Search NASA⌕ Search

SEARCH · Search NASA

Results for “metabolic rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Metabolic rate meter and method

A method is described for measuring the dynamic metabolic rate of a human or animal. The ratio of the exhaled carbon dioxide to a known amount of C(13)02 introduced into the exhalation is determined by mass spectrometry. This provides an instantaneous measurement of the carbon dioxide generated.

Taylor, T. I.↗

Metabolic rate control during extravehicular activity simulations and measurement techniques during actual EVAS

A description of the methods used to control and measure metabolic rate during ground simulations is given. Work levels attained at the Space Environment Simulation Laboratory are presented. The techniques and data acquired during ground simulations are described and compared with inflight procedures. Data from both the Skylab and Apollo Program were utilized and emphasis is given to the methodology, both in simulation and during flight. The basic techniques of work rate assessment are described. They include oxygen consumption, which was useful for averages over long time periods, heart rate correlations based on laboratory calibrations, and liquid cooling garment temperature changes. The relative accuracy of these methods as well as the methods of real-time monitoring at the Mission Control Center are discussed. The advantages and disadvantages of each of the metabolic measurement techniques are discussed. Particular emphasis is given to the problem of utilizing oxygen decrement for short time periods and heart rate at low work levels. A summary is given of the effectiveness of work rate control and measurements; and current plans for future EVA monitoring are discussed.

David J. Horrigan↗

Scaling of metabolic rate on body mass in small mammals at 2.0 g

It is postulated that augmentation of gravitational loading should produce a shift in the classic Kleiber mammalian allometric relationship between metabolic rate and total body mass by an increase in both these parameters. Oxygen consumption rate and body mass measurements of 10 male rabbits 8 months of age were obtained initially for 1.0 g, and then over a 9-week period of chronic centrifugation at 2.0 g. Analysis of covariance showed that the positioning constant at 2.0 g is increased by 17 percent from that at 1.0 g at the P less than 0.001 level, and the exponent is increased by 8 percent at the P = 0.008 level. It is concluded that abatement of gravitational loading in spaceflight will result in a lowering of both allometric parameters.

Pace, N.↗

Role of metabolic rate and DNA-repair in Drosophila aging Implications for the mitochondrial mutation theory of aging

The notion that injury to mitochondrial DNA is a cause of intrinsic aging was tested by correlating the different respiration rates of several wild strains of Drosophila melanogaster with the life-spans. Respiration rate and aging in a mutant of D. melanogaster deficient in postreplication repair were also investigated. In agreement with the rate of living theory, there was an inverse relation between oxygen consumption and median life-span in flies having normal DNA repair. The mutant showed an abnormally low life-span as compared to the controls and also exhibited significant deficiency in mating fitness and a depressed metabolic rate. Therefore, the short life-span of the mutant may be due to the congenital condition rather than to accelerated aging.

Miquel, J.↗

Constraint-Free Measurement of Metabolic Rate

By using hardware and software originally developed for manned spacecraft, metabolism is now measured while subject wears a loose-fitting mask. This more comfortable, less-restrictive measurement technique uses speed, accuracy and control capabilities of a microcomputer. Because mask imposes minimum interference to subject undergoing testing, it can be used to measure respiratory responses to such activities as treadmill exercise. Mask can be worn for long periods with little discomfort.

Koester, K. L.↗

Metabolic Rate and Ground Reaction Force During Motorized and Non-Motorized Treadmill Exercise

PURPOSE: To measure vertical ground reaction force (vGRF) and oxygen consumption (VO2) at several velocities during exercise using a ground-based version of the ISS treadmill in the M and NM modes. METHODS: Subjects (n = 20) walked or ran at 0.89, 1.34, 1.79, 2.24, 2.68, and 3.12 m/s while VO2 and vGRF data were collected. VO2 was measured using open-circuit spirometry (TrueOne 2400, Parvo-Medics). Data were averaged over the last 2 min of each 5-min stage. vGRF was measured in separate 15-s bouts at 125 Hz using custom-fitted pressure-sensing insoles (F-Scan Sport Sensors, Tekscan, Inc). A repeated-measures ANOVA was used to test for differences in VO2 and vGRF between M and NM and across speeds. Significance was set at P < 0.05. RESULTS: Most subjects were unable to exercise for 5 min at treadmill speeds above 1.79 m/s in the NM mode; however, vGRF data were obtained for all subjects at each speed in both modes. VO2 was approx.40% higher during NM than M exercise across treadmill speeds. vGRF increased with treadmill speed but was not different between modes. CONCLUSION: Higher VO2 with no change in vGRF suggests that the additional metabolic cost associated with NM treadmill exercise is accounted for in the horizontal forces required to move the treadmill belt. Although this may limit the exercise duration at faster speeds, high-intensity NM exercise activates the hamstrings and plantarflexors, which are not specifically targeted or well protected by other in-flight countermeasures.

