Search NASA⌕ Search

SEARCH · Search NASA

Results for “medium frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectral Analytics of Solar Photovoltaic Power Output for Optimal Distributed Energy Resource Utilization

This paper examines the spectral analytics of solar photovoltaic (PV) power in order to understand its frequency content. This information is then used to illustrate that the different frequency components of PV generation can be consumed locally by controlling local distributed energy resources in residential/commercial buildings. The solar PV generation signal is divided into three components: high frequency (second-level), medium frequency (minute-level), and low-frequency that correlate with the solar activity. One year of solar PV power data is analyzed with 1-second resolution to find the ideal bounds for the different frequency bands. Results show that by employing intelligent control of Heating, Ventilation and Air-Conditioning (HVAC) systems, HVAC loads are able to accommodate the low and medium frequency components of the PV generation while local energy storage systems can be used to offset the high frequency components. This demonstrates the ability to spatially-local consumption of PV generation using controllable loads so as to minimize impact on the grid, reduce size of storage devices, and increase solar PV penetration levels.

Olama, Mohammed M.↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space-time spectral structure of a GLAS general circulation model and a comparison with observations

The wavenumber-frequency spectra of geopotential height computed from a winter simulation of a general circulation model are compared with the observed winter spectra averaged over 15 winters. The space and time scales studied include: (1) stationary planetary waves; (2) stationary synoptic-scale waves; (3) low-frequency planetary waves; (4) low frequency synoptic-scale waves; (5) medium-frequency planetary waves; and (6) medium frequency synoptic-scale waves. Variances in these categories are presented and their distributions with latitude and height are discussed.

Straus, D. M.↗

Angular momentum of elliptically polarised cnoidal waves and breathers in a nonlinear gyrotropic medium with frequency dispersion

We have analysed expressions for the spin part of the density vector of the angular momentum (moment of momentum) of elliptically polarised cnoidal waves and breathers propagating in an isotropic gyrotropic medium with second order frequency dispersion and spatial cubic nonlinearity dispersion. We have found that, due to nonlinear gyration, the density of the angular momentum depends on time and propagation coordinates. The bibliography includes 25 references. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Medium Voltage Three-Stage Power Converter Topology for Distribution Grid Scale Energy Storage Systems

This work proposes a three-stage converter topology with a medium frequency isolation transformer for direct integration of energy storage systems into medium voltage distribution grids. The distributed architecture of the topology, using standard AC/DC converters, has been developed with the aim of plug-and-play capability and voltage and power scalability. The medium frequency transformer facilitates improved power density, while its 20:1 voltage translation capability enables the use of limited voltage level (500 Vdc) of the commercially available batteries. This paper presents the topology structure and details how it can be scaled to reach the full range of the distribution grid voltages and the required power levels. A transformer design for 500 Hz rated frequency is discussed. The control scheme of the converter equipped with voltage support, frequency support, and black start capabilities is also presented. Control hardware-in-the-loop results using OPAL-RT, with converter switching models connected to a weak IEEE-4 node test feeder modified for the aforementioned grid services, are provided to show the topology feasibility.

Chinthavali, Madhu Sudhan↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current Source Converters

Magnetic components play a key role in determining the size, cost, efficiency of a power converter. They are more significant in current source converters, where the dc-link energy is stored in an inductor/transformer. In such cases, the magnetics have a predominantly DC flux, superimposed by an AC flux at switching frequency. Previously, permanent magnets have been proposed to offset the DC flux and thereby reduce the size, cost, and losses of the inductors/transformers. This paper starts by analyzing the issue of eddy currents when using such standard permanent magnets, especially in medium frequency applications, making them practically unusable. Alternatively, the paper proposes the use of laminated permanent magnets to reduce these eddy currents and thereby realize the benefits of offsetting the DC flux to reduce the size, cost, and loss of inductors/transformers. Using a soft-switching solid-state transformer as an example, experimental results are presented to show the impact of eddy currents in standard permanent magnets when used with a medium frequency transformer. Here, experimental results showing the benefits of using laminated magnets in reducing the eddy currents are presented.

