with an idea and a memo has since grown into a one-of-a-kind, world-renowned facility that contributes to the nation’s advancement of science and technology. First known as LAMPF (Los Alamos Meson Physics Facility) until the 1990s when it became LANSCE (Los Alamos Neutron Science Center), the facility is celebrating the 50th anniversary of its first full-capacity proton beam on June 9, 1972. Since then, LANSCE has contributed to a range of national security goals, such as supporting the Lab’s stockpile stewardship program, helping to advance the science of medical radioisotopes, improving the understanding of hydrodynamics, and more. “LANSCE has served the nation through its near-unique capabilities,” said Alan Carr, Senior Historian at the National Security Research Center, which houses the facility’s evolution through decades of documents, photos and other materials. “Since 1972, LANSCE has been the Lab’s major experimental science facility and underpins Los Alamos as a world-class scientific institution. This was true 50 years ago and is still true today.” In commemoration of this anniversary, we’re taking a look back at LANSCE’s historic five decades, including its first director, earliest milestones and important contributions to national security.

43 PARTICLE ACCELERATORS↗

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flow Measurements in Pressurized Helium Gas Cooling Channels: Rev. 1

Compressed helium gas is used to cool the NorthStar Medical Radioisotope (NMR) target system, also called the trident, chosen due to its superior heat transfer capabilities and its inability to react with Molybdenum-100 (Mo-100) during irradiation. To test the housing and NMR target stack at Los Alamos National Laboratory (LANL), two sets of helium gas flow loop facilities have been set-up and tested. One system is used for bench-top experiments to systematically investigate individual components of the NMR target, and the other, larger system is more representative of the system at NMR and is used for testing the full NMR target stack.

43 PARTICLE ACCELERATORS↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