Everett, Meghan E.↗

Rescue Shuttle Flight Re-Entry: Controlling Astronaut Thermal Exposure

A rescue mission for the STS-125 Hubble Telescope Repair Mission requires reentry from space with 11 crew members aboard, exceeding past cabin thermal load experience and risking crew thermal stress potentially causing cognitive performance and physiological decrements. The space shuttle crew cabin air revitalization system (ARS) was designed to support a nominal crew complement of 4 to 7 crew and 10 persons in emergencies, all in a shirt-sleeve environment. Subsequent to the addition of full pressure suits with individual cooling units, the ARS cannot maintain a stable temperature in the crew cabin during reentry thermal loads. Bulk cabin thermal models, used for rescue mission planning and analysis of crew cabin air, were unable to accurately represent crew workstation values of air flow, carbon dioxide, and heat content for the middeck. Crew temperature models suggested significantly elevated core temperatures. Planning for an STS-400 potential rescue of seven stranded crew utilized computational fluid dynamics (CFD) models to demonstrate inhomogeneous cabin thermal properties and improve analysis compared to bulk models. In the absence of monitoring of crew temperature, heart rate, metabolic rate and incomplete engineering data on the performance of the integrated cooling garment/cooling unit (ICG/CU) at cabin temperatures above 75 degrees F, related systems & models were reevaluated and tests conducted with humans in the loop. Changes to the cabin ventilation, ICU placement, crew reentry suit-donning procedures, Orbiter Program wave-off policy and post-landing power down and crew extraction were adopted. A second CFD and core temperature model incorporated the proposed changes and confirmed satisfactory cabin temperature, improved air distribution, and estimated core temperatures within safe limits. CONCLUSIONS: These changes in equipment, in-flight and post-landing procedures, and policy were implemented for the STS-400 rescue shuttle & will be implemented in any future rescue flights from the International Space Station of stranded shuttle crews.

Gillis, David B.↗

Evaluation of Aerobic Standards for Lunar Surface Extravehicular Activities

Introduction: As NASA prepares to return to the Moon, astronauts will need to be physically primed to successfully execute Extravehicular Activities (EVA) on the Lunar surface. Compared to past Apollo missions, Artemis missions will include EVAs of increased physical demand, frequency, intensity, and duration, thus requiring adequate fitness to successfully and safely complete mission objectives. The physical demand associated with partial gravity (g) EVAs on the Moon is expected to be greater compared to microgravity EVAs based on initial workload estimation. Currently, aerobic fitness standards for partial g EVAs are not well supported by high-fidelity data and require further research for establishing standards to protect crew health and performance during Lunar surface missions. Therefore, the aim of this investigation is to characterize metabolic data from Lunar analog simulations and in-flight crew population aerobic capacity data to validate the current NASA 3001 standard for celestial partial g aerobic fitness (aerobic capacity (VO_2pk) ≥36.5ml/kg/min). Methods: In order to evaluate aerobic fitness requirements for Lunar EVAs, the following were performed: 1) preliminary analysis of long-duration (6 hr) EVA analog simulations in the Neutral Buoyancy Laboratory (NBL) and the Active Response Gravity Offload System (ARGOS) to evaluate expected metabolic rates for 1/6 g EVAs (NBL: n=1 female; ARGOS: n=1 male) and 2) assessment of the current NASA 3001 celestial surface EVA aerobic standard (aerobic capacity (VO_2pk) ≥36.5ml/kg/min) with data from an ISS astronaut population (n=30 male + 13 female) captured before and during space flight (flight day 15). Preliminary Results: Average fractional aerobic capacity during simulated EVAs were 33%±7% VO_2pk and 23.3±7% VO_2pk in the NBL and ARGOS, respectively. This was within a previously predicted 30–40% sustainable work rate. Average metabolic rates for some tasks performed in the NBL, such as traverse (40.4% VO_2pk) and ingress (47.1% VO_2pk) were higher than the predicted sustainable work range. In ARGOS, the tasks with the greatest metabolic rates were object relocation (34.2% VO_2pk) and incapacitated crew rescue (27.0% VO_2pk). Characterization of ISS crewmember aerobic capacity determined that the average preflight VO_2pk was 42.1±5.4 ml/kg/min for females and 37.5±5.4 ml/kg/min for males. At preflight, 21.5% of crewmembers were below the 36.5 ml/kg/min in-mission aerobic standard for celestial surface EVA as outlined in NASA-STD-3001. In-flight, both female and male crewmembers experienced reductions in VO_2pk (11.7% and 10.9%, respectively), such that, during the mission, 62% of crewmembers were below the standard aerobic capacity level for celestial surface EVAs. Conclusions: Our preliminary data suggest that while average metabolic rates for simulated Lunar EVA fall within the 30–40% sustainable work range, task specific metabolic rates exceed this range and may indicate that greater fitness is necessary for more strenuous tasks expected to be performed on the Lunar surface. Additionally, deconditioning due to space flight results in most crewmembers falling below the current celestial partial g EVA standard, which may increase risk to crew health and performance and completing mission objectives for surface missions. Further research is necessary in Artemis-specific analog environments to validate the current NASA-3001 aerobic standard for celestial EVAs. Additionally, work is ongoing to validate the current NASA-3001 strength standard for celestial EVAs.