30 DIRECT ENERGY CONVERSION↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current-Source Converters

Magnetic components have become one of the primary barriers to high power density converters, especially to current-source converters (CSCs). In CSCs, the inductors/transformers have a predominantly dc flux to store energy, which can be offset by standard permanent magnets (PMs). However, eddy currents in standard PMs induce significant losses and thermal stress for medium-frequency applications. This article proposes using laminated PMs to offset the dc flux while reducing eddy currents, leading to significant reductions in the size, cost, and losses of inductors/transformers. Furthermore, the laminated PMs’ optimal location, orientation, and distribution are investigated to generalize this approach for maximum benefits. Here, three-dimensional finite-element analysis simulation and hardware experiments are presented to validate the effectiveness of the proposed approach in a medium-frequency transformer (MFT) for CSCs. Compared with standard PMs, the proposed use of laminated PMs reduces aggregate core-plus-PM losses by 85% in experiments, and thus, relaxes the MFT thermal design. Finally, the proposed approach is experimentally validated in a 40 kVA flyback-type MFT for a soft-switching solid-state transformer. Compared to the traditional design without any PMs, the proposed design increases the saturation current by 46% while inducing only 5% more losses, leading to significant savings in magnetics cost and size.

30 DIRECT ENERGY CONVERSION↗

Combined operation of two ground transmitters for enhanced ionospheric heating

The combined operation of a high or medium frequency ground transmitter and a VLF transmitter for enhanced ionospheric heating is examined. The high or medium frequency transmitter operating in a pulsed mode produce short-scale density striations that can render the nonlinear mode conversion of the subsequently launched VLF waves into lower hybrid waves. Also if the VLF waves are intense enough, they can excite meter-scale density striations and lower hybrid waves via parametric instabilities. The expected ionospheric effects of the system are discussed.

Lee, M. C.↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Diffraction of radio-frequency waves by plasma turbulence in the edge of a tokamak

The Mie-Lorenz-Debye theory of scattering of radio frequency waves (RF) by filamentary structures in the edge of a tokamak plasma has been established in prior publications. These results have been verified. Theory and computations show that RF can be reflected, refracted, and diffracted by turbulence. Furthermore, the filamentary structures lead to side scattering of waves and excitation of wave modes different from the launched RF. It is important to quantify the overall effect of turbulence on the propagation of RF since efficiency of heating and current drive by RF waves depends upon the wave characteristics. The commonly used RF ranges vary from the low frequency ion-cyclotron (IC) waves, to medium frequency lower-hybrid (LH) waves, to high-frequency electron cyclotron (EC) waves with wavelengths respectively, large, comparable, or smaller than the radial dimensions of the filaments. Currently, we discuss the scattering as well as the forces exerted by different RF in the edge plasma. Also, we present a code for 3D full wave scattering analysis of arbitrary tensor permittivity and plasma density profiles. The study is applicable to ITER-like plasmas, as well as to plasmas in medium sized tokamaks such as TCV, ASDEX-U and DIII-D and high field concepts like SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Perturbations of subionospheric LF and MF signals due to whistler-induced electron precipitation bursts

Increasing attention is now being devoted to the problem of the pitch angle scattering and resulting precipitation of magnetospheric energetic electrons by coherent waves. The present investigation has the objective to report the first evidence of a correlation between whistlers and amplitude perturbations on low-frequency (LF) signals at 37.2 kHz and medium-frequency (MF) signals at 780 kHz. Whistler-correlated amplitude perturbations were observed on a 780-kHz MF signal propagating on an approximately 1800 km path from South America to Palmer. The observed MF perturbations were of order 50 percent in amplitude and developed much more quickly than other changes of comparable magnitude on the signal.

Carpenter, D. L.↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