N.C. Strock↗

Microbial Optical Data Processing: A Key Step in the Metabolic Assessment of Lunar Explorer Instrument for Space Biology Applications (LEIA) and Biosentinel’s Payload Data

The BioSensor payload platform on BioSentinel and LEIA autonomously collects optical data from microbial model organisms in liquid culture. The BioSensor is designed to monitor metabolic activity using absorbance measurements of cell density and alamarBlue, a readily available colorimetric redox indicator dye. BioSentinel, a pioneering NASA CubeSat, uses yeast to study deep space radiation. LEIA investigates radiation and lunar gravity response. The experimental setup includes 16 wells equipped with three LEDs (570, 630, and 850 nm) and their corresponding photodetectors. One well is a calibration control without biology while the rest have desiccated cultures. Autonomous rehydration initiates the experiment. Data from the BioSensor are received from the flight and ground units, enabling comparison to uncover location-based metabolic rate variations. This study presents a Python Jupyter notebook developed for efficient data processing of multiple CSV files containing date and time columns, temperature, and well illumination data. It offers a user-friendly interface while maintaining computational power, automatically recognizing and iteratively processing data files in a user-input path. A Hampel filter with a short window eliminates outlier artifacts from sensor dropout. Because absorbance is a relative measurement, conversion from raw illumination requires defining a “blank” value, so the first data points are averaged to provide the necessary denominator. A cube-root function correction mitigates undesired drift caused by air pockets during the fluidic card filling phase, maintaining optical path length consistency. Beer-Lambert's law is applied to further convert absorbance values to cell and dye form concentrations, the desired science parameters. The processed data are saved and visualized as SVG plots. Future plans include extracting specific science parameters from the processed data like growth rate and metabolic rate, and identification of features corresponding to metabolic and phenotypic shifts such as starvation, shifts from aerobic to anaerobic growth, and osmotic stresses.

Space biology↗

Experimentally Determined Overall Heat Transfer Coefficients for Spacesuit Liquid Cooled Garments

A Human-In-The-Loop (HITL) Portable Life Support System 2.0 (PLSS 2.0) test has been conducted at NASA Johnson Space Center in the PLSS Development Laboratory from October 27, 2014 to December 19, 2014. These closed-loop tests of the PLSS 2.0 system integrated with human subjects in the Mark III Suit at 3.7 psi to 4.3 psi above ambient pressure performing treadmill exercise at various metabolic rates from standing rest to 3000 BTU/hr (880 W). The bulk of the PLSS 2.0 was at ambient pressure but effluent water vapor from the Spacesuit Water Membrane Evaporator (SWME) and the Auxiliary Membrane Evaporator (Mini-ME), and effluent carbon dioxide from the Rapid Cycle Amine (RCA) were ported to vacuum to test performance of these components in flight-like conditions. One of the objectives of this test was to determine the overall heat transfer coefficient (UA) of the Liquid Cooling Garment (LCG). The UA, an important factor for modeling the heat rejection of an LCG, was determined in a variety of conditions by varying inlet water temperature, flow rate, and metabolic rate. Three LCG configurations were tested: the Extravehicular Mobility Unit (EMU) LCG, the Oceaneering Space Systems (OSS) LCG, and the OSS auxiliary LCG. Other factors influencing accurate UA determination, such as overall heat balance, LCG fit, and the skin temperature measurement, will also be discussed.

Bue, Grant↗

Core Body Temperature Predictions Using Metabolic Energy Expenditure and Heart Rate During Simulated Extravehicular Activity

Long duration spaceflight missions will require crew to become more autonomous in conducting extravehicular activities (EVA) without direct communication with Mission Control for biomedical support. To enable such autonomy, we are developing a Crew State and Risk Model (CSRM) as a collection of key physiology domains that drive EVA crew capabilities and workloads. One model component of CSRM is human thermal regulation. In this paper, customized development of a baseline model to predict core body temperature is presented using physiology inputs of heart rate and metabolic rate. The model development dataset included a baseline study where participants (n=6, equal male and female) performed a 5-hour EVA in a two-part session while wearing a hybrid space suit simulator (HS3). The first session included an end-to-end EVA traversing 1500 meters to a geology site and traversing back to a habitat conducting geology, payload relocation, and maintenance operations every 500 meters. The second session included standalone tasks of a 2000-meter traverse followed by geology tasks. Thermal measures of core body temperature, local skin temperature, liquid cooling garment temperature, heart rate, and metabolic rate were collected through the test duration. Multiple regression was used to build a linear equation to predict core body temperature from inputs of heart rate and metabolic rate. Heat storage was calculated via predicted core body temperature plus LCG and skin temperatures. The model was tested against a dataset from a pressurized suited test (n=6, equal male and female) in the NASA Active Response Gravity Offload System (ARGOS) conducting similar end-to-end EVA and standalone tasks. Predicted error of the model against the raw test cases was 0.2±0.15 °C. The baseline prediction of core body temperature using heart rates and metabolic rates allows for simple real-time tracking from data collected in-flight to monitor crew consumables and thermal flight limits during EVA.

Bradley Hoffmann↗

Reassessing Hybrid Vigor or Hybrid Dysfunction Using Physiological Trade-Offs in an Endangered Salamander System

Fitness of interspecific hybrids can be higher or lower than that of their parental genotypes, with major ramifications for evolution and conservation. A recent study found that hybrid tiger salamanders had higher metabolic rates than their parental forms. Specifically, the ratio of resting metabolic rate to water loss, which was used as a measure of performance, was greater in hybrids. Recent genetic research showed that over half of the experimental subjects in that study were genetically pure California tiger salamanders (Ambystoma californiense) misclassified as hybrids. We reanalyzed the data using the corrected identification of hybrids and parentals. As expected, updating the classification revealed even stronger evidence for differences between hybrids and parentals. Hybrids had higher resting metabolic rates and greater water loss than parentals. The ratio of resting metabolic rate to water loss was also higher in hybrids. However, we suggest that this ratio might not be a positive measure of salamander performance. Higher metabolic rate means higher energy expenditure, and higher water loss suggests increased risk of desiccation. Both are major challenges for terrestrial amphibians, especially salamanders, which are hypothesized to be low-energy, low-water-loss specialists. Under this hypothesis, the ratio of energy expenditure to water loss is a ratio of two costs rather than a ratio of benefit to cost. While our analyses corroborate and strengthen the previous statistical results, we suggest that high resting metabolic rate is better interpreted as hybrid dysfunction, not vigor. Here, both hypotheses are speculative, and specific research on the fitness effects of these physiological differences is needed to resolve this important ecological question.

Ambystoma californiense↗

An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles

This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO 2 accumulation patterns are of great interest because CO 2 can have negative cognitive effects at higher concentrations and also since CO 2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO 2 levels inside the vehicle’s cabin. The CO 2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h –1 ]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) – 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.

passive sensing↗